Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Radiology ; 253(2): 470-7, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19789235

RESUMO

PURPOSE: To evaluate the flexibility and efficacy of the Willis covered stent in the treatment of distal internal carotid artery (DICA) aneurysms. MATERIALS AND METHODS: The study was approved by the authors' institutional review board, and the research was conducted by the authors' institution and the MicroPort Medical Company (Shanghai, China). Thirty-one patients with 33 DICA aneurysms were considered for treatment with a Willis covered stent. The angiographic assessments were categorized as complete or incomplete occlusion. The data on technical success, initial and final angiographic results, mortality, morbidity, and final clinical outcome were collected, and follow-up was performed at 1, 3, 6, and 12 months and yearly after the procedures. RESULTS: Navigation and deployment of the covered stents were successful in 97.6% (41 of 42; 95% confidence interval [CI]: 93%, 102%) of the attempted stent placement procedures. The initial angiographic results showed a complete occlusion in 23 patients with 25 aneurysms (of 32 aneurysms, 78.1% [95% CI: 63%, 93%]) and an incomplete occlusion in seven patients with seven aneurysms (21.9%). The angiographic follow-up (mean, 14 months [95% CI: 12, 15 months]) findings exhibited a complete occlusion in 27 patients with 29 aneurysms (of 31 aneurysms, 93.5% [95% CI: 84%, 103%]) and an incomplete occlusion in two aneurysms (6.5%), with a mild in-stent stenosis in two patients. The clinical follow-up (mean, 27 months [95% CI: 23, 30 months]) demonstrated that 15 patients experienced a full recovery and 14 patients improved. CONCLUSION: The preliminary results demonstrate good flexibility and efficacy of the Willis covered stent in the treatment of DICA aneurysms in selected patients; longer follow-up and expanded clinical trials are needed.


Assuntos
Doenças das Artérias Carótidas/terapia , Artéria Carótida Interna , Aneurisma Intracraniano/terapia , Stents , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo , Criança , Materiais Revestidos Biocompatíveis , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Politetrafluoretileno , Radiografia Intervencionista , Adulto Jovem
2.
Zhongguo Yi Liao Qi Xie Za Zhi ; 32(5): 373-6, 2008 Sep.
Artigo em Zh | MEDLINE | ID: mdl-19119661

RESUMO

This essay is to make brief comments on the Nitinol vascular stents fatigue lifetime requirements, finite element analysis and fatigue lifetime tests etc.


Assuntos
Prótese Vascular , Análise de Elementos Finitos , Teste de Materiais , Ligas , Stents
3.
Zhongguo Yi Liao Qi Xie Za Zhi ; 31(6): 433-8, 2007 Nov.
Artigo em Zh | MEDLINE | ID: mdl-18269044

RESUMO

With the development of cerebral interventional medical devices, Nitinol alloy has been widely used in clinical fields as a good biomaterial. This essay is to make brief comments on Nitinol alloy's present development, its material characteristics, medical basic researches, and applications in cerebral interventional devices.


Assuntos
Ligas , Materiais Biocompatíveis , Revascularização Cerebral/instrumentação , Stents , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA