Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
BMC Neurol ; 13: 61, 2013 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-23767957

RESUMO

BACKGROUND: Limited information has been published regarding standard quality assurance (QA) procedures for stroke registries. We share our experience regarding the establishment of enhanced QA procedures for the University of Texas Houston Stroke Registry (UTHSR) and evaluate whether these QA procedures have improved data quality in UTHSR. METHODS: All 5093 patient records that were abstracted and entered in UTHSR, between January 1, 2008 and December 31, 2011, were considered in this study. We conducted reliability and validity studies. For reliability and validity of data captured by abstractors, a random subset of 30 records was used for re-abstraction of select key variables by two abstractors. These 30 records were re-abstracted by a team of experts that included a vascular neurologist clinician as the "gold standard". We assessed inter-rater reliability (IRR) between the two abstractors as well as validity of each abstractor with the "gold standard". Depending on the scale of variables, IRR was assessed with Kappa or intra-class correlations (ICC) using a 2-way, random effects ANOVA. For assessment of validity of data in UTHSR we re-abstracted another set of 85 patient records for which all discrepant entries were adjudicated by a vascular neurology fellow clinician and added to the set of our "gold standard". We assessed level of agreement between the registry data and the "gold standard" as well as sensitivity and specificity. We used logistic regression to compare error rates for different years to assess whether a significant improvement in data quality has been achieved during 2008-2011. RESULTS: The error rate dropped significantly, from 4.8% in 2008 to 2.2% in 2011 (P < 0.001). The two abstractors had an excellent IRR (Kappa or ICC ≥ 0.75) on almost all key variables checked. Agreement between data in UTHSR and the "gold standard" was excellent for almost all categorical and continuous variables. CONCLUSIONS: Establishment of a rigorous data quality assurance for our UTHSR has helped to improve the validity of data. We observed an excellent IRR between the two abstractors. We recommend training of chart abstractors and systematic assessment of IRR between abstractors and validity of the abstracted data in stroke registries.


Assuntos
Prontuários Médicos , Controle de Qualidade , Sistema de Registros , Projetos de Pesquisa , Acidente Vascular Cerebral/epidemiologia , Universidades , Adulto , Idoso , Análise de Variância , Antitrombinas/uso terapêutico , Processamento Eletrônico de Dados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Acidente Vascular Cerebral/tratamento farmacológico , Texas/epidemiologia
2.
BMJ Open ; 9(9): e026496, 2019 09 04.
Artigo em Inglês | MEDLINE | ID: mdl-31488463

RESUMO

INTRODUCTION: The Lone Star Stroke Consortium Telestroke Registry (LeSteR) currently consisting of 3 academic hub centres and 27 partner spokes is a statewide initiative organised by leading academic health centres in the State of Texas to understand practice patterns of acute stroke management via telestroke (TS) in Texas, a state with one of the largest rural populations in the USA. METHODS AND ANALYSIS: All patients who had presumed stroke for whom a TS consultation has been obtained in the network are entered into a web-based, Health Insurance Portability and Accountability Act-compliant database from September 2013 to present. Spokes were enrolled into LeSteR in a staggered approach in two data collection phases: a retrospective phase and a prospective phase. Basic clinical, demographic data and relevant time metrics are collected in the retrospective phase. Starting 1 September 2015, additional outcome data including 90-day modified Rankin score, readmission and 90-day disposition are obtained by a standard phone interview. From the registry initiation to 31 December 2017, there are 8089 patients who had suspected stroke in the registry. Over 60% of patients enrolled after 1 September 2015 have reported outcome data. Enrolment is still active for this registry. ETHICS AND DISSEMINATION: LeSteR is a statewide TS registry organised by academic health centres that will provide significant insight regarding the impact of TS in the State of Texas. Findings from LeSteR will provide data that can be analysed to improve the allocation of healthcare resources using TS to treat stroke in a state with one of the largest rural populations.


Assuntos
Isquemia Encefálica/terapia , Sistema de Registros , Consulta Remota/normas , Acidente Vascular Cerebral/terapia , Telemedicina/métodos , Terapia Trombolítica/normas , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/fisiopatologia , Fibrinolíticos/administração & dosagem , Humanos , Projetos de Pesquisa , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/fisiopatologia , Texas , Fatores de Tempo , Tempo para o Tratamento/normas , Ativador de Plasminogênio Tecidual/administração & dosagem , Resultado do Tratamento , Comunicação por Videoconferência/normas , Fluxo de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA