Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Anal Bioanal Chem ; 408(15): 3943-52, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27032409

RESUMO

In this contribution, we propose a label-free immunosensor, based on a novel type of electrolyte-gated field-effect transistor (EGOFET), for ultrasensitive detection of the C-reactive protein (CRP). The recognition layer of the biosensor is fabricated by physical adsorption of the anti-CRP monoclonal antibody onto a poly-3-hexyl thiophene (P3HT) organic semiconductor surface. A supplementary nonionic hydrophilic polymer is used as a blocking agent preventing nonspecific interactions and allowing a better orientation of the antibodies immobilized onto the P3HT surface. The whole biomolecule immobilization procedure does not require any pretreatment of the organic semiconductor surface, and the whole functionalization process is completed in less than 30 min. Surface plasmon resonance (SPR) measurements were performed to assess the amount of biomolecules physisorbed onto the P3HT and to evaluate the CRP binding proprieties of the deposited anti-CRP layer. A partial surface coverage of about 23 % of adsorbed antibody molecules was found to most efficiently sense the CRP. The electrical performance of the EGOFET immunosensor was comparable to that of a bare P3HT EGOFET device, and the obtained CRP calibration curve was linear over six orders of magnitude (from 4 pM to 2 µM). The relative standard deviation of the individual calibration points, measured on immunosensors fabricated on different chips, ranged between 1 and 14 %, and a detection limit of 2 pM (220 ng/L) was established. The novel electronic immunosensor is compatible with low-cost fabrication procedures and was successfully employed for the detection of the CRP biomarker in the clinically relevant matrix serum. Graphical abstract Schematic of the EGOFET immunosensor for CRP detection. The anti-CRP monoclonal antibody layer is physisorbed on the P3HT organic semiconductor and the CRP is directly measured by a label-free electronic EGOFET transducer.


Assuntos
Técnicas Biossensoriais/métodos , Proteína C-Reativa/análise , Imunoensaio/métodos , Adsorção , Anticorpos/química , Anticorpos Imobilizados , Técnicas Biossensoriais/instrumentação , Eletrólitos/química , Imunoensaio/instrumentação , Limite de Detecção , Semicondutores , Tiofenos/química
2.
Anal Chem ; 87(22): 11337-44, 2015 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-26489723

RESUMO

A general method to obtain the efficient entrapment of mixtures of glycoenzymes in calcium alginate hydrogel is proposed in this paper. As a proof of principle, three glycoenzymes acting in series (trehalase, glucose oxidase, and horseradish peroxidase) have been coimmobilized in calcium alginate beads. The release of the enzymes from the hydrogel mesh (leakage) is avoided by exploiting the enzyme's aggregation induced by the concanavalin A. The aggregation process has been monitored by dynamic light scattering technique, while both enzyme encapsulation efficiency and leakage have been quantified spectrophotometrically. Obtained data show an encapsulation efficiency above 95% and a negligible leakage from the beads when enzyme aggregates are larger than 300 nm. Operational stability of "as prepared" beads has been largely improved by a coating of alternated shells of polycation poly(diallyldimethylammonium chloride) and of alginate. As a test for the effectiveness of the overall procedure, analytical bioassays exploiting the enzyme-containing beads have been developed for the optical determination of glucose and trehalose, and limit of detection values of 0.2 and of 40 µM, respectively, have been obtained.


Assuntos
Alginatos/metabolismo , Bioensaio , Enzimas Imobilizadas/metabolismo , Glucose Oxidase/metabolismo , Peroxidase do Rábano Silvestre/metabolismo , Trealase/metabolismo , Alginatos/química , Enzimas Imobilizadas/química , Glucose Oxidase/química , Ácido Glucurônico/química , Ácido Glucurônico/metabolismo , Ácidos Hexurônicos/química , Ácidos Hexurônicos/metabolismo , Peroxidase do Rábano Silvestre/química , Tamanho da Partícula , Propriedades de Superfície , Trealase/química
3.
Proc Natl Acad Sci U S A ; 109(17): 6429-34, 2012 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-22493224

RESUMO

Biosystems integration into an organic field-effect transistor (OFET) structure is achieved by spin coating phospholipid or protein layers between the gate dielectric and the organic semiconductor. An architecture directly interfacing supported biological layers to the OFET channel is proposed and, strikingly, both the electronic properties and the biointerlayer functionality are fully retained. The platform bench tests involved OFETs integrating phospholipids and bacteriorhodopsin exposed to 1-5% anesthetic doses that reveal drug-induced changes in the lipid membrane. This result challenges the current anesthetic action model relying on the so far provided evidence that doses much higher than clinically relevant ones (2.4%) do not alter lipid bilayers' structure significantly. Furthermore, a streptavidin embedding OFET shows label-free biotin electronic detection at 10 parts-per-trillion concentration level, reaching state-of-the-art fluorescent assay performances. These examples show how the proposed bioelectronic platform, besides resulting in extremely performing biosensors, can open insights into biologically relevant phenomena involving membrane weak interfacial modifications.

4.
Angew Chem Int Ed Engl ; 54(43): 12562-76, 2015 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-26420480

RESUMO

Thin-film transistors can be used as high-performance bioelectronic devices to accomplish tasks such as sensing or controlling the release of biological species as well as transducing the electrical activity of cells or even organs, such as the brain. Organic, graphene, or zinc oxide are used as convenient printable semiconducting layers and can lead to high-performance low-cost bioelectronic sensing devices that are potentially very useful for point-of-care applications. Among others, electrolyte-gated transistors are of interest as they can be operated as capacitance-modulated devices, because of the high capacitance of their charge double layers. Specifically, it is the capacitance of the biolayer, being lowest in a series of capacitors, which controls the output current of the device. Such an occurrence allows for extremely high sensitivity towards very weak interactions. All the aspects governing these processes are reviewed here.


Assuntos
Técnicas Biossensoriais/métodos , Eletrônica Médica/métodos , Impressão/métodos , Transistores Eletrônicos , Animais , Técnicas Biossensoriais/instrumentação , Capacitância Elétrica , Eletrólitos/química , Eletrônica Médica/instrumentação , Desenho de Equipamento , Grafite/química , Humanos , Impressão/instrumentação , Termodinâmica , Óxido de Zinco/química
5.
Chem Soc Rev ; 42(22): 8612-28, 2013 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-24018860

RESUMO

The functioning principles of electronic sensors based on organic semiconductor field-effect transistors (OFETs) are presented. The focus is on biological sensors but also chemical ones are reviewed to address general features. The field-induced electronic transport and the chemical and biological interactions for the sensing, each occurring at the relevant functional interface, are separately introduced. Once these key learning points have been acquired, the combined picture for the FET electronic sensing is proposed. The perspective use of such devices in point-of-care is introduced, after some basics on analytical biosensing systems are provided as well. This tutorial review includes also a necessary overview of the OFET sensing structures, but the focus will be on electronic rather than electrochemical detection. The differences among the structures are highlighted along with the implications on the performance level in terms of key analytical figures of merit such as: repeatability, sensitivity and selectivity.

6.
Sensors (Basel) ; 14(9): 16869-80, 2014 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-25215940

RESUMO

Bottom- and top-contact organic thin film transistors (OTFTs) were fabricated, using poly(3-hexylthiophene-2,5-diyl) (P3HT) and poly[2,5-bis(3-tetradecylthiophen-2-yl)thieno[3,2-b]thiophene] (PBTTT-C16) as p-type channel semiconductors. Four different types of OTFTs were fabricated and investigated as gas sensors against three volatile organic compounds, with different associated dipole moments. The OTFT-based sensor responses were evaluated with static and transient current measurements. A comparison between the different architectures and the relative organic semiconductor was made.


Assuntos
Condutometria/instrumentação , Eletrodos , Gases/química , Membranas Artificiais , Polímeros/química , Tiofenos/química , Transistores Eletrônicos , Desenho de Equipamento , Análise de Falha de Equipamento , Compostos Orgânicos Voláteis/análise
7.
Anal Chem ; 85(8): 3849-57, 2013 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-23323705

RESUMO

A Functional Bio-Interlayer Organic Field-Effect Transistor (FBI-OFET) sensor, embedding a streptavidin protein capturing layer, capable of performing label-free selective electronic detection of biotin at 3 part per trillion (mass fraction) or 15 pM, is proposed here. The response shows a logarithmic dependence spanning over 5 orders of magnitude of analyte concentration. The optimization of the FBI analytical performances is achieved by depositing the capturing layer through a controllable Layer-by-Layer (LbL) assembly, while an easy processable spin-coating deposition is proposed for potential low-cost production of equally highly performing sensors. Furthermore, a Langmuirian adsorption based model allows rationalizing the analyte binding process to the capturing layer. The FBI-OFET device is shown to operate also with an antibody interlayer as well as with an ad hoc designed microfluidic system. These occurrences, along with the proven extremely high sensitivity and selectivity, open to FBI-OFETs consideration as disposable electronic strip-tests for assays in biological fluids requiring very low detection limits.


Assuntos
Biotina/análise , Técnicas Eletroquímicas/instrumentação , Estreptavidina/química , Adsorção , Anticorpos/química , Técnicas Eletroquímicas/métodos , Corantes Fluorescentes , Proteínas Imobilizadas/química , Cinética , Técnicas Analíticas Microfluídicas , Fitas Reagentes , Sensibilidade e Especificidade , Transistores Eletrônicos
8.
Top Curr Chem ; 341: 133-76, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23715635

RESUMO

Differentiation of enantiomers remains one of the most attractive and important research areas in analytical chemistry due to its impact on pharmaceutical, chemical, biotechnology, and food industries. For a long time chiral separation techniques, such as high performance liquid chromatography (HPLC), gas chromatography (GC), and capillary electrophoresis (CE), have represented the gold standard for the separation and determination of enantiomers. These techniques, besides being time consuming and expensive, are also not suitable for real time analysis. Therefore, the development of fast and reliable chiral sensors remains a challenge to achieve on-line analysis of enantiomers in both gas and liquid samples. The scope of this chapter is to provide an overview on the basic functioning principles, as well as on the performance level, of solid-state sensing devices for enantiomers differentiation. Particular attention is paid to work providing a set of analytical figures of merit (sensitivity, repeatability, reproducibility, limit-of-detection, etc.) as well as to studies involving miniaturized (or miniaturizable) analytical devices that can deliver real-time, on-line, and label-free information on chiral compounds.

9.
Anal Bioanal Chem ; 402(5): 1799-811, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22189629

RESUMO

Most of the success of electronic devices fabricated to actively interact with a biological environment relies on the proper choice of materials and efficient engineering of surfaces and interfaces. Organic materials have proved to be among the best candidates for this aim owing to many properties, such as the synthesis tunability, processing, softness and self-assembling ability, which allow them to form surfaces that are compatible with biological tissues. This review reports some research results obtained in the development of devices which exploit organic materials' properties in order to detect biologically significant molecules as well as to trigger/capture signals from the biological environment. Among the many investigated sensing devices, organic field-effect transistors (OFETs), organic electrochemical transistors (OECTs) and microcantilevers (MCLs) have been chosen. The main factors motivating this choice are their label-free detection approach, which is particularly important when addressing complex biological processes, as well as the possibility to integrate them in an electronic circuit. Particular attention is paid to the design and realization of biocompatible surfaces which can be employed in the recognition of pertinent molecules as well as to the research of new materials, both natural and inspired by nature, as a first approach to environmentally friendly electronics.


Assuntos
Materiais Biocompatíveis , Técnicas Biossensoriais/instrumentação , Transistores Eletrônicos , Técnicas Biossensoriais/métodos , Eletroquímica/instrumentação , Eletroquímica/métodos , Sistemas Microeletromecânicos/instrumentação , Fenômenos de Química Orgânica
10.
Front Microbiol ; 13: 722900, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35154048

RESUMO

Primary productivity in the Ross Sea region is characterized by intense phytoplankton blooms whose temporal and spatial distribution are driven by changes in environmental conditions as well as interactions with the bacterioplankton community. However, the number of studies reporting the simultaneous diversity of the phytoplankton and bacterioplankton in Antarctic waters are limited. Here, we report data on the bacterial diversity in relation to phytoplankton community structure in the surface waters of the Ross Sea during the Austral summer 2017. Our results show partially overlapping bacterioplankton communities between the stations located in the Terra Nova Bay (TNB) coastal waters and the Ross Sea Open Waters (RSOWs), with a dominance of members belonging to the bacterial phyla Bacteroidetes and Proteobacteria. In the TNB coastal area, microbial communities were characterized by a higher abundance of sequences related to heterotrophic bacterial genera such as Polaribacter spp., together with higher phytoplankton biomass and higher relative abundance of diatoms. On the contrary, the phytoplankton biomass in the RSOW were lower, with relatively higher contribution of haptophytes and a higher abundance of sequences related to oligotrophic and mixothrophic bacterial groups like the Oligotrophic Marine Gammaproteobacteria (OMG) group and SAR11. We show that the rate of diversity change between the two locations is influenced by both abiotic (salinity and the nitrogen to phosphorus ratio) and biotic (phytoplankton community structure) factors. Our data provide new insight into the coexistence of the bacterioplankton and phytoplankton in Antarctic waters, suggesting that specific rather than random interaction contribute to the organic matter cycling in the Southern Ocean.

11.
Anal Bioanal Chem ; 391(6): 2127-34, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18488206

RESUMO

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is a useful technique for the identification of bacteria on the basis of their characteristic protein mass spectrum fingerprint. Highly standardized instrumental analytical performance and bacterial culture conditions are required to achieve useful information. A chemometric approach based on multivariate analysis techniques was developed for the analysis of MALDI data of different bacteria to allow their identification from their fingerprint. Principal component analysis, linear discriminant analysis (LDA) and soft independent modelling of class analogy (SIMCA) were applied to the analysis of the MALDI MS mass spectra of two pathogenic bacteria, Escherichia coli O157:H7 and Yersinia enterocolitica, and the non-pathogenic E. coli MC1061. Spectra variability was assessed by growing bacteria in different media and analysing them at different culture growth times. After selection of the relevant variables, which allows the evaluation of an m/z value pattern with high discriminant power, the identification of bacteria by LDA and SIMCA was performed independently of the experimental conditions used. In order to better evaluate the analytical performance of the approach used, the ability to correctly classify different bacteria, six wild-type strains of E. coli O157:H7, was also studied and a combination of different chemometric techniques with a severe validation was developed. The analysis of spiked bovine meat samples and the agreement with an independent chemiluminescent enzyme immunoassay demonstrated the applicability of the method developed for the detection of bacteria in real samples. The easy automation of the MALDI method and the ability of multivariate techniques to reduce interlaboratory variability associated with bacterial growth time and conditions suggest the usefulness of the proposed MALDI MS approach for rapid routine food safety checks.


Assuntos
Bactérias/isolamento & purificação , Técnicas de Tipagem Bacteriana/métodos , Microbiologia de Alimentos , Carne/microbiologia , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Animais , Bactérias/classificação , Bovinos , Ensaio de Imunoadsorção Enzimática , Escherichia coli , Escherichia coli O157 , Medições Luminescentes , Yersinia enterocolitica
12.
World J Gastroenterol ; 13(7): 1079-84, 2007 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-17373743

RESUMO

AIM: To develop a new formulation with hydroxy propyl methyl cellulose and Shellac coating for extended and selective delivery of butyrate in the ileo-caecal region and colon. METHODS: One-gram sodium butyrate coated tablets containing 13C-butyrate were orally administered to 12 healthy subjects and 12 Crohn's disease patients and the rate of 13C-butyrate absorption was evaluated by 13CO2 breath test analysis for eight hours. Tauroursodeoxycholic acid (500 mg) was co-administered as a biomarker of oro-ileal transit time to determine also the site of release and absorption of butyrate by the time of its serum maximum concentration. RESULTS: The coated formulation delayed the 13C-butyrate release by 2-3 h with respect to the uncoated tablets. Sodium butyrate was delivered in the intestine of all subjects and a more variable transit time was found in Crohn's disease patients than in healthy subjects. The variability of the peak 13CO2 in the kinetic release of butyrate was explained by the inter-subject variability in transit time. However, the coating chosen ensured an efficient release of the active compound even in patients with a short transit time. CONCLUSION: Simultaneous evaluation of breath 13CO2 and tauroursodeoxycholic acid concentration-time curves has shown that the new oral formulation consistently releases sodium butyrate in the ileo-cecal region and colon both in healthy subjects and Crohn's disease patients with variable intestinal transit time. This formulation may be of therapeutic value in inflammatory bowel disease patients due to the appropriate release of the active compound.


Assuntos
Butiratos/administração & dosagem , Butiratos/metabolismo , Ceco/metabolismo , Colo/metabolismo , Íleo/metabolismo , Administração Oral , Adolescente , Adulto , Idoso , Butiratos/uso terapêutico , Dióxido de Carbono/metabolismo , Isótopos de Carbono , Química Farmacêutica , Doença de Crohn/tratamento farmacológico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sódio/administração & dosagem , Sódio/metabolismo , Sódio/uso terapêutico , Comprimidos com Revestimento Entérico , Ácido Tauroquenodesoxicólico/sangue
13.
J Agric Food Chem ; 55(13): 4933-9, 2007 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-17530767

RESUMO

A simple and rapid multiplexed sandwich chemiluminescent enzyme immunoassay has been developed for the simultaneous detection of Escherichia coli O157:H7, Yersinia enterocolitica, Salmonella typhimurium, and Listeria monocytogenes. To achieve the multiplexed detection of the four pathogens, a new polystyrene 96 well microtiter plate format has been designed, in which each main well contains four subwells in the bottom. The monoclonal antibodies specific for each bacteria were separately immobilized in each subwell. When the samples were added to the main wells, the bacteria able to specifically bind to the corresponding monoclonal antibody were captured in one of the four subwells. Subsequently, a mixture of peroxidase-labeled polyclonal antibodies against the four bacteria was added and the peroxidase activity of the bound polyclonal labeled antibodies in each well was measured by an enhanced luminol-based chemiluminescent cocktail using a low-light charge-coupled imaging device. The assay was simple and fast, and the limit of quantification was in the order of 104-105 CFU/mL for all bacterial species. The accuracy of the method, evaluated by comparison of the results with a conventional culturing methodology, was satisfactory, with recovery values ranging from 90 to 120%. This method can be used as a screening test to evaluate the presence of these pathogen bacteria in different foodstuffs.


Assuntos
Escherichia coli O157/isolamento & purificação , Microbiologia de Alimentos , Técnicas Imunoenzimáticas/métodos , Listeria monocytogenes/isolamento & purificação , Salmonella typhimurium/isolamento & purificação , Yersinia enterocolitica/isolamento & purificação , Medições Luminescentes
14.
Sci Rep ; 6: 28085, 2016 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-27312768

RESUMO

The study of proteins confined on a surface has attracted a great deal of attention due to its relevance in the development of bio-systems for laboratory and clinical settings. In this respect, organic bio-electronic platforms can be used as tools to achieve a deeper understanding of the processes involving protein interfaces. In this work, biotin-binding proteins have been integrated in two different organic thin-film transistor (TFT) configurations to separately address the changes occurring in the protein-ligand complex morphology and dipole moment. This has been achieved by decoupling the output current change upon binding, taken as the transducing signal, into its component figures of merit. In particular, the threshold voltage is related to the protein dipole moment, while the field-effect mobility is associated with conformational changes occurring in the proteins of the layer when ligand binding occurs. Molecular Dynamics simulations on the whole avidin tetramer in presence and absence of ligands were carried out, to evaluate how the tight interactions with the ligand affect the protein dipole moment and the conformation of the loops surrounding the binding pocket. These simulations allow assembling a rather complete picture of the studied interaction processes and support the interpretation of the experimental results.


Assuntos
Técnicas Biossensoriais/métodos , Biotina/metabolismo , Proteínas de Transporte/metabolismo , Técnicas Biossensoriais/instrumentação , Biotina/química , Proteínas de Transporte/química , Simulação de Dinâmica Molecular , Ligação Proteica , Conformação Proteica , Semicondutores , Propriedades de Superfície
15.
J Agric Food Chem ; 53(9): 3300-5, 2005 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-15853363

RESUMO

A fast and ultrasensitive chemiluminescent enzyme immunoassay for aflatoxin M(1) in milk samples has been developed and validated. The method is an indirect competitive type format involving the immobilization of an aflatoxin M(1)-bovine serum albumin conjugate on 384 well black polystyrene microtiter plates and the use of a secondary antibody labeled with horseradish peroxidase detected with a luminol-based substrate. Aflatoxin M(1) standard solutions were prepared in milk-based buffer, and milk samples were analyzed without any cleanup procedure. The limit of quantification was 1 ppt, the coefficient of variation was below 9% for both intra- and interassay precision, and the recovery ranged from 96 to 122%. The method is specific, and other aflatoxins do not significantly cross-react with the antibody. Twenty-four milk samples were analyzed, and a good correlation was observed (y = 0.98x + 1.71, r(2) = 0.98, n = 24) when the data were compared with a reference high-performance liquid chromatography method with a fluorescent detector. The developed method is suitable for an accurate, sensitive, and high-throughput screening of aflatoxin M(1) in milk samples with a reduction of costs and increased detectability, as compared with previously developed immunoassays.


Assuntos
Aflatoxina M1/análise , Técnicas Imunoenzimáticas/métodos , Medições Luminescentes/métodos , Leite/química , Animais , Cromatografia Líquida de Alta Pressão , Sensibilidade e Especificidade
16.
Adv Mater ; 27(46): 7528-51, 2015 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-25429859

RESUMO

This review aims to provide an update on the development involving dielectric/organic semiconductor (OSC) interfaces for the realization of biofunctional organic field-effect transistors (OFETs). Specific focus is given on biointerfaces and recent technological approaches where biological materials serve as interlayers in back-gated OFETs for biosensing applications. Initially, to better understand the effects produced by the presence of biomolecules deposited at the dielectric/OSC interfacial region, the tuning of the dielectric surface properties by means of self-assembled monolayers is discussed. Afterward, emphasis is given to the modification of solid-state dielectric surfaces, in particular inorganic dielectrics, with biological molecules such as peptides and proteins. Special attention is paid on how the presence of an interlayer of biomolecules and bioreceptors underneath the OSC impacts on the charge transport and sensing performance of the device. Moreover, naturally occurring materials, such as carbohydrates and DNA, used directly as bulk gating materials in OFETs are reviewed. The role of metal contact/OSC interface in the overall performance of OFET-based sensors is also discussed.


Assuntos
Técnicas Biossensoriais/instrumentação , Transistores Eletrônicos , Técnicas Biossensoriais/métodos , Carboidratos/química , DNA/química , Eletrodos , Proteínas/química , Semicondutores , Dióxido de Silício/química
17.
Nat Commun ; 6: 6010, 2015 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-25591754

RESUMO

Peripheral events in olfaction involve odorant binding proteins (OBPs) whose role in the recognition of different volatile chemicals is yet unclear. Here we report on the sensitive and quantitative measurement of the weak interactions associated with neutral enantiomers differentially binding to OBPs immobilized through a self-assembled monolayer to the gate of an organic bio-electronic transistor. The transduction is remarkably sensitive as the transistor output current is governed by the small capacitance of the protein layer undergoing minute changes as the ligand-protein complex is formed. Accurate determination of the free-energy balances and of the capacitance changes associated with the binding process allows derivation of the free-energy components as well as of the occurrence of conformational events associated with OBP ligand binding. Capacitance-modulated transistors open a new pathway for the study of ultra-weak molecular interactions in surface-bound protein-ligand complexes through an approach that combines bio-chemical and electronic thermodynamic parameters.


Assuntos
Capacitância Elétrica , Receptores Odorantes/química , Receptores Odorantes/metabolismo , Ligação Proteica , Estereoisomerismo , Transistores Eletrônicos
18.
Adv Mater ; 27(5): 911-6, 2015 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-25376989

RESUMO

Electrolyte-gated organic field-effect transistors are successfully used as biosensors to detect binding events occurring at distances from the transistor electronic channel that are much larger than the Debye length in highly concentrated solutions. The sensing mechanism is mainly capacitive and is due to the formation of Donnan's equilibria within the protein layer, leading to an extra capacitance (CDON) in series to the gating system.


Assuntos
Técnicas Biossensoriais/instrumentação , Compostos Orgânicos/química , Transistores Eletrônicos , Avidina/química , Eletrólitos/química , Modelos Moleculares , Conformação Molecular , Concentração Osmolar , Estreptavidina/química , Tiofenos/química
19.
ACS Nano ; 8(8): 7834-45, 2014 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-25077939

RESUMO

An organic field-effect transistor (OFET) integrating bacteriorhodopsin (bR) nanoassembled lamellae is proposed for an in-depth study of the proton translocation processes occurring as the bioelectronic device is exposed either to light or to low concentrations of general anesthetic vapors. The study involves the morphological, structural, electrical, and spectroscopic characterizations necessary to assess the functional properties of the device as well as the bR biological activity once integrated into the functional biointerlayer (FBI)-OFET structure. The electronic transduction of the protons phototranslocation is shown as a current increase in the p-type channel only when the device is irradiated with photons known to trigger the bR photocycle, while Raman spectroscopy reveals an associated C═C isomer switch. Notably, higher energy photons bring the cis isomer back to its trans form, switching the proton pumping process off. The investigation is extended also to the study of a PM FBI-OFET exposed to volatile general anesthetics such as halothane. In this case an electronic current increase is seen upon exposure to low, clinically relevant, concentrations of anesthetics, while no evidence of isomer-switching is observed. The study of the direct electronic detection of the two different externally triggered proton translocation effects allows gathering insights into the underpinning of different bR molecular switching processes.


Assuntos
Bacteriorodopsinas/química , Nanotecnologia/instrumentação , Prótons , Transistores Eletrônicos , Halobacterium salinarum/citologia , Isomerismo , Luz , Modelos Moleculares , Polímeros/química , Conformação Proteica , Membrana Purpúrea/química , Tiofenos/química
20.
Faraday Discuss ; 174: 383-98, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25485906

RESUMO

Among the metal oxide semiconductors, ZnO has been widely investigated as a channel material in thin-film transistors (TFTs) due to its excellent electrical properties, optical transparency and simple fabrication via solution-processed techniques. Herein, we report a solution-processable ZnO-based thin-film transistor gated through a liquid electrolyte with an ionic strength comparable to that of a physiological fluid. The surface morphology and chemical composition of the ZnO films upon exposure to water and phosphate-buffered saline (PBS) are discussed in terms of the operation stability and electrical performance of the ZnO TFT devices. The improved device characteristics upon exposure to PBS are associated with the enhancement of the oxygen vacancies in the ZnO lattice due to Na(+) doping. Moreover, the dissolution kinetics of the ZnO thin film in a liquid electrolyte opens the possible applicability of these devices as an active element in "transient" implantable systems.


Assuntos
Fosfatos/química , Transistores Eletrônicos , Água/química , Óxido de Zinco/química , Adsorção , Eletrólitos/química , Tamanho da Partícula , Soluções , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA