Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Notf Rett Med ; 24(4): 603-649, 2021.
Artigo em Alemão | MEDLINE | ID: mdl-34093078

RESUMO

The European Resuscitation Council has produced these newborn life support guidelines, which are based on the International Liaison Committee on Resuscitation (ILCOR) 2020 Consensus on Science and Treatment Recommendations (CoSTR) for Neonatal Life Support. The guidelines cover the management of the term and preterm infant. The topics covered include an algorithm to aid a logical approach to resuscitation of the newborn, factors before delivery, training and education, thermal control, management of the umbilical cord after birth, initial assessment and categorisation of the newborn infant, airway and breathing and circulation support, communication with parents, considerations when withholding and discontinuing support.

2.
Notf Rett Med ; 24(4): 274-345, 2021.
Artigo em Alemão | MEDLINE | ID: mdl-34093077

RESUMO

Informed by a series of systematic reviews, scoping reviews and evidence updates from the International Liaison Committee on Resuscitation, the 2021 European Resuscitation Council Guidelines present the most up to date evidence-based guidelines for the practice of resuscitation across Europe. The guidelines cover the epidemiology of cardiac arrest; the role that systems play in saving lives, adult basic life support, adult advanced life support, resuscitation in special circumstances, post resuscitation care, first aid, neonatal life support, paediatric life support, ethics and education.

3.
Neonatology ; : 1-11, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38834044

RESUMO

INTRODUCTION: Laryngeal mask airway (LMA) use in neonatal resuscitation is limited despite existing evidence and recommendations. This survey investigated the knowledge and experience of healthcare providers on the use of the LMA and explored barriers and solutions for implementation. METHODS: This online, cross-sectional survey on LMA in neonatal resuscitation involved healthcare professionals of the Union of European Neonatal and Perinatal Societies (UENPS). RESULTS: A total of 858 healthcare professionals from 42 countries participated in the survey. Only 6% took part in an LMA-specific course. Some delivery rooms were not equipped with LMA (26.1%). LMA was mainly considered after the failure of a face mask (FM) or endotracheal tube (ET), while the first choice was limited to neonates with upper airway malformations. LMA and FM were considered easier to position but less effective than ET, while LMA was considered less invasive than ET but more invasive than FM. Participants felt less competent and experienced with LMA than FM and ET. The lack of confidence in LMA was perceived as the main barrier to its implementation in neonatal resuscitation. More training, supervision, and device availability in delivery wards were suggested as possible actions to overcome those barriers. CONCLUSION: Our survey confirms previous findings on limited knowledge, experience, and confidence with LMA, which is usually considered an option after the failure of FM/ET. Our findings highlight the need for increasing the availability of LMA in delivery wards. Moreover, increasing LMA training and having an LMA expert supervisor during clinical practice may improve the implementation of LMA use in neonatal clinical practice.

4.
Resuscitation ; 161: 291-326, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33773829

RESUMO

The European Resuscitation Council has produced these newborn life support guidelines, which are based on the International Liaison Committee on Resuscitation (ILCOR) 2020 Consensus on Science and Treatment Recommendations (CoSTR) for Neonatal Life Support. The guidelines cover the management of the term and preterm infant. The topics covered include an algorithm to aid a logical approach to resuscitation of the newborn, factors before delivery, training and education, thermal control, management of the umbilical cord after birth, initial assessment and categorisation of the newborn infant, airway and breathing and circulation support, communication with parents, considerations when withholding and discontinuing support.


Assuntos
Reanimação Cardiopulmonar , Recém-Nascido Prematuro , Algoritmos , Consenso , Humanos , Lactente , Recém-Nascido , Ressuscitação
5.
Resuscitation ; 161: 1-60, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33773824

RESUMO

Informed by a series of systematic reviews, scoping reviews and evidence updates from the International Liaison Committee on Resuscitation, the 2021 European Resuscitation Council Guidelines present the most up to date evidence-based guidelines for the practice of resuscitation across Europe. The guidelines cover the epidemiology of cardiac arrest; the role that systems play in saving lives, adult basic life support, adult advanced life support, resuscitation in special circumstances, post resuscitation care, first aid, neonatal life support, paediatric life support, ethics and education.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca , Adulto , Criança , Europa (Continente) , Primeiros Socorros , Parada Cardíaca/terapia , Humanos , Recém-Nascido , Ressuscitação , Revisões Sistemáticas como Assunto
9.
Semin Fetal Neonatal Med ; 10(1): 45-61, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15698970

RESUMO

This chapter aims to provide an overview of aspects of risk management as they might be applied to the practice of resuscitation of the newborn using general principles of risk management and specific standards where they apply. Section 1 considers the matter of hazard and risk and how they may be classified. Figures are presented to provide a clinical perspective on resuscitation with a discussion on the hierarchy of clinical risks operating upon the baby. Section 2 centres on a discussion of those aspects that operate to modify the risks to the baby during a resuscitation, including environmental considerations (location, clinical setting and equipment); staffing issues (establishment, competency, induction and training) and logistics (process, communication and documentation). Section 3 debates the place of cord gases in the context of the diagnosis of perinatal hypoxaemia.


Assuntos
Asfixia Neonatal/prevenção & controle , Neonatologia/normas , Ressuscitação/métodos , Ressuscitação/normas , Gestão de Riscos , Asfixia Neonatal/sangue , Gasometria , Feminino , Sangue Fetal/química , Humanos , Recém-Nascido , Neonatologia/métodos , Gravidez , Reino Unido
10.
Resuscitation ; 54(3): 265-8, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12204460

RESUMO

Manikins currently used in newborn and paediatric resuscitation training are limited in their effectiveness by an inability to allow instructors control over airway patency. This means that attempts to introduce situations that require interventions, other than just appropriate head positioning to achieve successful lung inflation, into training or testing scenarios are compromised by the obvious visual cue of the manikin's chest movement which may occur even when the head is incorrectly positioned. This report describes a modification to manikins, which allows such control and discusses its use in improving the effectiveness of teaching and the learning experience.


Assuntos
Manequins , Ressuscitação/educação , Pré-Escolar , Desenho de Equipamento , Humanos , Lactente , Recém-Nascido
11.
Resuscitation ; 54(2): 175-81, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12161297

RESUMO

Newborn Life Support (NLS) courses use manikins for demonstration and practise of skills required for newborn resuscitation. The aim of this study was to compare currently available manikins for physical characteristics and feedback during psychomotor tasks. Four testers reached a consensus opinion about these features for each of four manikins. Although Laerdal manikins were considered to provide the most realistic airway patency, feedback during mask ventilation and chest compressions, none of the manikins were individually considered to have ideal physical characteristics. Features of the 'ideal' manikin are proposed. Manufacturers should consider these features when developing manikins for training in newborn resuscitation.


Assuntos
Reanimação Cardiopulmonar/educação , Recém-Nascido , Manequins , Humanos , Teste de Materiais , Materiais de Ensino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA