Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Org Chem ; 76(7): 2180-6, 2011 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-21384805

RESUMO

Electrospray ionization of methanolic solutions of p-hydroxyphenacyl derivatives HO-C(6)H(4)-C(O)-CH(2)-X (X = leaving group) provides abundant signals for the deprotonated species which are assigned to the corresponding phenolate anions (-)O-C(6)H(4)-C(O)-CH(2)-X. Upon collisional activation in the gas phase, these anions inter alia undergo loss of a neutral "C(8)H(6)O(2)" species concomitant with formation of the corresponding anions X(-). The energies required for the loss of the neutral roughly correlate with the gas phase acidities of the conjugate acids (HX). Extensive theoretical studies performed for X = CF(3)COO in order to reveal the energetically most favorable pathway for the formation of neutral "C(8)H(6)O(2)" suggest three different routes of similar energy demands, involving a spirocyclopropanone, epoxide formation, and a diradical, respectively.


Assuntos
Acetofenonas/química , Ânions/química , Ciclopropanos/química , Compostos de Epóxi/química , Gases Nobres/química , Compostos de Espiro/química , Modelos Teóricos , Estrutura Molecular , Soluções/química , Espectrometria de Massas por Ionização por Electrospray
2.
Eur J Ophthalmol ; 20(4): 719-23, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20099237

RESUMO

PURPOSE: Accumulating evidence indicates that oxidative stress may play an important role in the pathogenesis of type 2 diabetes and its complications. Lycopene, a very potent antioxidant of carotenoids, has received considerable scientific interest in recent years for its potential role in the prevention of oxidative stress-related chronic diseases. This study was undertaken to investigate whether the serum levels of lycopene are altered between type 2 diabetic patients with and without diabetic retinopathy. METHODS: A total of 71 patients with type 2 diabetes were analyzed and compared with 23 nondiabetic healthy controls. Serum lycopene concentrations were assayed using high-performance liquid chromatography. RESULTS: Lycopene level was found to be significantly lower in diabetic patients than in controls (p = 0.021). In the diabetic group, subjects with proliferative diabetic retinopathy had significantly lower lycopene levels than subjects without diabetic retinopathy or with nonproliferative diabetic retinopathy. In the analysis of correlations, hemoglobin A1c were negatively correlated with lycopene (r = -0.345, p = 0.007) after multivariate adjustment. A stepwise linear multiple regression model revealed that age and hemoglobin A1c were significant determinants of lycopene. CONCLUSIONS: Our findings show that measuring serum lycopene is a novel convenient method for evaluating oxidative damage. Diabetic patients, especially those with advanced diabetic retinopathy, had significantly lower serum lycopene levels; this suggests that lycopene may be helpful for the diagnosis, severity, and therapeutic evaluation of diabetic retinopathy.


Assuntos
Carotenoides/sangue , Retinopatia Diabética/sangue , Estresse Oxidativo/fisiologia , Biomarcadores/sangue , Cromatografia Líquida de Alta Pressão , Diabetes Mellitus Tipo 2/sangue , Progressão da Doença , Feminino , Humanos , Licopeno , Masculino , Pessoa de Meia-Idade , Prognóstico
3.
Micromachines (Basel) ; 11(1)2019 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-31861694

RESUMO

This paper details study of the anti-symmetric response to the symmetrical electrostatic excitation of a Micro-electro-mechanical-systems (MEMS) resonant mass sensor. Under higher order mode excitation, two nonlinear coupled flexural modes to describe MEMS mass sensors are obtained by using Hamilton's principle and Galerkin method. Static analysis is introduced to investigate the effect of added mass on the natural frequency of the resonant sensor. Then, the perturbation method is applied to determine the response and stability of the system for small amplitude vibration. Through bifurcation analysis, the physical conditions of the anti-symmetric mode vibration are obtained. The corresponding stability analysis is carried out. Results show that the added mass can change the bifurcation behaviors of the anti-symmetric mode and affect the voltage and frequency of the bifurcation jump point. Typically, we propose a mass parameter identification method based on the dynamic jump motion of the anti-symmetric mode. Numerical studies are introduced to verify the validity of mass detection method. Finally, the influence of physical parameters on the sensitivity of mass sensor is analyzed. It is found that the DC voltage and mass adsorption position are critical to the sensitivity of the sensor. The results of this paper can be potentially useful in nonlinear mass sensors.

4.
Clin EEG Neurosci ; 45(2): 98-103, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23986293

RESUMO

Alzheimer's disease (AD) is the most common cause of dementia. Global field synchronization (GFS) can measure functional synchronization in frequency-domain electroencephalogram (EEG) data. The aim of this study is to explore GFS values and its clinical significance for severity of cognitive decline in AD. EEGs were recorded from 37 AD patients and 37 age-matched healthy individuals. GFS values were calculated in delta, theta, alpha, beta 1, beta 2, beta 3, gamma, and full frequency bands. The Montreal Cognitive Assessment (MoCA) and Clinical Dementia Rating scale (CDR) were employed to assess symptom severity in AD patients. Correlation analysis, clustering analysis, and concordance analysis were performed to analyze the relationship between GFS values and MoCA scores in AD patients. GFS values of the beta 1, beta 2, beta 3, and full bands were lower in AD patients than in healthy individuals, and positively correlated with MoCA and CDR scores in the combined group (AD patients and healthy individuals). GFS values were positively correlated with MoCA socres in 3 beta bands and full bands, and with CDR scores in the delta band. There was a good concordance between K-means clustering algorithm calculating of GFS values and MoCA scoring (κ = .913, P < .001). In conclusion, the present results indicated that GFS can serve as an indicator of cognitive decline or impairment in AD patients. Furthermore, the GFS method of EEG holds considerable promise to distinguish mild cognitive impairment from serious cognitive impairment in patients with AD.


Assuntos
Doença de Alzheimer/fisiopatologia , Transtornos Cognitivos/diagnóstico , Transtornos Cognitivos/fisiopatologia , Sincronização Cortical , Eletroencefalografia , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/complicações , Doença de Alzheimer/diagnóstico , Análise por Conglomerados , Transtornos Cognitivos/etiologia , Sincronização Cortical/fisiologia , Eletroencefalografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA