RESUMO
In this paper, the first real-time implementation and perceptual evaluation of a singular value decomposition (SVD)-based optimal filtering technique for noise reduction in a dual microphone behind-the-ear (BTE) hearing aid is presented. This evaluation was carried out for a speech weighted noise and multitalker babble, for single and multiple jammer sound source scenarios. Two basic microphone configurations in the hearing aid were used. The SVD-based optimal filtering technique was compared against an adaptive beamformer, which is known to give significant improvements in speech intelligibility in noisy environment. The optimal filtering technique works without assumptions about a speaker position, unlike the two-stage adaptive beamformer. However this strategy needs a robust voice activity detector (VAD). A method to improve the performance of the VAD was presented and evaluated physically. By connecting the VAD to the output of the noise reduction algorithms, a good discrimination between the speech-and-noise periods and the noise-only periods of the signals was obtained. The perceptual experiments demonstrated that the SVD-based optimal filtering technique could perform as well as the adaptive beamformer in a single noise source scenario, i.e., the ideal scenario for the latter technique, and could outperform the adaptive beamformer in multiple noise source scenarios.
Assuntos
Inteligência Artificial , Percepção Auditiva/fisiologia , Auxiliares de Audição , Ruído/prevenção & controle , Reconhecimento Automatizado de Padrão/métodos , Terapia Assistida por Computador/instrumentação , Terapia Assistida por Computador/métodos , Transdutores , Adulto , Sistemas Computacionais , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Espectrografia do Som/instrumentação , Espectrografia do Som/métodosRESUMO
An adaptive beamformer for behind-the-ear dual-microphone hearing aids has been optimized for speech intelligibility enhancement in the presence of disturbing sounds or noise. The noise reduction approach is based on the scheme presented by Vanden Berghe and Wouters (1998). A real-time implementation of the signal processing is realized in Audallion, a wearable, small digital signal processing (DSP) platform. After physical evaluation, speech-in-noise intelligibility tests have been carried out on three normally-hearing and two hearing-impaired subjects. A significant speech reception threshold improvement of 11.3 dB was obtained in a moderately reverberant environment for one jammer sound source (steady speech-weighted noise or multi-talker babble) in a direction of 90 degrees relative to the direction of the speech.
Assuntos
Auxiliares de Audição , Ruído/prevenção & controle , Inteligibilidade da Fala , Limiar Auditivo , Perda Auditiva Neurossensorial/reabilitação , Humanos , Localização de Som , Teste do Limiar de Recepção da Fala , TransdutoresRESUMO
OBJECTIVE: The performance of an adaptive beam-former in a 2-microphone, behind-the-ear hearing aid for speech understanding in noisy environments was evaluated. Physical and perceptual evaluations were carried out. This was the first large-scale test of a wearable real-time implementation of this algorithm. The main perceptual research questions of this study were related to the influence on the noise reduction performance of (1) the spectro-temporal character of the jammer sound, (2) the jammer sound scene, (3) hearing impairment, and (4) the basic microphone configuration in the hearing aid. Four different speech materials were used for the perceptual evaluations. All tests were carried out in an acoustical environment comparable to living room reverberation. DESIGN: The adaptive beamformer was implemented in Audallion, a small, body-worn processor, linked to a Danasound 2-microphone behind-the-ear aid. The strategy was evaluated physically in different acoustical environments. Using speech reception threshold (SRT) measurements, the processing was evaluated perceptually and the different research questions addressed with three groups of subjects. Groups I, II, and III consisted of 10 normal-hearing, 5 hearing-impaired, and 7 normal-hearing persons, respectively. The tests were carried out in three spectro-temporally different jammer sounds (unmodulated and modulated speech weighted noise, multitalker babble) and in three different noise scenarios (single noise source at 90 degrees, noise sources at 90 degrees and 270 degrees relative to speaker position, diffuse noise scene). Two microphone configurations were compared: a device equipped with two omnidirectional microphones and a device equipped with one hardware directional and one omnidirectional microphone. In each of these conditions, the adaptive beamformer and the directional and omnidirectional microphone configurations were tested. RESULTS: The improvement in signal-to-noise ratio from the use of the adaptive beamformer did not depend on the spectro-temporal character of the jammer sounds and the speech materials used, although the absolute levels of the SRTs varied appreciably for different speech-noise combinations. The performance of the adaptive noise reduction depended on the jammer sound scene. CONCLUSIONS: No difference in signal-to-noise ratio improvement was observed between hearing-impaired and normal-hearing listeners, although individual SRT levels may differ. On average, an SRT improvement of 7.7 and 3.9 dB for a single noise source at 90 degrees and 5.9 and 3.4 dB for two noise sources at 90 degrees and 270 degrees was obtained for both normal-hearing and hearing-impaired listeners, using the adaptive beamformer and the directional microphone, respectively, relative to the omnidirectional microphone signal. In diffuse noise, only small improvements were obtained.
Assuntos
Auxiliares de Audição , Perda Auditiva/terapia , Ruído/efeitos adversos , Percepção da Fala/fisiologia , Adulto , Estudos de Casos e Controles , Desenho de Equipamento , Humanos , Pessoa de Meia-Idade , Resultado do TratamentoRESUMO
OBJECTIVE: To evaluate the improvement in speech intelligibility in noise obtained with an assistive real-time fixed endfire array of bidirectional microphones in comparison with an omnidirectional hearing aid microphone in a realistic environment. DESIGN: The microphone array was evaluated physically in anechoic and reverberant conditions. Perceptual tests of speech intelligibility in noise were carried out in a reverberant room, with two types of noise and six different noise scenarios with single and multiple noise sources. Ten normal-hearing subjects and 10 hearing aid users participated. The speech reception threshold for sentences was measured in each test setting for the omnidirectional microphone of the hearing aid and for the hearing aid in combination with the array with one and three active microphones. In addition, the extra improvement of five active array microphones, relative to three, was determined in another group of 10 normal-hearing listeners. RESULTS: Improvements in speech intelligibility in noise obtained with the array relative to an omnidirectional microphone depend on noise scenario and subject group. Improvements up to 12 dB for normal-hearing and 9 dB for hearing-impaired listeners were obtained with three active array microphones relative to an omnidirectional microphone for one noise source at 90 degrees . For three uncorrelated noise sources at 90 degrees, 180 degrees, and 270 degrees, improvements of approximately 9 dB and 6 dB were obtained for normal-hearing and hearing-impaired listeners, respectively. Even with a single noise source at 45 degrees, benefits of 4 dB were achieved in both subject groups. Five active microphones in the array can provide an additional improvement at 45 degrees of approximately 1 dB, relative to the three-microphone configuration for normal-hearing listeners. CONCLUSIONS: These improvements in signal-to-noise ratio can be of great benefit for hearing aid users, who have difficulties with speech understanding in noisy environments.