Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 246
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eye Contact Lens ; 50(7): 329-331, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38728248

RESUMO

ABSTRACT: Radial keratotomy (RK) was commonly performed in the 1980s and 1990s. We aimed to clarify the current status of post-RK refractive correction and treatment. We retrospectively reviewed the charts of 70 patients with a history of RK. Of the 70 patients, 44 were identified for clinical outcomes. Refractive or therapeutic intervention (rigid gas-permeable contact lens fit, spectacle prescription, corneal surgery, and use of pilocarpine hydrochloride for photophobia) was possible in 59% of patients with postoperative visual deterioration after RK; in the remaining 41%, therapeutic intervention was not possible. Rigid gas-permeable contact lens fit for corneal irregular astigmatism was the most common refractive intervention and was effective in 36% of cases in the university hospital.


Assuntos
Ceratotomia Radial , Acuidade Visual , Humanos , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Idoso , Astigmatismo/cirurgia , Astigmatismo/fisiopatologia , Refração Ocular/fisiologia , Seguimentos , Lentes de Contato , Adulto Jovem
2.
Eye Contact Lens ; 50(1): 16-22, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37732884

RESUMO

OBJECTIVES: To characterize higher-order aberrations (HOAs) in different severities of keratoconus (KC) from the anterior and posterior corneal surfaces and whole eye using an integrated Scheimpflug corneal tomographer/Hartmann-Shack wavefront aberrometer. METHODS: This study included eyes with clinical KC, topographic KC (no clinical signs), fellow eyes with very asymmetric ectasia with normal topography and no clinical signs (VAE-NT), and control eyes. Corneal and ocular wavefront aberrations were obtained using an integrated Scheimpflug tomographer/Hartmann-Shack wavefront aberrometer. The diagnostic capability of distinguishing VAE-NT from the control was also tested. RESULTS: This study included 68 eyes with clinical KC, 44 with topographic KC, 26 with VAE-NT, and 45 controls. Clinical KC had significantly greater total HOAs and coma from the anterior and posterior corneal surfaces and whole eye than the other groups ( P <0.05). Although topographic KC had significantly greater values in all wavefront parameters than the control ( P <0.05), ocular and corneal HOAs did not differ between the VAE-NT and control groups. The coma from the anterior cornea in topographic KC was significantly greater than that in VAE-NT ( P <0.05); the coma from the posterior cornea and whole eye did not differ. Total HOAs from the anterior corneal surface exhibited the highest area under the receiver operating characteristic curve value of 0.774 (sensitivity, 73%; specificity, 78%). CONCLUSION: A comprehensive wavefront assessment can be used to quantitatively evaluate corneal and ocular HOAs across various severity of KC. Total HOAs from the anterior corneal surface exhibited the potential ability in distinguishing VAE-NT from the control eyes.


Assuntos
Aberrações de Frente de Onda da Córnea , Ceratocone , Humanos , Ceratocone/diagnóstico , Coma , Topografia da Córnea , Córnea , Curva ROC , Aberrações de Frente de Onda da Córnea/diagnóstico
3.
Graefes Arch Clin Exp Ophthalmol ; 261(3): 761-767, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36178505

RESUMO

PURPOSE: To evaluate the corneal biomechanical features of eyes with granular corneal dystrophy type 2 (GCD2) by analyzing corneal biomechanical indices obtained using a Corvis ST (CST) dynamic ultra-high-speed Scheimpflug imaging device. METHODS: In this retrospective case-control study, 35 CST parameters were compared in normal eyes (control) and eyes of patients with GCD2 treated at Osaka University Hospital, Osaka, Japan. The parameters included the Corvis Biomechanical Index (CBI), which is important in differentiating eyes with keratoconus from normal eyes. We measured the deposition rates of lesions in the central 7-mm region of the eye and assessed the correlation between the deposition rate and the CBI. RESULTS: Twenty-one eyes with GCD2 and 23 control eyes were analyzed. Eyes with GCD2 showed significantly less corneal stiffness in 15 CST parameters than did control eyes. In particular, the CBI was remarkably higher in eyes with GCD2 than in control eyes (P = 0.000006). Additionally, the deposition rate and the CBI were positively correlated. CONCLUSIONS: GCD2 eyes had softer corneas than did control eyes in most biomechanical CST parameters, and one of the parameters (the CBI) was linked to the rate of deposited lesions. Since IOP may be underestimated in GCD2 eyes, management should be especially careful in GCD2 cases complicated by glaucoma.


Assuntos
Córnea , Ceratocone , Humanos , Estudos Retrospectivos , Estudos de Casos e Controles , Elasticidade , Ceratocone/diagnóstico , Fenômenos Biomecânicos , Topografia da Córnea/métodos
4.
Eye Contact Lens ; 49(3): 98-103, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36729105

RESUMO

OBJECTIVES: To assess agreement between measurements of ocular wavefront aberrations obtained using the Pentacam AXL Wave (Oculus Optikgeräte GmbH) (Aberrometer A) and KR-1W (Topcon Corp) (Aberrometer B), both of which are based on the Hartmann-Shack principle. METHODS: In this prospective case-control study, ocular wavefront aberrations measurements were obtained using both aberrometers in patients with keratoconus (KC) and control participants. Ocular wavefront aberrations were measured through the natural pupil without dilation using both devices in a dark room. For both aberrometers, accommodation was inhibited by automatically adding fogging. The individual Zernike coefficients from the second to fourth order were compared between the two aberrometers for a 4-mm pupil diameter. RESULTS: Twenty-six KC and 29 control eyes were assessed. Statistically significant correlations ( P <0.05) were observed for all Zernike coefficients, except for Z 4-2 in the control group. Bland-Altman analysis indicated good agreement between aberrometers and no statistically significant differences in the control group. However, in the KC group, patterns of proportional error were observed in vertical coma Z 3-1 (r=0.338, P =0.008), trefoil Z 4-4 (r=0.701, P =0.003), secondary astigmatism Z 4-2 (r=0.348, P =0.025), and spherical aberrations Z 40 (r=0.407, P =0.012). CONCLUSIONS: The Zernike coefficient values measured by the two aberrometers were well correlated in the control and KC groups. However, in eyes with KC, Aberrometer B tended to present greater values in several Zernike coefficients than Aberrometer A, suggesting that wavefront measurements obtained using the two aberrometers are not interchangeable in patients with KC.


Assuntos
Ceratocone , Refração Ocular , Humanos , Estudos de Casos e Controles , Acuidade Visual , Pupila , Transtornos da Visão
5.
Eye Contact Lens ; 49(6): 258-261, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37200044

RESUMO

ABSTRACT: We retrospectively examined corneal refractive power in three patients who had been followed up for more than 20 years after radial keratotomy (RK) with microperforations (MPs). All patients underwent RK in both eyes and were referred to our clinic because of postoperative decreased vision. MP was observed in five of the six eyes at the initial visit. The corneal refractive power of the anterior and posterior surfaces of the 6-mm-diameter cornea was examined using Fourier analysis based on corneal shape analysis using anterior segment optical coherence tomography. The spherical components decreased in all three cases. The asymmetry and higher-order irregularity components and fluctuations in corneal refractive power were markedly greater in the two cases with MP in both eyes. Fluctuations in corneal refractive power were observed at more than 20 years after RK with MP. Therefore, careful observation is necessary, even after a long-term postoperative follow-up period.


Assuntos
Ceratotomia Radial , Humanos , Ceratotomia Radial/métodos , Estudos Retrospectivos , Córnea/cirurgia , Período Pós-Operatório
6.
Eye Contact Lens ; 49(11): 483-488, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37713280

RESUMO

OBJECTIVES: To evaluate the optical quality of different toric contact lens (CL) designs and compare their on-eye visual correction performance. METHODS: Twenty soft CL wearers aged 20 to 39 years were enrolled. Two daily disposable silicone-hydrogel toric CLs were tested: the "Eyelid Stabilized Design" (ESD-CL) and prism-ballast design (PB-CL); a spherical daily disposable silicone hydrogel CL (spherical CL) was used as a control. On-eye performance was compared for corrected distance visual acuity (CDVA), astigmatism, and ocular higher-order aberrations (HOAs); astigmatism and ocular HOAs were measured with a wavefront sensor. The subjective quality of vision, rated for "blurred vision" and "double vision," lens rotation, and fitting were also compared. RESULTS: The ESD-CLs, PB-CL, and no-CL provided better CDVA than spherical CL ( P <0.05). Compared with spherical CL and no CL, PB-CL and ESD-CLs caused significantly lesser astigmatism ( P <0.05). Coma was significantly lesser with ESD-CLs than that with PB-CL ( P <0.05); total HOAs did not differ among the four conditions. The subjective ratings for blurred and double vision were significantly lower with ESD-CLs than those with spherical CL ( P <0.05). CONCLUSIONS: Toric CLs provide a better CDVA than spherical CLs. However, differences in coma and subjective symptoms may occur because of the design of toric CLs.


Assuntos
Astigmatismo , Lentes de Contato Hidrofílicas , Humanos , Astigmatismo/terapia , Diplopia , Coma , Hidrogéis , Silicones , Refração Ocular
7.
Chem Biodivers ; 20(4): e202200924, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36929088

RESUMO

The hepatitis E virus (HEV) causes a common infectious disease that infects pigs, wild boars, deer, and humans. In most cases, humans are infected by eating raw meat. Some essential oils have been reported to exhibit antiviral activities. In this study, in order to investigate the anti-HEV properties of essential oils, the immunoreactivities of HEV antigen proteins against the relevant antibodies were analyzed after the HEV antigens underwent treatment with various essential oils. The essential oils extracted from the tea tree, which was previously reported to exhibit antiviral activity, lavender, and lemon had strongly reduced activity. We found that treatment with the essential oil prepared from Sakhalin spruce was associated with the strongest reduction in immunoreactivity of HEV antigen protein(s) among the tested substances. The main volatile constituents of Sakhalin spruce essential oil were found to be bornyl acetate (32.30 %), α-pinene (16.66 %), camphene (11.14 %), camphor (5.52 %), ß-phellandrene (9.09 %), borneol (4.77 %), and limonene (4.57 %). The anti-HEV properties of the various components of the essential oils were examined: treatment with bornyl acetate, the main component of Sakhalin spruce oil, α-pinene, the main component of tea tree oil, and limonene, the main component of lemon oil, resulted in a strong reduction in HEV antigen immunoreactivity. These results indicate that each main component of the essential oils plays an important role in the reduction of the immunoreactivity of HEV antigen protein(s); they also suggest that Sakhalin spruce essential oil exhibits anti-HEV activity. In a formulation with the potential to eliminate the infectivity of HEV in foodborne infections, this essential oil can be applied as an inactivating agent for meat processing and cooking utensils, such as knives and chopping boards.


Assuntos
Cervos , Vírus da Hepatite E , Óleos Voláteis , Picea , Animais , Suínos , Humanos , Óleos Voláteis/farmacologia , Limoneno , Antivirais
8.
J Sci Food Agric ; 103(11): 5609-5615, 2023 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-37066700

RESUMO

BACKGROUND: It is reported that broilers with 'wooden breast' have poor processing properties, such as low binding and water-holding capacities. However, the reason for the poor functional characteristics has not been clarified. In this study, myosin was extracted from a wooden breast. Its physicochemical properties were investigated to clarify the relationship between the structure and physicochemical properties of the heating gel of myosin obtained from the wooden breast. RESULTS: The turbidity of myosin solution extracted from wooden breast increased with increase in the heat treatment to a higher value than that from the normal breast meat myosin. The solubility of myosin collected from a wooden breast after heating decreased like normal breast muscle myosin. The surface hydrophobicity of myosin removed from wooden breast increased continually above 60 °C, unlike the change in surface hydrophobicity of normal breast myosin. The free thiol group of myosin extracted from the wooden breast was higher than normal breast myosin before and after heating. The apparent elasticity of heat-induced gels and chicken meat sausages was significantly lower in sausages and gel with wooden breast than normal ones (P < 0.05). The microstructure of the heated gel of normal myosin showed a fine network structure. In contrast, the heat-induced gel of wooden breast-extracted myosin showed a structure with loosely connected aggregates and many gaps. CONCLUSION: The coarseness of the internal gel structure of myosin extracted from wooden breast was shown to affect the apparent elasticity of the gel and sausages made from the chicken meat. © 2023 Society of Chemical Industry.


Assuntos
Galinhas , Temperatura Alta , Animais , Galinhas/fisiologia , Miosinas/química , Músculos Peitorais , Géis/química
9.
Artigo em Inglês | MEDLINE | ID: mdl-35973649

RESUMO

The growth rate of broiler chickens has increased by 400% over the past 50 years, and breast yields continue to increase. This has led to an increase in thoracic muscle abnormalities in broilers, with wooden breast becoming a major issue worldwide. The etiology and the mechanism underlying the etiology of wooden breasts have not yet been elucidated; however, it occurs due to oxidative stress. Reactive oxygen species, which cause oxidative stress, are mainly produced in mitochondria. Thus, in this study, we investigated the relationship between the severity of wooden breast in broilers and the characteristics of mitochondria as the source of reactive oxygen species. Sampling of the pectoralis major muscle at the ventral cranial position was conducted in 50-day-old broilers. The severity of wooden breast was classified into three groups based on the muscle fiber roundness and wing-wing contact test, with highest severity in severe wooden breast and lowest severity in normal breast. Nicotinamide adenine dinucleotide tetrazolium reductase staining revealed an increase in darkly stained muscle fibers, indicating high severity of wooden breast. The mitochondria were swollen in severe wooden breast cases, with highest swelling in severe wooden breast and lowest swelling in normal breast. The expression levels of the mitochondrial antioxidant enzyme genes superoxide dismutase 1 and superoxide dismutase 2 were significantly lower in wooden breast-severe tissue than in normal tissue. These results suggest that when the levels of reactive oxygen species in muscle fibers, which should be constant, are increased, mitochondrial homeostasis is not maintained and the damage levels increase in various membranes of the cell, leading to the disruption of normal physiological functions.


Assuntos
Doenças Musculares , Doenças das Aves Domésticas , Animais , Galinhas/metabolismo , Mitocôndrias/metabolismo , Doenças Musculares/genética , Doenças Musculares/metabolismo , Doenças Musculares/veterinária , Músculos Peitorais/metabolismo , Doenças das Aves Domésticas/metabolismo , Espécies Reativas de Oxigênio/metabolismo
10.
Eye Contact Lens ; 48(6): 256-260, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35333804

RESUMO

OBJECTIVES: To characterize higher-order aberrations (HOAs) in clinical and subclinical keratoconus (KC). METHODS: The study included 33, 36, and 26 patients with clinical, topographic (no clinical signs), and pretopographic (normal topography and no clinical signs) KC and 30 controls. Ocular and corneal HOAs for the 4-mm pupils were measured using a wavefront sensor and expanded up to the sixth order of Zernike polynomials. The magnitudes of trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were calculated via Zernike vector analysis and used as HOA parameters along with total HOAs. Area under the receiver operating characteristic curve (AUROC) values for each wavefront parameter for pretopographic KC were compared. RESULTS: Control eyes and eyes with pretopographic KC had significantly lower ocular or corneal total HOAs and Zernike vector terms than those with clinical KC and topographic KC, except for ocular tetrafoil between topographic KC and pretopographic KC and spherical aberration among all groups. The AUROCs for corneal total HOAs and corneal coma for pretopographic KC and control eyes were 0.781 (100% sensitivity and 47% specificity) and 0.735 (73% sensitivity and 73% specificity), respectively. CONCLUSION: Corneal total HOAs and corneal coma exhibited a potential ability to discriminate pretopographic KC from normal control eyes.


Assuntos
Aberrações de Frente de Onda da Córnea , Ceratocone , Coma , Córnea , Topografia da Córnea , Aberrações de Frente de Onda da Córnea/diagnóstico , Humanos , Ceratocone/diagnóstico , Pupila
11.
Ophthalmology ; 128(11): e142-e152, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33221325

RESUMO

The purpose of this review is to evaluate the usefulness of corneal topography to select premium intraocular lenses (IOLs), including aspherical IOLs, toric IOLs, and multifocal IOLs, in refractive cataract surgery. Corneal topography can detect corneal regular astigmatism, corneal irregular astigmatism (higher-order aberrations [HOAs]) including spherical aberration, and corneal shape abnormalities after corneal refractive surgery. Surgeons can explain to the patients with significant corneal HOAs about its effect on postoperative visual function before surgery. Multifocal IOLs should not be selected for such eyes. For eyes with abnormal corneal shape, appropriate IOL power calculation formulae can be applied. In the case of toric IOLs, regular astigmatism and corneal HOAs should be checked. Before implanting an aspheric IOL, it is ideal to confirm spherical aberration of the cornea is not below the normal range. Because corneal HOAs, abnormal corneal shape after corneal refractive surgery, corneal regular astigmatism, and corneal spherical aberration increase postoperative refractive errors and poor vision quality with premium IOLs, corneal topography before cataract surgery is helpful in screening patients who are not appropriate candidates for premium IOLs.


Assuntos
Extração de Catarata , Córnea/diagnóstico por imagem , Topografia da Córnea/métodos , Lentes Intraoculares , Refração Ocular/fisiologia , Procedimentos Cirúrgicos Refrativos , Córnea/cirurgia , Humanos
12.
Eye Contact Lens ; 47(9): 511-514, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34424224

RESUMO

PURPOSE: To characterize very asymmetric keratoconus (KC) in terms of clinical demographics and risk factors in the Japanese population. METHODS: We retrospectively reviewed the clinical records of patients with very asymmetric KC attending a university hospital. Patients with very asymmetric KC had defined clinical KC in one eye and normal topography in the fellow eye. All patients completed a questionnaire on potential risk factors (family history of KC, atopy, asthma, allergy, heart disease, sleep apnea, Down syndrome, eye rubbing, prone sleep position, and dominant hand). These data were compared with those of patients with clinical or topographic KC in both eyes. Subgroup analysis of very asymmetric KC eyes were performed based on the KC status: mild and severe. RESULTS: We retrospectively investigated 66 patients with very asymmetric KC and 505 patients with KC. Patients reported eye rubbing (53%-56%), allergy (62%-63%), and atopy (28%-29%) in both groups. There was no significant difference in terms of risk factors between the two groups. Approximately half of the 66 patients with very asymmetric KC had KC eyes ipsilateral to the dominant hand. Subgroup analysis of very asymmetric KC showed that atopy and asthma were more frequent in the mild KC group than in the severe KC group. Forty-four of 60 patients (73.3%) were using corneal, rigid, gas-permeable contact lenses (corneal GPs) for the KC eye, of which 30 patients (68.2%) were also using a corneal GP for the fellow eye. CONCLUSIONS: The patient-reported frequency of eye rubbing, allergy, and atopy were similar between KC and very asymmetric KC. Furthermore, we found no association between hand dominance and KC laterality.


Assuntos
Ceratocone , Córnea , Topografia da Córnea , Humanos , Ceratocone/epidemiologia , Ceratocone/etiologia , Estudos Retrospectivos , Fatores de Risco
13.
Eye Contact Lens ; 45(3): 188-194, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30550406

RESUMO

OBJECTIVES: To evaluate corneal irregular astigmatism due to the anterior corneal surface using Fourier harmonic analysis with a Placido ring-based corneal topographer (Placido-based topographer) and three-dimensional anterior segment optical coherence tomography (OCT) in dry eyes. METHODS: Forty-four eyes of 44 subjects with dry eye and 20 eyes of 20 normal control subjects were enrolled. Corneal topographic data were obtained using a Placido-based topographer and OCT. Dioptric data from the central 3-mm zone of the anterior corneal surface were decomposed using Fourier harmonic analysis. Spherical, regular astigmatism, and irregular astigmatism (asymmetry and higher-order irregularity) refractive error components of the cornea from the two imaging modalities were compared. RESULTS: Both asymmetry and higher-order irregularity values were significantly greater in dry eyes than in control eyes for both the Placido-based topographer and OCT measurements (all P<0.05). In dry eyes, measured values of asymmetry and higher-order irregularities were significantly smaller when obtained with OCT than with the Placido-based topographer (both P<0.001). By contrast, these parameters were not significantly different between the two devices in control eyes. In dry eyes, severity of superficial punctate keratopathy in the central corneal region was correlated with irregular astigmatism. CONCLUSIONS: The amount of corneal irregular astigmatism, quantified using Fourier harmonic analysis, was significantly higher in dry eyes than in normal eyes. Measurements obtained with OCT and the Placido-based topographer differed in subjects with dry eyes. Therefore, caution should be practiced when trying to use these measurements interchangeably.


Assuntos
Astigmatismo/etiologia , Córnea/patologia , Topografia da Córnea , Síndromes do Olho Seco/complicações , Tomografia de Coerência Óptica , Adulto , Astigmatismo/diagnóstico , Feminino , Análise de Fourier , Humanos , Masculino , Pessoa de Meia-Idade , Lágrimas/fisiologia
14.
Int J Mol Sci ; 19(6)2018 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-29789502

RESUMO

BACKGROUND: Dystrophin Dp71 is one of the isoforms produced by the DMD gene which is mutated in patients with Duchenne muscular dystrophy (DMD). Although Dp71 is expressed ubiquitously, it has not been detected in normal skeletal muscle. This study was performed to assess the expression of Dp71 in human skeletal muscle. METHODS: Human skeletal muscle RNA and tissues were obtained commercially. Mouse skeletal muscle was obtained from normal and DMDmdx mice. Dp71 mRNA and protein were determined by reverse-transcription PCR and an automated capillary Western assay system, the Simple Western, respectively. Dp71 was over-expressed or suppressed using a plasmid expressing Dp71 or antisense oligonucleotide, respectively. RESULTS: Full-length Dp71 cDNA was PCR amplified as a single product from human skeletal muscle RNA. A ca. 70 kDa protein peak detected by the Simple Western was determined as Dp71 by over-expressing Dp71 in HEK293 cells, or suppressing Dp71 expression with antisense oligonucleotide in rhabdomyosarcoma cells. The Simple Western assay detected Dp71 in the skeletal muscles of both normal and DMD mice. In human skeletal muscle, Dp71 was also detected. The ratio of Dp71 to vinculin of human skeletal muscle samples varied widely, indicating various levels of Dp71 expression. CONCLUSIONS: Dp71 protein was detected in human skeletal muscle using a highly sensitive capillary Western blotting system.


Assuntos
Distrofina/metabolismo , Músculo Esquelético/metabolismo , Animais , Linhagem Celular Tumoral , Células Cultivadas , Distrofina/genética , Células HEK293 , Humanos , Camundongos , Camundongos Endogâmicos C57BL , Vinculina/genética , Vinculina/metabolismo
15.
Int Ophthalmol ; 37(6): 1279-1288, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27896533

RESUMO

PURPOSE: To investigate prospectively the characteristics in the higher-order aberrations and anterior segment tomography in patients with pathologic myopia. METHODS: One hundred and twelve consecutive highly myopic patients (mean age 43.4 ± 9.3 years, spherical equivalent of refractive error ≥8 D and an axial length ≥26.5 mm) were studied. Thirty-seven emmetropic individuals (mean age 37.0 ± 14.5 years, spherical equivalent of refractive error ≤ ±1 D) were analyzed as controls. The ocular and cornea higher-order aberrations were measured using a Hartmann-Shack wavefront sensor (KR-1W; Topcon Corporation, Tokyo, Japan). The crystalline lens rise, the angle-to-angle, and the white-to-white values were measured using anterior segment OCT (SS-1000; Tomey Corporation, Nagoya, Japan). The mean curvature of the anterior corneal surface, the thickness at the thinnest central corneal point, the location of the central corneal point, the corneal volume, the anterior chamber volume, and the anterior chamber depth were measured using the Pentacam HR (Oculus, Inc., Wetzlar, Germany). RESULTS: The ocular total higher-order aberration for 4-mm pupil, the ocular spherical aberrations, and internal spherical aberration for 6-mm pupil were significantly higher in highly myopic eyes than in the emmetropic controls. The crystalline lens rise was significantly smaller in highly myopic eyes than in the emmetropic controls. The anterior chamber depth and the anterior chamber volume were significantly larger in highly myopic eyes than in the emmetropic controls. CONCLUSION: Highly myopic eyes had higher-order aberrations than emmetropic eyes because of the increasing internal aberrations.


Assuntos
Segmento Anterior do Olho/patologia , Miopia/patologia , Erros de Refração/patologia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Câmara Anterior/patologia , Comprimento Axial do Olho/patologia , Estudos de Casos e Controles , Aberrações de Frente de Onda da Córnea/patologia , Emetropia/fisiologia , Feminino , Humanos , Cristalino/patologia , Masculino , Pessoa de Meia-Idade , Miopia/diagnóstico por imagem , Adulto Jovem
17.
Ophthalmology ; 123(12): 2474-2480, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27769585

RESUMO

PURPOSE: To evaluate the accuracy of a new formula for predicting postoperative anterior chamber depth (ACD) with preoperative angle-to-angle (ATA) depth using anterior segment (AS) optical coherence tomography (OCT) and to compare it with established methods. DESIGN: Retrospective consecutive case series. PARTICIPANTS: Three hundred four eyes (276 patients) implanted with acrylic intraocular lenses (IOLs) were divided randomly into a training set (152 eyes) and a validation set (152 eyes). METHODS: Based on the training set data, the postoperative ACD measured 1 month after surgery was analyzed via multiple linear regression analysis with 5 preoperatively measured variables: ATA depth, ATA width, preoperative ACD measured with AS OCT, axial length (AL), and corneal power. A new regression formula for predicting postoperative ACD was developed using the results of the stepwise analysis. In the validation set data, the coefficients of determination (R2) between the measured postoperative ACD and the predicted postoperative ACD obtained using the new formula were compared with those obtained using the Sanders-Retzlaff-Kraff theoretic (SRK/T) and Haigis formulas. The absolute prediction errors were compared with each formula. MAIN OUTCOME MEASURES: Postoperative ACD, median absolute prediction error of postoperative ACD, and ocular biometric parameters. RESULTS: In the training set, ATA depth yielded the highest standard partial regression coefficient value, indicating that ATA depth is the most effective parameter for predicting postoperative ACD. The new regression formula was developed with 3 variables; ATA depth, preoperative ACD, and AL. In the validation set, the postoperative ACDs of the new formula, the SRK/T formula, and Haigis formula were predicted with R2 of 0.71, 0.36, and 0.55, respectively, and the medians of the absolute prediction errors were 0.10 mm, 0.65 mm, and 0.30 mm, respectively. The absolute prediction error with the new formula was significantly smaller than those obtained with the SRK/T and Haigis formulas (P < 0.0001). CONCLUSIONS: The new formula with 3 preoperative parameters-ATA depth, preoperative ACD, and AL-predicted postoperative ACD more accurately than the SRK/T and Haigis formulas. It may be possible to improve the accuracy of IOL power calculation using an improved postoperative ACD prediction with the ATA depth measured by AS OCT.


Assuntos
Algoritmos , Câmara Anterior/patologia , Lentes Intraoculares , Tomografia de Coerência Óptica/métodos , Idoso , Idoso de 80 Anos ou mais , Câmara Anterior/diagnóstico por imagem , Biometria/métodos , Extração de Catarata , Corpo Ciliar/diagnóstico por imagem , Corpo Ciliar/patologia , Feminino , Humanos , Iris/diagnóstico por imagem , Iris/patologia , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Óptica e Fotônica , Período Pós-Operatório , Análise de Regressão , Reprodutibilidade dos Testes , Estudos Retrospectivos , Malha Trabecular/diagnóstico por imagem , Malha Trabecular/patologia
18.
Graefes Arch Clin Exp Ophthalmol ; 254(10): 1999-2004, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27515941

RESUMO

PURPOSE: The purpose of this study was to evaluate visual function and postoperative refractive errors in patients with granular corneal dystrophy type 2 (GCD2) and cataracts who underwent photorefractive keratectomy (PRK) instead of phototherapeutic keratectomy (PTK) following cataract surgery to avoid PTK-induced central island formation and reduce refractive errors after cataract surgery. METHODS: The medical records of 14 eyes from nine patients (one man and eight women; mean age, 69.0 ± 8.5 years) with GCD2 and cataracts were evaluated. All patients underwent PTK using the PRK mode 3 months after cataract surgery. We analyzed corrected distance visual acuity (CDVA), refractive errors, and corneal astigmatism derived from Fourier analysis and assessed the incidence of complications in cataract surgery and PTK. RESULTS: The mean CDVA logMAR values were 0.42 ± 0.19, 0.38 ± 0.18, and 0.16 ± 0.12 before and after cataract surgery and after PTK, respectively. CDVA improved significantly after PTK, as compared with both before and after cataract surgery (P < 0.001). The mean absolute errors after cataract surgery and PTK were 0.53 ± 0.43 and 1.61 ± 1.01 diopters, respectively. Pre- and postoperative Fourier indices did not significantly vary in the 3-mm diameter zone, and only the asymmetry component of the 6-mm diameter zone significantly (P <0.01) increased postoperatively. No central island formation and no other marked complications were observed postoperatively in any case. CONCLUSIONS: Performing PTK using the PRK mode following cataract surgery may be effective for patients with GCD2 and cataracts.


Assuntos
Distrofias Hereditárias da Córnea/cirurgia , Miopia/cirurgia , Ceratectomia Fotorrefrativa , Idoso , Idoso de 80 Anos ou mais , Catarata/fisiopatologia , Distrofias Hereditárias da Córnea/fisiopatologia , Topografia da Córnea , Feminino , Análise de Fourier , Humanos , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Miopia/fisiopatologia , Facoemulsificação , Refração Ocular/fisiologia , Tomografia de Coerência Óptica , Resultado do Tratamento , Acuidade Visual/fisiologia
19.
Eye Contact Lens ; 42(5): 333-8, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26783977

RESUMO

Quality of vision has been emphasized in ophthalmologic clinical practice in recent years. The optical or visual performance of the human eye is not static and fluctuates over time. Considering the major origins of temporal fluctuations in optical or visual performance, quantitative assessment of the dynamic changes in the optical quality of the entire eye is important. This review provides an overview of the clinical application of the objective methods for assessing dynamic changes in optical quality, particularly those associated with accommodation, the precorneal tear film, the prelens tear film, and contact lens movement and fitting.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Transtornos da Visão , Visão Ocular/fisiologia , Acomodação Ocular/fisiologia , Lentes de Contato , Humanos , Ajuste de Prótese , Lágrimas/fisiologia , Transtornos da Visão/diagnóstico , Transtornos da Visão/fisiopatologia , Transtornos da Visão/reabilitação
20.
Eye Contact Lens ; 42(4): 250-5, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26383772

RESUMO

OBJECTIVES: To noninvasively investigate regional differences in tear film stability and meibomian glands in patients with aqueous-deficient dry eye. METHODS: Forty-nine dry eyes and 31 normal eyes were analyzed. A corneal topographer with a tear film scanning function was used for noninvasive tear film break-up time (NI-TFBUT) measurements and meibomian gland observations. The NI-TFBUT values and location of the first tear film break-up point were recorded in four quadrants. Meibomian gland loss was graded for each eyelid using meiboscores. Lid margin abnormality was scored from zero to four according to the number of existing abnormalities. The NI-TFBUT values and meiboscores were compared between two groups, and regional differences in NI-TFBUT values and meiboscores were analyzed. Also, the correlation between the NI-TFBUT and ocular surface examination results were investigated. RESULTS: The NI-TFBUT values and meiboscores were significantly lower and higher, respectively, for the dry eye group than for the normal group. In the dry eye group, the occurrence rate for first tear film break-up was the highest in the inferior nasal quadrant, and the mean meiboscore was significantly higher for the upper eyelids than for the lower eyelids. The NI-TFBUT and lid margin abnormality scores showed a weak negative correlation, and the NI-TFBUT values and meiboscores showed no correlation. CONCLUSIONS: Compared to normal eyes, aqueous-deficient dry eyes show significant regional differences in tear film stability and meibomian glands. Considering these regional differences, the overall observation of the ocular surface, including both upper and lower eyelids, will aid clinicians in understanding this condition better.


Assuntos
Topografia da Córnea/instrumentação , Topografia da Córnea/métodos , Síndromes do Olho Seco/fisiopatologia , Glândulas Tarsais/patologia , Lágrimas/diagnóstico por imagem , Idoso , Técnicas de Diagnóstico Oftalmológico/normas , Síndromes do Olho Seco/diagnóstico , Feminino , Fluorofotometria/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Lágrimas/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA