J Arthroplasty ; 27(5): 750-7.e2, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22285258

RESUMO

This prospective observational study of 499 patients with hip resurfacing and 255 patients with total hip arthroplasty compared outcomes for 2 years. We used propensity scores to identify matched cohorts of 118 patients with hip resurfacing and 118 patients with total hip arthroplasty. We used these cohorts to compare improvements in the Western Ontario and McMaster University (WOMAC) osteoarthritis index and Medical Outcomes Short-Form 36 physical function component (SF-36 PF) scores at 3 months and at 1 and 2 years postsurgery. Both groups demonstrated significant improvements from baseline in WOMAC and SF-36 PF. Improvements in SF-36 PF were greater for patients with hip resurfacing than for patients with total hip arthroplasty 1 and 2 years postsurgery; improvements in WOMAC were similar for both groups. The clinical significance of this observation needs further investigation.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Articulação do Quadril/fisiopatologia , Articulação do Quadril/cirurgia , Osteoartrite do Quadril/cirurgia , Índice de Massa Corporal , Estudos de Coortes , Comorbidade , Emprego , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Falha de Prótese , Recuperação de Função Fisiológica , Análise de Regressão , Reoperação , Fumar/epidemiologia , Resultado do Tratamento
2.
Proc Inst Mech Eng H ; 228(9): 876-89, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25313024

RESUMO

Implant malalignment in hip arthroplasty increases the risk of revision surgery due to problems such as hip instability, wear, and impingement. Traditional instrumentation lacks accuracy and does not individualize the goal. Computer-assisted surgery (CAS) and patient-specific solutions improve accuracy but add considerably to the cost, amongst other drawbacks. We developed an adjustable mechanical device, called Optihip, which is set to a patient-specific goal preoperatively and is independent of pelvis position intraoperatively. The purpose of the present study was to evaluate Optihip's accuracy ex vivo. Acetabular components were implanted into six cadaveric specimens, 12 hips, by two surgeons, with the device individually adjusted according to preoperative templating on computed tomography (CT) images relative to defined acetabular rim landmarks; options also exist for templating on single or biplanar X-rays. Intraoperatively, the device was positioned on the corresponding anatomical landmarks allowing the insertion of a guide pin, which then defined the desired orientation of the acetabular cup during impaction. Mean absolute difference between the preoperatively planned cup alignment and final acetabular cup orientation, measured from postoperative CT images, was 2.5±1.2° for inclination and 2.5±2.2° for version with maximum values of 4.7° and 6.8°, respectively. Compared with previous in vivo reports, Optihip guided the acetabular cup orientation more accurately than conventional hip arthroplasty, and comparably to CAS or patient-specific systems, while fitting into the normal surgical workflow. Although clinical testing is required to confirm these experimental results, the positive ex vivo accuracy suggests good potential for improving revision rates and patient functional outcome.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Prótese de Quadril , Cirurgia Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/instrumentação , Pinos Ortopédicos , Feminino , Humanos , Masculino , Amplitude de Movimento Articular , Cirurgia Assistida por Computador/instrumentação