Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
BMC Genomics ; 17: 486, 2016 07 09.
Artigo em Inglês | MEDLINE | ID: mdl-27393338

RESUMO

BACKGROUND: The ability to capture and sequence large contiguous DNA fragments represents a significant advancement towards the comprehensive characterization of complex genomic regions. While emerging sequencing platforms are capable of producing several kilobases-long reads, the fragment sizes generated by current DNA target enrichment technologies remain a limiting factor, producing DNA fragments generally shorter than 1 kbp. The DNA enrichment methodology described herein, Region-Specific Extraction (RSE), produces DNA segments in excess of 20 kbp in length. Coupling this enrichment method to appropriate sequencing platforms will significantly enhance the ability to generate complete and accurate sequence characterization of any genomic region without the need for reference-based assembly. RESULTS: RSE is a long-range DNA target capture methodology that relies on the specific hybridization of short (20-25 base) oligonucleotide primers to selected sequence motifs within the DNA target region. These capture primers are then enzymatically extended on the 3'-end, incorporating biotinylated nucleotides into the DNA. Streptavidin-coated beads are subsequently used to pull-down the original, long DNA template molecules via the newly synthesized, biotinylated DNA that is bound to them. We demonstrate the accuracy, simplicity and utility of the RSE method by capturing and sequencing a 4 Mbp stretch of the major histocompatibility complex (MHC). Our results show an average depth of coverage of 164X for the entire MHC. This depth of coverage contributes significantly to a 99.94 % total coverage of the targeted region and to an accuracy that is over 99.99 %. CONCLUSIONS: RSE represents a cost-effective target enrichment method capable of producing sequencing templates in excess of 20 kbp in length. The utility of our method has been proven to generate superior coverage across the MHC as compared to other commercially available methodologies, with the added advantage of producing longer sequencing templates amenable to DNA sequencing on recently developed platforms. Although our demonstration of the method does not utilize these DNA sequencing platforms directly, our results indicate that the capture of long DNA fragments produce superior coverage of the targeted region.


Assuntos
Variação Genética , Genoma Humano , Genômica/métodos , Sequenciamento de Nucleotídeos em Larga Escala , Hibridização Genômica Comparativa/métodos , Primers do DNA , Bases de Dados Genéticas , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Humanos , Complexo Principal de Histocompatibilidade/genética , Hibridização de Ácido Nucleico , Reação em Cadeia da Polimerase em Tempo Real , Análise de Sequência de DNA
2.
Hum Immunol ; 78(10): 642-648, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28732721

RESUMO

BACKGROUND: A simplified protocol for HLA-typing -by NGS, developed for use with the Illumina MiSeq, was performed by technologists with varying NGS experience to assess accuracy and reproducibility. METHODS: Technologists from six laboratories typed the same 16 samples at HLA-A, B, C, DRB1, and DQB1. The protocol includes long range PCR, library preparation, and paired-end 250bp sequencing. Two indexing strategies were employed: locus-specific indexing whereby each locus was tagged uniquely and sample-specific indexing whereby all 5 loci for a sample were pooled prior to library preparation. Sequence analysis was performed with two software packages, Target HLA (Omixon) and NGSengine (GenDx). RESULTS: The average number of sequence reads per library was 387,813; however, analysis was limited to 40,000 reads for locus-indexed libraries and 200,000 reads for sample-indexed libraries resulting in an average depth of coverage of 1444 reads per locus. Sufficient reads for genotype analysis were obtained for 98.4% of libraries. Genotype accuracy was >97% in pooled amplicons and >99% in individual amplicons by both software analysis. Inter-laboratory reproducibility was 99.7% and only cause of discordance was cross-contamination of a single amplicon. CONCLUSIONS: This NGS HLA-typing protocol is simple, reproducible, scalable, highly accurate and amenable to clinical testing.


Assuntos
Genótipo , Antígenos HLA/genética , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Teste de Histocompatibilidade/métodos , Alelos , Estudos de Viabilidade , Biblioteca Gênica , Técnicas de Genotipagem , Interoperabilidade da Informação em Saúde , Humanos , Reação em Cadeia da Polimerase , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA