Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 116
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Molecules ; 29(9)2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38731399

RESUMO

The antibacterial effects of a selection of volatile fatty acids (acetic, propionic, butyric, valeric, and caproic acids) relevant to anaerobic digestion were investigated at 1, 2 and 4 g/L. The antibacterial effects were characterised by the dynamics of Enterococcus faecalis NCTC 00775, Escherichia coli JCM 1649 and Klebsiella pneumoniae A17. Mesophilic anaerobic incubation to determine the minimum bactericidal concentration (MBC) and median lethal concentration of the VFAs was carried out in Luria Bertani broth at 37 °C for 48 h. Samples collected at times 0, 3, 6, 24 and 48 h were used to monitor bacterial kinetics and pH. VFAs at 4 g/L demonstrated the highest bactericidal effect (p < 0.05), while 1 g/L supported bacterial growth. The VFA cocktail was the most effective, while propionic acid was the least effective. Enterococcus faecalis NCTC 00775 was the most resistant strain with the VFAs MBC of 4 g/L, while Klebsiella pneumoniae A17 was the least resistant with the VFAs MBC of 2 g/L. Allowing a 48 h incubation period led to more log decline in the bacterial numbers compared to earlier times. The VFA cocktail, valeric, and caproic acids at 4 g/L achieved elimination of the three bacteria strains, with over 7 log10 decrease within 48 h.


Assuntos
Antibacterianos , Enterococcus faecalis , Ácidos Graxos Voláteis , Klebsiella pneumoniae , Testes de Sensibilidade Microbiana , Ácidos Graxos Voláteis/metabolismo , Ácidos Graxos Voláteis/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Enterococcus faecalis/efeitos dos fármacos , Enterococcus faecalis/crescimento & desenvolvimento , Klebsiella pneumoniae/efeitos dos fármacos , Klebsiella pneumoniae/crescimento & desenvolvimento , Anaerobiose , Escherichia coli/efeitos dos fármacos , Escherichia coli/crescimento & desenvolvimento , Propionatos/farmacologia , Concentração de Íons de Hidrogênio , Ácidos Pentanoicos/farmacologia
2.
Radiology ; 307(4): e230441, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37097133

RESUMO

Background Radiology is a major contributor to health care's climate footprint due to energy-intensive devices, particularly MRI, which uses the most energy. Purpose To determine the energy, cost, and carbon savings that could be achieved through different scanner power management strategies. Materials and Methods In this retrospective evaluation, four outpatient MRI scanners from three vendors were individually equipped with power meters (1-Hz sampling rate). Power measurement logs were extracted for 39 days. Data were segmented into off, idle, prepared-to-scan, scan, or power-save modes for each scanner. Energy, cost (assuming a mean cost of $0.14 per kilowatt hour), and carbon savings were calculated for the lowest scanner activity modes. Data were summarized using descriptive statistics and 95% CIs. Results Projected annual energy consumption per scanner ranged from 82.7 to 171.1 MW-hours, with 72%-91% defined as nonproductive. Power draws for each mode were measured as 6.4 kW ± 0.1 (SD; power-save mode), 7.3 kW ± 0.6 to 9.7 kW ± 0.2 (off), 9.5 kW ± 0.9 to 14.5 kW ± 0.5 (idle), 17.3 kW ± 0.5 to 25.6 kW ± 0.6 (prepared-to-scan mode), and 28.6 kW ± 8.6 to 48.3 kW ± 11.8 (scan mode). Switching MRI units from idle to off mode for 12 hours overnight reduced power consumption by 25%-33%, translating to a potential annual savings of 12.3-21.0 MW-hours, $1717-$2943, and 8.7-14.9 metric tons of carbon dioxide (CO2) equivalent (MTCO2eq). The power-save mode further reduced consumption by 22%-28% compared with off mode, potentially saving an additional 8.8-11.4 MW-hours, $1226-$1594, and 6.2-8.1 MTCO2eq per year for 12 hours overnight. Implementation of a power-save mode for 12 hours overnight in all outpatient MRI units in the United States could save U.S. health care 58 863.2-76 288.2 MW-hours, $8.2-$10.7 million, and 41 606.4-54 088.3 MTCO2eq. Conclusion Powering down MRI units made radiology departments more energy efficient and showed substantial sustainability and cost benefits. © RSNA, 2023 Supplemental material is available for this article. See also the article by Vosshenrich and Heye in this issue.


Assuntos
Pegada de Carbono , Radiologia , Estados Unidos , Humanos , Redução de Custos , Estudos Retrospectivos , Imageamento por Ressonância Magnética
3.
MAGMA ; 34(5): 659-666, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33839985

RESUMO

OBJECTIVES: To determine the intra-individual flow variation in serially acquired studies, and the influence of this variation on subsequent hemodynamic simulations using the inlet flow as a boundary condition. Author: Kindly check and confirm whether the corresponding authors are correctly identified.Confirmed. MATERIALS AND METHODS: This prospective study included 51 patients (37 females and 14 males) with unruptured intracranial aneurysms who have received more than three times follow-up of 2D phase-contrast MR. The flow and velocity parameters were extracted to calculate the reproducibility and variation. Patient-specific computational fluid dynamics simulations were performed using the measured flows. RESULTS: Intraclass correlation coefficients for mean and maximum velocity and flow parameters ranged from 0.77 to 0.90. A 10% CV of mean flow was identified. Variations of 10% in inlet flow resulted in hemodynamic changes including 41.41% of peak systolic wall shear stress; 39.13% of end-diastolic wall shear stress; 2.79% of low shear area at peak systole; 2.12% of low shear area at end diastole: 47.57% of time-averaged wall shear stress; and 0.17% of oscillatory shear index. CONCLUSION: This study identified 10% of intra-individual mean flow variation on phase-contrast MR. Intra-individual flow variation resulted in a non-negligible variation in wall shear stress, but relatively small variation in low shear area in hemodynamic calculations.


Assuntos
Hemodinâmica , Aneurisma Intracraniano , Feminino , Humanos , Hidrodinâmica , Aneurisma Intracraniano/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Modelos Cardiovasculares , Estudos Prospectivos , Reprodutibilidade dos Testes , Estresse Mecânico
4.
Radiology ; 296(2): 250-262, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32573388

RESUMO

MRI is a valuable clinical and research tool for patients undergoing deep brain stimulation (DBS). However, risks associated with imaging DBS devices have led to stringent regulations, limiting the clinical and research utility of MRI in these patients. The main risks in patients with DBS devices undergoing MRI are heating at the electrode tips, induced currents, implantable pulse generator dysfunction, and mechanical forces. Phantom model studies indicate that electrode tip heating remains the most serious risk for modern DBS devices. The absence of adverse events in patients imaged under DBS vendor guidelines for MRI demonstrates the general safety of MRI for patients with DBS devices. Moreover, recent work indicates that-given adequate safety data-patients may be imaged outside these guidelines. At present, investigators are primarily focused on improving DBS device and MRI safety through the development of tools, including safety simulation models. Existing guidelines provide a standardized framework for performing safe MRI in patients with DBS devices. It also highlights the possibility of expanding MRI as a tool for research and clinical care in these patients going forward.


Assuntos
Encéfalo/diagnóstico por imagem , Estimulação Encefálica Profunda/instrumentação , Imageamento por Ressonância Magnética , Segurança do Paciente/normas , Simulação por Computador , Temperatura Alta/efeitos adversos , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/normas , Próteses Neurais/efeitos adversos , Imagens de Fantasmas
5.
Ann Neurol ; 85(5): 704-714, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30802998

RESUMO

OBJECTIVE: To understand the safety, putaminal coverage, and enzyme expression of adeno-associated viral vector serotype-2 encoding the complementary DNA for the enzyme, aromatic L-amino acid decarboxylase (VY-AADC01), delivered using novel intraoperative monitoring to optimize delivery. METHODS: Fifteen subjects (three cohorts of 5) with moderately advanced Parkinson's disease and medically refractory motor fluctuations received VY-AADC01 bilaterally coadministered with gadoteridol to the putamen using intraoperative magnetic resonance imaging (MRI) guidance to visualize the anatomic spread of the infusate and calculate coverage. Cohort 1 received 8.3 × 1011 vg/ml and ≤450 µl per putamen (total dose, ≤7.5 × 1011 vg); cohort 2 received the same concentration (8.3 × 1011 vg/ml) and ≤900 µl per putamen (total dose, ≤1.5 × 1012 vg); and cohort 3 received 2.6 × 1012 vg/ml and ≤900 µl per putamen (total dose, ≤4.7 × 1012 vg). (18)F-fluoro-L-dihydroxyphenylalanine positron emission tomography (PET) at baseline and 6 months postprocedure assessed enzyme activity; standard assessments measured clinical outcomes. RESULTS: MRI-guided administration of ascending VY-AADC01 doses resulted in putaminal coverage of 21% (cohort 1), 34% (cohort 2), and 42% (cohort 3). Cohorts 1, 2, and 3 showed corresponding increases in enzyme activity assessed by PET of 13%, 56%, and 79%, and reductions in antiparkinsonian medication of -15%, -33%, and -42%, respectively, at 6 months. At 12 months, there were dose-related improvements in clinical outcomes, including increases in patient-reported ON-time without troublesome dyskinesia (1.6, 3.3, and 1.5 hours, respectively) and quality of life. INTERPRETATION: Novel intraoperative monitoring of administration facilitated targeted delivery of VY-AADC01 in this phase 1 study, which was well tolerated. Increases in enzyme expression and clinical improvements were dose dependent. ClinicalTrials.gov Identifier: NCT01973543 Ann Neurol 2019;85:704-714.


Assuntos
Descarboxilases de Aminoácido-L-Aromático/genética , Terapia Genética/métodos , Imageamento por Ressonância Magnética/métodos , Doença de Parkinson/diagnóstico por imagem , Doença de Parkinson/genética , Putamen/diagnóstico por imagem , Adulto , Idoso , Descarboxilases de Aminoácido-L-Aromático/administração & dosagem , Feminino , Técnicas de Transferência de Genes , Humanos , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/terapia
6.
Neuroimage ; 184: 566-576, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-30243973

RESUMO

Access to MRI is limited for patients with deep brain stimulation (DBS) implants due to safety hazards, including radiofrequency (RF) heating of tissue surrounding the leads. Computational models provide an exquisite tool to explore the multi-variate problem of RF heating and help better understand the interaction of electromagnetic fields and biological tissues. This paper presents a computational approach to assess RF-induced heating, in terms of specific absorption rate (SAR) in the tissue, around the tip of bilateral DBS leads during MRI at 64MHz/1.5 T and 127 MHz/3T. Patient-specific realistic lead models were constructed from post-operative CT images of nine patients operated for sub-thalamic nucleus DBS. Finite element method was applied to calculate the SAR at the tip of left and right DBS contact electrodes. Both transmit head coils and transmit body coils were analyzed. We found a substantial difference between the SAR and temperature rise at the tip of right and left DBS leads, with the lead contralateral to the implanted pulse generator (IPG) exhibiting up to 7 times higher SAR in simulations, and up to 10 times higher temperature rise during measurements. The orientation of incident electric field with respect to lead trajectories was explored and a metric to predict local SAR amplification was introduced. Modification of the lead trajectory was shown to substantially reduce the heating in phantom experiments using both conductive wires and commercially available DBS leads. Finally, the surgical feasibility of implementing the modified trajectories was demonstrated in a patient operated for bilateral DBS.


Assuntos
Estimulação Encefálica Profunda , Eletrodos Implantados , Temperatura Alta , Imageamento por Ressonância Magnética/efeitos adversos , Modelos Teóricos , Simulação por Computador , Estimulação Encefálica Profunda/instrumentação , Campos Eletromagnéticos , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Ondas de Rádio
8.
Stereotact Funct Neurosurg ; 96(1): 40-45, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29495014

RESUMO

BACKGROUND/AIMS: Interventional MRI (iMRI) allows real-time confirmation of electrode and microcatheter location in anesthetized patients; however, MRI-compatible pneumatic compression devices (PCD) to reduce the periprocedural venous thromboembolism (VTE) risk are not commercially available. Given the paucity of literature on VTE following iMRI surgery, better characterizing patients suffering this complication and the incidence of this event following iMRI procedures is pivotal for defining best surgical practices. We aim to investigate the incidence of postoperative VTE in iMRI procedures without the use of PCD. METHODS: Medical records and operative times of patients were retrospectively reviewed. Patient demographics and mean surgical durations were reported with statistical comparisons via ANOVA and the 2-tailed Student t test, an α of 0.05, and the Bonferroni correction. Patients experiencing postoperative VTE underwent an in-depth chart review. RESULTS: Two out of two hundred ten (0.95%) iMRI procedures resulted in postoperative VTE events. There were statistically significant differences in procedure times between unilateral electrode (157.5 ± 5.7 min), bilateral electrode (193.6 ± 2.9 min), and bilateral gene therapy procedures (467.3 ± 26.5 min). Both patients had longer-than-average operative times for their respective procedures. CONCLUSIONS: The incidence of postoperative VTE is low following iMRI procedures, even without the use of PCD during surgery.


Assuntos
Complicações Intraoperatórias/diagnóstico por imagem , Complicações Intraoperatórias/etiologia , Imagem por Ressonância Magnética Intervencionista/efeitos adversos , Técnicas Estereotáxicas/efeitos adversos , Tromboembolia Venosa/diagnóstico por imagem , Tromboembolia Venosa/etiologia , Adolescente , Adulto , Idoso , Criança , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Adulto Jovem
9.
Biomed Microdevices ; 19(4): 88, 2017 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-28948399

RESUMO

To assess the visualization and efficacy of a wireless resonant circuit (wRC) catheter system for carotid artery occlusion and embolectomy under real-time MRI guidance in vivo, and to compare MR imaging modality with x-ray for analysis of qualitative physiological measures of blood flow at baseline and after embolectomy. The wRC catheter system was constructed using a MR compatible PEEK fiber braided catheter (Penumbra, Inc, Alameda, CA) with a single insulated longitudinal copper loop soldered to a printed circuit board embedded within the catheter wall. In concordance with IACUC protocol (AN103047), in vivo carotid artery navigation and embolectomy were performed in four farm pigs (40-45 kg) under real-time MRI at 1.5T. Industry standard clots were introduced in incremental amounts until adequate arterial occlusion was noted in a total of n=13 arteries. Baseline vasculature and restoration of blood flow were confirmed via MR and x-ray imaging, and graded by the Thrombolysis in Cerebral Infarction (TICI) scale. Wilcoxon signed-rank tests were used to analyze differences in recanalization status between DSA and MRA imaging. Successful recanalizations (TICI 2b/3) were compared to clinical rates reported in literature via binomial tests. The wRC catheter system was visible both on 5° sagittal bSSFP and coronal GRE sequence. Successful recanalization was demonstrated in 11 of 13 occluded arteries by DSA analysis and 8 of 13 by MRA. Recanalization rates based on DSA (0.85) and MRA (0.62) were not significantly different from the clinical rate of mechanical aspiration thrombectomy reported in literature. Lastly, a Wilcoxon signed rank test indicated no significant difference between TICI scores analyzed by DSA and MRA. With demonstrated compatibility and visualization under MRI, the wRC catheter system is effective for in vivo endovascular embolectomy, suggesting progress towards clinical endovascular interventional MRI.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Cateterismo , Catéteres , Embolectomia , Imageamento por Ressonância Magnética , Animais , Cateterismo/instrumentação , Cateterismo/métodos , Embolectomia/instrumentação , Embolectomia/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Suínos
10.
Stereotact Funct Neurosurg ; 95(5): 307-314, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28889128

RESUMO

BACKGROUND/AIMS: Intraoperative magnetic resonance imaging (iMRI) is increasingly used to implant deep brain stimulator (DBS) electrodes. The approach has the advantages of a high targeting accuracy, minimization of brain penetrations, and allowance of implantation under general anesthesia. The hemorrhagic complications of iMRI-guided DBS implantation have not been studied in a large series. We report on the incidence and characteristics of hemorrhage during these procedures. METHODS: Hemorrhage incidence was assessed in a series of 231 iMRI procedures (374 electrodes implanted). All patients had movement disorders and the subthalamic nucleus or the globus pallidus internus was typically targeted. Hemorrhage was detected with intra- or postoperative MRI or postoperative computed tomography. Hemorrhage was classified based on its point of origin and clinical impact. RESULTS: Hemorrhage and symptomatic hemorrhage were detected during 2.4 and 1.1% of electrode implantations, respectively. The hemorrhage origin was subdural/subarachnoid (n = 3), subcortical (n = 5), or deep (n = 1). Factors that contributed to hemorrhage included unintentional crossing of a sulcus and resistance at the pial membrane, which produced cortical depression and a rebound hemorrhage. Delayed hemorrhage occurred in 2 patients and was attributed to premature reintroduction of anticoagulation therapy or air intrusion into the cranial cavity. CONCLUSIONS: Hemorrhage was readily apparent on intraoperative imaging, and hemorrhage rates for iMRI-guided DBS implantations were comparable to those for conventional implantation approaches.


Assuntos
Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/epidemiologia , Estimulação Encefálica Profunda/efeitos adversos , Imageamento por Ressonância Magnética/efeitos adversos , Adulto , Idoso , Estimulação Encefálica Profunda/métodos , Eletrodos Implantados/efeitos adversos , Feminino , Humanos , Incidência , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Transtornos dos Movimentos/diagnóstico por imagem , Transtornos dos Movimentos/epidemiologia , Transtornos dos Movimentos/terapia , Tomografia Computadorizada por Raios X
11.
Radiology ; 281(1): 219-28, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27019290

RESUMO

Purpose To assess the feasibility of a magnetically assisted remote-controlled (MARC) catheter system under magnetic resonance (MR) imaging guidance for performing a simple endovascular procedure (ie, renal artery embolization) in vivo and to compare with x-ray guidance to determine the value of MR imaging guidance and the specific areas where the MARC system can be improved. Materials and Methods In concordance with the Institutional Animal Care and Use Committee protocol, in vivo renal artery navigation and embolization were tested in three farm pigs (mean weight 43 kg ± 2 [standard deviation]) under real-time MR imaging at 1.5 T. The MARC catheter device was constructed by using an intramural copper-braided catheter connected to a laser-lithographed saddle coil at the distal tip. Interventionalists controlled an in-room cart that delivered electrical current to deflect the catheter in the MR imager. Contralateral kidneys were similarly embolized under x-ray guidance by using standard clinical catheters and guidewires. Changes in renal artery flow and perfusion were measured before and after embolization by using velocity-encoded and perfusion MR imaging. Catheter navigation times, renal parenchymal perfusion, and renal artery flow rates were measured for MR-guided and x-ray-guided embolization procedures and are presented as means ± standard deviation in this pilot study. Results Embolization was successful in all six kidneys under both x-ray and MR imaging guidance. Mean catheterization time with MR guidance was 93 seconds ± 56, compared with 60 seconds ± 22 for x-ray guidance. Mean changes in perfusion rates were 4.9 au/sec ± 0.8 versus 4.6 au/sec ± 0.6, and mean changes in renal flow rate were 2.1 mL/min/g ± 0.2 versus 1.9 mL/min/g ± 0.2 with MR imaging and x-ray guidance, respectively. Conclusion The MARC catheter system is feasible for renal artery catheterization and embolization under real-time MR imaging in vivo, and quantitative physiologic measures under MR imaging guidance were similar to those measured under x-ray guidance, suggesting that the MARC catheter system could be used for endovascular procedures with interventional MR imaging. (©) RSNA, 2016.


Assuntos
Cateterismo Periférico/instrumentação , Embolização Terapêutica/instrumentação , Procedimentos Endovasculares/instrumentação , Imagem por Ressonância Magnética Intervencionista , Magnetismo , Artéria Renal , Animais , Modelos Animais , Projetos Piloto , Radiografia Intervencionista , Suínos
12.
Mol Ther ; 23(1): 119-29, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25138755

RESUMO

Intracerebral cell transplantation is being pursued as a treatment for many neurological diseases, and effective cell delivery is critical for clinical success. To facilitate intracerebral cell transplantation at the scale and complexity of the human brain, we developed a platform technology that enables radially branched deployment (RBD) of cells to multiple target locations at variable radial distances and depths along the initial brain penetration tract with real-time interventional magnetic resonance image (iMRI) guidance. iMRI-guided RBD functioned as an "add-on" to standard neurosurgical and imaging workflows, and procedures were performed in a commonly available clinical MRI scanner. Multiple deposits of super paramagnetic iron oxide beads were safely delivered to the striatum of live swine, and distribution to the entire putamen was achieved via a single cannula insertion in human cadaveric heads. Human embryonic stem cell-derived dopaminergic neurons were biocompatible with the iMRI-guided RBD platform and successfully delivered with iMRI guidance into the swine striatum. Thus, iMRI-guided RBD overcomes some of the technical limitations inherent to the use of straight cannulas and standard stereotactic targeting. This platform technology could have a major impact on the clinical translation of a wide range of cell therapeutics for the treatment of many neurological diseases.


Assuntos
Transplante de Células , Imagem por Ressonância Magnética Intervencionista/métodos , Técnicas Estereotáxicas/instrumentação , Animais , Cadáver , Cateterismo , Corpo Estriado/cirurgia , Feminino , Humanos , Imagem por Ressonância Magnética Intervencionista/instrumentação , Putamen/cirurgia , Suínos
13.
Stereotact Funct Neurosurg ; 94(2): 102-7, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27093443

RESUMO

BACKGROUND: Interventional magnetic resonance imaging (iMRI) allows deep brain stimulator lead placement under general anesthesia. While the accuracy of lead targeting has been described for iMRI systems utilizing 1.5-tesla magnets, a similar assessment of 3-tesla iMRI procedures has not been performed. OBJECTIVE: To compare targeting accuracy, the number of lead targeting attempts, and surgical duration between procedures performed on 1.5- and 3-tesla iMRI systems. METHODS: Radial targeting error, the number of targeting attempts, and procedure duration were compared between surgeries performed on 1.5- and 3-tesla iMRI systems (SmartFrame and ClearPoint systems). RESULTS: During the first year of operation of each system, 26 consecutive leads were implanted using the 1.5-tesla system, and 23 consecutive leads were implanted using the 3-tesla system. There was no significant difference in radial error (Mann-Whitney test, p = 0.26), number of lead placements that required multiple targeting attempts (Fisher's exact test, p = 0.59), or bilateral procedure durations between surgeries performed with the two systems (p = 0.15). CONCLUSIONS: Accurate DBS lead targeting can be achieved with iMRI systems utilizing either 1.5- or 3-tesla magnets. The use of a 3-tesla magnet, however, offers improved visualization of the target structures and allows comparable accuracy and efficiency of placement at the selected targets.


Assuntos
Estimulação Encefálica Profunda/normas , Distonia/cirurgia , Monitorização Neurofisiológica Intraoperatória/normas , Imagem por Ressonância Magnética Intervencionista/normas , Duração da Cirurgia , Doença de Parkinson/cirurgia , Adulto , Estimulação Encefálica Profunda/métodos , Distonia/diagnóstico por imagem , Feminino , Humanos , Monitorização Neurofisiológica Intraoperatória/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Masculino , Doença de Parkinson/diagnóstico por imagem , Fatores de Tempo
14.
Radiology ; 277(3): 842-52, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26030659

RESUMO

PURPOSE: To assess the feasibility of multiplanar vascular navigation with a new magnetically assisted remote-controlled (MARC) catheter with real-time magnetic resonance (MR) imaging at 1.5 T and 3 T and to compare it with standard x-ray guidance in simulated endovascular catheterization procedures. MATERIALS AND METHODS: A 1.6-mm-diameter custom clinical-grade microcatheter prototype with lithographed double-saddle coils at the distal tip was deflected with real-time MR imaging. Two inexperienced operators and two experienced operators catheterized anteroposterior (celiac, superior mesenteric, and inferior mesenteric arteries) and mediolateral (renal arteries) branch vessels in a cryogel abdominal aortic phantom. This was repeated with conventional x-ray fluoroscopy by using clinical catheters and guidewires. Mean procedure times and percentage success data were analyzed with linear mixed-effects regression. RESULTS: The MARC catheter tip was visible at 1.5 T and 3 T. Among inexperienced operators, MARC MR imaging guidance was not statistically different from x-ray guidance at 1.5 T (67% successful vessel selection turns with MR imaging vs 76% with x-ray guidance, P = .157) and at 3 T (75% successful turns with MR imaging vs 76% with x-ray guidance, P = .869). Experienced operators were more successful in catheterizing vessels with x-ray guidance (98% success within 60 seconds) than with 1.5-T (65%, P < .001) or 3-T (75%) MR imaging. Among inexperienced operators, mean procedure time was nearly equivalent by using MR imaging (31 seconds) and x-ray guidance (34 seconds, P = .436). Among experienced operators, catheterization was faster with x-ray guidance (20 seconds) compared with 1.5-T MR imaging (42 seconds, P < .001), but MARC guidance improved at 3 T (31 seconds). MARC MR imaging guidance at 3 T was not significantly different from x-ray guidance for the celiac (P = .755), superior mesenteric (P = .358), and inferior mesenteric (P = .065) arteries. CONCLUSION: Multiplanar navigation with a new MARC catheter with real-time MR imaging at 1.5 T and 3 T is feasible and comparable to x-ray guidance for anteroposterior vessels at 3 T in a vascular phantom.


Assuntos
Cateterismo Periférico/instrumentação , Imagem por Ressonância Magnética Intervencionista/instrumentação , Imagem por Ressonância Magnética Intervencionista/métodos , Cateterismo Periférico/métodos , Difusão , Estudos de Viabilidade , Fluoroscopia , Humanos , Magnetismo , Perfusão , Imagens de Fantasmas
15.
J Magn Reson Imaging ; 41(4): 1157-62, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24797218

RESUMO

PURPOSE: To develop a high temporal resolution MR imaging technique that could be used with magnetically assisted remote control (MARC) endovascular catheters. MATERIALS AND METHODS: A technique is proposed based on selective intra-arterial injections of dilute MR contrast at the beginning of a fluoroscopic MR angiography acquisition. The initial bolus of contrast is used to establish a vascular roadmap upon which MARC catheters can be tracked. The contrast to noise ratio (CNR) of the achieved roadmap was assessed in phantoms and in a swine animal model. The ability of the technique to permit navigation of activated MARC catheters through arterial branch points was evaluated. RESULTS: The roadmapping mode proved effective in phantoms for tracking objects and achieved a CNR of 35.7 between the intra- and extra-vascular space. In vivo, the intra-arterial enhancement strategy produced roadmaps with a CNR of 42.0. The artifact produced by MARC catheter activation provided signal enhancement patterns on the roadmap that experienced interventionalists could track through vascular structures. CONCLUSION: A roadmapping approach with intra-arterial contrast-enhanced MR angiography is introduced for navigating the MARC catheter. The technique mitigates the artifact produced by the MARC catheter, greatly limits the required specific absorption rate, permits regular roadmap updates due to the low contrast agent requirements, and proved effective in the in vivo setting. Inc.


Assuntos
Angiografia Digital/instrumentação , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/patologia , Cateterismo Periférico/instrumentação , Angiografia por Ressonância Magnética/instrumentação , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Imagem por Ressonância Magnética Intervencionista/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos
16.
J Biomech Eng ; 137(8): 081009, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25994000

RESUMO

Heart failure is increasing at an alarming rate, making it a worldwide epidemic. As the population ages and life expectancy increases, this trend is not likely to change. Myocardial infarction (MI)-induced adverse left ventricular (LV) remodeling is responsible for nearly 70% of heart failure cases. The adverse remodeling process involves an extension of the border zone (BZ) adjacent to an MI, which is normally perfused but shows myofiber contractile dysfunction. To improve patient-specific modeling of cardiac mechanics, we sought to create a finite element model of the human LV with BZ and MI morphologies integrated directly from delayed-enhancement magnetic resonance (DE-MR) images. Instead of separating the LV into discrete regions (e.g., the MI, BZ, and remote regions) with each having a homogeneous myocardial material property, we assumed a functional relation between the DE-MR image pixel intensity and myocardial stiffness and contractility--we considered a linear variation of material properties as a function of DE-MR image pixel intensity, which is known to improve the accuracy of the model's response. The finite element model was then calibrated using measurements obtained from the same patient--namely, 3D strain measurements-using complementary spatial modulation of magnetization magnetic resonance (CSPAMM-MR) images. This led to an average circumferential strain error of 8.9% across all American Heart Association (AHA) segments. We demonstrate the utility of our method for quantifying smooth regional variations in myocardial contractility using cardiac DE-MR and CSPAMM-MR images acquired from a 78-yr-old woman who experienced an MI approximately 1 yr prior. We found a remote myocardial diastolic stiffness of C(0) = 0.102 kPa, and a remote myocardial contractility of T(max) = 146.9 kPa, which are both in the range of previously published normal human values. Moreover, we found a normalized pixel intensity range of 30% for the BZ, which is consistent with the literature. Based on these regional myocardial material properties, we used our finite element model to compute patient-specific diastolic and systolic LV myofiber stress distributions, which cannot be measured directly. One of the main driving forces for adverse LV remodeling is assumed to be an abnormally high level of ventricular wall stress, and many existing and new treatments for heart failure fundamentally attempt to normalize LV wall stress. Thus, our noninvasive method for estimating smooth regional variations in myocardial contractility should be valuable for optimizing new surgical or medical strategies to limit the chronic evolution from infarction to heart failure.


Assuntos
Imageamento por Ressonância Magnética , Contração Miocárdica , Infarto do Miocárdio/fisiopatologia , Modelagem Computacional Específica para o Paciente , Disfunção Ventricular Esquerda/fisiopatologia , Idoso , Feminino , Análise de Elementos Finitos , Humanos , Infarto do Miocárdio/diagnóstico
18.
Radiology ; 271(3): 862-9, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24533872

RESUMO

PURPOSE: To compare in vitro navigation of a magnetically assisted remote-controlled (MARC) catheter under real-time magnetic resonance (MR) imaging with manual navigation under MR imaging and standard x-ray guidance in endovascular catheterization procedures in an abdominal aortic phantom. MATERIALS AND METHODS: The 2-mm-diameter custom clinical-grade microcatheter prototype with a solenoid coil at the distal tip was deflected with a foot pedal actuator used to deliver 300 mA of positive or negative current. Investigators navigated the catheter into branch vessels in a custom cryogel abdominal aortic phantom. This was repeated under MR imaging guidance without magnetic assistance and under conventional x-ray fluoroscopy. MR experiments were performed at 1.5 T by using a balanced steady-state free precession sequence. The mean procedure times and percentage success data were determined and analyzed with a linear mixed-effects regression analysis. RESULTS: The catheter was clearly visible under real-time MR imaging. One hundred ninety-two (80%) of 240 turns were successfully completed with magnetically assisted guidance versus 144 (60%) of 240 turns with nonassisted guidance (P < .001) and 119 (74%) of 160 turns with standard x-ray guidance (P = .028). Overall mean procedure time was shorter with magnetically assisted than with nonassisted guidance under MR imaging (37 seconds ± 6 [standard error of the mean] vs 55 seconds ± 3, P < .001), and time was comparable between magnetically assisted and standard x-ray guidance (37 seconds ± 6 vs 44 seconds ± 3, P = .045). When stratified by angle of branch vessel, magnetic assistance was faster than nonassisted MR guidance at turns of 45°, 60°, and 75°. CONCLUSION: In this study, a MARC catheter for endovascular navigation under real-time MR imaging guidance was developed and tested. For catheterization of branch vessels arising at large angles, magnetically assisted catheterization was faster than manual catheterization under MR imaging guidance and was comparable to standard x-ray guidance.


Assuntos
Cateterismo/instrumentação , Procedimentos Endovasculares/instrumentação , Imagem por Ressonância Magnética Intervencionista/instrumentação , Imagens de Fantasmas , Catéteres , Desenho de Equipamento , Fluoroscopia/instrumentação , Magnetismo
19.
Biomed Microdevices ; 16(1): 97-106, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24132857

RESUMO

Magnetic resonance imaging (MRI) guided minimally invasive interventions are an emerging technology. We developed a microcatheter that utilizes micro-electromagnets manufactured on the distal tip, in combination with the magnetic field of a MRI scanner, to perform microcatheter steering during endovascular surgery. The aim of this study was to evaluate a user control system for operating, steering and monitoring this magnetically guided microcatheter. The magnetically-assisted remote control (MARC) microcatheter was magnetically steered within a phantom in the bore of a 1.5 T MRI scanner. Controls mounted in an interventional MRI suite, along with a graphical user interface at the MRI console, were developed with communication enabled via MRI compatible hardware modules. Microcatheter tip deflection measurements were performed by evaluating MRI steady-state free precession (SSFP) images and compared to models derived from magnetic moment interactions and composite beam mechanics. The magnitude and direction of microcatheter deflections were controlled with user hand, foot, and software controls. Data from two different techniques for measuring the microcatheter tip location within a 1.5 T MRI scanner showed correlation of magnetic deflections to our model (R(2): 0.88) with a region of linear response (R(2): 0.98). Image processing tools were successful in autolocating the in vivo microcatheter tip within MRI SSFP images. Our system showed good correlation to response curves and introduced low amounts of MRI noise artifact. The center of the artifact created by the energized microcatheter solenoid was a reliable marker for determining the degree of microcatheter deflection and auto-locating the in vivo microcatheter tip.


Assuntos
Artefatos , Catéteres , Procedimentos Endovasculares/métodos , Magnetismo/instrumentação , Animais , Desenho de Equipamento , Processamento de Imagem Assistida por Computador , Campos Magnéticos , Imagem por Ressonância Magnética Intervencionista , Modelos Animais , Modelos Teóricos , Imagens de Fantasmas , Suínos
20.
Microorganisms ; 12(3)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38543654

RESUMO

The effects of the inoculum (anaerobic digestion effluent) to substrate (simulated food waste) ratio (ISR) 4.00 to 0.25 on putative pathogens and microbial kinetics during batch mesophilic anaerobic digestion were investigated. Red fluorescent protein labelled (RFPAKN132) Escherichia coli JM105 was introduced as a marker species, and together with the indigenous Clostridium sp., Enterococcus sp., Escherichia coli, and total coliforms were used to monitor pathogen death kinetics. Quantitative polymerase chain reaction was also used to estimate the bacterial, fungal, and methanogenic gene copies. All the ISRs eliminated E. coli and other coliforms (4 log10 CFU/mL), but ISR 0.25 achieved this within the shortest time (≤2 days), while ISR 1.00 initially supported pathogen proliferation. Up to 1.5 log10 CFU/mL of Clostridium was reduced by acidogenic conditions (ISR 0.25 and 0.50), while Enterococcus species were resistant to the digestion conditions. Fungal DNA was reduced (≥5 log10 copies/mL) and was undetectable in ISRs 4.00, 2.00, and 0.50 at the end of the incubation period. This study has demonstrated that ISR influenced the pH of the digesters during batch mesophilic anaerobic digestion, and that acidic and alkaline conditions achieved by the lower (0.50 and 0.25) and higher (4.00 and 2.00) ISRs, respectively, were critical to the sanitisation of waste.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA