Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 175
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(10)2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38793866

RESUMO

In this presented study, we measured in situ the uplink duty cycles of a smartphone for 5G NR and 4G LTE for a total of six use cases covering voice, video, and data applications. The duty cycles were assessed at ten positions near a 4G and 5G base-station site in Belgium. For Twitch, VoLTE, and WhatsApp, the duty cycles ranged between 4% and 22% in time, both for 4G and 5G. For 5G NR, these duty cycles resulted in a higher UL-allotted time due to time division duplexing at the 3.7 GHz frequency band. Ping showed median duty cycles of 2% for 5G NR and 50% for 4G LTE. FTP upload and iPerf resulted in duty cycles close to 100%.

2.
BMC Oral Health ; 24(1): 437, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600533

RESUMO

OBJECTIVES: The trial aimed to compare the clinical performance and radiographic success of ACTIVA BioACTIVE versus Compomer in restoring class-II cavities of primary molars. MATERIALS AND METHODS: A non-inferior split-mouth design was considered. A pre-calculated sample size of 96 molars (48 per group) with class-2 cavities of twenty-one children whose ages ranged from 5 to 10 years were randomly included in the trial. Pre-operative Plaque Index (PI), DMFT/dmft scores and the time required to fill the cavity were recorded. Over 24 months, the teeth were clinically evaluated every six months and radiographically every 12 months by two calibrated and blinded evaluators using the United States public health service (USPHS)-Ryge criteria. The two-sided 95% confidence interval (CI) for the difference in success rate was considered to assess non-inferiority, and the margin was set at -18%. The linear mixed model and Firth's logistic regression model were used for data analysis (P < 0.05). RESULTS: After 24 months, 86 teeth (43 per group) were evaluated. The mean PI score was 1.1(± 0.9), while DMFT/dmft was 0.35 (± 0.74) and 6.55 (± 2.25) respectively. The clinical and radiographic success rate of Dyract vs. ACTIVA was 95.3% and 88.3% vs. 93% and 86%, respectively. The two-sided 95% CI for the difference in success rate (-2.3%) was - 3.2 to 1.3% and didn't reach the predetermined margin of -18% which had been anticipated as the non-inferiority margin. Clinically, ACTIVA had a significantly better colour match (P = 0.002) but worse marginal discolouration (P = 0.0143). There were no significant differences regarding other clinical or radiographic criteria (P > 0.05). ACTIVA took significantly less placement time than Dyract, with a mean difference of 2.37 (± 0.63) minutes (P < 0.001). CONCLUSION: The performance of ACTIVA was not inferior to Dyract and both materials had a comparable high clinical and radiographic performance in children with high-caries experience. ACTIVA had a significantly better colour match but more marginal discolouration. It took significantly less time to be placed in the oral cavity. TRIAL REGISTRATION: The study was registered at ClinicalTrials.gov on 4 May 2018 (#NCT03516838).


Assuntos
Compômeros , Cárie Dentária , Criança , Humanos , Pré-Escolar , Resinas Compostas , Restauração Dentária Permanente , Cárie Dentária/diagnóstico por imagem , Cárie Dentária/terapia , Dente Molar/diagnóstico por imagem
3.
Sensors (Basel) ; 23(3)2023 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-36772094

RESUMO

Fixed wireless access (FWA) provides a solution to compete with fiber deployment while offering reduced costs by using the mmWave bands, including the unlicensed 60 GHz one. This paper evaluates the deployment of FWA networks in the 60 GHz band in realistic urban and rural environment in Belgium. We developed a network planning tool that includes novel backhaul based on the IEEE 802.11ay standard with multi-objective capabilities to maximise the user coverage, providing at least 1 Gbps of bit rate while minimising the required network infrastructure. We evaluate diverse serving node locations, called edge nodes (EN), and the impact of environmental factors such as rain and vegetation on the network design. Extensive simulation results show that defining a proper EN's location is essential to achieve viable user coverage higher than 95%, particularly in urban scenarios where street canyons affect propagation. Rural scenarios require nearly 75 ENs per km2 while urban scenarios require four times (300 ENs per km2) this infrastructure. Finally, vegetation can reduce the coverage by 3% or increment infrastructure up to 7%, while heavy rain can reduce coverage by 5% or increment infrastructure by 15%, depending on the node deployment strategy implemented.

4.
Sensors (Basel) ; 23(6)2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36991856

RESUMO

Of particular interest within fifth generation (5G) cellular networks are the typical levels of radiofrequency (RF) electromagnetic fields (EMFs) emitted by 'small cells', low-power base stations, which are installed such that both workers and members of the general public can come in close proximity with them. In this study, RF-EMF measurements were performed near two 5G New Radio (NR) base stations, one with an Advanced Antenna System (AAS) capable of beamforming and the other a traditional microcell. At various positions near the base stations, with distances ranging between 0.5 m and 100 m, both the worst-case and time-averaged field levels under maximized downlink traffic load were assessed. Moreover, from these measurements, estimates were made of the typical exposures for various cases involving users and non-users. Comparison to the maximum permissible exposure limits issued by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) resulted in maximum exposure ratios of 0.15 (occupational, at 0.5 m) and 0.68 (general public, at 1.3 m). The exposure of non-users was potentially much lower, depending on the activity of other users serviced by the base station and its beamforming capabilities: 5 to 30 times lower in the case of an AAS base station compared to barely lower to 30 times lower for a traditional antenna.


Assuntos
Telefone Celular , Campos Eletromagnéticos , Humanos , Exposição Ambiental , Ondas de Rádio/efeitos adversos
5.
Sensors (Basel) ; 23(19)2023 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-37836914

RESUMO

This study investigates wireless power transfer for deep in-body receivers, determining the optimal frequency, power budget, and design for the transmitter and receiver. In particular, the focus is on small, in-body receivers at large depths up to 20 cm for obese patients. This enables long-term monitoring of the gastrointestinal tract for all body types. Numerical simulations are used to investigate power transfer and losses as a function of frequency and to find the optimal design at the selected frequency for an obese body model. From all ISM-frequencies in the investigated range (1 kHz-10 GHz), the value of 13.56 MHz yields the best performance. This optimum corresponds to the transition from dominant copper losses in conductors to dominant losses in conductive tissue. At this frequency, a transmitting and receiving coil are designed consisting of 12 and 23 windings, respectively. With a power transfer efficiency of 2.70×10-5, 18 µW can be received for an input power of 0.68 W while still satisfying exposure guidelines. The power transfer is validated by measurements. For the first time, efficiency values and the power budget are reported for WPT through 20 cm of tissue to mm sized receivers. Compared to WPT at higher frequencies, as commonly used for small receivers, the proposed system is more suitable for WPT to large depths in-body and comes with the advantage that no focusing is required, which can accommodate multiple receivers and uncertainty about receiver location more easily. The received power allows long-term sensing in the gastrointestinal tract by, e.g., temperature, pressure, and pH sensors, motility sensing, or even gastric stimulation.


Assuntos
Próteses e Implantes , Tecnologia sem Fio , Humanos , Fontes de Energia Elétrica , Desenho de Equipamento , Condutividade Elétrica
6.
Sensors (Basel) ; 22(18)2022 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-36146205

RESUMO

This paper describes the exploration of the combined antenna-channel model for a horse hoof. An antenna of 25 mm × 40 mm is designed in the ISM 868 MHz band. During the characterization and design of the antenna, the dynamic and harsh environment of the horse hoof is taken into account throughout every step of the procedure because it is impossible to de-embed the antenna from its environment. The antenna and channel model are verified extensively by measurements in phantom and ex vivo. The antenna is verified to be robust against changes in the morphology of the horse's hoof up to 50%. The dynamic environment was captured by considering different soil types and air, and the design was verified to be resilient against changes herein. The antenna performs well within the targeted band, with a fractional bandwidth of 8% and a gain of -2 dBi. Furthermore, a path loss model was constructed for a typical barn environment, and the antenna reaches a range of 250 m in the studied environment based on the LoRa technology. This research is important for monitoring horse health.


Assuntos
Casco e Garras , Tecnologia sem Fio , Animais , Desenho de Equipamento , Cavalos , Imagens de Fantasmas , Solo
7.
Sensors (Basel) ; 22(5)2022 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-35270862

RESUMO

In an increasingly wireless world, spatiotemporal monitoring of the exposure to environmental radiofrequency (RF) electromagnetic fields (EMF) is crucial to appease public uncertainty and anxiety about RF-EMF. However, although the advent of smart city infrastructures allows for dense networks of distributed sensors, the costs of accurate RF sensors remain high, and dedicated RF monitoring networks remain rare. This paper describes a comprehensive study comprising the design of a low-cost RF-EMF sensor node capable of monitoring four frequency bands used by wireless telecommunications with an unparalleled temporal resolution, its application in a small-scale distributed sensor network consisting of both fixed (on building façades) and mobile sensor nodes (on postal vans), and the subsequent analysis of over a year of data between January 2019 and May 2020, during which slightly less than 10 million samples were collected. From the fixed nodes' results, the potential errors were determined that are induced when sampling at lower speeds (e.g., one sample per 15 min) and measuring for shorter periods of time (e.g., a few weeks), as well as an adequate resolution (30 min) for diurnal and weekly temporal profiles which sufficiently preserves short-term variations. Furthermore, based on the correlation between the sensors, an adequate density of 100 sensor nodes per km2 was deduced for future networks. Finally, the mobile sensor nodes were used to identify potential RF-EMF exposure hotspots in a previously unattainable area of more than 60 km2. In summary, through the analysis of a small number of RF-EMF sensor nodes (both fixed and mobile) in an urban area, this study offers invaluable insights applicable to future designs and deployments of distributed RF-EMF sensor networks.


Assuntos
Telefone Celular , Campos Eletromagnéticos , Cidades , Exposição Ambiental/análise , Ondas de Rádio
8.
Environ Health ; 20(1): 36, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33794922

RESUMO

BACKGROUND: The general population is exposed to Radio-Frequency Electromagnetic Fields (RF-EMFs) used by telecommunication networks. Previous studies developed methods to assess this exposure. These methods will be inadequate to accurately assess exposure in 5G technologies or other wireless technologies using adaptive antennas. This is due to the fact that 5G NR (new radio) base stations will focus actively on connected users, resulting in a high spatio-temporal variations in the RF-EMFs. This increases the measurement uncertainty in personal measurements of RF-EMF exposure. Furthermore, a user's exposure from base stations will be dependent on the amount of data usage, adding a new component to the auto-induced exposure, which is often omitted in current studies. GOALS: The objective of this paper is to develop a general study protocol for future personal RF-EMF exposure research adapted to 5G technologies. This protocol will include the assessment of auto-induced exposure of both a user's own devices and the networks' base stations. METHOD: This study draws from lessons learned from previous RF-EMF exposure research and current knowledge on 5G technologies, including studies simulating 5G NR base stations and measurements around 5G NR test sites. RESULTS: To account for auto-induced exposure, an activity-based approach is introduced. In survey studies, an RF-EMF sensor is fixed on the participants' mobile device(s). Based on the measured power density, GPS data and movement and proximity sensors, different activities can be clustered and the exposure during each activity is evaluated. In microenvironmental measurements, a trained researcher performs measurements in predefined microenvironments with a mobile device equipped with the RF-EMF sensor. The mobile device is programmed to repeat a sequence of data transmission scenarios (different amounts of uplink and downlink data transmissions). Based on simulations, the amount of exposure induced in the body when the user device is at a certain location relative to the body, can be evaluated. CONCLUSION: Our protocol addresses the main challenges to personal exposure measurement introduced by 5G NR. A systematic method to evaluate a user's auto-induced exposure is introduced.


Assuntos
Redes de Comunicação de Computadores , Campos Eletromagnéticos , Monitoramento Ambiental/métodos , Ondas de Rádio , Computadores de Mão , Humanos
9.
Eur J Pediatr ; 180(2): 397-405, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32780192

RESUMO

Endocarditis is a potentially life-threatening disease in children with congenital heart disease (CHD) and correct prophylaxis (EP) is of utmost importance. We conducted two surveys among pediatricians and dentists in Flanders about their knowledge of EP guidelines. The survey was completed by 910 dentists and 100 pediatricians. Sixty-five percent of the dentists did not know any guideline. They relied for information on the internet or the child's physician. 87% identified low risk treatments correctly, but only 64% identified high risk procedures correctly. Eighty-three percent asked for the presence of CHD and allergy to antibiotics. Dentists asked advice of the patient's physician, but 29% would withhold treatments in high-risk patients and 50% did not know the pediatric antibiotic dosages. Forty-seven percent of the pediatricians did not know EP guidelines and they would preferably contact the child's cardiologist. Pediatricians had difficulties with the identification of low-risk procedures and would give unnecessary antibiotics. They identified most CHD at high risk, but scored lower for the identification of lower risk CHD.Conclusion: The knowledge of Flemish dentists and pediatricians of EP guidelines is low. The knowledge about EP guidelines and the communication between dentists and pediatricians should be improved. Patients should be provided with an individual EP card. What is Known: • The knowledge of dentists and cardiologists about EP is not perfect, which has already been described. • There are several guidelines about EP, and they are not identical and sometimes confusing. What is New: • This is the first article combining large scale surveys of the knowledge and application of EP by dentists and pediatricians, allowing us to compare knowledge and gaps of knowledge and use their complementarity in order to offer tailored solutions and use patient education and partnership.


Assuntos
Antibioticoprofilaxia , Endocardite , Criança , Odontólogos , Fidelidade a Diretrizes , Humanos , Pediatras , Inquéritos e Questionários
10.
Bioelectromagnetics ; 42(7): 550-561, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34298586

RESUMO

A novel Machine Learning (ML) method based on Neural Networks (NN) is proposed to assess radio-frequency (RF) exposure generated by WiFi sources in indoor scenarios. The aim was to build an NN capable of addressing the complexity and variability of real-life exposure setups, including the effects of not only down-link transmission access points (APs) but also up-link transmission by different sources (e.g. laptop, printers, tablets, and smartphones). The NN was fed with easy to be found data, such as the position and type of WiFi sources (APs, clients, and other users) and the position and material characteristics (e.g. penetration loss) of walls. The NN model was assessed using an additional new layout, distinct from that one used to build and optimize the NN coefficients. The NN model achieved a remarkable field prediction accuracy across exposure conditions in both layouts, with a median prediction error of -0.4 to 0.6 dB and a root mean square error of 2.5-5.1 dB, compared with the target electric field estimated by a deterministic indoor network planner. The proposed approach performs well for the different layouts and is thus generally used to assess RF exposure in indoor scenarios. © 2021 The Authors. Bioelectromagnetics published by Wiley Periodicals LLC on behalf of Bioelectromagnetics Society.


Assuntos
Aprendizado de Máquina , Redes Neurais de Computação , Humanos , Ondas de Rádio
11.
Clin Oral Investig ; 25(5): 3181-3195, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33108483

RESUMO

OBJECTIVES: Tricalcium silicate (TCS)-based biomaterials induce differentiation of human dental pulp cells (hDPCs) into odontoblasts/osteoblasts, which is regulated by the interplay between various intracellular pathways and their resultant secretome. The aim of this study was to compare the transcriptome-wide effects by next-generation RNA sequencing of custom-prepared hDPCs stimulated with TCS-based biomaterials: ProRoot white MTA (WMTA) (Dentsply, Tulsa; Tulsa, OK) and Biodentine (Septodont, Saint Maur des Fosses, France). METHODS: Self-isolated hDPCs were seeded in a 6-well plate at a density of 5 × 105 cells per well. ProRoot white MTA and Biodentine were then placed in transwell inserts with a pore size of 0.4 µm and inserted in the well plate. RNA sequencing was performed after 3 and 7 days treatment. For post-validation, RT-PCR analyses were done on some of the RNA samples used for RNA sequencing. RESULTS: Our RNA sequencing results for the first time identified 7533 differentially expressed genes (DEGs) between different treatments and the number of DEGs in Biodentine was higher than ProRoot WMTA at both 3 and 7 days. Despite their differential gene expression, both the TCS-based biomaterial treatments showed gene expressions mainly involved in odontoblast differentiation, angiogenesis, neurogenesis, dentinogenesis, and tooth mineralization. CONCLUSIONS: The results of the present study illustrate that several important signalling pathways are induced by hDPCs stimulated with TCS-based biomaterials. CLINICAL RELEVANCE: The differential expression of the genes associated with odontogenesis, angiogenesis, neurogenesis, dentinogenesis, and mineralization may affect the prognosis of teeth treated with Biodentine or ProRoot white MTA.


Assuntos
Compostos de Alumínio , Transcriptoma , Compostos de Alumínio/farmacologia , Compostos de Cálcio/farmacologia , Cimentos Dentários/farmacologia , Polpa Dentária , Combinação de Medicamentos , França , Humanos , Óxidos/farmacologia , Análise de Sequência de RNA , Silicatos/farmacologia
12.
Sensors (Basel) ; 21(13)2021 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-34283101

RESUMO

We present a smartphone-based indoor localisation system, able to track pedestrians over multiple floors. The system uses Pedestrian Dead Reckoning (PDR), which exploits data from the smartphone's inertial measurement unit to estimate the trajectory. The PDR output is matched to a scaled floor plan and fused with model-based WiFi received signal strength fingerprinting by a Backtracking Particle Filter (BPF). We proposed a new Viterbi-based floor detection algorithm, which fuses data from the smartphone's accelerometer, barometer and WiFi RSS measurements to detect stairs and elevator usage and to estimate the correct floor number. We also proposed a clustering algorithm on top of the BPF to solve multimodality, a known problem with particle filters. The proposed system relies on only a few pre-existing access points, whereas most systems assume or require the presence of a dedicated localisation infrastructure. In most public buildings and offices, access points are often available at smaller densities than used for localisation. Our system was extensively tested in a real office environment with seven 41 m × 27 m floors, each of which had two WiFi access points. Our system was evaluated in real-time and batch mode, since the system was able to correct past states. The clustering algorithm reduced the median position error by 17% in real-time and 13% in batch mode, while the floor detection algorithm achieved a 99.1% and 99.7% floor number accuracy in real-time and batch mode, respectively.


Assuntos
Pedestres , Algoritmos , Elevadores e Escadas Rolantes , Humanos , Smartphone , Caminhada
13.
Environ Res ; 183: 109196, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32032814

RESUMO

This paper describes radiofrequency (RF) electromagnetic field (EMF) measurements in the vicinity of single and banks of advanced metering infrastructure (AMI) smart meters. The measurements were performed in a meter testing and distribution facility as well as in-situ at five urban locations. The measurements consisted of gauging the RF environment at the place of assessment, evaluating the worst-case electric-field levels at various positions around the assessed AMI meter configuration (spatial assessment), which ranged from a single meter to a bank of 81 m, and calculating the duty cycle of the system, i.e. the fraction of time that the AMI meters were actually transmitting (12-h temporal assessment). Both in-situ and in the meter facility, the maximum field levels at 0.3 m from the meter configurations were 10-13 V/m for a single meter and 18-38 V/m for meter banks with 20-81 m. Furthermore, 6-min average duty cycles of 0.01% (1 m) up to 13% (81-m bank) were observed. Next, two general statistical models (one for a single meter and one for a meter bank) were constructed to predict the electric-field strength as a function of distance to any configuration of the assessed AMI meters. For all scenarios, the measured exposure levels (at a minimum distance of 0.3 m) were well below the maximum permissible exposure limits issued by the International Commission on Non-Ionizing Radiation Protection (ICNIRP), the U.S. Federal Communications Commission (FCC), and the Institute of Electrical and Electronics Engineers (IEEE). Indeed, the worst-case time-average exposure level at a distance of 0.3 m from an AMI installation was 5.39% of the FCC/IEEE and 9.43% of the ICNIRP reference levels.


Assuntos
Campos Eletromagnéticos , Exposição Ambiental , Ondas de Rádio , Eletricidade , Monitoramento Ambiental , Modelos Estatísticos , Radiação Ionizante
14.
Sensors (Basel) ; 20(19)2020 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-33003578

RESUMO

Currently, visible light positioning (VLP) enabling an illumination infrastructure requires a costly retrofit. Intensity modulation systems not only necessitate changes to the internal LED driving module, but decrease the LEDs' radiant flux as well. This hinders the infrastructure's ability to meet the maintained illuminance standards. Ideally, the LEDs could be left unmodulated, i.e., unmodulated VLP (uVLP). uVLP systems, inherently low-cost, exploit the characteristics of the light signals of opportunity (LSOOP) to infer a position. In this paper, it is shown that proper signal processing allows using the LED's characteristic frequency (CF) as a discriminative feature in photodiode (PD)-based received signal strength (RSS) uVLP. This manuscript investigates and compares the aptitude of (future) RSS-based uVLP and VLP systems in terms of their feasibility, cost and accuracy. It demonstrates that CF-based uVLP exhibits an acceptable loss of accuracy compared to (regular) VLP. For point source-like LEDs, uVLP only worsens the trilateration-based median p50 and 90th percentile root-mean-square error p90 from 5.3cm to 7.9cm (+50%) and from 9.6cm to 15.6cm (+62%), in the 4m × 4m room under consideration. A large experimental validation shows that employing a robust model-based fingerprinting localisation procedure, instead of trilateration, further boosts uVLP's p50 and p90 accuracy to 5.0cm and 10.6cm. When collating with VLP's p50=3.5cm and p90=6.8cm, uVLP exhibits a comparable positioning performance at a significantly lower cost and at a higher maintained illuminance, all of which underline uVLP's high adoption potential. With this work, a significant step is taken towards the development of an accurate and low-cost tracking system.

15.
Sensors (Basel) ; 20(7)2020 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-32235403

RESUMO

This paper experimentally investigates passive human visible light sensing (VLS). A passive VLS system is tested consisting of one light emitting diode (LED) and one photodiode-based receiver, both ceiling-mounted. There is no line of sight between the LED and the receiver, so only reflected light can be considered. The influence of a human is investigated based on the received signal strength (RSS) values of the reflections of ambient light at the photodiode. Depending on the situation, this influence can reach up to ± 50 % . The experimental results show the influence of three various clothing colors, four different walking directions and four different layouts. Based on the obtained results, a human pass-by detection system is proposed and tested. The system achieves a detection rate of 100% in a controlled environment for 21 experiments. For a realistic corridor experiment, the system keeps its detection rate of 100% for 19 experiments.


Assuntos
Técnicas Biossensoriais/instrumentação , Percepção de Movimento , Movimento (Física) , Humanos , Luz
16.
Sensors (Basel) ; 20(20)2020 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-33066683

RESUMO

In contrast to accurate GPS-based localization, approaches to localize within LoRaWAN networks offer the advantages of being low power and low cost. This targets a very different set of use cases and applications on the market where accuracy is not the main considered metric. The localization is performed by the Time Difference of Arrival (TDoA) method and provides discrete position estimates on a map. An accurate "tracking-on-demand" mode for retrieving lost and stolen assets is important. To enable this mode, we propose deploying an e-compass in the mobile LoRa node, which frequently communicates directional information via the payload of the LoRaWAN uplink messages. Fusing this additional information with raw TDoA estimates in a map matching algorithm enables us to estimate the node location with a much increased accuracy. It is shown that this sensor fusion technique outperforms raw TDoA at the cost of only embedding a low-cost e-compass. For driving, cycling, and walking trajectories, we obtained minimal improvements of 65, 76, and 82% on the median errors which were reduced from 206 to 68 m, 197 to 47 m, and 175 to 31 m, respectively. The energy impact of adding an e-compass is limited: energy consumption increases by only 10% compared to traditional LoRa localization, resulting in a solution that is still 14 times more energy-efficient than a GPS-over-LoRa solution.

17.
Phys Rev Lett ; 122(10): 108101, 2019 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-30932680

RESUMO

Autonomous implantable bioelectronics requires efficient radiating structures for data transfer and wireless powering. The radiation of body-implanted capsules is investigated to obtain the explicit radiation optima for E- and B-coupled sources of arbitrary dimensions and properties. The analysis uses the conservation-of-energy formulation within dispersive homogeneous and stratified canonical body models. The results reveal that the fundamental bounds exceed by far the efficiencies currently obtained by conventional designs. Finally, a practical realization of the optimal source based on a dielectric-loaded cylindrical-patch structure is presented. The radiation efficiency of the structure closely approaches the theoretical bounds and shows a fivefold improvement over existing systems.

18.
Environ Res ; 175: 351-366, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31150934

RESUMO

Personal exposure to Radio-Frequency Electromagnetic Fields (RF-EMFs) was studied using personal measurements in five different microenvironments in each of five cities (Brussels, Antwerp, Ghent, Bruges and Hasselt) in Flanders, Belgium. These measurements were carried out by two researchers using on-body calibrated personal exposimeters. In three out of the five studied cities (Brussels, Ghent and Bruges), temporal aspects of personal exposure to RF-EMFs were studied as well. Measurements during and outside of rush hours (7:00-9:15 and 16:30-19:00) were compared. Likewise, measurements were executed during night time and compared to the ones measured during working hours. Representativeness and repeatability of the measurement method was studied as well. The highest mean total exposure was found in Brussels (2.63 mW/m2), the most densely populated city in this study. However, we measured higher downlink exposure in Antwerp than in Brussels, which might be an effect of the stronger legislation on base stations in Brussels. The measurements and used protocol were found to be both repeatable over time (r = 0.95 for median total exposure) and representative for the studied microenvironments in terms of path selection (r = 0.88 for median total exposure). Finally, in 10 out of the 13 on-body calibrated frequency bands we found that the measurement devices underestimate the intensity of the incident RF-EMFs with median underestimations up to 68%.


Assuntos
Campos Eletromagnéticos , Exposição Ambiental , Ondas de Rádio , Bélgica , Telefone Celular , Cidades
19.
Environ Res ; 175: 1-10, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31096087

RESUMO

When making phone calls, cellphone and smartphone users are exposed to radio-frequency (RF) electromagnetic fields (EMFs) and sound pressure simultaneously. Speech intelligibility during mobile phone calls is related to the sound pressure level of speech relative to potential background sounds and also to the RF-EMF exposure, since the signal quality is correlated with the RF-EMF strength. Additionally, speech intelligibility, sound pressure level, and exposure to RF-EMFs are dependent on how the call is made (on speaker, held at the ear, or with headsets). The relationship between speech intelligibility, sound exposure, and exposure to RF-EMFs is determined in this study. To this aim, the transmitted RF-EMF power was recorded during phone calls made by 53 subjects in three different, controlled exposure scenarios: calling with the phone at the ear, calling in speaker-mode, and calling with a headset. This emitted power is directly proportional to the exposure to RF EMFs and is translated into specific absorption rate using numerical simulations. Simultaneously, sound pressure levels have been recorded and speech intelligibility has been assessed during each phone call. The results show that exposure to RF-EMFs, quantified as the specific absorption in the head, will be reduced when speaker-mode or a headset is used, in comparison to calling next to the ear. Additionally, personal exposure to sound pressure is also found to be highest in the condition where the phone is held next to the ear. On the other hand, speech perception is found to be the best when calling with a phone next to the ear in comparison to the other studied conditions, when background noise is present.


Assuntos
Telefone Celular , Campos Eletromagnéticos , Ondas de Rádio , Inteligibilidade da Fala , Telefone Celular/instrumentação , Telefone Celular/normas , Humanos , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle
20.
Sensors (Basel) ; 19(15)2019 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-31366112

RESUMO

Today's wireless networks provide us reliable connectivity. However, if a disaster occurs, the whole network could be out of service and people cannot communicate. Using a fast deployable temporally network by mounting small cell base stations on unmanned aerial vehicles (UAVs) could solve the problem. Yet, this raises several challenges. We propose a capacity-deployment tool to design the backhaul network for UAV-aided networks and to evaluate the performance of the backhaul network in a realistic scenario in the city center of Ghent, Belgium. This tool assigns simultaneously resources to the ground users-access network-and to the backhaul network, taking into consideration backhaul capacity and power restrictions. We compare three types of backhaul scenarios using a 3.5 GHz link, 3.5 GHz with carrier aggregation (CA) and the 60 GHz band, considering three different types of drones. The results showed that an optimal UAV flight height (80 m) could satisfy both access and backhaul networks; however, full coverage was difficult to achieve. Finally, we discuss the influence of the flight height and the number of requesting users concerning the network performance and propose an optimal configuration and new mechanisms to improve the network capacity, based on realistic restrictions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA