RESUMO
Despite evidence of improved diabetes outcomes with diabetes technology such as continuous glucose monitoring (CGM) systems, insulin pumps, and hybrid closed-loop (HCL) insulin delivery systems, these devices are underutilized in clinical practice for the management of insulin-requiring diabetes. This low uptake may be the result of health care providers' (HCPs') lack of confidence or time to prescribe and manage devices for people with diabetes. We administered a survey to HCPs in primary care, pediatric endocrinology, and adult endocrinology practices in the United States. Responding HCPs expressed a need for device-related insurance coverage tools and online data platforms with integration to electronic health record systems to improve diabetes technology uptake in these practice settings across the United States.
RESUMO
Background: Continuous glucose monitoring (CGM) improves neonatal outcomes in type 1 diabetes pregnancies; however, its effectiveness has not been assessed in a real-world setting in the United States. Objective: The Triple C Study aimed to examine the clinical effectiveness, assessed through maternal glucose control and gestational health outcomes, of CGM use compared with self-monitoring of blood glucose (SMBG) in pregnancies associated with type 1 diabetes in a real-world setting. Research Design and Methods: We retrospectively identified 160 type 1 diabetes pregnancies at the Barbara Davis Center for Diabetes managed with CGM therapy (n = 109) or SMBG (n = 51) over a 6.5-year period (2014-2020). Obstetric care was provided at multiple practices. CGM use was defined as ≥60% wear in the second and third trimesters of pregnancy. Data were obtained from the electronic medical record system, hospital records, and vital statistics departments (Colorado and Wyoming). We used Student's t-test for continuous variables and chi-square test for categorical variables to compare outcomes between groups. Results: The CGM group had more participants meeting trimester-specific hemoglobin A1C (HbA1c) goals throughout pregnancy and postpartum (P < 0.01 in each time period). The CGM group had fewer participants never meeting HbA1c goals in any trimester than the SMBG group (P < 0.001). There were no significant differences in neonatal outcomes between groups, other than for macrosomia (12.8% CGM vs. 29.4% SMBG, P = 0.01). Infants of CGM users required a neonatal intensive care unit admission less often (52.9% CGM vs. 68.3% SMBG, P = 0.0989). Conclusions: CGM use was associated with improved maternal glucose levels in a diverse real-world cohort.
Assuntos
Automonitorização da Glicemia , Glicemia , Diabetes Mellitus Tipo 1 , Gravidez em Diabéticas , Humanos , Feminino , Gravidez , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Estudos Retrospectivos , Gravidez em Diabéticas/sangue , Gravidez em Diabéticas/tratamento farmacológico , Adulto , Glicemia/análise , Hemoglobinas Glicadas/análise , Controle Glicêmico/estatística & dados numéricos , Recém-Nascido , Resultado da Gravidez , Hipoglicemiantes/uso terapêutico , Monitoramento Contínuo da GlicoseRESUMO
Objective: Examine gestational safety, glycemic and health outcomes, of a hybrid closed-loop (HCL) system without pregnancy-specific glucose targets. Research Design: This was a pilot feasibility investigator-initiated, two-site, single-blind, randomized controlled trial of sensor-augmented pump therapy (SAPT) versus HCL therapy in type 1 diabetes pregnancies. Participants were enrolled in the first trimester and randomized at 14-18 weeks of gestation and used SAPT or HCL until 4-6 weeks postpartum. We compared continuous glucose monitoring (CGM) metrics, severe hypoglycemia (SH), diabetic ketoacidosis (DKA), adverse skin reactions, and pregnancy outcomes between groups. Results: Baseline characteristics were similar between groups (n = 11 HCL and n = 12 SAPT). There was no SH or DKA episode after randomization. Time spent <54 mg/dL did not differ between groups. Time spent <63 mg/dL decreased in both groups, significantly in the HCL group (3.5% [1.3% standard error] second trimester and 2.8% [1.3%] third trimester vs. 7.9% [1.3%] run-in phase, P < 0.05 for both). Mean sensor glucose was lower with SAPT compared to HCL therapy in the third trimester (119 [4] mg/dL SAPT vs. 132 [4] mg/dL HCL, P < 0.05). Third trimester time-in-range (TIR; 63-140 mg/dL) increased with SAPT (68.2% [3.1%] vs. 64.3% [3.1%] run-in phase, P < 0.05). Gestational health outcomes did not differ between groups. The HCL group used assistive techniques, such as fake carbohydrate boluses and exiting HCL overnight. Conclusions: CGM within group differences were seen for time <63 mg/dL favoring HCL therapy and TIR favoring SAPT (third trimester vs. baseline). Safety and adverse pregnancy outcomes were similar between groups.