Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Eur Arch Otorhinolaryngol ; 276(8): 2205-2213, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31102018

RESUMO

PURPOSE: Many bilaterally deaf adults are only able to receive one cochlear implant (CI), resulting in suboptimal listening performance, especially in challenging listening environments. Adding a contralateral routing of signal (CROS) device to a unilateral CI is one possibility to alleviate these challenges. This study examined the benefit of such a CROS device. METHODS: Thirteen adult subjects with at least 6 months of CI use, and no or limited benefit of a hearing instrument in the contralateral ear were included in the study. The perceived benefit of a CROS device in everyday listening environments was evaluated up to 1 year after initial fitting using several questionnaires. Speech intelligibility performance was determined using the French matrix sentence test in quiet and in two speech-in-noise setups and was followed for 3 months after CROS fitting. RESULTS: Subjects indicated high satisfaction with the practical usability of the CROS device and long-term device retention was high. Perceived benefits in everyday listening environments were reported. Formal speech intelligibility tests revealed statistically significant median improvements of 6.93 dB SPL (Wilcoxon Z = 2.380, p = 0.017) in quiet and up to 8.00 dB SNR (Wilcoxon Z = 2.366, p = 0.018) in noise. These benefits were accessible immediately without a need for prolonged acclimatization. CONCLUSIONS: Subjective satisfaction and device retention as well as speech intelligibility benefits in quiet and in noise prove the CROS device to be a valuable addition to a unilateral CI in cases of bilateral deafness where bilateral implantation is not an option.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Retenção da Prótese , Inteligibilidade da Fala , Idoso , Implante Coclear/efeitos adversos , Implante Coclear/métodos , Implante Coclear/psicologia , Surdez/psicologia , Surdez/reabilitação , Feminino , França , Testes Auditivos/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Localização de Som
2.
Eur Arch Otorhinolaryngol ; 274(9): 3335-3342, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28664331

RESUMO

The objectives of the study were to demonstrate the audiological and subjective benefits of the adaptive UltraZoom beamforming technology available in the Naída CI Q70 sound processor, in cochlear-implanted adults upgraded from a previous generation sound processor. Thirty-four adults aged between 21 and 89 years (mean 53 ± 19) were prospectively included. Nine subjects were unilaterally implanted, 11 bilaterally and 14 were bimodal users. The mean duration of cochlear implant use was 7 years (range 5-15 years). Subjects were tested in quiet with monosyllabic words and in noise with the adaptive French Matrix test in the best-aided conditions. The test setup contained a signal source in front of the subject and three noise sources at +/-90° and 180°. The noise was presented at a fixed level of 65 dB SPL and the level of speech signal was varied to obtain the speech reception threshold (SRT). During the upgrade visit, subjects were tested with the Harmony and with the Naída CI sound processors in omnidirectional microphone configuration. After a take-home phase of 2 months, tests were repeated with the Naída CI processor with and without UltraZoom. Subjective assessment of the sound quality in daily environments was recorded using the APHAB questionnaire. No difference in performance was observed in quiet between the two processors. The Matrix test in noise was possible in the 21 subjects with the better performance. No difference was observed between the two processors for performance in noise when using the omnidirectional microphone. At the follow-up session, the median SRT with the Naída CI processor with UltraZoom was -4 dB compared to -0.45 dB without UltraZoom. The use of UltraZoom improved the median SRT by 3.6 dB (p < 0.0001, Wilcoxon paired test). When looking at the APHAB outcome, improvement was observed for speech understanding in noisy environments (p < 0.01) and in aversive situations (p < 0.05) in the group of 21 subjects who were able to perform the Matrix test in noise and for speech understanding in noise (p < 0.05) in the group of 13 subjects with the poorest performance, who were not able to perform the Matrix test in noise. The use of UltraZoom beamforming technology, available on the new sound processor Naída CI, improves speech performance in difficult and realistic noisy conditions when the cochlear implant user needs to focus on the person speaking at the front. Using the APHAB questionnaire, a subjective benefit for listening in background noise was also observed in subjects with good performance as well as in those with poor performance. This study highlighted the importance of upgrading CI recipients to new technology and to include assessment in noise and subjective feedback evaluation as part of the process.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Neurossensorial/terapia , Ruído , Percepção da Fala , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Teste do Limiar de Recepção da Fala , Inquéritos e Questionários , Adulto Jovem
3.
Audiol Res ; 6(1): 146, 2016 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-27588162

RESUMO

A multi-center self-assessment survey was conducted to evaluate patient satisfaction with the Advanced Bionics Neptune™ waterproof sound processor used with the AquaMic™ totally submersible microphone. Subjective satisfaction with the different Neptune™ wearing options, comfort, ease of use, sound quality and use of the processor in a range of active and water related situations were assessed for 23 adults and 73 children, using an online and paper based questionnaire. Upgraded subjects compared their previous processor to the Neptune™. The Neptune™ was most popular for use in general sports and in the pool. Subjects were satisfied with the sound quality of the sound processor outside and under water and following submersion. Seventy-eight percent of subjects rated waterproofness as being very useful and 83% of the newly implanted subjects selected waterproofness as one of the reasons why they chose the Neptune™ processor. Providing a waterproof sound processor is considered by cochlear implant recipients to be useful and important and is a factor in their processor choice. Subjects reported that they were satisfied with the Neptune™ sound quality, ease of use and different wearing options.

4.
Audiol Res ; 6(2): 160, 2016 08 23.
Artigo em Inglês | MEDLINE | ID: mdl-28217275

RESUMO

The aim of this survey was to gather data from both implant recipients and professionals on the ease of use of the Naída CI Q70 (Naída CI) sound processor from Advanced Bionics and on the usefulness of the new functions and features available. A secondary objective was to investigate fitting practices with the new processor. A comprehensive user satisfaction survey was conducted in a total of 186 subjects from 24 centres. In parallel, 23 professional questionnaires were collected from 11 centres. Overall, there was high satisfaction with the Naída CI processor from adults, children, experienced and new CI users as well as from professionals. The Naída CI processor was shown as being easy to use by all ages of recipients and by professionals. The majority of experienced CI users rated the Naída CI processor as being similar or better than their previous processor in all areas surveyed. The Naída CI was recommended by the professionals for fitting in all populations. Features like UltraZoom, ZoomControl and DuoPhone would not be fitted to very young children in contrast to adults. Positive ratings were obtained for ease of use, comfort and usefulness of the new functions and features of the Naída CI sound processor. Seventy-seven percent of the experienced CI users rated the new processor as being better than their previous sound processor from a general point of view. The survey also showed that fitting practices were influenced by the age of the user.

5.
Audiol Res ; 3(1): e9, 2013 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-26557346

RESUMO

ClearVoice™ enables Advanced Bionics cochlear implant users to improve their speech understanding in difficult listening environments, without compromising performance in quiet situations. The aim of the study was to evaluate the benefits of ClearVoice in children. Children between six and fourteen years of age randomly tested two modalities of ClearVoice for one month each. The baseline program, HiRes 120™, and both ClearVoice programs were evaluated with a sentence test in quiet and noise. Parents and teachers completed a questionnaire related to everyday noisy situations. The switchover to ClearVoice was uneventful for both modalities. Adjustments to thresholds and comfort levels were required. Seven out of the nine children preferred a ClearVoice program. No impact of ClearVoice on performance in quiet was observed and both modalities of ClearVoice improved speech understanding in noise compared to the baseline program, significantly with ClearVoice high. Positive outcomes were obtained from the questionnaires and discussions with parents and children. This study showed that children benefited from using ClearVoice in their daily life. There was a clear trend towards improved speech understanding in noise with ClearVoice, without affecting performance in quiet; therefore ClearVoice can be used by children all day, without having to change programs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA