Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Clin Microbiol ; 59(1)2020 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-33115842

RESUMO

Testing of staphylococci other than Staphylococcus aureus (SOSA) for mecA-mediated resistance is challenging. Isolates of Staphylococcus capitis, Staphylococcus haemolyticus, Staphylococcus hominis, and Staphylococcus warneri were evaluated by cefoxitin and oxacillin broth microdilution (BMD), disk diffusion (DD), and PBP2a immunoassay, and the results were compared to mecA PCR results. No phenotypic susceptibility test correlated well with PCR results across all species, although the PBP2a immunoassay yielded 100% correlation. Oxacillin BMD testing by current Clinical and Laboratory Standards Institute (CLSI) SOSA breakpoints led to 2.1% very major errors (VMEs) and 7.1% major errors (ME). Adjusting this breakpoint up by a dilution (susceptible, ≤0.5 µg/ml; resistant, ≥1.0 µg/ml) led to 2.8% VMEs and 0.3% MEs. Among species evaluated, S. haemolyticus had unacceptable VMEs with this new breakpoint (6.4%), as did S. hominis (4.0%). MEs were acceptable by this new breakpoint, ranging from 0 to 1.2%. Oxacillin DD yielded high ME rates (20.7 to 21.7%) using CLSI or European Committee on Antimicrobial Susceptibility Testing breakpoints. VMEs ranged from 0 to 5.3%. Cefoxitin BMD led to 4.9% VMEs and 1.6% MEs. Cefoxitin DD performed best when interpreted with the CLSI SOSA breakpoint, with 1.0% VMEs and 2.9% MEs. This study led CLSI to adjust the oxacillin MIC breakpoints for SOSA. Laboratories should be aware that no individual phenotypic test correlates well across all species of SOSA with mecA PCR results. Molecular testing for mecA or evaluation for PBP2a is the preferred approach.


Assuntos
Infecções Estafilocócicas , Staphylococcus capitis , Antibacterianos/farmacologia , Proteínas de Bactérias/genética , Cefoxitina/farmacologia , Humanos , Resistência a Meticilina , Testes de Sensibilidade Microbiana , Oxacilina/farmacologia , Proteínas de Ligação às Penicilinas , Staphylococcus , Staphylococcus haemolyticus , Staphylococcus hominis
2.
J Clin Microbiol ; 56(3)2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29212704

RESUMO

The performance characteristics of the ceftolozane-tazobactam (C-T) Etest (bioMérieux, Marcy l'Etoile, France), MIC test strips (MTS; Liofilchem, Italy), and disk diffusion (Hardy, Santa Ana, CA) were evaluated for a collection of 308 beta-lactam-resistant isolates of Pseudomonas aeruginosa recovered from three institutions in Los Angeles, CA. Reference testing was performed by the reference broth microdilution (rBMD) method. MIC and disk results were interpreted using Clinical and Laboratory Standards Institute breakpoints. Overall, 72.5% of the isolates were susceptible to C-T by rBMD. Etest and disk diffusion demonstrated acceptable performance, whereas MTS yielded a greater than acceptable percentage of minor errors. Categorical agreement was 96.8% for Etest, 87.0% for MTS, and 92.9% for disk diffusion. No very major errors were observed by any test, and no major errors (ME) were observed by Etest or disk diffusion. Two ME (0.9% of susceptible isolates) were observed by MTS. The incidence of minor errors was 3.2%, 12.3%, and 7.1% for Etest, MTS, and disk diffusion, respectively. Essential agreement (EA) for Etest was excellent, at 97.7%, whereas the MICs obtained by MTS tended to be 1 to 2 dilutions higher than those obtained by rBMD, with an EA of 87.0%.


Assuntos
Antibacterianos/farmacologia , Técnicas Bacteriológicas/normas , Cefalosporinas/farmacologia , Testes de Sensibilidade Microbiana/normas , Pseudomonas aeruginosa/efeitos dos fármacos , Tazobactam/farmacologia , Resistência beta-Lactâmica/efeitos dos fármacos , Humanos , Técnicas de Diluição do Indicador/normas , Testes de Sensibilidade Microbiana/instrumentação , Pseudomonas aeruginosa/isolamento & purificação
3.
Diagn Microbiol Infect Dis ; 98(4): 115171, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32927411

RESUMO

The correlation of ceftriaxone nonsusceptibility and ESBL production was evaluated in 40 characterized isolates. Performance of ceftriaxone susceptibility testing on the Accelerate Pheno was evaluated and compared with reference broth microdilution in triplicate. The CLSI ESBL confirmatory test was also evaluated. Ceftriaxone categorical agreement of the Accelerate Pheno was 97.5% with 1 minor error. The ESBL confirmatory disk test resulted in 4 false-negatives and 1 false positive. The Accelerate Pheno provides an expedited and accurate method of ceftriaxone susceptibility testing allowing for optimization of antimicrobial regimens sooner. These data indicate that ESBL production has a high likelihood of ceftriaxone non-susceptibility.


Assuntos
Antibacterianos/farmacologia , Bactérias/efeitos dos fármacos , Ceftriaxona/farmacologia , Testes de Sensibilidade Microbiana/métodos , beta-Lactamases/metabolismo , Bactérias/enzimologia , Bactérias/isolamento & purificação , Infecções Bacterianas/microbiologia , Farmacorresistência Bacteriana/efeitos dos fármacos , Farmacorresistência Bacteriana/genética , Genoma Bacteriano/genética , Genótipo , Humanos , Testes de Sensibilidade Microbiana/normas , beta-Lactamases/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA