Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Small ; 15(22): e1900455, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-31012244

RESUMO

Fluorescent nanodiamonds (fNDs) containing nitrogen vacancy (NV) centers are promising candidates for quantum sensing in biological environments. This work describes the fabrication and implementation of electrospun poly lactic-co-glycolic acid (PLGA) nanofibers embedded with fNDs for optical quantum sensing in an environment, which recapitulates the nanoscale architecture and topography of the cell niche. A protocol that produces uniformly dispersed fNDs within electrospun nanofibers is demonstrated and the resulting fibers are characterized using fluorescent microscopy and scanning electron microscopy (SEM). Optically detected magnetic resonance (ODMR) and longitudinal spin relaxometry results for fNDs and embedded fNDs are compared. A new approach for fast detection of time varying magnetic fields external to the fND embedded nanofibers is demonstrated. ODMR spectra are successfully acquired from a culture of live differentiated neural stem cells functioning as a connected neural network grown on fND embedded nanofibers. This work advances the current state of the art in quantum sensing by providing a versatile sensing platform that can be tailored to produce physiological-like cell niches to replicate biologically relevant growth environments and fast measurement protocols for the detection of co-ordinated endogenous signals from clinically relevant populations of electrically active neuronal circuits.


Assuntos
Nanodiamantes/química , Nanofibras/química , Polímeros/química , Técnicas Biossensoriais/métodos , Microscopia Eletrônica de Varredura , Microscopia de Fluorescência , Pontos Quânticos
2.
Small ; 13(33)2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28692762

RESUMO

A new approach for fluorescence imaging in optically turbid media centered on the use of nanoscale ultrasound-switchable FRET-based liposome contrast agents is reported. Liposomes containing lipophilic carbocyanine dyes as FRET pairs with emission wavelengths located in the near-infrared window are prepared. The efficacy of FRET and self-quenching for liposomes with a range of fluorophore concentrations is first calculated from measurement of the liposome emission spectra. Exposure of the liposomes to ultrasound results in changes in the detected fluorescent signal, the nature of which depends on the fluorophores used, detection wavelength, and the fluorophore concentration. Line scanning of a tube containing the contrast agents with 1 mm inner diameter buried at a depth of 1 cm in a heavily scattering tissue phantom demonstrates an improvement in image spatial resolution by a factor of 6.3 as compared with images obtained in the absence of ultrasound. Improvements are also seen in image contrast with the highest obtained being 9% for a liposome system containing FRET pairs. Overall the results obtained provide evidence of the potential the nanoscale ultrasound-switchable FRET-based liposomes studied here have for in vivo fluorescence imaging.


Assuntos
Transferência Ressonante de Energia de Fluorescência , Raios Infravermelhos , Lipossomos/química , Nanopartículas/química , Nefelometria e Turbidimetria , Imagem Óptica , Ultrassom , Corantes Fluorescentes/química , Imagens de Fantasmas , Espectrometria de Fluorescência
3.
ACS Nano ; 18(9): 7148-7160, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38383159

RESUMO

Room-temperature magnetically switchable materials play a vital role in current and upcoming quantum technologies, such as spintronics, molecular switches, and data storage devices. The increasing miniaturization of device architectures produces a need to develop analytical tools capable of precisely probing spin information at the single-particle level. In this work, we demonstrate a methodology using negatively charged nitrogen vacancies (NV-) in fluorescent nanodiamond (FND) particles to probe the magnetic switching of a spin crossover (SCO) metal-organic framework (MOF), [Fe(1,6-naphthyridine)2(Ag(CN)2)2] material (1), and a single-molecule photomagnet [X(18-crown-6)(H2O)3]Fe(CN)6·2H2O, where X = Eu and Dy (materials 2a and 2b, respectively), in response to heat, light, and electron beam exposure. We employ correlative light-electron microscopy using transmission electron microscopy (TEM) finder grids to accurately image and sense spin-spin interacting particles down to the single-particle level. We used surface-sensitive optically detected magnetic resonance (ODMR) and magnetic modulation (MM) of FND photoluminescence (PL) to sense spins to a distance of ca. 10-30 nm. We show that ODMR and MM sensing was not sensitive to the temperature-induced SCO of FeII in 1 as formation of paramagnetic FeIII through surface oxidation (detected by X-ray photoelectron spectroscopy) on heating obscured the signal of bulk SCO switching. We found that proximal FNDs could effectively sense the chemical transformations induced by the 200 keV electron beam in 1, namely, AgI → Ag0 and FeII → FeIII. However, transformations induced by the electron beam are irreversible as they substantially disrupt the structure of MOF particles. Finally, we demonstrate NV- sensing of reversible photomagnetic switching, FeIII + (18-crown-6) ⇆ FeII + (18-crown-6)+ •, triggered in 2a and 2b by 405 nm light. The photoredox process of 2a and 2b proved to be the best candidate for room-temperature single-particle magnetic switching utilizing FNDs as a sensor, which could have applications into next-generation quantum technologies.

4.
J Opt Soc Am A Opt Image Sci Vis ; 30(7): 1409-16, 2013 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24323157

RESUMO

A method that uses digital heterodyne holography reconstruction to extract scattered light modulated by a single-cycle ultrasound (US) burst is demonstrated and analyzed. An US burst is used to shift the pulsed laser frequency by a series of discrete harmonic frequencies which are then locked on a CCD. The analysis demonstrates that the unmodulated light's contribution to the detected signal can be canceled by appropriate selection of the pulse repetition frequency. It is also shown that the modulated signal can be maximized by selecting a pulse sequence which consists of a pulse followed by its inverted counterpart. The system is used to image a 12 mm thick chicken breast with 2 mm wide optically absorbing objects embedded at the midplane. Furthermore, the method can be revised to detect the nonlinear US modulated signal by locking at the second harmonic US frequency.


Assuntos
Holografia/métodos , Tomografia Óptica/métodos , Ultrassom , Processamento de Imagem Assistida por Computador , Espalhamento de Radiação , Fatores de Tempo
5.
Nanoscale Adv ; 5(23): 6423-6434, 2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-38024305

RESUMO

Spin-active nanomaterials play a vital role in current and upcoming quantum technologies, such as spintronics, data storage and computing. To advance the design and application of these materials, methods to link size, shape, structure, and chemical composition with functional magnetic properties at the nanoscale level are needed. In this work, we combine the power of two local probes, namely, Nitrogen Vacancy (NV) spin-active defects in diamond and an electron beam, within experimental platforms used in electron microscopy. Negatively charged NVs within fluorescent nanodiamond (FND) particles are used to sense the local paramagnetic environment of Rb0.5Co1.3[Fe(CN)6]·3.7H2O nanoparticles (NPs), a Prussian blue analogue (PBA), as a function of FND-PBA distance (order of 10 nm) and local PBA concentration. We demonstrate perturbation of NV spins by proximal electron spins of transition metals within NPs, as detected by changes in the photoluminescence (PL) of NVs. Workflows are reported and demonstrated that employ a Transmission Electron Microscope (TEM) finder grid to spatially correlate functional and structural features of the same unique NP studied using NV sensing, based on a combination of Optically Detected Magnetic Resonance (ODMR) and Magnetic Modulation (MM) of NV PL, within TEM imaging modalities. Significantly, spin-spin dipole interactions were detected between NVs in a single FND and paramagnetic metal centre spin fluctuations in NPs through a carbon film barrier of 13 nm thickness, evidenced by TEM tilt series imaging and Electron Energy-Loss Spectroscopy (EELS), opening new avenues to sense magnetic materials encapsulated in or between thin-layered nanostructures. The measurement strategies reported herein provide a pathway towards solid-state quantitative NV sensing with atomic-scale theoretical spatial resolution, critical to the development of quantum technologies, such as memory storage and molecular switching nanodevices.

6.
Anal Chem ; 84(7): 3155-62, 2012 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-22436054

RESUMO

Raman microspectroscopy (rms) was used to identify, image, and quantify potential molecular markers for label-free monitoring the differentiation status of live neural stem cells (NSCs) in vitro. Label-free noninvasive techniques for characterization of NCSs in vitro are needed as they can be developed for real-time monitoring of live cells. Principal component analysis (PCA) and linear discriminant analysis (LDA) models based on Raman spectra of undifferentiated NSCs and NSC-derived glial cells enabled discrimination of NSCs with 89.4% sensitivity and 96.4% specificity. The differences between Raman spectra of NSCs and glial cells indicated that the discrimination of the NSCs was based on higher concentration of nucleic acids in NSCs. Spectral images corresponding to Raman bands assigned to nucleic acids for individual NSCs and glial cells were compared with fluorescence staining of cell nuclei and cytoplasm to show that the origin of the spectral differences were related to cytoplasmic RNA. On the basis of calibration models, the concentration of the RNA was quantified and mapped in individual cells at a resolution of ~700 nm. The spectral maps revealed cytoplasmic regions with concentrations of RNA as high as 4 mg/mL for NSCs while the RNA concentration in the cytoplasm of the glial cells was below the detection limit of our instrument (~1 mg/mL). In the light of recent reports describing the importance of the RNAs in stem cell populations, we propose that the observed high concentration of cytoplasmic RNAs in NSCs compared to glial cells is related to the repressed translation of mRNAs, higher concentrations of large noncoding RNAs in the cytoplasm as well as their lower cytoplasm volume. While this study demonstrates the potential of using rms for label-free assessment of live NSCs in vitro, further studies are required to establish the exact origin of the increased contribution of the cytoplasmic RNA.


Assuntos
Diferenciação Celular , Citoplasma/metabolismo , Células-Tronco Neurais/citologia , RNA/metabolismo , Análise Espectral Raman/métodos , Animais , Sobrevivência Celular , Análise Discriminante , Camundongos , Análise Multivariada , Neuroglia/citologia , Fenótipo , Análise de Componente Principal
7.
Opt Lett ; 37(10): 1658-60, 2012 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-22627528

RESUMO

Pulse inversion acoustic imaging is useful as it allows second harmonic imaging to be obtained with short acoustic pulses. This allows high axial resolution, but removes any overlap in the frequency spectra of fundamental and harmonic. We demonstrate pulse inversion ultrasound modulated optical tomography using an optical speckle based detection method. Inverted and non-inverted acoustic pulses combined with synchronized strobed illumination are applied to an optically scattering medium. Over the acquisition time of a camera, multiple pulses are summed and at the next frame the phase of the ultrasound is shifted by π/2 and the process repeated. Combining the two frames allows a second harmonic signal to be obtained. A reduction in linewidth is observed (DC=9.26 mm, fundamental=4.02 mm, second harmonic=2.43 mm) in line scans of optically absorbing objects embedded in a scattering medium (thickness=16 mm, scattering coefficient=2.3 mm(-1), anisotropy factor=0.938).

8.
Syst Rev ; 11(1): 180, 2022 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-36042457

RESUMO

BACKGROUND: Understanding the barriers and facilitators to behaviour change by primary care practitioners (PCPs) is vital to inform the design and implementation of successful Behaviour Change Interventions (BCIs), embed evidence-based medicine into routine clinical practice, and improve quality of care and population health outcomes. METHODS: A theory-led systematic review of reviews examining barriers and facilitators to clinical behaviour change by PCPs in high-income primary care contexts using PRISMA. Embase, MEDLINE, PsychInfo, HMIC and Cochrane Library were searched. Content and framework analysis was used to map reported barriers and facilitators to the Theoretical Domains Framework (TDF) and describe emergent themes. Intervention functions and policy categories to change behaviour associated with these domains were identified using the COM-B Model and Behaviour Change Wheel (BCW). RESULTS: Four thousand three hundred eighty-eight reviews were identified. Nineteen were included. The average quality score was 7.5/11. Reviews infrequently used theory to structure their methods or interpret their findings. Barriers and facilitators most frequently identified as important were principally related to 'Knowledge', 'Environmental context and resources' and 'Social influences' TDF domains. These fall under the 'Capability' and 'Opportunity' domains of COM-B, and are linked with interventions related to education, training, restriction, environmental restructuring and enablement. From this, three key areas for policy change include guidelines, regulation and legislation. Factors least frequently identified as important were related to 'Motivation' and other psychological aspects of 'Capability' of COM-B. Based on this, BCW intervention functions of persuasion, incentivisation, coercion and modelling may be perceived as less relevant by PCPs to change behaviour. CONCLUSIONS: PCPs commonly perceive barriers and facilitators to behaviour change related to the 'Capability' and 'Opportunity' domains of COM-B. PCPs may lack insight into the role that 'Motivation' and aspects of psychological 'Capability' have in behaviour change and/or that research methods have been inadequate to capture their function. Future research should apply theory-based frameworks and appropriate design methods to explore these factors. With no 'one size fits all' intervention, these findings provide general, transferable insights into how to approach changing clinical behaviour by PCPs, based on their own views on the barriers and facilitators to behaviour change. SYSTEMATIC REVIEW REGISTRATION: A protocol was submitted to the London School of Hygiene and Tropical Medicine via the Ethics and CARE form submission on 16.4.2020, ref number 21478 (available on request). The project was not registered on PROSPERO.


Assuntos
Medicina Baseada em Evidências , Motivação , Humanos , Atenção Primária à Saúde
9.
Front Genet ; 13: 1096071, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36733939

RESUMO

N6-methyladenosine (m6A) is the most abundant internal mRNA modification and is dynamically regulated through distinct protein complexes that methylate, demethylate, and/or interpret the m6A modification. These proteins, and the m6A modification, are involved in the regulation of gene expression, RNA stability, splicing and translation. Given its role in these crucial processes, m6A has been implicated in many diseases, including in cancer development and progression. Prostate cancer (PCa) is the most commonly diagnosed non-cutaneous cancer in men and recent studies support a role for m6A in PCa. Despite this, the literature currently lacks an integrated analysis of the expression of key components of the m6A RNA methyltransferase complex, both in PCa patients and in well-established cell line models. For this reason, this study used immunohistochemistry and functional studies to investigate the mechanistic and clinical significance of the METTL3, METTL14, WTAP and CBLL1 components of the m6A methyltransferase complex in PCa specimens and cell lines. Expression of METTL3 and CBLL1, but not METTL14 and WTAP, was associated with poorer PCa patient outcomes. Expression of METTL3, METTL14, WTAP and CBLL1 was higher in PCa cells compared with non-malignant prostate cells, with the highest expression seen in castrate-sensitive, androgen-responsive PCa cells. Moreover, in PCa cell lines, expression of METTL3 and WTAP was found to be androgen-regulated. To investigate the mechanistic role(s) of the m6A methyltransferase complex in PCa cells, short hairpin RNA (shRNA)-mediated knockdown coupled with next generation sequencing was used to determine the transcriptome-wide roles of METTL3, the catalytic subunit of the m6A methyltransferase complex. Functional depletion of METTL3 resulted in upregulation of the androgen receptor (AR), together with 134 AR-regulated genes. METTL3 knockdown also resulted in altered splicing, and enrichment of cell cycle, DNA repair and metabolic pathways. Collectively, this study identified the functional and clinical significance of four essential m6A complex components in PCa patient specimens and cell lines for the first time. Further studies are now warranted to determine the potential therapeutic relevance of METTL3 inhibitors in development to treat leukaemia to benefit patients with PCa.

10.
BMC Res Notes ; 14(1): 469, 2021 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-34952633

RESUMO

OBJECTIVE: The use of benchtop metabolic profiling technology based on nuclear magnetic resonance (NMR) was evaluated in a small cohort of cats with a view to applying this as a viable and rapid metabolic tool to support clinical decision making. RESULTS: Urinary metabolites were analysed from four subjects consisting of two healthy controls and two chronic kidney disease (CKD) IRIS stage 2 cases. The study identified 15 metabolites in cats with CKD that were different from the controls. Among them were acetate, creatinine, citrate, taurine, glycine, serine and threonine. Benchtop NMR technology is capable of distinguishing between chronic kidney disease case and control samples in a pilot feline cohort based on metabolic profile. We offer perspectives on the further development of this pilot work and the potential of the technology, when combined with sample databases and computational intelligence techniques to offer a clinical decision support tool not only for cases of renal disease but other metabolic conditions in the future.


Assuntos
Metabolômica , Insuficiência Renal Crônica , Animais , Gatos , Creatinina , Espectroscopia de Ressonância Magnética , Metaboloma
11.
Dement Geriatr Cogn Dis Extra ; 10(3): 205-215, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33569076

RESUMO

BACKGROUND/AIMS: Cognitive impairment is prevalent in older inpatients but may be unrecognized. Screening to identify cognitive deficits is therefore important to optimize care. The 10-point Abbreviated Mental Test Score (AMTS) is widely used in acute hospital settings but its reliability for mild versus more severe cognitive impairment is unknown. We therefore studied the AMTS versus the 30-point Montreal Cognitive Assessment (MoCA) in older (≥75 years) inpatients. METHODS: The AMTS and MoCA were administered to consecutive hospitalized patients at ≥72 h after admission in a prospective observational study. MoCA testing time was recorded. Reliability of the AMTS for the reference standard defined as mild (MoCA <26) or moderate/severe (MoCA <18) cognitive impairment was assessed using the area under the receiver-operating curve (AUC). Sensitivity, specificity, positive and negative predictive values of low AMTS (<8) for cognitive impairment were determined. RESULTS: Among 205 patients (mean/SD age = 84.9/6.3 years, 96 (46.8%) male, 74 (36.1%) dementia/delirium), mean/SD AMTS was 7.2/2.3, and mean/SD MoCA was 16.1/6.2 with mean/SD testing time = 17.9/7.2 min. 96/205 (46.8%) had low AMTS whereas 174/185 (94%) had low MoCA: 74/185 (40.0%) had mild and 100 (54.0%) had moderate/severe impairment. Moderate/severe cognitive impairment was more prevalent in the low versus the normal AMTS group: 74/83 (90%) versus 25/102 (25%, p < 0.0001). AUC of the AMTS for mild and moderate/severe impairment were 0.86 (95% CI = 0.80-0.93) and 0.88 (0.82-0.93), respectively. Specificity of AMTS <8 for both mild and moderate/severe cognitive impairment was high (100%, 71.5-100, and 92.7%, 84.8-97.3) but sensitivity was lower (44.8%, 37.0-52.8, and 72.8%, 62.6-81.6, respectively). The negative predictive value of AMTS <8 was therefore low for mild impairment (10.9%, 5.6-18.7) but much higher for moderate/severe impairment (75.2%, 65.7-83.3). All MoCA subtests discriminated between low and normal AMTS groups (all p < 0.0001, except p = 0.002 for repetition) but deficits in delayed recall, verbal fluency and visuo-executive function were prevalent even in the normal AMTS group. CONCLUSION: The AMTS is highly specific but relatively insensitive for cognitive impairment: a quarter of those with normal AMTS had moderate/severe impairment on the MoCA with widespread deficits. The AMTS cannot therefore be used as a "rule-out" test, and more detailed cognitive assessment will be required in selected patients.

12.
ACS Sens ; 5(3): 703-710, 2020 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-31867948

RESUMO

Naturally occurring paramagnetic species (PS), such as free radicals and paramagnetic metalloproteins, play an essential role in a multitude of critical physiological processes including metabolism, cell signaling, and immune response. These highly dynamic species can also act as intrinsic biomarkers for a variety of disease states, while synthetic paramagnetic probes targeted to specific sites on biomolecules enable the study of functional information such as tissue oxygenation and redox status in living systems. The work presented herein describes a new sensing method that exploits the spin-dependent emission of photoluminescence (PL) from an ensemble of nitrogen-vacancy centers in diamond for rapid, nondestructive detection of PS in living systems. Uniquely this approach involves simple measurement protocols that assess PL contrast with and without the application of microwaves. The method is demonstrated to detect concentrations of paramagnetic salts in solution and the widely used magnetic resonance imaging contrast agent gadobutrol with a limit of detection of less than 10 attomol over a 100 µm × 100 µm field of view. Real-time monitoring of changes in the concentration of paramagnetic salts is demonstrated with image exposure times of 20 ms. Further, dynamic tracking of chemical reactions is demonstrated via the conversion of low-spin cyanide-coordinated Fe3+ to hexaaqua Fe3+ under acidic conditions. Finally, the capability to map paramagnetic species in model cells with subcellular resolution is demonstrated using lipid membranes containing gadolinium-labeled phospholipids under ambient conditions in the order of minutes. Overall, this work introduces a new sensing approach for the realization of fast, sensitive imaging of PS in a widefield format that is readily deployable in biomedical settings. Ultimately, this new approach to nitrogen vacancy-based quantum sensing paves the way toward minimally invasive real-time mapping and observation of free radicals in in vitro cellular environments.


Assuntos
Técnicas Biossensoriais , Meios de Contraste , Diamante , Ferro , Lipossomos , Fenômenos Magnéticos , Espectroscopia de Ressonância Magnética , Nitrogênio , Compostos Organometálicos , Sais
13.
Anal Chim Acta ; 1067: 11-30, 2019 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-31047142

RESUMO

The employment of spectroscopically-resolved NMR techniques as analytical probes have previously been both prohibitively expensive and logistically challenging in view of the large sizes of high-field facilities. However, with recent advances in the miniaturisation of magnetic resonance technology, low-field, cryogen-free "benchtop" NMR instruments are seeing wider use. Indeed, these miniaturised spectrometers are utilised in areas ranging from food and agricultural analyses, through to human biofluid assays and disease monitoring. Therefore, it is both intrinsically timely and important to highlight current applications of this analytical strategy, and also provide an outlook for the future, where this approach may be applied to a wider range of analytical problems, both qualitatively and quantitatively.


Assuntos
Líquidos Corporais/química , Espectroscopia de Ressonância Magnética/instrumentação , Espectroscopia de Ressonância Magnética/métodos , Animais , Doença , Medicina Legal , Humanos , Sistemas Automatizados de Assistência Junto ao Leito
14.
Sci Rep ; 8(1): 697, 2018 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-29335508

RESUMO

A label-free microscopy method for assessing the differentiation status of stem cells is presented with potential application for characterization of therapeutic stem cell populations. The microscopy system is capable of characterizing live cells based on the use of evanescent wave microscopy and quantitative phase contrast (QPC) microscopy. The capability of the microscopy system is demonstrated by studying the differentiation of live immortalised neonatal mouse neural stem cells over a 15 day time course. Metrics extracted from microscope images are assessed and images compared with results from endpoint immuno-staining studies to illustrate the system's performance. Results demonstrate the potential of the microscopy system as a valuable tool for cell biologists to readily identify the differentiation status of unlabelled live cells.


Assuntos
Diferenciação Celular , Microscopia Intravital/métodos , Microscopia/métodos , Células-Tronco Neurais/citologia , Células-Tronco Neurais/fisiologia , Animais , Biometria , Células Cultivadas , Processamento de Imagem Assistida por Computador , Camundongos
15.
Biomed Opt Express ; 9(4): 1664-1679, 2018 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-29675309

RESUMO

In vivo imaging of self-illuminating bio-and chemiluminescent reporters is used to observe the physiology of small animals. However, strong light scattering by biological tissues results in poor spatial resolution of the optical imaging, which also degrades the quantitative accuracy. To overcome this challenging problem, focused ultrasound is used to modulate the light from the reporter at the ultrasound frequency. This produces an ultrasound switchable light 'beacon' that reduces the influence of light scattering in order to improve spatial resolution. The experimental results demonstrate that apart from light modulation at the ultrasound frequency (AC signal at 3.5 MHz), ultrasound also increases the DC intensity of the reporters. This is shown to be due to a temperature rise caused by insonification that was minimized to be within acceptable mammalian tissue safety thresholds by adjusting the duty cycle of the ultrasound. Line scans of bio-and chemiluminescent objects embedded within a scattering medium were obtained using ultrasound modulated (AC) and ultrasound enhanced (DC) signals. Lateral resolution is improved by a factor of 12 and 7 respectively, as compared to conventional CCD imaging. Two chemiluminescent sources separated by ~10 mm at ~20 mm deep inside a 50 mm thick chicken breast have been successfully resolved with an average signal-to-noise ratio of approximately 8-10 dB.

16.
High Throughput ; 8(1)2018 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-30591692

RESUMO

Novel sensing technologies for liquid biopsies offer promising prospects for the early detection of metabolic conditions through omics techniques. Indeed, high-field nuclear magnetic resonance (NMR) facilities are routinely used for metabolomics investigations on a range of biofluids in order to rapidly recognise unusual metabolic patterns in patients suffering from a range of diseases. However, these techniques are restricted by the prohibitively large size and cost of such facilities, suggesting a possible role for smaller, low-field NMR instruments in biofluid analysis. Herein we describe selected biomolecule validation on a low-field benchtop NMR spectrometer (60 MHz), and present an associated protocol for the analysis of biofluids on compact NMR instruments. We successfully detect common markers of diabetic control at low-to-medium concentrations through optimised experiments, including α-glucose (≤2.8 mmol/L) and acetone (25 µmol/L), and additionally in readily accessible biofluids, particularly human urine. We present a combined protocol for the analysis of these biofluids with low-field NMR spectrometers for metabolomics applications, and offer a perspective on the future of this technique appealing to 'point-of-care' applications.

17.
Eur Cell Mater ; 14: 64-77, 2007 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-18085505

RESUMO

Tissue engineering scaffolds require a controlled pore size and structure to host tissue formation. Supercritical carbon dioxide (scCO2) processing may be used to form foamed scaffolds in which the escape of CO2 from a plasticized polymer melt generates gas bubbles that shape the developing pores. The process of forming these scaffolds involves a simultaneous change in phase in the CO2 and the polymer, resulting in rapid expansion of a surface area and changes in polymer rheological properties. Hence, the process is difficult to control with respect to the desired final pore size and structure. In this paper, we describe a detailed study of the effect of polymer chemical composition, molecular weight and processing parameters on final scaffold characteristics. The study focuses on poly(DL-lactic acid) (PDLLA) and poly(DL-lactic acid-co-glycolic acid) (PLGA) as polymer classes with potential application as controlled release scaffolds for growth factor delivery. Processing parameters under investigation were temperature (from 5 to 55 degrees C) and pressure (from 60 to 230 bar). A series of amorphous PDLLA and PLGA polymers with various molecular weights (from 13 KD to 96 KD) and/or chemical compositions (the mole percentage of glycolic acid in the polymers was 0, 15, 25, 35 and 50 respectively) were employed. The resulting scaffolds were characterised by optical microscopy, scanning electron microscopy (SEM), and micro X-ray computed tomography (microCT). This is the first detailed study on using these series polymers for scaffold formation by supercritical technique. This study has demonstrated that the pore size and structure of the supercritical PDLLA and PLGA scaffolds can be tailored by careful control of processing conditions.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Ácido Láctico/química , Ácido Poliglicólico/química , Polímeros/química , Engenharia Tecidual/métodos , Alicerces Teciduais/química , Implantes Absorvíveis , Materiais Biocompatíveis , Química Orgânica/métodos , Preparações de Ação Retardada , Sistemas de Liberação de Medicamentos/instrumentação , Regeneração Tecidual Guiada , Peptídeos e Proteínas de Sinalização Intercelular/administração & dosagem , Ácido Láctico/uso terapêutico , Teste de Materiais , Microscopia Eletrônica de Varredura , Poliésteres , Ácido Poliglicólico/uso terapêutico , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Polímeros/uso terapêutico , Porosidade , Propriedades de Superfície , Resistência à Tração , Engenharia Tecidual/instrumentação
18.
PLoS One ; 11(7): e0159742, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27467748

RESUMO

A new imaging contrast agent is reported that provides an increased fluorescent signal upon application of ultrasound (US). Liposomes containing lipids labelled with pyrene were optically excited and the excimer fluorescence emission intensity was detected in the absence and presence of an ultrasound field using an acousto-fluorescence setup. The acousto-fluorescence dynamics of liposomes containing lipids with pyrene labelled on the fatty acid tail group (PyPC) and the head group (PyPE) were compared. An increase in excimer emission intensity following exposure to US was observed for both cases studied. The increased intensity and time constants were found to be different for the PyPC and PyPE systems, and dependent on the applied US pressure and exposure time. The greatest change in fluorescence intensity (130%) and smallest rise time constant (0.33 s) are achieved through the use of PyPC labelled liposomes. The mechanism underlying the observed increase of the excimer emission intensity in PyPC labelled liposomes is proposed to arise from the "wagging" of acyl chains which involves fast response and requires lower US pressure. This is accompanied by increased lipid lateral diffusivity at higher ultrasound pressures, a mechanism that is also active in the PyPE labelled liposomes.


Assuntos
Meios de Contraste , Fluorescência , Lipossomos , Ultrassom , Acústica , Nanopartículas , Espectrometria de Fluorescência
19.
IEEE Trans Biomed Eng ; 62(9): 2135-43, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25706504

RESUMO

OBJECTIVE: A hybrid imaging technique, ultrasound-modulated luminescence tomography, that uses ultrasound to modulate diffusely propagating light has been shown to improve the spatial resolution of optical images. This paper investigates the underlying modulation mechanisms and the feasibility of applying this technique to improve spatial resolution in bioluminescence tomography. METHODS: Ultrasound-modulated bioluminescence tomography was studied numerically to identify the effects of four factors (reduced optical scattering coefficient, optical absorption coefficient, refractive index, and luciferase concentration) on the depth of light modulation. In practice, an open source finite-element method tool for simulation of diffusely propagating light, near infrared fluorescence and spectral tomography, was modified to incorporate the effects of ultrasound modulation. The signal-to-noise ratios of detected modulated bioluminescent emissions are calculated using the optical and physical properties of a mouse model. RESULTS: The modulation depth of the bioluminescent emission affected by the US induced variation of local concentration of the light emitting enzyme luciferase was at least two orders of magnitude greater than that caused by variations in the other factors. For surface radiances above approximately 10(7) photons/s/cm(2)/sr, the corresponding SNRs are detectable with the currently available detector technologies. CONCLUSION: The dominant effect in generation of ultrasound-modulated bioluminescence is ultrasound induced variation in luciferase concentration. The SNR analysis confirms the feasibility of applying ultrasound-modulated bioluminescence tomography in preclinical imaging of mice. SIGNIFICANCE: The simulation model developed suggests ultrasound-modulated bioluminescence tomography is a potential technique to improve the spatial resolution of bioluminescence tomography.


Assuntos
Tomografia Óptica/métodos , Ultrassonografia/métodos , Animais , Simulação por Computador , Análise de Elementos Finitos , Luciferases , Camundongos , Imagem Multimodal , Espectroscopia de Luz Próxima ao Infravermelho
20.
Quant Imaging Med Surg ; 5(1): 9-16, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25694948

RESUMO

BACKGROUND: Ultrasound modulated optical tomography (USMOT) is an imaging technique used to provide optical functional information inside highly scattering biological tissue. One of the challenges facing this technique is the low image contrast. METHODS: A contrast enhancement imaging technique based on the non-linear oscillation of microbubbles is demonstrated to improve image contrast. The ultrasound modulated signal was detected using a laser pulse based speckle contrast detection system. Better understanding of the effects of microbubbles on the optical signals was achieved through simultaneous measurement of the ultrasound scattered by the microbubbles. RESULTS: The length of the laser pulse was found to affect the system response of the speckle contrast method with shorter pulses suppressing the fundamental ultrasound modulated optical signal. Using this property, image contrast can be enhanced by detection of the higher harmonic ultrasound modulated optical signals due to nonlinear oscillation and destruction of the microbubbles. Experimental investigations were carried out to demonstrate a doubling in contrast by imaging a scattering phantom containing an embedded silicone tube with microbubbles flowing through it. CONCLUSIONS: The contrast enhancement in USMOT resulting from the use of ultrasound microbubbles has been demonstrated. Destruction of the microbubbles was shown to be the dominant effect leading to contrast improvement as shown by simultaneously detecting the ultrasound and speckle contrast signals. Line scans of a microbubble filled silicone tube embedded in a scattering phantom demonstrated experimentally the significant image contrast improvement that can be achieved using microbubbles and demonstrates the potential as a future clinical imaging tool.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA