Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Rep Pract Oncol Radiother ; 27(5): 809-820, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36523803

RESUMO

Background: We evaluated the setup error and dose absorption of an immobilization system with a shell and wooden baseplate (SW) for lung stereotactic body radiotherapy (SBRT). Materials and methods: Setup errors in 109 patients immobilized with an SW or BodyFix system (BF) were compared. Dose attenuation rates of materials for baseplates were measured with an ion-chamber. Ionization measurements were performed from 90° to 180° gantry angle in 10° increments, with the ball water equivalent phantom placed at the center of the wood and carbon baseplates whose effects on dose distribution were compared using an electron portal imaging device. Results: The ratio for the anterior-posterior, cranial-caudal, and right-left of the cases within 3-mm registered shifts in interfractional setup error were 90.9%, 89.2%, and 97.4% for the SW, and 93.2%, 91.6%, and 98.0% for the BF, respectively. For intrafractional setup error, 98.3%, 97.4%, and 99.1% for the SW and 96.6%, 95.8%, and 98.7% for the BF were within 3-mm registered shifts, respectively. In the center position, the average (minimum/maximum) dose attenuation rates from 90° to 180° for the wooden and carbon baseplates were 0.5 (0.1/2.8)% and 1.0 (-0.1/10.1)% with 6 MV, respectively. The gamma passing rates of 2%/2 mm for the wooden and carbon baseplates were 99.7% and 98.3% (p < 0.01). Conclusions: The immobilization system with an SW is effective for lung SBRT since it is comparable to the BF in setup accuracy. Moreover, the wooden baseplate had lower radiation attenuation rates and affected the dose distribution less than the carbon baseplate.

2.
J Appl Clin Med Phys ; 22(3): 254-260, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33656261

RESUMO

PURPOSE: This study investigated the intra-fractional motion (IM) of patients immobilized using the QFix Encompass Immobilization System during HyperArc (HA) treatment. METHOD: HA treatment was performed on 89 patients immobilized using the Encompass. The IM during treatment (including megavoltage (MV) registration) was analyzed for six degrees of freedom including three axes of translation (anterior-posterior, superior-inferior (SI) and left-right (LR)) and three axes of rotation (pitch, roll, and yaw). Then, the no corrected IM (IMNC ) was retrospectively simulated (excluding MV registration) in three directions (SI, LR, and yaw). Finally, the correlation between the treatment time and the IM of the 3D vector was assessed. RESULTS: The average IM in terms of the absolute displacement were 0.3 mm (SI), 0.3 mm (LR) and 0.2° (yaw) for Stereotactic radiosurgery (SRS), and 0.3 mm (SI), 0.2 mm (LR), and 0.2° (yaw) for stereotactic radiotherapy (SRT). The absolute maximum values of IM were <1 mm along the SI and LR axes and <1° along the yaw axis. The absolute maximum displacements for IMNC were >1 mm along the SI and LR axes and >1° along the yaw axis. In the correlation between the treatment time and the IM, the r-values were -0.025 and 0.027 for SRS and SRT respectively, along the axes of translation. For the axes of rotation, the r-values were 0.012 and 0.206 for SRS and SRT, respectively. CONCLUSION: Encompass provided patient immobilization with adequate accuracy during HA treatment. The absolute maximum displacement IM was less than IMNC along the translational/rotational axes, and no statistically significant relationship between the treatment time and the IM was observed.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Neoplasias Encefálicas/radioterapia , Humanos , Imobilização , Posicionamento do Paciente , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos
3.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 75(11): 1286-1296, 2019.
Artigo em Japonês | MEDLINE | ID: mdl-31748454

RESUMO

The work of radiological technologists is changing and more complicated because of the development of medical technology and implementation of information technology (IT). Although the cases of incident and accident have been reported, they have not been comprehensively analyzed in the workflow for radiotherapy. In this study, we visualized the workflow of radiological technologists in radiotherapy and revealed the causes of incidents and accidents. The work process was visualized by drawing workflow map. The structuring of problem was performed with interpretive structural modeling (ISM) method based on graph theory by analyzing of work categorized by safety management. Our results may be able to clarify the work of radiological technologists leads to the reduction of incidents and accidents in radiation therapy.


Assuntos
Bases de Dados Factuais , Fluxo de Trabalho , Acidentes , Gestão da Segurança
4.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 72(3): 227-33, 2016 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-27000671

RESUMO

PURPOSE: The quality assurance (QA) system that simultaneously quantifies the position and duration of an (192)Ir source (dwell position and time) was developed and the performance of this system was evaluated in high-dose-rate brachytherapy. METHODS: This QA system has two functions to verify and quantify dwell position and time by using a web camera. The web camera records 30 images per second in a range from 1,425 mm to 1,505 mm. A user verifies the source position from the web camera at real time. The source position and duration were quantified with the movie using in-house software which was applied with a template-matching technique. RESULTS: This QA system allowed verification of the absolute position in real time and quantification of dwell position and time simultaneously. It was evident from the verification of the system that the mean of step size errors was 0.31±0.1 mm and that of dwell time errors 0.1±0.0 s. Absolute position errors can be determined with an accuracy of 1.0 mm at all dwell points in three step sizes and dwell time errors with an accuracy of 0.1% in more than 10.0 s of the planned time. CONCLUSION: This system is to provide quick verification and quantification of the dwell position and time with high accuracy at various dwell positions without depending on the step size.


Assuntos
Braquiterapia/instrumentação , Garantia da Qualidade dos Cuidados de Saúde/métodos , Radioterapia Guiada por Imagem/instrumentação , Braquiterapia/métodos , Imagens de Fantasmas , Dosagem Radioterapêutica , Radioterapia Guiada por Imagem/métodos
5.
In Vivo ; 38(4): 1712-1718, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38936930

RESUMO

BACKGROUND/AIM: Intensity-modulated radiation therapy can deliver a highly conformal dose to a target while minimizing the dose to the organs at risk (OARs). Delineating the contours of OARs is time-consuming, and various automatic contouring software programs have been employed to reduce the delineation time. However, some software operations are manual, and further reduction in time is possible. This study aimed to automate running atlas-based auto-segmentation (ABAS) and software operations using a scripting function, thereby reducing work time. MATERIALS AND METHODS: Dice coefficient and Hausdorff distance were used to determine geometric accuracy. The manual delineation, automatic delineation, and modification times were measured. While modifying the contours, the degree of subjective correction was rated on a four-point scale. RESULTS: The model exhibited generally good geometric accuracy. However, some OARs, such as the chiasm, optic nerve, retina, lens, and brain require improvement. The average contour delineation time was reduced from 57 to 29 min (p<0.05). The subjective revision degree results indicated that all OARs required minor modifications; only the submandibular gland, thyroid, and esophagus were rated as modified from scratch. CONCLUSION: The ABAS model and scripted automation in head and neck cancer reduced the work time and software operations. The time can be further reduced by improving contour accuracy.


Assuntos
Neoplasias de Cabeça e Pescoço , Órgãos em Risco , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Software , Humanos , Neoplasias de Cabeça e Pescoço/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Dosagem Radioterapêutica , Algoritmos , Processamento de Imagem Assistida por Computador/métodos
6.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 79(3): 252-261, 2023 Mar 20.
Artigo em Japonês | MEDLINE | ID: mdl-36709971

RESUMO

PURPOSE: The questionnaire survey investigated whether "Explainer videos about radiation therapy (RT-Video)", "Treatment of breast cancer patients by female radiation therapists (F-RTT)" and "Treating male patients while wearing underwear in pelvic radiation therapy (M-RTT)" can improve patient's satisfaction. METHODS: The RT-Video survey included questions regarding the impression of radiation therapy, improving its understanding, and anxiety reduction (102 patients received radiation therapy). Fifty-one breast cancer patients were asked whether they preferred an F-RTT treatment. Subsequently, the patients treated with F-RTT (41 patients) and M-RTT (50 patients) were surveyed about their treatment satisfaction on a five-point scale. RESULTS: RT-Video improved the understanding of radiation therapy for 86 out of 102 patients (84%). In all, 68 out of 102 patients (68%) had a negative impression of radiotherapy; among them, watching the RT-Video reduced anxiety in 63% of patients. A total of 14 out of 51 breast cancer patients (28%) preferred the F-RTT treatment. The percentage of patients who received treatment satisfaction by F-RTT and M-RTT was 95% and 84%, respectively. CONCLUSION: RT-Video, F-RTT and M-RTT treatments improved patients' satisfaction.


Assuntos
Neoplasias da Mama , Radioterapia (Especialidade) , Humanos , Masculino , Feminino , Satisfação do Paciente , Neoplasias da Mama/radioterapia
7.
In Vivo ; 36(2): 687-693, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35241523

RESUMO

BACKGROUND/AIM: The aim of this study was to evaluate the mechanical performance and the effect on dose distribution and deliverability of volumetric modulated arc therapy (VMAT) plans for prostate cancer created with the commercial knowledge-based planning (KBP) system (RapidPlan™). MATERIALS AND METHODS: Three institutions, A, B, and C were enrolled in this study. Each institution established and trained a KBP model with their own cases. CT data and structures for 45 patients at institution B were utilized to validate the dose-volume parameters (D2(%), D95(%), and D98(%) for target, and V50(%), V75(%), and V90(%) for rectum and bladder), and the following mechanical performance parameters and gamma passing rates of each KBP model: leaf sequence variability (LSV), aperture area variability (AAV), total monitor unit (MU), modulation complexity score for VMAT (MCSv), MU/control point (CP), aperture area (AA)/CP, and MU×AA/CP. RESULTS: Significant differences (p<0.01) in dosimetric parameters such as D2 and D98 for target and V50, V75, and V90 for bladder were observed among the three institutions. The means and standard deviations of MCSv were 0.31±0.03, 0.29±0.02, and 0.32±0.03, and the angles of maximum and minimum MU×AA/CP were 269° and 13°, 269° and 13°, and 273° and 153° at institutions A, B, and C, respectively. The mean gamma passing rate (1%/1 mm.) was >95% for all cases in each institution. Dose distribution and mechanical performance significantly differed between the three models. CONCLUSION: Each KBP model had different dose distributions and mechanical performance but could create an acceptable plan for deliverability regardless of mechanical performance.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
8.
J Med Phys ; 46(2): 66-72, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34566285

RESUMO

PURPOSE: To evaluate customizing a knowledge-based planning (KBP) model using dosimetric analysis for volumetric modulated arc therapy for pancreatic cancer. MATERIALS AND METHODS: The first model (M1) using 56 plans and the second model (M2) using 31 plans were created in the first 7 months of the study. The ratios of volume of both kidneys overlapping the expanded planning target volume to the total volume of both kidneys (Voverlap/Vwhole) were calculated in all cases to customize M1. Regression lines were derived from Voverlap/Vwhole and mean dose to both kidneys. The third model (M3) was created using 30 plans which data put them below the regression line. For validation, KBP was performed with the three models on 21 patients. RESULTS: V18 of the left kidney for M1 plans was 7.3% greater than for clinical plans. Dmean of the left kidney for M2 plans was 2.2% greater than for clinical plans. There was no significant difference between all kidney doses in M3 and clinical plans. Dmean of the left kidney for M2 plans was 2.2% greater than for clinical plans. Dmean to both kidneys did not differ significantly between the three models in validation plans with Voverlap/Vwhole lower than average. In plans with larger than average volumes, the Dmean of validation plans created by M3 was significantly lower for both kidneys by 1.7 and 0.9 Gy than with M1 and M2, respectively. CONCLUSIONS: Selecting plans to register in a model by analyzing dosimetry and geometry is an effective means of improving the KBP model.

9.
Phys Med ; 85: 8-14, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33940528

RESUMO

PURPOSE: To construct a deep convolutional neural network that generates virtual monochromatic images (VMIs) from single-energy computed tomography (SECT) images for improved pancreatic cancer imaging quality. MATERIALS AND METHODS: Fifty patients with pancreatic cancer underwent a dual-energy CT simulation and VMIs at 77 and 60 keV were reconstructed. A 2D deep densely connected convolutional neural network was modeled to learn the relationship between the VMIs at 77 (input) and 60 keV (ground-truth). Subsequently, VMIs were generated for 20 patients from SECT images using the trained deep learning model. RESULTS: The contrast-to-noise ratio was significantly improved (p < 0.001) in the generated VMIs (4.1 ± 1.8) compared to the SECT images (2.8 ± 1.1). The mean overall image quality (4.1 ± 0.6) and tumor enhancement (3.6 ± 0.6) in the generated VMIs assessed on a five-point scale were significantly higher (p < 0.001) than that in the SECT images (3.2 ± 0.4 and 2.8 ± 0.4 for overall image quality and tumor enhancement, respectively). CONCLUSIONS: The quality of the SECT image was significantly improved both objectively and subjectively using the proposed deep learning model for pancreatic tumors in radiotherapy.


Assuntos
Aprendizado Profundo , Neoplasias Pancreáticas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Neoplasias Pancreáticas/diagnóstico por imagem , Fenômenos Físicos , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
10.
Med Dosim ; 45(1): 85-91, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31378401

RESUMO

We assessed the effect of collimator angle on the dosimetric parameters for targets and organs at risk (OARs) for collimator-optimized HA (CO-HA) and non-CO-HA (nCO-HA) plans. The nCO-HA and CO-HA plans were retrospectively generated for 26 patients (1 to 8 brain metastases). The dosimetric parameters for planning target volume (homogeneity index [HI]; conformity index [CI]; gradient index [GI]) and for OARs were compared. The modulation complexity score for volumetric modulated arc therapy (MCSV) and monitor units (MUs) were calculated. Doses were measured using the electronic portal imaging device and compared with the expected doses. Dosimetric parameters of the HI, CI, and GI for single (n = 12) and multiple (n = 14) metastases cases were comparable (p > 0.05). For multiple metastases cases, the CO-HA plan provided lower V4Gy, V12Gy, V14Gy, V16Gy for brain tissue compared to the nCO-HA plan (p < 0.05). Doses for OARs (D0.1cc) (brainstem, chiasm, Hippocampus, lens, optic nerves, and retinas) were comparable (p > 0.05). For multiple metastases cases, the CO-HA plan resulted in less complex multileaf collimator (MLC) patterns (MCSV = 0.19 ± 0.04, p < 0.01), lower MUs (8596 ± 1390 MUs, p < 0.01), and shorter beam-on time (6.2 ± 1.0 min, p < 0.01) compared to the nCO-HA plan (0.16 ± 0.04, 9365 ± 1630, and 6.7 ± 1.2 for MCSV, MUs, and beam-on time, respectively). For both treatment approach, the equivalent gamma passing rate was obtained with the 3%/3 mm and 2%/2 mm criteria (p > 0.05). The collimator optimization in the HA planning reduced doses to brain tissues and improved the treatment efficacy.


Assuntos
Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundário , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Órgãos em Risco , Radiocirurgia/efeitos adversos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/efeitos adversos , Estudos Retrospectivos
11.
Radiat Oncol ; 13(1): 13, 2018 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-29378610

RESUMO

PURPOSE: The HyperArc VMAT (HA-VMAT) planning approach was newly developed to fulfill the demands of dose delivery for brain metastases stereotactic radiosurgery. We compared the dosimetric parameters of the HA-VMAT plan with those of the conventional VMAT (C-VMAT). MATERIAL AND METHODS: For 23 patients (1-4 brain metastases), C-VMAT and HA-VMAT plans with a prescription dose of 20-24 Gy were retrospectively generated, and dosimetric parameters for PTV (homogeneity index, HI; conformity index, CI; gradient index, GI) and brain tissue (V2Gy-V16Gy) were evaluated. Subsequently, the physical characteristics (modulation complexity score for VMAT, MCSV; Monitor unit, MU) of both treatment approaches were compared. RESULTS: HA-VMAT provided higher HI (1.41 ± 0.07 vs. 1.24 ± 0.07, p < 0.01), CI (0.93 ± 0.02 vs. 0.90 ± 0.05, p = 0.01) and lower GI (3.06 ± 0.42 vs. 3.91 ± 0.55, p < 0.01) values. Moderate-to-low dose spreads (V4Gy-V16Gy) were significantly reduced (p < 0.01) in the HA-VMAT plan over that of C-VMAT. HA-VMAT plans resulted in more complex MLC patterns (lower MCSV, p < 0.01) and higher MU (p < 0.01). CONCLUSIONS: HA-VMAT plans provided significantly higher conformity and rapid dose falloff with respect to the C-VMAT plans.


Assuntos
Neoplasias Encefálicas/radioterapia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Adulto , Idoso , Neoplasias Encefálicas/secundário , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Estudos Retrospectivos , Adulto Jovem
12.
J Med Phys ; 43(4): 230-235, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30636848

RESUMO

PURPOSE: The aim of this study is to compare the interfractional setup reproducibility of two types of patient immobilization devices for prostate cancer receiving image-guided radiation therapy (IGRT). MATERIALS AND METHODS: The MOLDCARE (MC) involves hydraulic fixation, whereas the BlueBAG (BB) and Vac-Lock (VL) involve vacuum fixation. For 72 patients, each immobilization device was individually customized during computed tomography (CT) simulation. Before the treatment, bony registration was performed using orthogonal kV images and digitally reconstructed radiographs. The shift of the treatment couch was recorded as a benchmark in the first session. In subsequent sessions, the shifts from the benchmark were measured and analyzed. Soft-tissue registration was performed weekly by cone-beam CT and CT images, and the shifts were measured and analyzed. RESULTS: In the superior-inferior and left-right directions, there were nearly no changes in the overall mean among the immobilization devices. In the anterior-posterior (AP) direction, the overall mean for the MC, BB, and VL were 0.34 ± 1.33, -0.47 ± 1.27, and -1.82 ± 1.65 mm, respectively. The mean shifts along the AP direction were approximately 1 mm more in patients immobilized on the BB and 2.5 mm more in those on the VL, compared to those on the MC, after the twentieth treatment. No significant changes were observed among the patients immobilized on those devices, respectively, in soft-tissue registration. CONCLUSION: It can be concluded that the settling of the vacuum fixation was caused by air leakage in the latter-half treatment, and the immobilization device type has no effect on the treatment-position reproducibility in IGRT.

13.
J Radiat Res ; 58(5): 685-692, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28339918

RESUMO

We investigated whether methods conventionally used to evaluate patient-specific QA in volumetric-modulated arc therapy (VMAT) for intracranial tumors detect clinically relevant dosimetric errors. VMAT plans with coplanar arcs were designed for 37 intracranial tumors. Dosimetric accuracy was validated by using a 3D array detector. Dose deviations between the measured and planned doses were evaluated by gamma analysis. In addition, modulation complexity score for VMAT (MCSv) for each plan was calculated. Three-dimensional dose distributions in patient anatomy were reconstructed using 3DVH software, and clinical deviations in dosimetric parameters between the 3DVH doses and planned doses were calculated. The gamma passing rate (GPR)/MCSv and the clinical dose deviation were evaluated using Pearson's correlation coefficient. Significant correlation (P < 0.05) between the clinical dose deviation and GPR was observed with both the 3%/3 mm and 2%/2 mm criteria in clinical target volume (D99), brain (D2), brainstem (D2) and chiasm (D2), albeit that the correlations were not 'strong' (0.38 < |r| < 0.54). The maximum dose deviations of brainstem were up to 4.9 Gy and 2.9 Gy for Dmax and D%, respectively in the case of high GPR (98.2% with 3%/3 mm criteria). Regarding MCSv, none of the evaluated organs showed a significant correlation with clinical dose deviation, and correlations were 'weak' or absent (0.01 < |r| < 0.21). The use of high GPR and MCSv values does not always detect dosimetric errors in a patient. Therefore, in-depth analysis with the DVH for patient-specific QA is considered to be preferable for guaranteeing safe dose delivery.


Assuntos
Neoplasias Encefálicas/radioterapia , Raios gama , Radioterapia de Intensidade Modulada , Relação Dose-Resposta a Droga , Humanos
14.
J Radiat Res ; 57(4): 406-11, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26983983

RESUMO

The aim of this study was to compare three strategies for intensity-modulated radiotherapy (IMRT) for 20 head-and-neck cancer patients. For simultaneous integrated boost (SIB), doses were 66 and 54 Gy in 30 fractions for PTVboost and PTVelective, respectively. Two-phase IMRT delivered 50 Gy in 25 fractions to PTVelective in the First Plan, and 20 Gy in 10 fractions to PTVboost in the Second Plan. Sequential SIB (SEQ-SIB) delivered 55 Gy and 50 Gy in 25 fractions, respectively, to PTVboost and PTVelective using SIB in the First Plan and 11 Gy in 5 fractions to PTVboost in the Second Plan. Conformity indexes (CIs) (mean ± SD) for PTVboost and PTVelective were 1.09 ± 0.05 and 1.34 ± 0.12 for SIB, 1.39 ± 0.14 and 1.80 ± 0.28 for two-phase IMRT, and 1.14 ± 0.07 and 1.60 ± 0.18 for SEQ-SIB, respectively. CI was significantly highest for two-phase IMRT. Maximum doses (Dmax) to the spinal cord were 42.1 ± 1.5 Gy for SIB, 43.9 ± 1.0 Gy for two-phase IMRT and 40.3 ± 1.8 Gy for SEQ-SIB. Brainstem Dmax were 50.1 ± 2.2 Gy for SIB, 50.5 ± 4.6 Gy for two-phase IMRT and 47.4 ± 3.6 Gy for SEQ-SIB. Spinal cord Dmax for the three techniques was significantly different, and brainstem Dmax was significantly lower for SEQ-SIB. The compromised conformity of two-phase IMRT can result in higher doses to organs at risk (OARs). Lower OAR doses in SEQ-SIB made SEQ-SIB an alternative to SIB, which applies unconventional doses per fraction.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Radioterapia de Intensidade Modulada/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Tronco Encefálico/patologia , Tronco Encefálico/efeitos da radiação , Fracionamento da Dose de Radiação , Relação Dose-Resposta a Droga , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Medula Espinal/patologia , Medula Espinal/efeitos da radiação
15.
J Radiat Res ; 57(1): 91-7, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26419645

RESUMO

The aim of the this study was to validate the use of an average intensity projection (AIP) for volumetric-modulated arc therapy for stereotactic body radiation therapy (VMAT-SBRT) planning for a moving lung tumor located near the diaphragm. VMAT-SBRT plans were created using AIPs reconstructed from 10 phases of 4DCT images that were acquired with a target phantom moving with amplitudes of 5, 10, 20 and 30 mm. To generate a 4D dose distribution, the static dose for each phase was recalculated and the doses were accumulated by using the phantom position known for each phase. For 10 patients with lung tumors, a deformable registration was used to generate 4D dose distributions. Doses to the target volume obtained from the AIP plan and the 4D plan were compared, as were the doses obtained from each plan to the organs at risk (OARs). In both phantom and clinical study, dose discrepancies for all parameters of the dose volume (D(min), D(99), D(max), D(1) and D(mean)) to the target were <3%. The discrepancies of D(max) for spinal cord, esophagus and heart were <1 Gy, and the discrepancy of V20 for lung tissue was <1%. However, for OARs with large respiratory motion, the discrepancy of the D(max) was as much as 9.6 Gy for liver and 5.7 Gy for stomach. Thus, AIP is clinically acceptable as a planning CT image for predicting 4D dose, but doses to the OARs with large respiratory motion were underestimated with the AIP approach.


Assuntos
Diafragma/efeitos da radiação , Neoplasias Pulmonares/radioterapia , Imagens de Fantasmas , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada Quadridimensional , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Dosagem Radioterapêutica , Reprodutibilidade dos Testes
16.
Chest ; 124(1): 125-32, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12853514

RESUMO

OBJECTIVES: Congenital cysts of the mediastinum are an uncommon but important diagnostic group, representing 12 to 30% of all mediastinal masses. The purpose of this study was to review our institutional experience with congenital cysts of the mediastinum, emphasizing the clinical spectrum of the disease. DESIGN: Retrospective study. OBJECTIVES: University hospital unit of general thoracic surgery. METHODS: We retrospectively reviewed the records of 105 patients with cysts of the mediastinum (50 male and 55 female patients) who comprised 13.0% of mediastinal masses over the past 50 years. RESULTS: There were 10 pediatric patients (< 15 years old) and 95 adult patients. The prevalence of cysts in the adult populations was higher than that in children (14.1% vs 7.7%, p < 0.05). There were 47 bronchogenic cysts, 30 thymic cysts, 12 pericardial cysts, 7 pleural cysts, 4 esophageal duplications, 2 meningoceles, 1 thoracic duct cyst, and 2 others. MRI has become a useful tool for providing supplemental data in combination with CT. Overall, 38 patients (36.2%) with mediastinal cysts were symptomatic, including 39.2% with bronchogenic/esophageal cysts, 40% with thymic cysts, and 15.8% with pericardial/pleural cysts. One hundred patients had complete resection of their masses, 3 patients with pericardial diverticulum received a thoracoscopic fenestration without mortality, and 2 patients refused surgery. CONCLUSION: Early recognition of these relatively rare lesions would lead to immediate and appropriate surgical intervention. Early surgical intervention is also important because definitive histologic diagnosis can only be established by means of surgical extirpation.


Assuntos
Cisto Mediastínico , Adulto , Criança , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Cisto Mediastínico/congênito , Cisto Mediastínico/diagnóstico , Cisto Mediastínico/cirurgia , Prevalência , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
17.
J Thorac Imaging ; 27(6): 372-5, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23047732

RESUMO

PURPOSE: The incidence of hiatal hernia (HH) increases with age. Vertebral fracture, kyphosis, and pulmonary emphysema are suspected as possible causes. We aimed to analyze the relationship between thoracic deformities and HH in the elderly, using a deformity index. MATERIALS AND METHODS: The study participants comprised 427 inpatients at a long-term-care hospital for the elderly in Japan. The Haller index (HI) was calculated on the transverse thoracic computerized tomography images according to the following formula: transverse diameter of the thorax/anterior-posterior diameter of the thorax. HH was diagnosed when an intrathoracic stomach was seen on the computed tomography images. RESULTS: The average HI calculated for all cases and for women--but not for men--decreased with increasing age. HH was diagnosed in 21 patients (4.9%). The incidence of HH in women was higher than in men (male vs. female = 2.0% vs. 7.4%). The mean value of HI in the HH patients (1.651 ± 0.251) was significantly lower than that in non-HH patients (2.345 ± 0.460). CONCLUSIONS: Enlargement of the anterior-posterior diameter of the thorax occurs in the elderly and is associated with the occurrence of HH.


Assuntos
Avaliação Geriátrica/métodos , Hérnia Hiatal/epidemiologia , Doenças Torácicas/epidemiologia , Tórax/anormalidades , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Avaliação Geriátrica/estatística & dados numéricos , Hérnia Hiatal/diagnóstico por imagem , Humanos , Incidência , Japão , Masculino , Pessoa de Meia-Idade , Radiografia Torácica/métodos , Distribuição por Sexo , Tomografia Computadorizada por Raios X/métodos
18.
Eur J Cardiothorac Surg ; 41(2): 329-34, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21795056

RESUMO

OBJECTIVE: Throughout the history of surgery for pectus excavatum (PE), the Nuss procedure and open repair have been performed with many modifications, with most of these procedures using a metal bar. However, the use of a metal bar has several drawbacks. Thus, we aimed to develop a procedure that did not require a metal bar. METHODS: Through our experience of 426 pediatric cases that underwent various procedures for open repair of PE at Nagoya City University, we arrived at the current procedure that we describe herein. We have evaluated this procedure by review of clinical results and deformity indices (Haller's, steepness, excavation volume, and asymmetry index). RESULTS: The latest and current procedure that supports the sternum with a bridge constructed by the 4th or 5th costal cartilages is associated with fewer complications, a lower re-operation rate, and striking improvement in the indices examined. CONCLUSIONS: Our current open-repair procedure that does not require a metal bar is recommended for correction of deformities of PE in children.


Assuntos
Tórax em Funil/cirurgia , Esterno/cirurgia , Adolescente , Adulto , Perda Sanguínea Cirúrgica , Cartilagem/cirurgia , Criança , Pré-Escolar , Feminino , Humanos , Período Intraoperatório , Tempo de Internação/estatística & dados numéricos , Masculino , Metais , Osteotomia/métodos , Dor Pós-Operatória/prevenção & controle , Complicações Pós-Operatórias , Próteses e Implantes , Reoperação/estatística & dados numéricos , Costelas/cirurgia , Índice de Gravidade de Doença , Resultado do Tratamento , Adulto Jovem
19.
Interact Cardiovasc Thorac Surg ; 13(1): 21-4, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21454313

RESUMO

In advanced stage thymomas, recurrence is not uncommon but prognostic factors in recurrent thymoma have not been determined and standardized treatment for recurrence has not yet been established. A retrospective analysis was conducted on 24 thymoma patients who underwent treatment for recurrence in our institution to determine the prognostic factors for overall survival. Recurrence of thymoma appeared 11.6-109.6 months after the primary operation (34.6±25.7 months). Pleural disseminated recurrence was common (n=21) as the primary recurrent lesions. Single or combined modality therapy was performed in 19 patients; surgical resection in 12, radiotherapy in 10, and chemotherapy in six patients. A third surgical resection was performed in two patients. There was no difference in overall survival between the groups with or without treatment nor in those with or without resection. Old age and chemotherapy were factors for poorer prognosis. Patients with one or two recurrent lesions detected on CT examinations showed better prognosis. Prognosis in thymoma patients with recurrence was reviewed in the present study. Patients with a small number of recurrent lesions showed better prognosis irrespective of the treatment.


Assuntos
Recidiva Local de Neoplasia , Neoplasias Pleurais/secundário , Timoma/secundário , Neoplasias do Timo/patologia , Adulto , Fatores Etários , Idoso , Quimioterapia Adjuvante , Feminino , Humanos , Japão , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neoplasias Pleurais/diagnóstico por imagem , Neoplasias Pleurais/mortalidade , Neoplasias Pleurais/terapia , Radioterapia Adjuvante , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Taxa de Sobrevida , Timectomia , Timoma/diagnóstico por imagem , Timoma/mortalidade , Timoma/terapia , Neoplasias do Timo/diagnóstico por imagem , Neoplasias do Timo/mortalidade , Neoplasias do Timo/terapia , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
20.
J Thorac Oncol ; 5(10 Suppl 4): S304-12, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20859124

RESUMO

INTRODUCTION: Thirty years have gone by since the Masaoka staging system of thymoma was proposed in 1981. Although the Masaoka staging system has been accepted by many surgeons and pathologists, some proposals of revision and improvements have been suggested. At this time, I reinvestigated the Masaoka staging system based on the recent follow-up study of the thymomas resected at Nagoya City University. METHODS: Using the follow-up results of 211 thymomas in Nagoya, I analyzed the following aspects: (1) evaluation of the Masaoka staging system as a prognostic factor in the Nagoya series and (2) critical assessment of the proposals of revision to the Masaoka staging system. RESULTS: (1) Univariate analysis showed that Masaoka stages were significantly prognostic for overall survival (p < 0.0001). (2) The difference of survivals between stage I and II was not significant, but progression-free survival of stage I was 100% for up to 20 years, whereas one tumor death case in stage II was found. (3) Differences of survival between the cases with and without great vessel invasion in stage III were not significant. (4) Prognosis of N tumors was yet better defined. CONCLUSION: (1) The Masaoka staging system remains a valuable prognostic factor. (2) Combination of stage I with II and separation of stage III into subgroups are not recommended. (3) At the moment, it is better to include N tumors in stage IVb.


Assuntos
Timoma/patologia , Neoplasias do Timo/patologia , Humanos , Estadiamento de Neoplasias , Prognóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA