Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 18(8)2018 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-30096818

RESUMO

The application of gas sensors in breath analysis is an important trend in the early diagnostics of different diseases including lung cancer, ulcers, and enteric infection. However, traditional methods of synthesis of metal oxide gas-sensing materials for semiconductor sensors based on wet sol-gel processes give relatively high sensitivity of the gas sensor to changing humidity. The sol-gel process leading to the formation of superficial hydroxyl groups on oxide particles is responsible for the strong response of the sensing material to this factor. In our work, we investigated the possibility to synthesize metal oxide materials with reduced sensitivity to water vapors. Dry synthesis of SnO2 nanoparticles was implemented in gas phase by spark discharge, enabling the reduction of the hydroxyl concentration on the surface and allowing the production of tin dioxide powder with specific surface area of about 40 m²/g after annealing at 610 °C. The drop in sensor resistance does not exceed 20% when air humidity increases from 40 to 100%, whereas the response to 100 ppm of hydrogen is a factor of 8 with very short response time of about 1 s. The sensor response was tested in mixtures of air with hydrogen, which is the marker of enteric infections and the marker of early stage fire, and in a mixture of air with lactate (marker of stomach cancer) and ammonia gas (marker of Helicobacter pylori, responsible for stomach ulcers).


Assuntos
Testes Respiratórios/instrumentação , Testes Respiratórios/métodos , Gases/análise , Gases/química , Umidade , Nanopartículas Metálicas/química , Nanomedicina/métodos , Óxidos/química , Ar/análise , Amônia/análise , Incêndios , Humanos , Hidrogênio/análise , Ácido Láctico/análise , Neoplasias Gástricas/diagnóstico , Úlcera Gástrica/diagnóstico
2.
Sensors (Basel) ; 10(12): 11156-73, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-22163518

RESUMO

We present a multisensor designed for industrial compressed air diagnostics and combining the measurement of pressure, flow, and temperature, integrated with the corresponding signal conditioning electronics in a single low-temperature co-fired ceramic (LTCC) package. The developed sensor may be soldered onto an integrated electro-fluidic platform by using standard surface mount device (SMD) technology, e.g., as a standard electronic component would be on a printed circuit board, obviating the need for both wires and tubes and thus paving the road towards low-cost integrated electro-fluidic systems. Several performance aspects of this device are presented and discussed, together with electronics design issues.


Assuntos
Técnicas Biossensoriais/instrumentação , Ar Comprimido , Eletrônica/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Biossensoriais/métodos , Cerâmica/química , Temperatura Baixa , Desenho de Equipamento/métodos , Humanos , Hidrodinâmica , Técnicas Analíticas Microfluídicas/métodos , Modelos Biológicos , Pressão , Processamento de Sinais Assistido por Computador/instrumentação , Temperatura
4.
Phys Rev E Stat Nonlin Soft Matter Phys ; 79(2 Pt 1): 020104, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19391696

RESUMO

We evaluate the percolation threshold values for a realistic model of continuum segregated systems, where random spherical inclusions forbid the percolating objects, modeled by hardcore spherical particles surrounded by penetrable shells, to occupy large regions inside the composite. We find that the percolation threshold is generally a nonmonotonous function of segregation, and that an optimal (i.e., minimum) critical concentration exists well before maximum segregation is reached. We interpret this feature as originating from a competition between reduced available volume effects and enhanced concentrations needed to ensure percolation in the highly segregated regime. The relevance with existing segregated materials is discussed.

5.
J Biomech ; 40(8): 1709-15, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17094997

RESUMO

Ligament balancing in total knee arthroplasty may have an important influence on joint stability and prosthesis lifetime. In order to provide quantitative information and assistance during ligament balancing, a device that intraoperatively measures knee joint forces and moments was developed. Its performance and surgical advantages were evaluated on six cadaver specimens mounted on a knee joint loading apparatus allowing unconstrained knee motion as well as compression and varus-valgus loading. Four different experiments were performed on each specimen. (1) Knee joints were axially loaded. Comparison between applied and measured compressive forces demonstrated the accuracy and reliability of in situ measurements (1.8N). (2) Assessment of knee stability based on condyle contact forces or varus-valgus moments were compared to the current surgical method (difference of varus-valgus loads causing condyle lift-off). The force-based approach was equivalent to the surgical method while the moment-based, which is considered optimal, showed a tendency of lateral imbalance. (3) To estimate the importance of keeping the patella in its anatomical position during imbalance assessment, the effect of patellar eversion on the mediolateral distribution of tibiofemoral contact forces was measured. One fourth of the contact force induced by the patellar load was shifted to the lateral compartment. (4) The effect of minor and major medial collateral ligament releases was biomechanically quantified. On average, the medial contact force was reduced by 20% and 46%, respectively. Large variation among specimens reflected the difficulty of ligament release and the need for intraoperative force monitoring. This series of experiments thus demonstrated the device's potential to improve ligament balancing and survivorship of total knee arthroplasty.


Assuntos
Artroplastia do Joelho/instrumentação , Fenômenos Biomecânicos/instrumentação , Articulação do Joelho/fisiopatologia , Modelos Biológicos , Patela/fisiopatologia , Ligamento Patelar/fisiopatologia , Transdutores , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos/métodos , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Técnicas In Vitro , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estresse Mecânico
6.
MethodsX ; 4: 305-309, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29159136

RESUMO

A method for determining the critical values of the flow speed and the flow constriction degree characteristic of the alignment of cylindrical nano-objects in a flowing suspension is proposed. Previously, the alignment process of cylindrical nano-objects in suspensions was investigated by using birefringence of the polarized light and the small-angle X-ray scattering. While both methods are suitable for measuring the alignment degree of cylindrical nano-objects in suspensions diluted down to low concentrations, they are restricted for the application to undiluted concentrated suspensions because of non-transparency and multiple scattering of X-rays. In addition, the use of the second method requires an expensive synchrotron equipment. We present a simple and faster method based on the direct ultrasound attenuation measurements of longitudinal viscosity of a suspension containing cylindrical nano-objects, which decreases monotonically, approaching its asymptotic value with increase in the flow speed and the flow constriction degree. The principle and advantages of the proposed method are as follows: •The cylindrical nano-objects align along an accelerated flow at overcritical values of the flow speed and the constriction degree.•The critical values correspond to the state of a suspension possessing viscosity close to the asymptotic value.•The method is applicable to undiluted concentrated suspensions, including opaque ones.

7.
IEEE Trans Biomed Eng ; 52(9): 1609-11, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16189974

RESUMO

To improve the ligament balancing procedure during total knee arthroplasty a force-sensing device to intraoperatively measure knee joint forces and moments has been developed. It consists of two sensitive plates, one for each condyle, a tibial base plate and a set of spaces to adapt the device thickness to the patient-specific tibiofemoral gap. Each sensitive plate is equipped with three deformable bridges instrumented with thick-film piezoresistive sensors, which allow accurate measurements of the amplitude and location of the tibiofemoral contact forces. The net varus-valgus moment is then computed to characterize the ligamentous imbalance. The developed device has a measurement range of 0-500 N and an intrinsic accuracy of 0.5% full scale. Experimental trials on a plastic knee joint model and on a cadaver specimen demonstrated the proper function of the device in situ. The results obtained indicated that the novel force-sensing device has an appropriate range of measurement and a strong potential to offer useful quantitative information and effective assistance during the ligament balancing procedure in total knee arthroplasty.


Assuntos
Artroplastia do Joelho/instrumentação , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Ligamentos/fisiopatologia , Ligamentos/cirurgia , Modelos Biológicos , Ajuste de Prótese/instrumentação , Transdutores de Pressão , Artroplastia do Joelho/métodos , Cadáver , Simulação por Computador , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Técnicas In Vitro , Ajuste de Prótese/métodos , Estresse Mecânico
8.
Lab Chip ; 15(2): 563-74, 2015 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-25422101

RESUMO

The development of microreactors that operate under harsh conditions is always of great interest for many applications. Here we present a microfabrication process based on low-temperature co-fired ceramic (LTCC) technology for producing microreactors which are able to perform chemical processes at elevated temperature (>400 °C) and against concentrated harsh chemicals such as sodium hydroxide, sulfuric acid and hydrochloric acid. Various micro-scale cavities and/or fluidic channels were successfully fabricated in these microreactors using a set of combined and optimized LTCC manufacturing processes. Among them, it has been found that laser micromachining and multi-step low-pressure lamination are particularly critical to the fabrication and quality of these microreactors. Demonstration of LTCC microreactors with various embedded fluidic structures is illustrated with a number of examples, including micro-mixers for studies of exothermic reactions, multiple-injection microreactors for ionone production, and high-temperature microreactors for portable hydrogen generation.

9.
ACS Appl Mater Interfaces ; 7(33): 18803-14, 2015 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-26244330

RESUMO

With growing public interest in portable electronics such as micro fuel cells, micro gas total analysis systems, and portable medical devices, the need for miniaturized air pumps with minimal electrical power consumption is on the rise. Thus, the development and downsizing of next-generation thermal transpiration gas pumps has been investigated intensively during the last decades. Such a system relies on a mesoporous membrane that generates a thermomolecular pressure gradient under the action of an applied temperature bias. However, the development of highly miniaturized active membrane materials with tailored porosity and optimized pumping performance remains a major challenge. Here we report a systematic study on the manufacturing of aerogel membranes using an optimized, minimal-shrinkage sol-gel process, leading to low thermal conductivity and high air conductance. This combination of properties results in superior performance for miniaturized thermomolecular air pump applications. The engineering of such aerogel membranes, which implies pore structure control and chemical surface modification, requires both chemical processing know-how and a detailed understanding of the influence of the material properties on the spatial flow rate density. Optimal pumping performance was found for devices with integrated membranes with a density of 0.062 g cm(-3) and an average pore size of 142.0 nm. Benchmarking of such low-density hydrophobic active aerogel membranes gave an air flow rate density of 3.85 sccm·cm(-2) at an operating temperature of 400 °C. Such a silica aerogel membrane based system has shown more than 50% higher pumping performance when compared to conventional transpiration pump membrane materials as well as the ability to withstand higher operating temperatures (up to 440 °C). This study highlights new perspectives for the development of miniaturized thermal transpiration air pumps while offering insights into the fundamentals of molecular pumping in three-dimensional open-mesoporous materials.


Assuntos
Gases/química , Géis/química , Sistemas Microeletromecânicos/métodos , Dióxido de Silício/química , Sistemas Microeletromecânicos/instrumentação , Miniaturização , Espectroscopia de Infravermelho com Transformada de Fourier , Temperatura , Condutividade Térmica
13.
IEEE Trans Neural Syst Rehabil Eng ; 16(6): 582-91, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19144590

RESUMO

We have developed a robotic interface to train hand and finger function. HandCARE is a Cable-Actuated REhabilitation system, in which each finger is attached to an instrumented cable loop allowing force control and a predominantly linear displacement. The device, whose designed is based on biomechanical measurements, can assist the subject in opening and closing movements and can be adapted to accommodate various hand shapes and finger sizes. Main features of the interface include a differential sensing system, and a clutch system which allows independent movement of the five fingers with only one actuator. The device is safe, easily transportable, and offers multiple training possibilities. This paper presents the biomechanical measurements carried out to determine the requirements for a finger rehabilitation device, and the design and characterization of the complete system.


Assuntos
Mãos/fisiopatologia , Sistemas Homem-Máquina , Transtornos dos Movimentos/fisiopatologia , Transtornos dos Movimentos/reabilitação , Robótica/instrumentação , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral/fisiopatologia , Terapia Assistida por Computador/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Transtornos dos Movimentos/etiologia , Robótica/métodos , Acidente Vascular Cerebral/complicações , Terapia Assistida por Computador/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA