Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Proteomics ; 20(21-22): e1900353, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32418354

RESUMO

Multi-run alignment is widely used in proteomics to establish analyte correspondence across runs. Generally alignment algorithms return a cumulative score, which may not be easily interpretable for each peptide. Here a novel and interactive tool for cross-run chromatogram alignment visualization (DrawAlignR) of data-independent acquisition (DIA) data is presented. Furthermore, a novel C++ based implementation of raw chromatogram alignment which is 35 times faster than the previously published algorithm is developed. This not only enables users to plot alignment interactively by DrawAlignR, but also allows other software platforms to use the algorithm. DrawAlignR is an open-source web application using R Shiny that can be hosted using the source-code available at https://github.com/Roestlab/DrawAlignR.


Assuntos
Algoritmos , Proteômica , Software , Peptídeos
2.
Cureus ; 16(4): e59407, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38826596

RESUMO

Atrial fibrillation (AF) is the most commonly encountered cardiac arrhythmia globally. AF is associated with different consequences, such as peripheral vascular embolism, stroke, dementia, heart failure, and death. Catheter ablation (CA) has become a reliable therapeutic option for symptomatic AF. Utilizing mapping systems in conducting cryoablation is supposed to improve pulmonary vein isolation (PVI) durability and overall treatment success rate. We performed a review of relevant articles. We formulated a search strategy as follows: (atrial fibrillation AND ("cryoballoon ablation" OR cryoablation) AND (KODEX-EPD AND KODEX OR mapping). Data were collected from Web of Science, PubMed, Cochrane Library, and SCOPUS databases. We assessed the efficacy, procedural characteristics, and safety of cryoablation using the KODEX-EPD mapping system versus conventional cryoablation. We demonstrated the superiority of cryoablation guided by the KODEX-EPD system as it was associated with a significantly lower recurrence rate after the procedure (RR = 0.61, P = 0.03). Furthermore, it allowed a significant reduction in the volume of contrast medium used during the procedure (MD = -20.46, P = 0.04) when compared to the conventional cryoablation. We found no significant difference between both procedures in terms of successful cryoballoon-based PVI (P = 1.00), procedural duration (P = 0.95), procedural complications (P = 0.607), fluoroscopic time (P = 0.36), and fluoroscopic dose (P = 0.16). The use of the novel KODEX-EPD mapping system in the cryoablation procedure was associated with a significant reduction of the volume of contrast medium use and the recurrence rate compared with the conventional cryoablation while preserving similar efficacy, safety profile, and procedure time.

3.
Cureus ; 16(4): e58106, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38738122

RESUMO

Electrocautery is a commonly used technique in surgical procedures, generating smoke that poses health risks to surgical staff. This study investigates the comparative efficacy of normal surgical masks versus N95 masks in mitigating the harmful effects of electrocautery smoke. Through a systematic review of literature spanning two decades, we explore the causes and effects of electrocautery smoke exposure, including potential long-term inhalation effects. Our findings highlight significant disparities in the protection offered by different masks and underscore the importance of adequate respiratory protection in surgical settings. In addition, we examine the factors influencing the generation and composition of electrocautery smoke, such as the power settings used, the type of tissue being cauterized, and the duration of the procedure. Furthermore, we discuss the potential health risks associated with long-term exposure to electrocautery smoke, including the possibility of respiratory conditions, cardiovascular effects, and carcinogenicity. Our analysis also addresses the importance of implementing appropriate smoke evacuation systems and optimizing operating room ventilation to minimize the concentration of smoke particles in the surgical environment. Overall, this comprehensive analysis provides valuable insights into the impact of electrocautery smoke in surgical settings and the varying levels of protection offered by different masks.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA