Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Catheter Cardiovasc Interv ; 98(2): 371-379, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33876881

RESUMO

OBJECTIVES: To evaluate the safety and performance of the Hydra transcatheter aortic valve (THV) in the treatment of symptomatic severe aortic stenosis in patients at high or extreme surgical risk. BACKGROUND: The Hydra THV (Vascular Innovations Co. Ltd., Nonthaburi, Thailand) is a novel flexible repositionable self-expanding system with supra-annular bovine pericardial leaflets, available in three sizes, covering aortic annuli between 17 and 27 mm. METHODS: The GENESIS trial was a prospective, multi-center, single-arm, 6 month follow-up study conducted in India. The primary performance endpoint was device success defined as per VARC-II criteria at 30 days. The primary safety endpoint was all-cause mortality at 30 days. All endpoints were adjudicated by an independent clinical events committee. RESULTS: Forty high-risk patients (74.5 ± 6.7 years, 60% men; STS Score:5.6 ± 4.2%) were enrolled in 11 centres. Device success was achieved in 92.5%. The effective orifice area improved from 0.7 ± 0.2 to 2.3 ± 0.6 cm2 at 30 days and to 2.2 ± 0.7 cm2 at 6 months (p < .0001). Mean aortic valve gradient decreased from 53.5 ± 18.1 to 8.9 ± 4.9 mmHg at 30 days and to 7.6 ± 2.7 mmHg at 6 months (p < .0001). The rate of new permanent pacemaker implantation was 7.5% at 30 days, and no patient had more than mild paravalvular leak at 6 months. The 30 days and 6 month all-cause mortality was 10.0 and 17.5%, cardiovascular mortality 7.5 and 7.5%, device-related mortality 5.0 and 5.0%, respectively. No patients had stroke up to 6 months. CONCLUSIONS: The GENESIS trial demonstrated high efficacy of the self-expanding Hydra THV. The cardiovascular mortality rate of 7.5% may partly be explained by the inclusion of some centres with no or limited previous experience in transcatheter aortic valve implantation.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Hydra , Substituição da Valva Aórtica Transcateter , Animais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Bovinos , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Tailândia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
EuroIntervention ; 16(5): 421-429, 2020 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-31566572

RESUMO

AIMS: The aim of this study was to demonstrate the safety and efficacy of the next-generation balloon-expandable Myval transcatheter heart valve (THV) in an intermediate- or high-risk patient population with severe symptomatic native aortic stenosis. METHODS AND RESULTS: MyVal-1 was a first-in-human, prospective, multicentre, single-arm, open-label study. Between June 2017 and February 2018, a total of 30 patients were enrolled at 14 sites across India. Mean age was 75.5±6.7 years; 43.3% had coronary artery disease. The mean Society of Thoracic Surgeons score was 6.4±1.8% and 100% of the patients were in New York Heart Association (NYHA) functional Class II/III/IV pre-procedure. The six-minute walk test and Kansas City Cardiomyopathy Questionnaire (KCCQ) scores were recorded. After successful implantation of the Myval THV, 96.6% and 100% were in NYHA functional Class I/II at 30-day and 12-month follow-up, respectively. Outcomes of the six-minute walk test (148.0±87.4 vs 336.0±202.9 m) and KCCQ score (36.6±11.0 vs 65.9±11.4) improved from baseline to 12-month follow-up. The effective orifice area (0.6±0.2 vs 1.8±0.3 cm2, p<0.0001), mean aortic valve gradient (47.4±8.8 vs 12.0±3.3 mmHg, p<0.0001), peak aortic valve gradient (71.7±13.0 vs 20.3±5.9 mmHg, p<0.0001) and transaortic velocity (4.5±0.4 vs 2.2±0.4 m/s, p<0.0001) improved substantially from baseline to 12 months post procedure. Four all-cause mortality cases were reported up to 12 months. Moreover, there was no other moderate/severe paravalvular leak, aortic regurgitation or need for new permanent pacemaker (PPM) up to 12-month follow-up. CONCLUSIONS: The MyVal-1 study demonstrated the primary safety and efficacy of the Myval THV with no new PPM requirement up to 12-month follow-up. However, future trials with a larger number of patients and long-term follow-up are warranted to establish the safety and efficacy of the device.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Humanos , Índia , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento
3.
EuroIntervention ; 15(7): 607-614, 2019 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-31147308

RESUMO

AIMS: Although the proof of concept of the bioresorbable vascular scaffold (BRS) is well documented, device-related adverse outcomes with first-generation BRS indicate longer-term surveillance. The current study provides insights into the safety and performance of the MeRes100, a novel second-generation sirolimus-eluting BRS, beyond one-year up to three-year follow-up (FU). METHODS AND RESULTS: A total of 108 enrolled patients with de novo coronary artery lesions who underwent implantation of MeRes100 as part of the first-in-human MeRes-1 trial were followed up clinically beyond one year at two and three years and with multiple modality imaging at six months and two years. At three-year FU, the cumulative major adverse cardiac events rate was 1.87%, in the form of two ischaemia-driven target lesion revascularisations. No scaffold thrombosis was reported. Between six months and two years at quantitative coronary angiography, in-segment late lumen loss (LLL) (0.15±0.22 mm vs. 0.23±0.32 mm; p=0.18) and in-scaffold LLL (0.13±0.22 mm vs. 0.24±0.34 mm; p=0.10) changed insignificantly. IVUS subset analysis revealed a non-significant reduction in mean lumen area (6.17±1.28 mm2 vs. 5.47±1.50 mm2; p=0.21) and minimum lumen area (5.14±1.19 mm2 vs. 4.05±1.42 mm2; p=0.10) at two years compared to post-procedural measurements. OCT subset analysis demonstrated 99.24±2.27% neointimal strut coverage. CONCLUSIONS: The extended outcomes of the MeRes-1 trial demonstrated sustained efficacy and safety of the MeRes100 BRS with maintained lumen patency up to two years by multimodality imaging and no very late scaffold thrombosis up to three-year clinical FU.The MeRes-1 trial is registered at the Clinical Trials Registry-India. CTRI Number: CTRI/2015/04/005706.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/efeitos dos fármacos , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Everolimo/efeitos adversos , Seguimentos , Humanos , Índia , Intervenção Coronária Percutânea/efeitos adversos , Sirolimo/efeitos adversos , Resultado do Tratamento
4.
Cardiol Res ; 9(6): 364-369, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30627287

RESUMO

BACKGROUND: MeRes100™ (Meril Life Sciences Pvt. Ltd., Vapi, India) is a novel sirolimus-eluting bioresorbable vascular scaffold (BRS). The purpose of this sub-study of MeRes-1 trial is to evaluate the systemic release of sirolimus from MeRes100 BRS implanted for the treatment of de novo native coronary artery lesions. METHODS: The MeRes-1 is a prospective, multicenter, first-in-human trial of sirolimus-eluting MeRes100 BRS. The pharmacokinetic sub-study was conducted at two Indian sites in 10 patients who were implanted with the MeRes100 BRS loaded with sirolimus at a dose of 1.25 µg/mm2. Venous blood samples were collected at pre-dose and 12-time points after implantation of the scaffold. Sirolimus concentration was successively analyzed using ultra-performance liquid chromatography-electrospray ionization tandem mass spectrometry method. RESULTS: A total of 12 scaffolds were implanted in 10 patients. Non-compartmental analysis demonstrated time to reach peak concentration of sirolimus between 0.5 h to 3 h after scaffold implantation. The peak concentration (Cmax) was deduced to be 7.47 ± 2.61 ng/mL, AUC was 436.45 ± 171.24 h·ng/mL, and the t½ was observed at 98.59 ± 33.58 h. The clearance was 0.66 ± 0.16 L/h and lower limit of quantification was detectable at 14.1 days. CONCLUSIONS: The MeRes-1 pharmacokinetic sub-study confirmed that MeRes100 BRS is safe and tolerable at limited systemic exposure of sirolimus.

5.
EuroIntervention ; 13(4): 415-423, 2017 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-28504218

RESUMO

AIMS: The MeRes-1 trial sought to study the safety and effectiveness of a novel sirolimus-eluting bioresorbable vascular scaffold (MeRes100 BRS) in treating de novo native coronary artery lesions by clinical evaluation and using multiple imaging modalities. METHODS AND RESULTS: The MeRes-1 first-in-human trial was a single-arm, prospective, multicentre study, which enrolled 108 patients with de novo coronary artery lesions (116 scaffolds were deployed to treat 116 lesions in 108 patients). At six months, quantitative coronary angiography revealed in-scaffold late lumen loss of 0.15±0.23 mm with 0% binary restenosis. Optical coherence tomography demonstrated minimum scaffold area (6.86±1.73 mm2) and percentage neointimal strut coverage (99.30%). Quantitative intravascular ultrasound analysis confirmed a 0.14±0.16 mm2 neointimal hyperplasia area. At one year, major adverse cardiac events, a composite of cardiac death, any myocardial infarction and ischaemia-driven target lesion revascularisation, occurred in only one patient (0.93%) and there was no scaffold thrombosis reported. At one year, computed tomography angiography demonstrated that all scaffolds were patent and in-scaffold mean percentage area stenosis was 11.33±26.57%. CONCLUSIONS: The MeRes-1 trial demonstrated the safety and effectiveness of MeRes100 BRS. The favourable clinical outcomes and effective vascular responses have provided the basis for further studies in a larger patient population. The MeRes-1 trial is registered at the Clinical Trials Registry-India.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/uso terapêutico , Infarto do Miocárdio/tratamento farmacológico , Poliésteres/uso terapêutico , Sirolimo/uso terapêutico , Idoso , Vasos Coronários/diagnóstico por imagem , Everolimo/uso terapêutico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA