Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Am J Dent ; 31(6): 320-328, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30658380

RESUMO

PURPOSE: (1) To conduct a comprehensive review of the literature on factors influencing the radiant exposure of resin-based composite (RBC) restorations and (2) To fully understand the appropriate way of using the light curing units (LCUs) to perform restorations with optimal mechanical/physical properties. METHODS: A PubMed search identified recent publications in English that addressed the factors affecting the longevity of the RBC restorations and the optimal usage of LCUs. RESULTS: RBCs require light-induced polymerization of methacrylate monomers present in its composition to reach acceptable mechanical and physical properties. Complete polymerization of the RBC is never reached, and the maximum degree of conversion (DC) varies from 40 to 80%. The amount of radiant exposure (Joules/cm²) required for the commencement of polymerization becomes a core driver for the quality of the RBCs. Insufficient radiant exposure may lead to low strength behavior and susceptibility to degradation, thereby shortening the lifespan of restorations inside the mouth. This suggests that there are factors affecting the radiant exposure during clinical procedures; these factors can be categorized as material-related, LCU-related and operator-related factors. CLINICAL SIGNIFICANCE: Proper light-curing techniques are critical for delivering an adequate amount of radiant exposure to RBCs. Adequate light curing decreases the number of underexposed RBC restorations, improves their mechanical and physical properties and accordingly, increases their clinical longevity.


Assuntos
Lâmpadas de Polimerização Dentária , Cura Luminosa de Adesivos Dentários , Resinas Compostas , Materiais Dentários , Teste de Materiais , Polimerização
2.
Int J Dent ; 2021: 5578274, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34234828

RESUMO

OBJECTIVES: Light curing is crucial when applying composite resin restorations. Complete polymerization of the resin depends on delivering adequate light energy to it. Dental clinicians may be unaware of the importance of proper light-curing techniques. This study aimed at evaluating and comparing the level of knowledge of general practitioners (GPs) and specialists (SPs) regarding light-curing units. MATERIALS AND METHODS: An electronic survey was conducted online among GPs and SPs of various specialties, working in the governmental sector in Riyadh, Saudi Arabia. Collected data were analyzed for statistical significance. RESULTS: 310 dentists were included in the study. Nearly half of the GPs (45.9%) and more than half of SPs (56.8%) use light-emitting diode (LED) type light-curing units (LCUs). 36.9% of GPs and 29.6% of SPs were unsure about the type of LCUs they use in their dental clinics. 10.8% of GPs and 8.5% of SPs knew the proper term of the power output of LCU. 52.2% of the GPs and 55.7% of SPs were wrong about advancements in technology of LED LCUs. Regarding the use of radiometer, 48.2% of SPs and 35.1% of GPs had responded wrongly, and 37.7% of SPs and 52.3% of GPs were not familiar with the device, showing a statistical significance (p=0.040). There was no statistical significance observed in the responses pertaining to their years of experience, expected for two questions. CONCLUSION: Both GPs and SPs displayed inadequate knowledge regarding the use of LCUs. Further educational programs are recommended to spread awareness about the handling of LCUs among dental clinicians.

3.
Restor Dent Endod ; 46(4): e51, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34909415

RESUMO

OBJECTIVES: This study aimed to evaluate the effect of improper positioning single-peak and multi-peak lights on color change, microhardness of bottom and top, and surface topography of bulk fill and incremental composites after artificial aging for 1 year. MATERIALS AND METHODS: Bulk fill and incremental composites were cured using multi-peak and single-peak light-emitting diode (LED) following 4 clinical conditions: (1) optimal condition (no angulation or tip displacement), (2) tip-displacement (2 mm), (3) slight tip angulation (α = 20°) and (4) moderate tip angulation (α = 35°). After 1-year of water aging, the specimens were analyzed for color changes (ΔE), Vickers hardness, surface topography (Ra, Rt, and Rv), and scanning electron microscopy. RESULTS: For samples cured by single-peak LED, the improper positioning significantly increases the color change compared to the optimal position regardless of the type of composite (p < 0.001). For multi-peak LED, the type of resin composite and the curing condition displayed a significant effect on ΔE (p < 0.001). For both LEDs, the Vickers hardness and bottom/top ratio of Vickers hardness were affected by the type of composite and the curing condition (p < 0.01). CONCLUSIONS: The bulk fill composite presented greater resistance to wear, higher color stability, and better microhardness than the incremental composite when subjected to improper curing. The multi-peak LED improves curing under improper conditions compared to single-peak LED. Prevention of errors when curing composites requires the attention of all personnel involved in the patient's care once the clinical relevance of the appropriate polymerization reflects on reliable long-term outcomes.

4.
Dent J (Basel) ; 9(8)2021 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-34435995

RESUMO

How dentists cure a resin-based material has deleterious effects on the material's properties and its interaction with surrounding dental tissues. Biofilm accumulation has been implicated in the pathogenesis of carious lesions around dental restorations, with its composition manifesting expressed dysbiosis in patients suffering from dental caries. To evaluate the influence of varying radiant exposure on the degree of conversion (DC%), Streptococcus mutans biofilm growth, and surface roughness of bulk-fill composites under different light-curing conditions. Two light-curing units (LCU) at 600 and 1000 mW/cm2 were used to simulate curing conditions with different angulations (∢20° and ∢35°) or 2 mm-distance displacements of the LCU tip. The radiant exposure (RE) was assessed, and the composites were analyzed for DC%. Biofilm formation was induced over the bulk-fill composites and analyzed via colony-forming units counting and scanning electron microscopy (SEM). The surface roughness was analyzed via a profilometer and SEM after biofilm formation. Curing conditions with different angulation or displacement decreased RE compared to the "optimal condition". The moderately (∢35°) angulated LCU tip and low (600 mW/cm2) radiant emittance significantly reduced the DC% (p < 0.05). The difference in DC% between the top and bottom of the composites ranged from 8 to 11% for 600 mW/cm2 and 10 to 20% for 1000 mW/cm2. Greater S. mutans biofilm and surface changes were found in composites with non-optimal RE delivery (e.g., tip displacement and angulation) (p < 0.05). Inadequate polymerization of bulk-fill composites was associated with more biofilm accumulation and surface topography changes. Overall, non-optimally performed curing procedures reduced the amount of delivered RE, which led to low DC%, more biofilm formation, and higher surface roughness. The improper light-curing of bulk-fill composites compromises their physicochemical and biological properties, which could lead to inferior clinical performance and reduced restorative treatments' longevity.

5.
J Dent ; 88: 103110, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31022421

RESUMO

OBJECTIVES: Insufficient radiant exposure (J/cm2) may provide an early trigger in a cascade of detrimental responses on incrementally-place composite, especially the bottom layer. This study aimed to assess the influence of poor radiant exposure, the degree of conversion (%DC), water sorption/ solubility and S. mutans biofilm formation on conventional, incrementally placed composites and to establish a relationship between these factors. METHODS: Two light units operating at 600 and 1000 mW/cm2 and four most common operator-dependent curing conditions had the radiant exposure (RE) recorded. All the specimens were subjected to S. mutans biofilm model for 14 days. The %DC, biofilm formation expressed by colony-forming units (CFU), water sorption/ solubility and surface roughness/ SEM were assessed. Data were submitted to two-way ANOVA and Tukey post-hoc test (α = 0.05). Pearson correlation was also determined. RESULTS: The influence of RE on S. mutans CFU values and DC are dependent on the curing conditions and irradiance (p < 0.05). A negative relationship was observed between RE and biofilm formation. The operator-dependent curing conditions have shown RE reduction varying from 49.4% to 73.5% in relation to control. The difference in DC between top/bottom of cylinder varied from 13% to 21% for 1000 mW/cm2and from 29% to 53% for LCU600. The roughness, solubility and salivary sorption were greater for low RE. CONCLUSION: Poor, deficient curing procedures provide an early trigger in a negative pathway of events for incrementally-place dental composite including a biological response by increased biofilm formation by S. mutans, a relevant factor for secondary caries development. SIGNIFICANCE: The susceptibility to variation in the outcomes was RE -dependent. The optimization of the curing procedures ensures the maximum performance in the chain of events involved in the light curing process of resin-based materials and potentially reduce the risk factors of secondary caries development.


Assuntos
Biofilmes/efeitos da radiação , Resinas Compostas/efeitos da radiação , Lâmpadas de Polimerização Dentária , Cura Luminosa de Adesivos Dentários/métodos , Aderência Bacteriana , Resinas Compostas/química , Materiais Dentários , Humanos , Teste de Materiais , Solubilidade , Streptococcus mutans , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA