Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Opt Express ; 29(23): 37234-37244, 2021 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-34808800

RESUMO

Mid-infrared absorption spectroscopy is an effective method for detecting analyte fingerprints without labeling, but the inherent loss of metals in current methods is a main issue. Here, a sensing scheme was proposed that uses an all-dielectric grating metasurface and angular scanning of polarized light, and then it was verified by numerical simulation. The proposed fingerprint detection scheme could effectively couple a guided-mode resonance spectrum peak with the characteristic peak of the analyte's phonon-polariton in the mid-infrared region, significantly enhancing the interaction between light and the analyte. The novel scheme would realize broadband enhancement to detect a variety of substances, and facilitate mid-infrared sensing and analysis of trace substances.

2.
Opt Express ; 28(16): 23748-23760, 2020 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-32752367

RESUMO

In this study, we designed a novel ultra-wideband (UWB) absorber and numerically analyzed it to demonstrate that its light absorptivity was greater than 90% in the wavelength range of visible light and near-infrared (405-1505 nm). The structure of proposed novel UWB absorber consisted of four layers of films, including silica, titanium, magnesium fluoride, and aluminium, and the upper silica and titanium layers had rectangular cubes in them. For that, the excitations of propagating surface plasmon resonance (PSPR), local surface plasmon resonance (LSPR), and the resonance of Fabry-Perot (FP) cavity were generated at the same time and combined to reach the effect of perfect absorption and ultra-wideband. The proposed absorber had an average absorptivity of 95.14% in the wavelength range of 405 ∼ 1505 nm when the light was under normal incidence. In addition, the UWB absorber was large incident angle insensitive and polarization-independent. The absorber proposed in the paper had great prospects in the fields of thermal electronic equipment, solar power generation, and perfect cloaking.

3.
World J Gastrointest Endosc ; 16(3): 117-125, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38577648

RESUMO

Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is a means to procure adequate specimens for histological and cytologic analysis. The ideal EUS-FNA should be safe, accurate, and have a high sample adequacy rate and low adverse events rate. In recent years, many guidelines and trials on EUS-FNA have been published. The purpose of this article is to provide an update on the influence of some of the main factors on the diagnostic efficiency of EUS-FNA as well as a rare but serious complication known as needle tract seeding.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA