Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 245
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Cardiovasc Diabetol ; 23(1): 52, 2024 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-38310281

RESUMO

BACKGROUND: The outcomes of percutaneous coronary intervention (PCI) in diabetic patients are still suboptimal, and it is unclear if diabetic patients might derive a benefit from the use of drug-coated balloons. AIMS: To evaluate the impact of diabetes mellitus on the outcomes of patients undergoing PCI with sirolimus-coated balloon (SCB) MagicTouch (Concept Medical, India). METHODS: We conducted a subgroup analysis of the prospective, multicenter, investigator-initiated EASTBOURNE registry, evaluating the performance of MagicTouch SCB in patients with and without diabetes. The study primary endpoint was target lesion revascularization (TLR) at 12-month follow-up. Secondary clinical endpoints were major adverse clinical events (MACE), death, myocardial infarction (MI), and BARC 2-5 bleedings. RESULTS: Among 2,083 enrolled patients, a total of 864 suffered from diabetes (41.5%). Patients with diabetes had a numerically higher occurrence of TLR (6.5% vs. 4.7% HR 1.38, 95%CI 0.91-2.08), all-cause death (3.8% vs. 2.6%, HR 1.81, 95%CI 0.95-3.46), and MACE (12.2% vs. 8.9%; HR 1.26 95%CI 0.92-1.74). The incidence of spontaneous MI was significantly higher among diabetic patients (3.4% vs. 1.5%, HR 2.15 95%CI 1.09-4.25); bleeding events did not significantly differ. The overall incidence of TLR was higher among in-stent restenosis (ISR) as compared to de-novo coronary lesions, irrespectively from diabetes status. CONCLUSIONS: In the EASTBOURNE DIABETES registry, diabetic patients treated with the MagicTouch SCB did not have a significant increase in TLR when compared to non-diabetic patients; moreover, diabetic status did not affect the study device performance in terms of TLR, in both de-novo lesions and ISR.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária , Diabetes Mellitus , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Sirolimo/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/etiologia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Diabetes Mellitus/induzido quimicamente , Sistema de Registros , Reestenose Coronária/epidemiologia , Reestenose Coronária/etiologia
2.
Catheter Cardiovasc Interv ; 103(1): 209-218, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37957842

RESUMO

BACKGROUND: Balloon post-dilation (BPD) is a widely adopted strategy to optimize acute results of TAVI, with a positive impact on both paravalvular leak and mean gradients. On the other hand, the inflation of the balloon inside prosthetic leaflets may damage them increasing the risk of structural valve deterioration (SVD). Furthermore, the impact of BPD on long-term clinical outcomes and valve hemodynamics is yet unknown. AIMS: To evaluate the impact of BPD on valve durability and long-term clinical outcomes in patients undergoing self-expanding transcatheter valve implantation (TAVI). METHODS: Echocardiographic and clinical data from the ClinicalService (a nation-based data repository and medical care project) were analyzed. Patients were divided into two groups, those who underwent BPD after TAVI and those who did not. Coprimary endpoints were all-cause death and SVD. Cumulative incidence functions for SVD were estimated. RESULTS: Among 1835 patients included in the study, 417 (22.7%) underwent BPD and 1418 (77.3%) did not undergo BPD. No statistically significant differences at 6-year follow-up were found between groups in terms of all-cause mortality (HR: 1.05, 95% CI: 0.9-1.22; p = 0.557) and SVD (2.1% vs. 1.4%, p = 0.381). In addition, BPD did not predispose to higher risk of cardiovascular death, myocardial infarction, valve thrombosis, and endocarditis at 6-year follow-up. CONCLUSIONS: BPD following TAVI with a self-expanding prosthesis does not seem to be associated with an increased risk of adverse clinical outcomes or SVD at 6-year follow-up.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Dilatação , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Desenho de Prótese
3.
Eur Heart J Suppl ; 26(Suppl 1): i53-i55, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38867876

RESUMO

Tricuspid regurgitation (TR) is common both in patients with left side valvular heart disease and in patients with permanent atrial fibrillation and is associated with increased mortality, morbidity, and an increased risk of hospitalization. Surgery for isolated tricuspid repair is a viable option but burdened by a high-operative risk and a post-operative course characterized by high morbidity. Recently, percutaneous interventional techniques have emerged as a viable option in selected high-risk patients who may clinically benefit from tricuspid valve repair. The purpose of this article is to provide an overview of the current state of transcatheter restorative treatment of TR by providing an overview of new devices in clinical development.

4.
Eur Heart J ; 44(15): 1331-1339, 2023 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-36883599

RESUMO

AIMS: Paravalvular regurgitation (PVR) after transcatheter aortic valve implantation (TAVI) is associated with increased morbidity and mortality. The effect of transcatheter interventions to treat PVR after the index TAVI was investigated. METHODS AND RESULTS: A registry of consecutive patients who underwent transcatheter intervention for ≥ moderate PVR after the index TAVI at 22 centers. The principal outcomes were residual aortic regurgitation (AR) and mortality at 1 year after PVR treatment. A total of 201 patients were identified: 87 (43%) underwent redo-TAVI, 79 (39%) plug closure, and 35 (18%) balloon valvuloplasty. Median TAVI-to-re-intervention time was 207 (35; 765) days. The failed valve was self-expanding in 129 (63.9%) patients. The most frequent devices utilized were a Sapien 3 valve for redo-TAVI (55, 64%), an AVP II as plug (33, 42%), and a True balloon for valvuloplasty (20, 56%). At 30 days, AR ≥ moderate persisted in 33 (17.4%) patients: 8 (9.9%) after redo-TAVI, 18 (25.9%) after plug, and 7 (21.9%) after valvuloplasty (P = 0.036). Overall mortality was 10 (5.0%) at 30 days and 29 (14.4%) at 1 year: 0, 8 (10.1%), and 2 (5.7%) at 30 days (P = 0.010) and 11 (12.6%), 14 (17.7%), and 4 (11.4%) at 1 year (P = 0.418), after redo-TAVI, plug, and valvuloplasty, respectively. Regardless of treatment strategy, patients in whom AR was reduced to ≤ mild had lower mortality at 1 year compared with those with AR persisting ≥ moderate [11 (8.0%) vs. 6 (21.4%); P = 0.007]. CONCLUSION: This study describes the efficacy of transcatheter treatments for PVR after TAVI. Patients in whom PVR was successfully reduced had better prognosis. The selection of patients and the optimal PVR treatment modality require further investigation.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Prognóstico , Resultado do Tratamento , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia
5.
Catheter Cardiovasc Interv ; 101(4): 798-805, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36841945

RESUMO

OBJECTIVES: The objective of this study is to investigate the use of cutting balloon (CB) inflated at high pressure compared with noncompliant balloon (NCB) for the treatment of calcified coronary lesions. BACKGROUND: No data are available regarding the safety and efficacy of CB inflated at high pressure in coronary artery calcifications. METHODS: Patients with calcified lesions (more than 100° of calcium demonstrated at baseline intravascular ultrasound) were randomized. Primary endpoint of the study was the final minimal stent area (MSA) and stent symmetry in the calcific segment. Secondary endpoints included rate of device failure and the 1-year rate of target lesion revascularization, target vessel revascularization, and major adverse cardiovascular events. RESULTS: From September 2019 to June 2021, a total of 100 patients were included and randomized; 13 patients were excluded for major protocol deviations. Lesions were complex (type B2/C n = 61 [71.2%]) with a mean arch of calcium of 266 ± 84°, a calcium length of 12 ± 6.6 mm. CB was inflated at comparable atmospheres when compared with NCB (18.3 ± 5 vs. 19 ± 4.5, p = 0.46). In the per-protocol population, the final MSA at the level of the calcium site was significantly higher in the CB group (8.1 ± 2 vs. 7.3 ± 2.1, p = 0.035) with a higher eccentricity index achieved in the CB group (0.84 ± 0.07 vs. 0.8 ± 0.08, p = 0.013). Three device failure occurred in the CB group. One-year follow-up outcomes were comparable. CONCLUSIONS: Treatment of calcified lesions with high-pressure CB has a good safety profile and is associated with a larger MSA and higher eccentricity of the stent at the level of the calcium site compared with NCB.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Humanos , Angiografia Coronária , Cálcio , Resultado do Tratamento , Doença da Artéria Coronariana/terapia , Stents
6.
Catheter Cardiovasc Interv ; 102(5): 931-943, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37668097

RESUMO

BACKGROUND: Evidence of clinical impact of PPM after TAVI is conflicting and might vary according to the type of valve implanted. AIMS: To assess the clinical impact of prosthesis-patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI) with balloon-expandable (BEV) and self-expandable valves (SEV) in patients with small annuli. METHODS: TAVI-SMALL 2 enrolled 628 patients in an international retrospective registry, which included patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 ) treated with transfemoral TAVI at 16 high-volume centers between 2011 and 2020. Analyses were performed comparing patients with less than moderate (n = 452), moderate (n = 138), and severe PPM (n = 38). Primary endpoint was incidence of all-cause mortality. Predictors of all-cause mortality and PPM were investigated. RESULTS: At a median follow-up of 380 days (interquartile range: 210-709 days), patients with severe PPM, but not moderate PPM, had an increased risk of all-cause mortality when compared with less than moderate PPM (log-rank p = 0.046). Severe PPM predicted all-cause mortality in patients with BEV (hazard ratio [HR]: 5.20, 95% confidence interval [CI]: 1.27-21.2) and intra-annular valves (IAVs, HR: 4.23, 95% CI: 1.28-14.02), and it did so with borderline significance in the overall population (HR: 2.89, 95% CI: 0.95-8.79). Supra-annular valve (SAV) implantation was the only predictor of severe PPM (odds ratio: 0.33, 95% CI: 0.13-0.83). CONCLUSIONS: Patients with small aortic annuli and severe PPM after TAVI have an increased risk of all-cause mortality at early term follow-up, especially after IAV or BEV implantation. TAVI with SAV protected from severe PPM.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Estudos Retrospectivos , Desenho de Prótese , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos
7.
Catheter Cardiovasc Interv ; 102(6): 1048-1056, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37933728

RESUMO

BACKGROUND: Percutaneous treatment for ostial left circumflex artery (LCx) lesions is known to be associated with suboptimal results. AIMS: The present study aims to assess the procedural and long-term clinical outcomes of percutaneous coronary intervention (PCI) for de novo ostial LCx lesions overall and according to the coronary revascularization strategy. METHODS: Consecutive patients undergoing PCI with second generation drug eluting stents or drug coated balloons for de novo ostial LCx lesions in three high-volume Italian centers between 2012 and 2021 were retrospectively evaluated. The primary endpoint was target-vessel revascularization (TVR) at 2 years. Secondary endpoints included major adverse cardiovascular and cerebrovascular events (MACCE), target lesion revascularization, myocardial infarction, stroke, all-cause death, and repeat revascularization. RESULTS: A total of 366 patients were included in the analysis with a median follow-up of 901 (IQR: 450-1728) days. 79.5% of the patients were male, 33.6% were diabetic, 49.7% had a previous PCI, and 23.1% a prior surgical revascularization. Very ostial LCx stenting was performed in 34.1%, crossover from left main to LCx in 17.3%, and a two-stent strategy in 48.6% of cases, respectively. In the overall population, the incidence of TVR at 2 years was 19.0% while MACCE rate was 25.7%. No major differences in clinical outcomes were found according to the stenting strategy. Use of intracoronary imaging was associated with fewer MACCE (HR: 0.47, 95% CI: 0.25-1.13, p = 0.01), while the diameter of the stent implanted in the ostial LCx was associated with less TVR (HR: 0.43, 95% CI: 0.25-0.75, p = 0.002). CONCLUSIONS: Percutaneous revascularization of the ostial LCx is associated with a high rate of TVR, regardless of the stenting strategy. Intracoronary imaging and proper stent sizing may reduce the failure rates.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Masculino , Feminino , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Estudos Retrospectivos , Resultado do Tratamento , Angiografia Coronária/métodos
8.
Rev Cardiovasc Med ; 23(2): 76, 2022 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-35229567

RESUMO

Tricuspid regurgitation (TR) has a considerable prevalence in the overall population, that further increases in selected categories of patients. Three morphologic types of TR prevail, namely primary, secondary and atrial TR, mostly, but not always, occurring in different subsets of patients. Recent evidences demonstrate a negative impact of TR on outcomes, irrespective of etiology and even when less than severe in grading. Unfortunately, current surgical standards are void of strong prospective evidence of positive impact on clinical outcomes. While on one hand recent advances in diagnosis and risk stratification of patients with TR are shedding light onto the population that may benefit from intervention and its appropriate timing, on the other hand the arrival on stage of percutaneous treatment options is widening even more the therapeutic options for such population. In this review we will address and discuss the available evidence on the prognostic impact of TR in different clinical contexts encountered in practice.


Assuntos
Insuficiência da Valva Tricúspide , Humanos , Prognóstico , Estudos Prospectivos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/terapia
9.
Catheter Cardiovasc Interv ; 100(5): 903-909, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36040688

RESUMO

OBJECTIVES: To report the experience of a high-volume center with balloon-expandable (BE) stents implantation to manage vascular complications after transcatheter aortic valve replacement (TAVR). BACKGROUND: Despite increased operator experience and better devices, vascular complications after TAVR are still a major issue and covered stent implantation is often required. METHODS: We retrospectively collected baseline and procedural data about 78 consecutive patients who underwent BE stent implantation to manage a vascular complication after transfemoral TAVR. Primary endpoints were technical success, incidence of new-onset claudication and need for vascular interventions during long-term follow-up. Secondary endpoints included length of hospitalization, in-hospital and 30-day mortality, and major postoperative complications. RESULTS: BE stents implantation to manage vascular complications after TAVR was successfully performed in 96.2% of the cases, with bailout surgery required in two cases. One patient suffered in-hospital death. Predischarge Doppler Ultrasound revealed no cases of in-stent occlusion or fracture. At a median follow-up of 429 days (interquartile range, 89-994 days), no cases of symptomatic leg ischemia were reported and only one patient experienced new-onset claudication. CONCLUSIONS: Our experience showed good periprocedural and long-term results of BE covered stent implantation to manage vascular complication after TAVR. Their great radial outward force may guarantee effective hemostasis without necessarily being associated with stent deformation/fracture resulting in restenosis or further interventions. More research is needed to define the role of BE covered stents in this setting.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Doenças Vasculares , Humanos , Seguimentos , Estudos Retrospectivos , Mortalidade Hospitalar , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Resultado do Tratamento , Stents , Doenças Vasculares/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
10.
Catheter Cardiovasc Interv ; 97(3): 443-450, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-31967390

RESUMO

Contrast-induced acute kidney injury (CI-AKI) represents a common but serious complication of percutaneous coronary interventions (PCI)-and in general of all those examinations requiring iodinated contrast injection-which affects not only renal function but also long-term prognosis. While several prophylactic approaches were designed in order to prevent CI-AKI, most failed to demonstrate clear benefits in randomized trials, and their implementation is therefore discouraged in clinical practice. The most notorious examples include pre-procedural bicarbonate or N-acetylcysteine, and preprocedural withdrawal of ACE inhibitors/Angiotensin receptor blockers. Those strategies that were instead demonstrated effective include the appropriate use of preprocedural hydration, reduction in contrast volume utilization, adoption of techniques for zero- or ultra-low-contrast procedures, and pharmacological treatments with statins. In this brief review, we summarize the main preventive strategies into brief and pragmatic recommendations designed to improve everyday clinical practice.


Assuntos
Injúria Renal Aguda , Intervenção Coronária Percutânea , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/prevenção & controle , Meios de Contraste/efeitos adversos , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 97(7): E900-E910, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33201611

RESUMO

OBJECTIVES AND BACKGROUND: Iatrogenic aorto-coronary dissection (ICD) is one of the most feared complications of interventional cardiology. Although rare, it is characterized by anterograde coronary ischemia and a concomitant aortic dissection, with potentially fatal consequences. METHODS: We present an example case of IACD and an accurate case-series review of the literature including 125 published cases. RESULTS: There were no significant predisposing factors and the IACD occurred equally in elective and urgent procedures. A significant number of IACDs were associated with CTO procedures. The factors associated with a worse outcome were hemodynamic instability, the presence of anterograde ischemia, and the extent of dissection according to the Dunning classification. Bail-out stenting was the most used strategy and its failure was associated with mortality. CONCLUSION: The main features of IACD are anterograde ischemia, retrograde dissection, and hemodynamic instability, each of them should be addressed with no time delay, possibly with bailout stenting, the most employed exit-strategy. According to our proposed algorithm, a shock team approach is required to coordinate the interdisciplinary skills and enabled patients to receive the best treatment.


Assuntos
Dissecção Aórtica , Vasos Coronários , Humanos , Aorta , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/etiologia , Dissecção Aórtica/cirurgia , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Dissecação , Doença Iatrogênica , Resultado do Tratamento
12.
Catheter Cardiovasc Interv ; 98(3): 595-604, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33586278

RESUMO

BACKGROUND: Valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) is an emerging alternative to re-do surgery. However, the challenge of coronary access (CA) following ViV-TAVR is a potential limitation as TAVR expands to younger lower-risk populations. OBJECTIVES: Using post-implantation computed tomography (CT) scans to evaluate the geometrical relationship between coronary ostia and valve frame in patients undergoing ViV-TAVR with the ACURATE neo valve. METHODS: Post-implant CT scans of 18 out of 20 consecutive patients treated with the ACURATE neo valve were analyzed. Coronary ostia location in relation to the highest plane (HP) (highest point of the ACURATE neo or surgical valve) was determined. Ostia located below the highest plan were further subclassified according to the gap available between the transcatheter heart valve frame and ostium (transcatheter-to-coronary [TTC] distance). The impact implantation depth has on these geometrical relationships was evaluated. RESULTS: A total of 21 out of 36 coronary ostia (58%) were located below the level of the HP with the left coronary artery (36%) more likely to be affected than the right (22%). Further sub-classification of these ostia revealed a large (>6 mm), moderate (4-6 mm), and small (<4 mm) TTC distance in 57% (12/21), 38% (8/21), and in 6% (1/18) of cases, respectively. At an implantation depth <4 mm compared to >4 mm, all ostia were located below the HP with no difference in post-procedural mean gradients (14.5 mmHg ± 4.7 vs. 12.6 mmHg ± 5.8; p = .5, 95%CI 3.8-7.5). CONCLUSIONS: CA following ACURATE neo implantation for ViV-TAVR could potentially be challenging in a significant proportion of patients and specific consideration should be given to the implantation depth.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Tomografia , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 97(3): 411-420, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-32198845

RESUMO

OBJECTIVES: We aimed to evaluate the use of bare metal stent (BMS) implantation in current percutaneous coronary intervention (PCI) era, focusing on indications for use and clinical outcomes. BACKGROUND: Limited data on BMS usage in current clinical practice are available. METHODS: All patients who underwent PCI with at least one BMS implantation in 18 Italian centers from January 1, 2013 to December 31, 2017, were included in our registry. Rates of BMS use and reasons for BMS implantations were reported for the overall study period and for each year. Primary outcomes were mortality, bleeding (Bleeding Academic Research Consortium-BARC and Thrombolysis in Myocardial Infarction-TIMI non-CABG definitions), and major adverse cardiac events (MACE) defined as the composite of all-cause and cardiac death, any myocardial infarction, target vessel revascularization, or any stent thrombosis. RESULTS: Among 58,879 patients undergoing PCI in the study period, 2,117 (3.6%) patients (mean age 73 years, 69.7% males, 73.3% acute coronary syndrome) were treated with BMS implantation (2,353 treated lesions). The rate of BMS implantation progressively decreased from 10.1% (2013) to 0.3% (2017). Main reasons for BMS implantation were: ST-elevation myocardial infarction (STEMI) (23.1%), advanced age (24.4%), and physician's perception of high-bleeding risk (34.0%). At a mean follow-up of 2.2 ± 1.5 years, all-cause and cardiac mortality were 25.6 and 12.7%, respectively; MACE rate was 35.3%, any bleeding rate was 13.0% (BARC 3-5 bleeding 6.3%, TIMI non-CABG major bleeding 6.1%). CONCLUSION: In a large, contemporary, real-world, multicenter registry, BMS use progressively reduced over the last 5 years. Main reasons for BMS implantation were STEMI, advanced age, and physician's perception of high-bleeding risk. High rates of mortality and MACE were observed in this real-world high-risk population.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Feminino , Humanos , Itália , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Stents , Resultado do Tratamento
14.
Pacing Clin Electrophysiol ; 44(7): 1216-1223, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34110038

RESUMO

BACKGROUND: Gastrointestinal bleeding (GIB) is associated with a high recurrence rate and a prior GIB episode is common in real-world left atrial appendage closure (LAAC) recipients. The present study sought to evaluate the clinical characteristics and outcomes of patients with prior GIB undergoing LAAC, and to determine the factors associated with and clinical impact of GIB recurrence. METHODS: Multicenter study including 277 consecutive patients who underwent percutaneous LAAC and had prior GIB. All-cause death, all bleeding, GIB recurrence, and clinical ischemic stroke were recorded. RESULTS: After a median follow-up of 17 (interquartile range: 6-37) months post-LAAC, the rates of death, bleeding, GIB recurrence, and ischemic stroke were 14.0 per 100 person-year (PY), 29.3 per 100 PY, 17.7 per 100 PY, and 1.1 per 100 PY, respectively. GIB recurrence occurred within 3 months post-LAAC in 55.8% of patients. A previous lower GIB (vs. upper or unclassified) (HR: 1.76; 95% CI: 1.09-2.82; p = .020) and eGFR < 45 mL/min (HR: 1.70; 95% CI:1.04-2.67; p = .033) determined an increased risk of GIB recurrence. By multivariable analysis, eGFR < 45 mL/min (HR: 2.72; 95% CI: 1.70-4.34; p < .001), GIB recurrence following LAAC (HR: 2.15; 95% CI: 1.33-3.46; p = .002), diabetes mellitus (HR: 1.77; 95% CI: 1.10-2.84; p = .018), and age (HR: 1.06; 95% CI: 1.03-1.10; p < .001) were associated with an increased mortality. CONCLUSIONS: Patients with prior GIB undergoing LAAC exhibited a relatively low rate of GIB recurrence, and prior lower GIB and moderate-to-severe chronic kidney disease determined an increased risk. GIB recurrence was associated with an increased mortality.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Hemorragia Gastrointestinal/complicações , Hemorragia Gastrointestinal/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Incidência , Masculino , Recidiva , Resultado do Tratamento
15.
Curr Cardiol Rep ; 23(10): 137, 2021 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-34410511

RESUMO

PURPOSE OF THE REVIEW: Annular-based strategies for treating tricuspid valve (TV) regurgitation do not always have satisfactory long-term outcomes. Management of failed TV annuloplasty can be challenging and requires a dedicated heart team approach. This review explores the treatment options available for failed TV annuloplasty. RECENT FINDINGS: Recent developments and novel percutaneous treatment options have emerged as promising alternatives for patients with failed TV annuloplasty. Leaflet-based interventions, valve-in-valve procedures, transcatheter tricuspid valves and new-generation trans-caval valves are all feasible options, which can assure good results whilst minimizing risks for the patient. Failure of tricuspid annuloplasty is not uncommon amongst patients treated with either a tricuspid ring or suture-based device. The complex anatomy, physiology and clinical risk profile should be carefully evaluated on an individual patient-by-patient basis in order to select the most appropriate clinical and percutaneous treatment strategy. Different transcatheter tricuspid valve repair or replacement techniques may provide an attractive alternative treatment option for managing this challenging patient cohort.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Tricúspide , Valva Aórtica , Humanos , Valva Mitral/cirurgia , Recidiva , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
16.
Catheter Cardiovasc Interv ; 96(1): 225-227, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31785122

RESUMO

In the last years, the use of sutureless devices in frail patients with severe aortic stenosis has increased thanks to their "easier and faster" technique of implantation in comparison to conventional surgery. Results from metanalysis show comparable outcomes in comparison to transcatheter aortic valve replacement (TAVR) in terms of mortality, stroke incidence, and rate of pace-maker implantation. The incidence of para-valvular leak (PVL) is even lower for sutureless devices than for TAVR. The few cases described are generally due to incomplete decalcification or incorrect valve sizing and consequent stent distortion. To our knowledge this is the first case describing PVL with massive aortic regurgitation due to early partial embolization of a Perceval valve and its successfully treatment with valve-in-valve by using a self-expanding TAVR device.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Migração de Corpo Estranho/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Procedimentos Cirúrgicos sem Sutura/instrumentação , Idoso , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Desenho de Prótese , Índice de Gravidade de Doença , Procedimentos Cirúrgicos sem Sutura/efeitos adversos , Resultado do Tratamento
17.
Eur Heart J ; 40(38): 3156-3165, 2019 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-31230081

RESUMO

AIMS: Peri-procedural transcatheter valve embolization and migration (TVEM) is a rare but potentially devastating complication of transcatheter aortic valve implantation (TAVI). We sought to assess the incidence, causes, and outcome of TVEM in a large multicentre cohort. METHODS AND RESULTS: We recorded cases of peri-procedural TVEM in patients undergoing TAVI between January 2010 and December 2017 from 26 international sites. Peri-procedural TVEM occurred in 273/29 636 (0.92%) TAVI cases (age 80.8 ± 7.3 years; 53.8% female), of which 217 were to the ascending aorta and 56 to the left ventricle. The use of self-expanding or first-generation prostheses and presence of a bicuspid aortic valve were independent predictors of TVEM. Bail-out measures included repositioning attempts using snares or miscellaneous tools (41.0%), multiple valve implantations (83.2%), and conversion to surgery (19.0%). Using 1:4-propensity matching, we identified a cohort of 235 patients with TVEM (TVEMPS) and 932 patients without TVEM (non-TVEMPS). In the matched cohort, all-cause mortality was higher in TVEMPS than in non-TVEMPS at 30 days (18.6% vs. 4.9%; P < 0.001) and after 1 year (30.5% vs. 16.6%; P < 0.001). Major stroke was more frequent in TVEMPS at 30 days (10.6% vs. 2.8%; P < 0.001), but not at 1 year (4.6% vs. 1.9%; P = 0.17). The need for emergent cardiopulmonary support, major stroke at 30 days, and acute kidney injury Stages 2 and 3 increased the risk of 1-year mortality, whereas a better renal function at baseline was protective. CONCLUSION: Transcatheter valve embolization and migration occurred in approximately 1% and was associated with increased morbidity and mortality.


Assuntos
Embolia , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias , Falha de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Embolia/epidemiologia , Embolia/etiologia , Embolia/mortalidade , Feminino , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Falha de Prótese/efeitos adversos , Falha de Prótese/etiologia , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Resultado do Tratamento
18.
Catheter Cardiovasc Interv ; 93(3): 522-529, 2019 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-30286515

RESUMO

OBJECTIVES: This study aimed to predict the displacement of self-expanding transcatheter heart valves (THV) during final deployment. BACKGROUND: Accurate device positioning during transcatheter aortic valve implantation (TAVI) is crucial for optimal results. METHODS: At our institution, 103 patients who underwent transfemoral TAVI with Evolut R were retrospectively identified. Multiple linear regression models were created, and a predictor equation was built to quantify the factors that may affect THV behavior. RESULTS: Multiple linear regression analysis for THV displacement on the left coronary cusp (LCC) identified the angle between the THV and the ascending aorta (ATA), predilation, and less operator experience as independent predictors of upward displacement, whereas estimated glomerular filtration rate (eGFR) was inversely related with THV behavior (95% confidence interval: 0.219 to 0.340, 0.447 to 2.092, 0.165 to 1.757, and -0.053 to -0.011, respectively). Predictors of THV displacement on the noncoronary cusp side could not be identified using this model. CONCLUSIONS: The ATA at the point of recapture, predilation, and less operator experience were independent predictors of upward displacement of THV on the LCC side. eGFR was an independent predictor of THV downward displacement on the LCC side. Of them, the ATA was the strongest predictor. Physicians may need to adjust this angle adequately before deployment to achieve the appropriate position.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
19.
Catheter Cardiovasc Interv ; 94(4): 571-577, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30773795

RESUMO

OBJECTIVES: The aims of this study were to evaluate the long-term clinical outcomes after coronary covered stent (CS) implantation and to compare the results according to the indications. BACKGROUND: To date, data on the long-term follow-up of coronary CS are limited, and no studies have been conducted to compare outcomes on the basis of specific lesions treated. METHODS: A total of 190 consecutive patients (212 lesions) implanted with CS and surviving until discharge between May 1997 and February 2017 were enrolled in this retrospective study. Clinical outcomes were evaluated and compared using the Gehan-Breslow-Wilcoxon test. RESULTS: CS was mainly used for the treatment of a saphenous vein graft (SVG) (51.4%), followed by coronary artery perforation (CAP) (25.0%) and coronary artery aneurysm (CAA) (11.8%). The median follow-up duration was 6.0 (interquartile range: 1.6-13.5) years. Target vessel myocardial infarction (MI), target vessel occlusion, target lesion revascularization, and stent thrombosis, frequently occurred in the early follow-up period (7.3%, 16.6%, 21.5%, and 8.9% at 1 year, respectively) and continued to increase throughout the long-term follow-up (14.8%, 38.6%, 38.7%, and 17.8% at 10 years, respectively). Target vessel occlusion, target vessel MI, and ST were not identified in CAA with superiority to CAP (Gehan-Breslow-Wilcoxon p-value = 0.010, 0.047, and 0.046, respectively). SVG had a higher rate of target vessel occlusion than CAA (p = 0.004). CONCLUSIONS: Clinical events after CS implantation frequently occurred in the early period and steadily increased in the long-term period. CS implantation in CAA was associated with fewer adverse cardiac events and may lead to safe and acceptable outcomes. However, CS implanted in CAP and SVG are associated with a high risk of long-term cardiac events.


Assuntos
Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Bases de Dados Factuais , Feminino , Seguimentos , Humanos , Itália , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
Catheter Cardiovasc Interv ; 91(5): 966-974, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-28941127

RESUMO

BACKGROUND: Second generation transcatheter aortic valve implantation (TAVI) devices have been designed to reduce the rate of paravalvular leak (PVL) and other complications. An important technological advancement has been the ability to fully reposition devices to facilitate optimal implantation depth and position to reduce the likelihood of PVL. OBJECTIVES: To compare procedural and 30-day outcomes according to the Valve Academic Research Consortium (VARC)-2 criteria following TAVI with the fully repositionable and retrievable Lotus and DFM devices. METHODS AND RESULTS: 175 patients with severe aortic stenosis underwent transfemoral TAVI with the Lotus (n = 60) and DFM (n = 115) valve. Baseline clinical characteristics did not differ between the two groups. All devices were successfully implanted, with one case of valve embolization in the Lotus group. Device success (95 vs. 98.2%, P = 0.89), VARC-defined combined safety (90 vs. 93%, P = 0.48), and clinical efficacy (86.7 vs. 90.4%, P = 0.65) rates at 30-days were similar between Lotus and DFM groups. There was no severe PVL; one patient in both Lotus and DFM group developed moderate PVL after the procedure. The Lotus valve was associated with a higher rate of new pacemaker implantation (37.3 vs. 11.2%, P < 0.001) and a lower mean aortic gradient (9.4 ± 5 vs. 12.3 ± 5, P < 0.001) at 30-days as compared with the DFM valve. CONCLUSIONS: In this single-center, retrospective analysis, both Lotus and DFM devices demonstrated excellent device success, safety and efficacy at 30-day follow-up. The DFM valve was associated with minimally higher transvalvular gradients but lower new pacemaker implantation rates when compared to the Lotus valve.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Feminino , Hemodinâmica , Humanos , Itália , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Desenho de Prótese , Recuperação de Função Fisiológica , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA