Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Pol J Radiol ; 82: 783-791, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29657645

RESUMO

Gastrointestinal tuberculosis (GI TB) is an important manifestation of abdominal tuberculosis (TB), an extra-pulmonary form of the disease. GI TB commonly affects the small bowel but is difficult to diagnose due to the challenge of evaluating the entire length of overlapping small bowel loops with traditional diagnostic methods like Barium meal follow through, abdominal computed tomography (CT), and endoscopy. New techniques of CT/MR enteroclysis/enterography are now available which specifically image the small bowel. MDCT enterography (MDCTE) is a non-invasive, simple to perform, modified abdominal CT imaging technique permitting reasonably accurate evaluation of the small bowel lumen, wall, perienteric tissues, and solid organs within the abdomen. As GI TB can cause morphological alterations in and around the small bowel, MDCTE seems to be an attractive modality for patients suspected of abdominal or GI TB. As scarce literature is available on MDCTE on tuberculosis, we present a pictorial review on MDCTE findings in patients with GI tuberculosis proved on FNAC and clinical and/or imaging follow-up.

2.
Indian J Radiol Imaging ; 32(4): 451-459, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36451960

RESUMO

Background Computed tomography perfusion (CTp), a useful technique in oncology, is not widely utilized due to the high radiation dose delivered from it. It involves scanning the region of interest every second for 50 seconds following intravenous contrast administration. Doubling sampling interval (SI) to 2 seconds will half the radiation dose, but may impact its effectiveness, which needs to be evaluated. Objectives To evaluate a dose reduction strategy in CTp by determining agreement between standard dose (SD) CTp (acquisition with SI 1 second) and low-dose CTp techniques with SI of 2 seconds (achieved either by reconstruction only or true low-dose acquisition). Materials and methods This cross-sectional study was conducted on histopathology-proven head and neck squamous cell carcinoma (HNSCC) patients who underwent CTp on 64 slice multidetector CT. A total of 56 patients had SD and 24 patients underwent true low dose (LD) acquisition. SD data were also reconstructed at SI 2 seconds to obtain a dataset simulating low dose (low-dose reconstruction [LDr]). Paired t -test was applied to compare CTp in SD and LDr groups and the Bland-Altman plot drawn to calculate 95% confidence limit of agreement. The Kolmogorov-Smirnov test compared CTp parameters for LDr and LD groups. Results There was no statistical difference in CTp parameters (except blood flow in malignant) in SD and LDr groups for both malignant and normal tissues. CTp of malignant tissue was not statistically different in LDr and LD groups but the radiation dose was half in the LD group. Conclusion Reduction of radiation dose to half achieved by doubling the SI does not affect the CTp parameters significantly. So LD acquisitions will increase the use of CTp in HNSCC.

3.
Indian J Radiol Imaging ; 30(3): 395-399, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33273779

RESUMO

Dorsal agenesis of the pancreas is a rare entity, with about 100 cases reported. It can be overlooked on ultrasound due to the non visualization of the body and tail of the pancreas. This is due to overlying gas in the stomach, which offers a poor acoustic window and obscures visualization. Renal agenesis and Mullerian duct anomalies are uncommon associations of dorsal agenesis of the pancreas because of the separate embryological origin of the pancreas and genitourinary organs. Here, we present a case of a 17-year-old patient who had dorsal agenesis of the pancreas, associated with unilateral renal agenesis, unicornuate uterus, and ectopic ovary. We describe the anomalies and discuss the radiological differential diagnosis and potential pitfalls. We provide a brief review of the literature with few radiological teaching points and possible genetic implications of the case.

4.
Indian J Radiol Imaging ; 29(4): 468-471, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31949355

RESUMO

Osseous metaplasia of inflammatory sinonasal polyp is an extremely rare entity. Correct preoperative diagnosis by noncontrast CT scan is needed to rule out other more common bony neoplasms in paranasal sinuses and for accurate surgical planning. Here, we present a case of 20-year-old patient with an antrochoanal polyp with osseous metaplasia. We describe the lesion and discuss the radiological differential diagnosis thereby providing a brief review of literature of the few published cases worldwide along with histopathological correlation.

5.
J Ultrasound ; 20(3): 253-259, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28900528

RESUMO

Acute swelling and discoloration of scrotum in new born can have many localized causes like testicular torsion, inguinal hernia, scrotal or testicular edema, hydrocele, or even remote causes like adrenal hemorrhage. We report a neonate of adrenal hemorrhage presenting clinically as acute scrotum misguiding the clinician to rule out a local scrotal pathology. As the local clinical examination is not reliable in a newborn, it definitely requires an imaging evaluation to establish the diagnosis. This case report emphasizes being aware of the clinical association of acute adrenal hemorrhage and an acute scrotum and the role of ultrasonography in the evaluation of the various differential diagnoses leading to an acute scrotum. An optimum sonographic examination helps in suspecting an abdominal pathology as a cause of acute scrotum and in establishing the specific diagnosis of adrenal hemorrhage to avoid an unnecessary surgical exploration.


Assuntos
Doenças das Glândulas Suprarrenais/diagnóstico por imagem , Hemorragia/diagnóstico por imagem , Ultrassonografia , Diagnóstico Diferencial , Evolução Fatal , Doenças dos Genitais Masculinos/diagnóstico por imagem , Humanos , Recém-Nascido , Masculino , Escroto/diagnóstico por imagem , Choque/mortalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA