Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Perinat Med ; 51(7): 920-924, 2023 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-37097825

RESUMO

OBJECTIVES: The aim of this study was to evaluate the agreement between visual and automatic methods in assessing the adequacy of fetal cardiac views obtained during second trimester ultrasonographic examination. METHODS: In a prospective observational study frames of the four-chamber view left and right outflow tracts, and three-vessel trachea view were obtained from 120 consecutive singleton low-risk women undergoing second trimester ultrasound at 19-23 weeks of gestation. For each frame, the quality assessment was performed by an expert sonographer and by an artificial intelligence software (Heartassist™). The Cohen's κ coefficient was used to evaluate the agreement rates between both techniques. RESULTS: The number and percentage of images considered adequate visually by the expert or with Heartassist™ were similar with a percentage >87 % for all the cardiac views considered. The Cohen's κ coefficient values were for the four-chamber view 0.827 (95 % CI 0.662-0.992), 0.814 (95 % CI 0.638-0.990) for left ventricle outflow tract, 0.838 (95 % CI 0.683-0.992) and three vessel trachea view 0.866 (95 % CI 0.717-0.999), indicating a good agreement between the two techniques. CONCLUSIONS: Heartassist™ allows to obtain the automatic evaluation of fetal cardiac views, reached the same accuracy of expert visual assessment and has the potential to be applied in the evaluation of fetal heart during second trimester ultrasonographic screening of fetal anomalies.


Assuntos
Cardiopatias Congênitas , Gravidez , Feminino , Humanos , Segundo Trimestre da Gravidez , Cardiopatias Congênitas/diagnóstico por imagem , Inteligência Artificial , Estudos Prospectivos , Coração Fetal/diagnóstico por imagem , Algoritmos , Ultrassonografia Pré-Natal/métodos
2.
Am J Obstet Gynecol ; 225(2): 171.e1-171.e12, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33675795

RESUMO

BACKGROUND: To date, no research has focused on the sonographic quantification of the degree of flexion of the fetal head in relation to the labor outcome in women with protracted active phase of labor. OBJECTIVE: This study aimed to assess the relationship between the transabdominal sonographic indices of fetal head flexion and the mode of delivery in women with protracted active phase of labor. STUDY DESIGN: Prospective evaluation of women with protracted active phase of labor recruited across 3 tertiary maternity units. Eligible cases were submitted to transabdominal ultrasound for the evaluation of the fetal head position and flexion, which was measured by means of the occiput-spine angle in fetuses in nonocciput posterior position and by means of the chin-to-chest angle in fetuses in occiput posterior position. The occiput-spine angle and the chin-to-chest angle were compared between women who had vaginal delivery and those who had cesarean delivery. Cases where obstetrical intervention was performed solely based on suspected fetal distress were excluded. RESULTS: A total of 129 women were included, of whom 43 (33.3%) had occiput posterior position. Spontaneous vaginal delivery, instrumental delivery, and cesarean delivery were recorded in 66 (51.2%), 17 (13.1%), and 46 (35.7%) cases, respectively. A wider occiput-spine angle was measured in women who had vaginal delivery compared with those submitted to cesarean delivery owing to labor dystocia (126±14 vs 115±24; P<.01). At the receiver operating characteristic curve, the area under the curve was 0.675 (95% confidence interval, 0.538-0.812; P<.01), and the optimal occiput-spine angle cutoff value discriminating between cases of vaginal delivery and those delivered by cesarean delivery was 109°. A narrower chin-to-chest angle was measured in cases who had vaginal delivery compared with those undergoing cesarean delivery (27±33 vs 56±28 degrees; P<.01). The area under the curve of the chin-to-chest angle in relation to the mode of delivery was 0.758 (95% confidence interval, 0.612-0.904; P<.01), and the optimal cutoff value discriminating between vaginal delivery and cesarean delivery was 33.0°. CONCLUSION: In women with protracted active phase of labor, the sonographic demonstration of fetal head deflexion in occiput posterior and in nonocciput posterior fetuses is associated with an increased incidence of cesarean delivery owing to labor dystocia. Such findings suggest that intrapartum ultrasound may contribute in the categorization of the etiology of labor dystocia.


Assuntos
Cesárea/estatística & dados numéricos , Distocia/diagnóstico por imagem , Extração Obstétrica/estatística & dados numéricos , Feto/diagnóstico por imagem , Apresentação no Trabalho de Parto , Primeira Fase do Trabalho de Parto , Adulto , Parto Obstétrico/estatística & dados numéricos , Distocia/terapia , Feminino , Cabeça/diagnóstico por imagem , Humanos , Modelos Logísticos , Pescoço/diagnóstico por imagem , Gravidez , Coluna Vertebral/diagnóstico por imagem , Ultrassonografia
3.
Acta Obstet Gynecol Scand ; 100(6): 1034-1039, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33604901

RESUMO

INTRODUCTION: Our objective was to compare the fetal growth velocity and fetal hemodynamics in pregnancies complicated and in those not complicated by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. MATERIAL AND METHODS: Prospective case-control study of consecutive pregnancies complicated by SARS-CoV-2 infection during the second half of pregnancy matched with unaffected women. The z scores of head circumference, abdominal circumference, femur length, and estimated fetal weight were compared between the two groups. Fetal growth was assessed by analyzing the growth velocity of head circumference, abdominal circumference, femur length, and estimated fetal weight between the second- and third-trimester scans. Similarly, changes in the pulsatility index of uterine, umbilical, and middle cerebral arteries, and their ratios were compared between the two study groups. RESULTS: Forty-nine consecutive pregnancies complicated, and 98 not complicated, by SARS-CoV-2 infection were included. General baseline and pregnancy characteristics were similar between pregnant women with and those without SARS-CoV-2 infection. There was no difference in head circumference, abdominal circumference, femur length, and estimated fetal weight z scores between pregnancies complicated and those not complicated by SARS-CoV-2 infection at both the second- and third-trimester scans. Likewise, there was no difference in the growth velocity of all these body parameters between the two study groups. Finally, there was no difference in the pulsatility index of both maternal and fetal Doppler scans throughout gestation between the two groups. CONCLUSIONS: Pregnancies complicated by SARS-CoV-2 infection are not at higher risk of developing fetal growth restriction through impaired placental function. The findings from this study do not support a policy of increased fetal surveillance in these women.


Assuntos
COVID-19/complicações , Desenvolvimento Fetal , Hemodinâmica , Complicações Infecciosas na Gravidez/virologia , Fluxo Pulsátil , Adulto , Biometria , Estudos de Casos e Controles , Feminino , Idade Gestacional , Humanos , Gravidez , Segundo Trimestre da Gravidez , Terceiro Trimestre da Gravidez , Estudos Prospectivos , SARS-CoV-2 , Ultrassonografia Doppler
4.
Acta Obstet Gynecol Scand ; 100(11): 1941-1948, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34314520

RESUMO

INTRODUCTION: The objective was to report the role of intrapartum ultrasound examination in affecting maternal and perinatal outcome in women undergoing instrumental vaginal delivery. MATERIAL AND METHODS: MEDLINE, Embase, CINAHL, Google Scholar and ClinicalTrial.gov databases were searched. Inclusion criteria were randomized controlled trials comparing ultrasound assessment of fetal head position vs routine standard care (digital examination) before instrumental vaginal delivery (either vacuum or forceps). The primary outcome was failed instrumental delivery extraction followed by cesarean section. Secondary outcomes were postpartum hemorrhage, 3rd or 4th degree perineal lacerations, episiotomy, prolonged hospital stay, Apgar score<7 at 5 min, umbilical artery pH <7.0 and base excess greater than -12 mEq, admission to neonatal intensive care unit (NICU), shoulder dystocia, birth trauma, a composite score of adverse maternal and neonatal outcome and incorrect diagnosis of fetal head position. Risk of bias was assessed using the Revised Cochrane risk-of-bias tool for randomized trials (RoB-2). The quality of evidence and strength of recommendations were assessed using the Grading of Recommendations Assessment Development and Evaluation (GRADE) methodology. Head-to-head meta-analyses using a random-effect model were used to analyze the data and results are reported as relative risk with their 95% confidence intervals. RESULTS: Five studies were included (1463 women). There was no difference in the maternal, pregnancy or labor characteristics between the two groups. An ultrasound assessment prior to instrumental vaginal delivery did not affect the cesarean section rate compared with standard care (p = 0.805). Likewise, the risk of composite adverse maternal outcome (p = 0.428), perineal lacerations (p = 0.800), postpartum hemorrhage (p = 0.303), shoulder dystocia (p = 0.862) and prolonged stay in hospital (p = 0.059) were not different between the two groups. Composite adverse neonatal outcome was not different between the women undergoing and those not undergoing ultrasound assessment prior to instrumental delivery (p = 0.400). Likewise, there was no increased risk with abnormal Apgar score (p = 0.882), umbilical artery pH < 7.2 (p = 0.713), base excess greater than -12 (p = 0.742), admission to NICU (p = 0.879) or birth trauma (p = 0.968). The risk of having an incorrect diagnosis of fetal head position was lower when ultrasound was performed before instrumental delivery, with a relative risk of 0.16 (95% confidence interval 0.1-0.3; I2 :77%, p < 0.001). CONCLUSIONS: Although ultrasound examination was associated with a lower rate of incorrect diagnoses of fetal head position and station, this did not translate to any improvement of maternal or neonatal outcomes.


Assuntos
Extração Obstétrica/métodos , Resultado da Gravidez , Ultrassonografia Pré-Natal , Traumatismos do Nascimento/etiologia , Cesárea/estatística & dados numéricos , Feminino , Humanos , Hemorragia Pós-Parto/etiologia , Gravidez
5.
J Clin Med ; 11(19)2022 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-36233661

RESUMO

The number of pregnancies achieved using in vitro fertilization (IVF) is rapidly increasing around the world. The chance of obtaining a successful pregnancy is also significantly improved due to technological advances and improvement in infertility treatment. Despite this success, there is evidence that pregnancy conceived by IVF has an increased risk of adverse maternal and perinatal outcome mainly represented by the development of hypertensive diseases, pre-eclampsia, and fetal growth restriction. Although different cofactors may play a role in the genesis of these diseases, the development of the placenta has a pivotal function in determining pregnancy outcomes. Advances in ultrasound technology already allows for evaluation in the first trimester, the impedance to flow in the uterine artery, and the placental volume using Doppler and three-dimensional techniques. This review article aims to describe the modification occurring in placental volume and hemodynamics after IVF and to summarize the differences present according to the type of IVF (fresh vs. frozen-thawed embryos).

6.
J Matern Fetal Neonatal Med ; 35(22): 4381-4385, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33228405

RESUMO

OBJECTIVE: There is a lack of evidence on whether to favor cerebroplacental ratio (CPR) or umbilicocerebral ratio (UCR) when assessing pregnancies at risk of fetal growth restriction. The Recent evidences highlight a significant heterogeneity in the methodology of previously published studies reporting reference ranges for Doppler indices, which may affect the clinical applicability of these charts. The aim of this study was to develop charts of UCR based upon a recently proposed standardized methodology and using quantile regression. METHODS: This was a secondary analysis of a prospective cross-sectional study including low-risk singleton pregnancies between 24 and 40 weeks of gestation undergoing Doppler recordings. The UCR centile values were established by quantile regression at different gestational age intervals. Quantile regression analysis was used to build the UCR chart. RESULT: 2516 low- risk singleton pregnancies were included in the analysis. UCR decreased with advancing gestational age. The 3rd, 5th 10th, 50th, 90th, 95th, and 97th centiles according to gestational age are provided, as well as equations to allow calculation of any other percentile. CONCLUSIONS: We have established gestational age-specific normative centiles reference limits for UCR.


Assuntos
Artéria Cerebral Média , Ultrassonografia Pré-Natal , Estudos Transversais , Feminino , Retardo do Crescimento Fetal , Idade Gestacional , Humanos , Artéria Cerebral Média/diagnóstico por imagem , Gravidez , Estudos Prospectivos , Valores de Referência , Ultrassonografia Pré-Natal/métodos , Artérias Umbilicais/diagnóstico por imagem
7.
J Matern Fetal Neonatal Med ; 35(25): 7139-7145, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34340644

RESUMO

OBJECTIVE: To explore the strength of association and the diagnostic accuracy of maternal hemodynamic parameters detected noninvasively in predicting an adverse perinatal outcome in labor. METHODS: Prospective cohort study of singleton women undergoing antepartum care at 37-39 weeks of gestation. A noninvasive ultrasonic cardiac output monitor (USCOM®) was used for cardiovascular assessment. The study outcome was a composite score of adverse perinatal outcome, which included at least one of the following variables: Cesarean or instrumental delivery for abnormal fetal heart monitoring, umbilical artery pH <7.10 or admission to neonatal special care unit. Attending clinicians were blinded to maternal cardiovascular indices. Multivariate logistic regression and area under the curve (AUC) analyses were used to test the diagnostic accuracy of different maternal and ultrasound characteristics in predicting adverse perinatal outcome. RESULTS: A total of 133 women were recruited. The rate of adverse perinatal outcome was 25.6% (34/133). Women who delivered without abnormal perinatal outcome (controls) were more likely to be parous, compared to those who had an adverse perinatal outcome (44.4 vs. 73.5%; p = .005). Control women had significantly lower systemic vascular resistance (SVR) (median, 1166 vs. 1352 dynes × s/cm5, p = .023) and SVR index (SVRI) (median, 2168 vs. 2627 dynes × s/cm5/m2, p = .039) compared to women who had an adverse perinatal outcome. In this latter group the prevalence of SV <50 ml was significantly higher than in the control group (38.2% (13/34) vs. 11.1%, (11/99) p = .0012). At multivariable logistic regression analysis, SVR (aOR 1.307; 95% CI 1.112-2.23), SV <50 ml (aOR 4.70; 95% CI 1.336-12.006) and parity (3.90: 95% CI 1.545-10.334) were the only variables independently associated with adverse perinatal outcome. A model considering only SVR showed an AUC of 0.631. Integration of SVR with SV <50 ml and parity significantly improves the diagnostic performance of SVR alone to predict adverse outcome (AUC 0.732; p = .016). CONCLUSION: Pre-labor modifications of maternal cardiovascular variables are associated with adverse perinatal outcome. However, their predictive accuracy for perinatal compromise is low, and thus their use as standalone screening test for adverse perinatal outcome in singleton pregnancies at term is not supported.


Assuntos
Sofrimento Fetal , Resultado da Gravidez , Gravidez , Recém-Nascido , Feminino , Humanos , Sofrimento Fetal/diagnóstico , Sofrimento Fetal/epidemiologia , Estudos Prospectivos , Resultado da Gravidez/epidemiologia , Ultrassonografia Pré-Natal , Artérias Umbilicais/diagnóstico por imagem
8.
J Matern Fetal Neonatal Med ; 35(25): 7787-7793, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34121577

RESUMO

OBJECTIVE: Universal elective induction of labor (IOL) in singleton parous pregnancies has been advocated to reduce the rate of cesarean section (CD), without impacting on maternal outcome. However, about 50% of women deliver after 40 weeks; therefore, an accurate estimation of the time of delivery might avoid unnecessary early IOL. The aim of this study was to test the diagnostic accuracy of ultrasound in predicting delivery ≥40 weeks of gestation in singleton parous women. METHODS: Prospective cohort study of singleton parous women undergoing a dedicated ultrasound assessment at 36-38 weeks of gestation. The primary outcome was spontaneous vaginal delivery ≥40 weeks of gestation. Cervical length (CL), posterior cervical angle (PCA), sonoelastographic hardness ratio (HR), angle of progression (AoP) and head perineal distance (HPD) were measured. Multivariate logistic regression and area under the curve (AUC) analyses were used to test the diagnostic accuracy of different maternal and ultrasound characteristics in predicting delivery ≥40 weeks. RESULTS: 518 singleton pregnancies were included in the analysis and 235 (45.4%) delivered ≥40 weeks. CL (29 vs 19 mm; p ≤ .0001) and HPD (50 vs 47 mm; p = .001) were longer, HR higher (38.9 vs 35.5; p = .04), while PCA (98° vs 104°; p ≤ .0001) and AOP narrower (93° vs 98°; p = .029) in pregnancies delivered compared to those not delivered after 40 weeks of gestation. At multivariable logistic regression analysis, CL (aOR 1.206; 95% CI 1.164-1.250), HPD (aOR 1.127; 95% CI 1.066-1.191) and HR (aOR 1.022; 95% CI 1.003-1.041 were the only variables independently associated with delivery ≥40 weeks. CL showed had an AUC of 0.863 in predicting delivery ≥40 weeks of gestation, with an optimal cutoff of 23.5 mm. Integration of HPD and HR did not significantly improve the diagnostic performance of CL alone to predict delivery ≥40 weeks (AUC 0.870; p = .472). CONCLUSION: Cervical length at 36-38 weeks has a good diagnostic accuracy to predict spontaneous vaginal delivery at ≥40 weeks. Universal assessment of CL in the third trimester of pregnancy may help in identifying those women who may benefit of elective IOL at 39 weeks.


Assuntos
Cesárea , Ultrassonografia Pré-Natal , Feminino , Gravidez , Humanos , Estudos Prospectivos , Trabalho de Parto Induzido , Parto Obstétrico
9.
Minerva Obstet Gynecol ; 73(1): 94-102, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33215908

RESUMO

Intrapartum hypoxic events most commonly occur in low-risk pregnancies with appropriately grown fetuses. Continuous intrapartum monitoring by means of cardiotocography has not demonstrated a reduction in the frequency of adverse perinatal outcome but has been linked with an increase in the caesarean section rate, particularly among women considered at low risk. Available data from the literature suggests that abnormalities in the uterine artery Doppler and in the ratio between fetal cerebral and umbilical Doppler (i.e. cerebroplacental ratio [CPR]) are associated with conditions of subclinical placental function occurring in fetuses who have failed to achieve their growth potential regardless of their actual size. In this review we summarize the available evidence on the use of intrapartum Doppler ultrasound for the fetal surveillance during labor and the identification of the fetuses at risk of intrapartum distress.


Assuntos
Cesárea , Artérias Umbilicais , Feminino , Humanos , Artéria Cerebral Média/diagnóstico por imagem , Placenta/diagnóstico por imagem , Gravidez , Resultado da Gravidez , Fluxo Pulsátil , Ultrassonografia Doppler , Ultrassonografia Pré-Natal , Artérias Umbilicais/diagnóstico por imagem
10.
Minerva Obstet Gynecol ; 73(4): 423-434, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33904691

RESUMO

Fetal growth restriction (FGR) is defined as the inability of the fetus to reach its growth potential. According to the onset of the disease is defined early (<32 weeks) or late (≥32 weeks). FGR is associated with an increased risk of adverse short- and long-term outcomes, including hypoxemic events and neurodevelopmental delay compared to normally grown fetuses and increased risk of complications in the infanthood and adulthood. The underlying cause of FGR is placental insufficiency leading to chronic fetal hypoxia that affects cardiac hemodynamic with different mechanism in early and late onset growth restriction. In early onset FGR adaptive mechanisms involve the diversion of the cardiac output preferentially in favor of the brain and the heart, while abnormal arterial and venous flow manifest in the case of further worsening of fetal hypoxia. In late FGR the fetal heart shows a remodeling of its shape and function mainly related to a reduction of umbilical vein flow. In this review we discuss the modifications occurring at the level of the fetal cardiac hemodynamic in fetuses with early and late FGR.


Assuntos
Retardo do Crescimento Fetal , Insuficiência Placentária , Feminino , Coração Fetal , Humanos , Placenta , Gravidez , Veias Umbilicais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA