Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Circ J ; 82(9): 2292-2298, 2018 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-29962392

RESUMO

BACKGROUND: Embolism during percutaneous coronary intervention (PCI) causes microcirculation impairment. The aim of this study was to clarify the relationship between the pathological characteristics of tissue captured by distal protection device (DPD) and amount of tissue accumulated in DPD. Methods and Results: A total of 671 consecutive lesions in PCI using DPD were examined. The amount of necrotic debris, fibrous tissue, calcified particle, platelet thrombus and organized thrombus in the DPD baskets was histologically evaluated. The DPD tissue amount was assessed semi-quantitatively, and the relationship between the captured DPD tissue characteristics and tissue amount was investigated. On pathology, 40.7% of the lesions had necrotic debris, 41.4% had fibrous tissue, and 18.0% had calcified particle. The prevalence of lesions in patients with acute coronary syndrome (ACS) was 62.1%. Tissue amount score distribution was as follows: score 1 (tissue invisible), 3.9%; score 2 (tissue clinging to the basket), 52.0%; score 3 (tissue accumulated at the bottom of the basket), 38.5%; and score 4 (tissue accumulated in more than half of the basket), 5.7%. On multivariate analysis, necrotic debris and fibrous tissue were associated with greater tissue amount as well as clinical presentation of ACS. CONCLUSIONS: The presence of atherosclerotic plaque component, such as necrotic debris and fibrous tissue, might be a risk for distal embolism during PCI.


Assuntos
Dispositivos de Proteção Embólica , Embolia/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Placa Aterosclerótica/patologia , Síndrome Coronariana Aguda/complicações , Idoso , Angiografia Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Ativação Plaquetária , Estudos Retrospectivos , Fatores de Risco , Trombose/fisiopatologia
2.
Circ J ; 80(3): 650-6, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26794153

RESUMO

BACKGROUND: Drug-eluting stents (DES) have reduced late loss and target lesion revascularization through the inhibition of neointimal hyperplasia, but instead increased the risk of very late stent failure due to incomplete neointimal coverage and neoatherosclerosis. Although newer DES are more effective and safer than the first-generation DES, the difference in the condition of the stented lesions between Resolute zotarolimus-eluting stents (R-ZES) and Endeavor zotarolimus-eluting stents (E-ZES) on angioscopy has not been reported. METHODS AND RESULTS: Consecutive patients who received R-ZES (n=46) or E-ZES (n=46) for de novo lesion of native coronary artery and had 1-year follow-up angioscopy were examined. Yellow color (grade 0-3), neointimal coverage (grade 0-2), heterogeneity score (maximum-minimum neointimal coverage grade) and thrombus (presence or absence) at stented lesion were evaluated. The maximum yellow color grade (1.2±0.9 vs. 0.7±1.0, P=0.005) was higher in R-ZES than in E-ZES. The maximum (1.9±0.3 vs. 1.5±0.5, P<0.001) and minimum (1.1±0.7 vs. 0.4±0.5, P<0.001) coverage grade was higher in E-ZES than in R-ZES. The heterogeneity score was higher in R-ZES than in E-ZES (1.0±0.5 vs. 0.7±0.7, P=0.007). Prevalence of thrombus was not different between the 2 stents (6.5% vs. 2.2%, P=0.4). CONCLUSIONS: E-ZES had better neointimal coverage with less yellow plaque and lower heterogeneity score than R-ZES. The lesions with E-ZES appeared more stable than those with R-ZES. (Circ J 2016; 80: 650-656).


Assuntos
Angioscopia , Aterosclerose , Stents Farmacológicos , Neointima , Placa Aterosclerótica , Sirolimo/análogos & derivados , Idoso , Aterosclerose/etiologia , Aterosclerose/patologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Neointima/etiologia , Neointima/patologia , Placa Aterosclerótica/etiologia , Placa Aterosclerótica/patologia , Sirolimo/administração & dosagem
3.
Circ J ; 79(8): 1712-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25971526

RESUMO

BACKGROUND: Bacterial cultures of cardiovascular implantable electronic devices removed from patients without clinical infection are often positive, and the cultured bacteria are different from those at the time of clinical infection. This discrepancy has not been adequately explained. We hypothesized that the cause is bacterial contamination at operation and compared the results of bacterial cultures between patients with de novo pacemaker implantation and those with pacemaker replacement. METHODS AND RESULTS: We prospectively enrolled consecutive 100 patients who underwent cardiac pacemaker implantation (49 de novo implantations, 51 replacements). We took swab cultures from inside the generator pocket (1) immediately after the creation of new pocket or removal of old generator, (2) after connection of leads to new generator, and (3) after pocket lavage. Swab cultures were positive in 272 (45%) of 600 samples. The majority of the cultured bacteria were Propionibacterium species. No statistical difference was detected between de novo implantations and replacements in the positive ratio of swab cultures. The positive ratio was not correlated with the number of previous device replacements. CONCLUSIONS: The positive ratio of swab cultures was not different between new implantations and replacements, suggesting that a positive culture merely indicates contamination of bacteria during operation rather than colonization.


Assuntos
Desfibriladores Implantáveis/microbiologia , Contaminação de Equipamentos , Infecções por Bactérias Gram-Positivas , Marca-Passo Artificial/microbiologia , Propionibacterium , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Propionibacterium/crescimento & desenvolvimento , Propionibacterium/isolamento & purificação , Estudos Prospectivos
4.
Circ J ; 78(6): 1428-36, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24717233

RESUMO

BACKGROUND: Atherosclerosis progression is thought to be one of the mechanisms of late stent failure. Atherosclerosis progression is detected as yellow plaque formation on angioscopy. Cypher sirolimus-eluting stent has been reported to accelerate atherosclerosis progression, but the influence of Endeavor zotarolimus-eluting stent (Endeavor-ZES) or Xience everolimus-eluting stent (Xience-EES) on atherosclerosis has not been clarified. Therefore, we examined the serial changes in extent of atherosclerosis after the implantation of Endeavor-ZES or Xience-EES. METHODS AND RESULTS: Consecutive patients who received implantation of Endeavor-ZES (n=25) or Xience-EES (n=30) at de novo lesion of native coronary artery and who had successful angioscopy immediately after stent implantation (baseline) and at 1-year follow-up were included in the study. Change in the maximum yellow color grade (grade 0-3) of the stented segment from baseline to follow-up was examined and was compared between Endeavor-ZES and Xience-EES. The maximum yellow color grade decreased significantly from baseline to follow-up in Endeavor-ZES (1.6±1.1 vs. 0.4±0.8, P<0.001), but it did not change in Xience-EES (1.7±1.0 vs. 1.4±0.7, P=0.23). Although the maximum yellow color grade was not different between Endeavor-ZES and Xience-EES at baseline (P=0.72), it was significantly lower in Endeavor-ZES than in Xience-EES at follow-up (P<0.001). CONCLUSIONS: Atherosclerosis evaluated by yellow color of the plaque was significantly reduced at 1 year after Endeavor-ZES implantation, but was not changed after Xience-EES implantation.


Assuntos
Doença da Artéria Coronariana/patologia , Stents Farmacológicos , Imunossupressores , Placa Aterosclerótica/patologia , Sirolimo/análogos & derivados , Idoso , Everolimo , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade
5.
Circ J ; 78(9): 2203-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24998191

RESUMO

BACKGROUND: The slow-flow or no re-flow phenomenon has been associated with distal embolization, especially of plaque debris, and with unfavorable clinical outcomes. Therefore, we examined the association between the coronary computed tomography angiography (CCTA) findings of the target lesion and distal embolization during percutaneous coronary intervention (PCI). METHODS AND RESULTS: Consecutive patients (n=55: 18 unstable angina, 19 stable effort angina, 18 silent ischemia) who underwent PCI with a filter-type distal protection device after evaluation of the target lesion by CCTA were analyzed. CCTA examined low-attenuation plaque (LAP), positive remodeling (PR), and ring-like enhancement of the target lesion. Distal embolization of thrombus and plaque debris was evaluated by pathological examination of material collected in the filter.Any distal embolization and distal embolization of plaque debris were respectively detected in 75% and 0% of patients with LAP or PR alone, in 95% and 17% of patients with both LAP and PR, and in 100% and 27% of patients with all of LAP, PR and ring-like enhancement. The sensitivity and specificity to predict plaque debris embolization by having both findings of LAP and PR was 100% and 46%, respectively. CONCLUSIONS: The CCTA findings of the target lesion were associated with distal embolization and were very sensitive for predicting plaque debris embolization.


Assuntos
Angiografia Coronária , Embolia , Intervenção Coronária Percutânea/efeitos adversos , Complicações Pós-Operatórias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Embolia/diagnóstico por imagem , Embolia/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/cirurgia
6.
Circ J ; 77(10): 2573-7, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23782525

RESUMO

BACKGROUND: Plaque disruption and its healing is thought to be the major mechanism of atherosclerosis, but the contribution of silent plaque disruption to luminal stenosis progression has not been fully clarified. The aim of this study was therefore to examine the change in luminal stenosis at the site of silent plaque disruption. METHODS AND RESULTS: Consecutive patients (n=36) who received coronary angiography and angioscopy that identified silent plaque disruption (baseline) and had repeated coronary angiography later (follow-up) were included for analysis. Silent plaque disruption was defined as plaque with thrombus detected in non-culprit segments. Diameter stenosis of the site was angiographically measured at baseline and at follow-up, and their difference was defined as stenosis change. Statin was used in 89% of study patients, and serum low-density lipoprotein cholesterol level was 91 ± 21 mg/dl. The diameter stenosis decreased significantly from baseline to follow-up at 12 ± 4 months (32 ± 14% vs. 27 ± 14%, P<0.001), and the stenosis change was -5.6 ± 7.9%. High-density lipoprotein cholesterol (HDL-C) was significantly associated with stenosis change (r=-0.51, P=0.001) and was the only factor significantly associated with stenosis change. CONCLUSIONS: In the era of optimal medical therapy with statin, the site of silent plaque disruption showed significant regression of luminal stenosis. Nevertheless, serum HDL-C was inversely associated with stenosis change, and its low level remained as a potential risk of luminal stenosis progression at the site of silent plaque disruption.


Assuntos
HDL-Colesterol/sangue , Angiografia Coronária , Estenose Coronária , Placa Aterosclerótica , Idoso , Angioscopia , Estenose Coronária/sangue , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/sangue , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/fisiopatologia
7.
Circ J ; 75(10): 2432-8, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21778590

RESUMO

BACKGROUND: A low ratio of serum eicosapentaenoic acid to arachidonic acid (EPA/AA) has been associated with cardiovascular events. Higher-grade yellow color coronary plaques are associated with higher plaque vulnerability and higher thrombogenic potential. Therefore, the association between EPA/AA ratio and yellow color grade of coronary plaques was examined. METHODS AND RESULTS: Consecutive patients (n=54) who underwent percutaneous coronary intervention were enrolled in this study. The serum EPA/AA ratio was examined on admission. All patients underwent an angioscopic examination of the culprit vessel to examine the color grade of yellow plaques (0, white; 1, slight yellow; 2, yellow; and 3, intense yellow) and the presence of thrombus. Excluding 16 patients with acute coronary syndrome (ACS), 38 patients with stable angina were divided into 2 groups according to their EPA/AA ratio: the low EPA/AA group (n=19, EPA/AA ratio <0.37 [median]) and the high EPA/AA group (n=19, EPA/AA ratio ≥0.37). The maximum color grade (2.5 ± 0.5 vs. 1.9 ± 0.9; P=0.01) of yellow plaques was significantly higher and the number of non-culprit yellow plaques with thrombus (1.7 ± 0.8 vs. 1.2 ± 1.1; P=0.06) tended to be higher in low EPA/AA than in high EPA/AA stable angina patients. Multivariate analysis revealed that the serum EPA level (odds ratio=0.98, 95% confidence interval=0.96-0.99, P=0.03) was associated with the presence of grade-3 yellow plaques. CONCLUSIONS: A low serum EPA level and a low EPA/AA ratio was associated with high vulnerability of coronary plaques.


Assuntos
Ácidos Graxos Ômega-3/sangue , Ácidos Graxos Ômega-6/sangue , Placa Aterosclerótica/patologia , Idoso , Ácido Araquidônico/sangue , Cor , Trombose Coronária/etiologia , Trombose Coronária/patologia , Suscetibilidade a Doenças , Ácido Eicosapentaenoico/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/complicações
8.
Circ J ; 75(3): 603-12, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21187655

RESUMO

BACKGROUND: Clarification of frequency and distribution of yellow plaques and disrupted plaques will increase understanding of acute coronary syndrome (ACS) onset. METHODS AND RESULTS: Consecutive patients with ACS (n=75) or without ACS (n=90) who received coronary angioscopic examination were studied. Distance from ostium to yellow plaques, diameter stenosis and vessel wall irregularity at the site of yellow plaques, their yellow color grade (grade 13) and if they had thrombus were analyzed. Yellow plaques with thrombus were regarded as disrupted. Average number of yellow plaques, grade-3 yellow plaques and disrupted yellow plaques per vessel was 4.0, 0.87 and 1.0, respectively. The number of grade-3 yellow plaques and disrupted yellow plaques per vessel were larger in ACS than in non-ACS patients. Yellow plaques were distributed diffusely in the right coronary artery but more in mid-segments in the left anterior descending coronary artery and left circumflex coronary artery. Diameter stenosis in the non-culprit segments was severer at disrupted than at non-disrupted yellow plaques. Vessel wall irregularity was detected more frequently at disrupted than at non-disrupted yellow plaques. CONCLUSIONS: Approximately 4 yellow plaques, 1 grade-3 yellow plaque and 1 disrupted yellow plaque were detected per vessel. About 25% of detected yellow plaques were disrupted. More grade-3 yellow plaques and disrupted yellow plaques were detected in ACS than in non-ACS patients. These findings strengthen the association between yellow plaques detected by angioscopy and ACS events.


Assuntos
Síndrome Coronariana Aguda/epidemiologia , Síndrome Coronariana Aguda/patologia , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/patologia , Placa Aterosclerótica/epidemiologia , Placa Aterosclerótica/patologia , Síndrome Coronariana Aguda/complicações , Idoso , Angioscopia , Aspirina/uso terapêutico , Clopidogrel , Doença da Artéria Coronariana/complicações , Progressão da Doença , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/etiologia , Placa Aterosclerótica/complicações , Inibidores da Agregação Plaquetária/uso terapêutico , Estudos Retrospectivos , Índice de Gravidade de Doença , Ticlopidina/análogos & derivados , Ticlopidina/uso terapêutico
9.
J Cardiol ; 69(6): 859-867, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27614378

RESUMO

BACKGROUND: Dissociated pulmonary vein activity (DPVA), defined as isolated intrinsic ectopic beats observed after successful pulmonary vein (PV) isolation, indicates the presence of remnant foci of trigger ectopy but has yet to be extensively studied. We investigated the correlation between DPVA and the PV triggers of atrial fibrillation (AF). METHOD AND RESULTS: Consecutive 110 patients undergoing AF ablation were enrolled. We defined trigger ectopy as documented ectopic foci observed to spontaneously initiate AF. Trigger ectopy was detected in 62 (56%) patients. DPVA in at least one PV was detected in 95 (86%) patients. Of the 440 isolated PVs, we recognized trigger ectopy in 73 (16%) PVs (culprit PVs) and DPVA in 184 (42%) PVs. DPVA was more frequently observed in culprit PVs than in non-culprit PVs [59% vs. 39%; odds ratio (OR)=2.3; p=0.001]. The concordance ratio of culprit PV was 67% (8/12) in PV with fibrillatory DPVA, 20% (35/172) in PV with non-fibrillatory DPVA, and 12% (30/256) in PV without DPVA. Fibrillatory DPVA was more frequently observed in culprit PVs than non-fibrillatory DPVA (OR=7.8; p=0.001). Non-PV foci were observed in 10 (11%) of the 95 patients with DPVA and 5 (33%) of the 15 patients without DPVA (OR=4.3; p=0.02). No significant difference in the frequency of AF recurrence was observed between them. CONCLUSIONS: Fibrillatory DPVA was found to be strongly associated with trigger ectopy of AF. Non-fibrillatory DPVA might merely indicate the existence of bystander ectopic foci located inside PVs. Non-PV ectopic foci were frequently observed in patients without DPVA.


Assuntos
Fibrilação Atrial/fisiopatologia , Veias Pulmonares/fisiopatologia , Idoso , Fibrilação Atrial/cirurgia , Ablação por Cateter , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Resultado do Tratamento
10.
JACC Cardiovasc Interv ; 8(6): 814-821, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25999104

RESUMO

OBJECTIVES: This study examined whether coronary angioscopy-verified in-stent yellow plaque at 1 year after drug-eluting stent (DES) implantation is associated with future event of very late stent failure (VLSF). BACKGROUND: Atherosclerosis detected as yellow plaque by angioscopy has been associated with future events of acute coronary syndrome. Development of in-stent neoatherosclerosis is a probable mechanism of VLSF. METHODS: This study included 360 consecutive patients who received successful angioscopic examination at 1 year after implantation of a DES. They were clinically followed up for VLSF defined as cardiac death, acute myocardial infarction or unstable angina, or need for revascularization associated with the stent site. RESULTS: The follow-up interval was 1,558 ± 890 days (4.3 ± 2.4 years). The incidence of VLSF was significantly higher in the patients with yellow plaque than in those without (8.1% vs. 1.6%; log rank p = 0.02). Multivariable analysis revealed the presence of yellow plaque (hazard ratio [HR]: 5.38; p = 0.02) and absence of statin therapy (HR: 3.25; p = 0.02) as risks of VLSF. CONCLUSIONS: In-stent atherosclerosis evaluated by yellow plaque at 1 year after the implantation of DES and the absence of statin therapy were risks of VLSF. The underlying mechanism of VLSF appeared to be the progression of atherosclerosis as demonstrated by the yellow plaque.


Assuntos
Angioscopia , Doença da Artéria Coronariana/terapia , Reestenose Coronária/etiologia , Vasos Coronários/patologia , Stents Farmacológicos , Neointima , Intervenção Coronária Percutânea/instrumentação , Placa Aterosclerótica , Falha de Prótese , Idoso , Angina Instável/etiologia , Angina Instável/mortalidade , Angiografia Coronária , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/patologia , Reestenose Coronária/diagnóstico , Reestenose Coronária/mortalidade , Reestenose Coronária/patologia , Reestenose Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Progressão da Doença , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
J Cardiol Cases ; 9(5): 192-195, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-30534323

RESUMO

Yellow plaques detected by coronary angioscopy have been regarded as vulnerable plaques and associated with distal embolization or slow/no-flow phenomenon during coronary intervention. This is the first report that compared the findings of angioscopy and near-infrared spectroscopy (NIRS) in a patient who suffered no-flow phenomenon during coronary intervention. A 41-year-old male patient with silent myocardial ischemia received coronary intervention. Coronary angiogram revealed diffuse stenosis in the distal right coronary artery. Target lesion was examined by NIRS and angioscopy. NIRS can detect lipid core plaque, which is presented as an yellow area in contrast to the normal red area. Target segment was filled with lipid core plaques. On the other hand, angioscopy revealed a ruptured yellow plaque with a thrombus in the target segment. The distribution of yellow plaques detected by angioscopy appeared well corresponded to the yellow areas detected by NIRS. After the insertion of filter-type distal protection device, balloon pre-dilatation and stent implantation were performed. Then, no-flow phenomenon occurred. Coronary flow was finally recovered in the protected vessel but was still disturbed in the non-protected vessel. The filter was filled with much plaque debris. The correlation between the yellow area detected by NIRS and the yellow plaques detected by angioscopy appeared very well. .

12.
J Cardiol Cases ; 8(4): 138-141, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30546766

RESUMO

Although plaque rupture is the major cause of acute myocardial infarction, vasospasm is also known as a potential cause of acute myocardial infarction. However, it is very rare and is sometimes difficult to diagnose correctly. A 30-year-old male patient with suspected unstable angina pectoris who received catheterization in 1999 had normal coronary artery but positive result in the provocation test of vasospasm. Although his angina had been suppressed by medications, he suffered ST-elevation acute myocardial infarction after the discontinuation of medication. The initial angiogram showed total occlusion of the proximal left anterior descending coronary artery. Thrombolysis and nitroglycerin achieved recanalization of the culprit lesion with only mild residual stenosis. Angioscopy revealed normal white luminal wall without any thrombogenic lesion. Therefore, the cause of coronary occlusion was diagnosed as vasospasm. However, since the repeated vasospastic occlusion of the culprit lesion regardless of repeated intra-coronary injection of nitroglycerin was observed, a stent was implanted and vasospasm was successfully prevented. It is not easy to judge from the angiogram that the cause of coronary occlusion in the patients with acute myocardial infarction is vasospasm. It is important to think routinely about the possibility of vasospasm as a cause of acute myocardial infarction. .

13.
Heart Asia ; 5(1): 192-6, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-27326125

RESUMO

OBJECTIVE: Neoatherosclerosis or atherosclerosis progression is one of the mechanisms of long-term stent failure. Yellow plaque detected by angioscopy has been associated with advanced atherosclerosis and the future risk of a coronary event. We compared the yellow colour of the stented segment between zotarolimus-eluting stents (ZES) and everolimus-eluting stents (EES) at 1 year after implantation. DESIGN: Cross-sectional study. PATIENTS: Consecutive patients underwent angioscopic examination 1 year after the implantation of ZES (n=45) or EES (n=45) at a de novo native coronary lesion. MAIN OUTCOME MEASURES: The maximum yellow colour grade (grade 0-3) of the stented segment, maximum and minimum neointima coverage grade (grade 0-2) and the presence of thrombus were examined. The neointima heterogeneity index was calculated as maximum - minimum coverage grade. RESULTS: Maximum yellow colour grade was higher in EES than in ZES (1.3±0.9 vs 0.4±0.8, p<0.001) and maximum (2.0±0.2 vs 1.2±0.5, p<0.001) and minimum (1.5±0.6 vs 0.7±0.5, p<0.001) coverage grade was higher in ZES than in EES. The neointima heterogeneity index was not different between ZES and EES (0.4±0.5 vs 0.5±0.6, p=0.42). The incidence of thrombus was very low and was not different between ZES and EES (2% vs 4%, p=0.55). CONCLUSIONS: Although both ZES and EES had good healing with homogeneous neointima coverage and a low incidence of thrombus, EES had more advanced atherosclerosis as shown by the presence of higher grade yellow plaque than ZES at 1 year after implantation.

14.
J Cardiol ; 61(5): 326-9, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23465867

RESUMO

BACKGROUND: Although extremely high blood thrombogenicity has been reported in patients with acute myocardial infarction, it has not been clarified if the increased blood thrombogenicity is a cause of acute myocardial infarction or a mere result induced by thrombus formation at the disrupted plaque. Therefore, we examined if blood thrombogenicity is extremely increased as in acute myocardial infarction patients when disrupted plaque is present in patients with stable coronary artery disease. METHODS AND RESULTS: Consecutive patients (n=38) with stable coronary artery disease who received angioscopic examination were included. Patients were divided into two groups according to presence or absence of disrupted plaque that accompanied thrombus. Blood thrombogenicity was evaluated by blood vulnerability index and compared between the patients with and without disrupted plaque. Among 38 study patients, 16 had disrupted plaque and 22 did not. Blood vulnerability index was not different between the patients with and without disrupted plaque (2395 ± 612 vs. 3013 ± 1476, p=0.12). Multivariate analysis revealed no significant association between blood vulnerability index and the presence of disrupted plaque. CONCLUSION: The presence of disrupted plaque, in comparison with its absence, was not associated with higher blood thrombogenicity evaluated by blood vulnerability index.


Assuntos
Doença das Coronárias/sangue , Trombose Coronária/sangue , Vasos Coronários/patologia , Placa Aterosclerótica , Idoso , Angioscopia , Trombose Coronária/etiologia , Feminino , Humanos , Masculino
15.
EuroIntervention ; 9(2): 235-42, 2013 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-23793009

RESUMO

AIMS: Slow flow and no flow phenomena have been associated with distal embolisation, especially of plaque debris, and with unfavourable clinical outcomes. However, patients at high risk of distal embolisation for whom distal protection might be beneficial have not been adequately identified. We examined the frequency of distal embolisation and its predicting factors, including both ACS and non-ACS patients. METHODS AND RESULTS: Consecutive patients (n=98) with or without ACS who had received PCI with a filter-type distal protection device and successful angioscopic and VH-IVUS examination were prospectively enrolled. The presence of yellow plaque and plaque rupture was evaluated by angioscopy. Tissue classification and plaque burden was evaluated by VH-IVUS. Distal embolisation was evaluated by pathological examination of material collected in the filter. Distal embolisation of plaque debris was more frequently detected in patients with ACS (48% vs. 25%, p=0.02), in those with ruptured plaque (86% vs. 13%, p<0.001), in those with large (>75%) plaque burden (50% vs. 23%, p=0.006), and in those with grade 2/3 yellow plaque (52% vs. 7%, p<0.001), as compared to those without it. CONCLUSIONS: The presence of ruptured yellow plaque and of large plaque burden, rather than the setting of ACS, was highly predictive of distal embolisation of plaque debris.


Assuntos
Síndrome Coronariana Aguda/terapia , Angioscopia , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Embolia/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Placa Aterosclerótica , Ultrassonografia de Intervenção , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/patologia , Idoso , Distribuição de Qui-Quadrado , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Dispositivos de Proteção Embólica , Embolia/prevenção & controle , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Intervenção Coronária Percutânea/instrumentação , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco , Ruptura Espontânea , Fatores de Tempo , Resultado do Tratamento
16.
J Cardiol Cases ; 5(1): e12-e15, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30532892

RESUMO

Although very late stent thrombosis after drug-eluting stent implantation is a critical event, its cause has not been clarified. This is the first report of a case with very late stent thrombosis after drug-eluting stent implantation for which prior angioscopic image of the culprit lesion is available. A 54-year-old Japanese male patient with stable angina who received implantation of sirolimus-eluting stent at the culprit lesion and 1-year follow-up angiographic and angioscopic examinations came back with chest pain at rest at 2.5 years after the stent implantation. Very late stent thrombosis was diagnosed by emergent angiographic and angioscopic examinations and was treated by zotarolimus-eluting stent. One-year angiographic and angioscopic follow-up examinations after zotarolimus-eluting stent were performed. Angioscopy revealed uncovered stent strut, yellow plaques, and thrombus at 1-year follow-up after sirolimus-eluting stent implantation, and it confirmed the thrombotic occlusion inside the sirolimus-eluting stent at the time of emergent catheterization. This is a case of very late stent thrombosis in the drug-eluting stent where uncovered stent strut, yellow plaques, and thrombus had been detected by angioscopy 1.5 years before the onset. Those thrombogenic sources might be the cause of stent thrombosis.

17.
Thromb Res ; 129(2): 164-8, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21975031

RESUMO

INTRODUCTION: Yellow plaques are regarded vulnerable; and disrupted yellow plaques are the major cause of acute coronary syndrome. We examined the factors associated with the disruption of yellow plaques among patients and lesion characteristics. MATERIALS AND METHODS: Consecutive 161 patients with ischemic heart diseases who received coronary angioscopic examination were analyzed. Yellow plaques in the segments to which intervention had never been performed were included, and their yellow color grade and presence/ absence of disruption were examined. Associated factors for plaque disruption were examined among patients and lesion characteristics. RESULTS: In 161 patients, 392 yellow plaques were included for analysis and 70 of them were disrupted. Frequency of plaque disruption (=disrupted / all yellow plaques) was significantly higher at the segments of severer stenosis (stenosis≥75% vs. 75-25% vs. <25%: 34% vs. 21% vs. 14%, p=0.006). Multivariate analysis revealed angiographic stenosis (odds ratio [OR], 1.014; 95% confidence interval [CI], 1.005-1.023; p=0.003), yellow color grade (OR, 3.297; 95% CI, 2.062-5.273, p<0.001), LDL-cholesterol (OR, 1.012; 95% CI, 1.004-1.020, p=0.003), male gender (OR, 3.608; 95% CI, 1.538-8.465; p=0.003), and hypertension (OR, 2.552; 95% CI, 1.094-5.953; p=0.030) as significant associated factors for plaque disruption. CONCLUSION: Angiographic stenosis, yellow color grade, LDL-cholesterol, male gender, and hypertension were significantly associated with the disruption of yellow plaques.


Assuntos
LDL-Colesterol/sangue , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/patologia , Estenose Coronária/epidemiologia , Estenose Coronária/patologia , Hipertensão/epidemiologia , Hipertensão/patologia , Comorbidade , Estenose Coronária/sangue , Feminino , Humanos , Hipertensão/sangue , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Medição de Risco , Fatores de Risco , Distribuição por Sexo
18.
J Cardiol ; 58(1): 46-53, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21616641

RESUMO

BACKGROUND: Disruption of vulnerable plaques causes acute coronary syndrome and stenosis progression. Yellow plaques are regarded as vulnerable and the number of yellow plaques per vessel (NYP) has been reported as a marker of vulnerable patients. Therefore, we examined if patients with more yellow plaques would have higher risk of stenosis progression. METHODS AND RESULTS: A series of patients (n = 70) who received percutaneous coronary intervention (PCI) and angioscopy was included. Patients were divided into 2 groups according to NYP: group 1 (NYP <4, n = 32) and group 2 (NYP ≥ 4, n = 38). Coronary artery stenosis progression in any segment excluding target lesion of PCI was examined by angiography at 7 months. Maximum yellow color grade of yellow plaques (2.7 ± 0.7 vs. 1.7 ± 1.2, p < 0.0001) and the number of non-target disrupted yellow plaques was larger in group 2 than in group 1 (1.1 ± 1.5 vs. 0.2 ± 0.6, p=0.0017). Progression of coronary stenosis was detected more frequently in group 2 than in group 1 (29% vs. 9%, p = 0.041). The number of sites with stenosis progression was larger in group 2 than in group 1 (0.47 ± 0.98 vs. 0.09 ± 0.30 sites/patient, p = 0.036). CONCLUSIONS: Vulnerable patients with more yellow plaques had higher incidence of stenosis progression. Approximately 30% of vulnerable patients with NYP ≥ 4 had stenosis progression within 7 months.


Assuntos
Estenose Coronária/patologia , Vasos Coronários/patologia , Angioscopia , Angiografia Coronária , Doença da Artéria Coronariana/patologia , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
19.
Thromb Res ; 128(3): 268-73, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21531446

RESUMO

INTRODUCTION: Although thrombogenic potential of blood may play an important role for the onset of acute coronary syndrome (ACS), there is no established way to evaluate it by single parameter. We compared the thrombogenic potential of whole blood between patients with ACS and those with stable coronary diseases using single comprehensive parameter. MATERIALS AND METHODS: Consecutive patients with ACS (n=146) and those with stable coronary heart diseases (control, n=92) were prospectively examined. Thrombogenic potential of whole blood was evaluated by blood vulnerability index measured by Micro-Channel Array Flow Analyzer (MC-FAN). RESULTS: Blood vulnerability index was higher in ACS than in control patients (5099±2278 vs. 2071±389, p<0.0001), higher in acute MI than in unstable angina patients (5693±2146 vs. 3524±1841, p<0.0001), and higher in ACS patients with initial TIMI 0/1 flow grade than in those with TIMI 2/3 flow grade (6061±1936 vs. 2560±1301, p<0.0001). Furthermore, blood vulnerability index decreased from acute to chronic stage in acute MI patients. Multivariate logistic regression analysis revealed that high blood vulnerability index, high LDL cholesterol, high CRP, no use of aspirin, and no use of ß-blocker were the independent contributors for the onset of ACS. CONCLUSION: High thrombogenic potential of whole blood evaluated by blood vulnerability index was significantly associated with ACS and was reduced from acute to chronic stage in acute MI. CONDENSED ABSTRACT: Thrombogenic potential of whole blood was evaluated by blood vulnerability index measured comprehensively by Micro-Channel Array Flow Analyzer (MC-FAN) in consecutive patients with ACS (n=146) or stable coronary diseases (control, n=92) prospectively. Blood vulnerability index was significantly higher in ACS patients, especially in acute MI and poor initial TIMI flow grade patients, compared with control patients; and blood vulnerability index was reduced from acute to chronic stage in acute MI patients.


Assuntos
Síndrome Coronariana Aguda/sangue , Doença da Artéria Coronariana/sangue , Trombina/metabolismo , Síndrome Coronariana Aguda/patologia , Idoso , Feminino , Humanos , Masculino , Estudos Prospectivos
20.
Thromb Res ; 128(5): 431-4, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21676438

RESUMO

INTRODUCTION: Although very late stent thrombosis is an important problem with drug-eluting stents, risks for in-stent thrombus formation have not been clarified. Therefore, we examined the risks among patient and lesion characteristics by direct visualization of the stented lesion by angioscopy. MATERIALS AND METHODS: Consecutive patients (n=118) who received successful angioscopic examination of drug-eluting (sirolimus- or paclitaxel-eluting) stents at 1-year after implantation were included. Presence or absence of thrombus directly on the area of each condition determined by the combination of lesion color (white or yellow) and neointima coverage (grade 0-2) was evaluated for each stent; and the factors associated with the presence of thrombus were analyzed. RESULTS: Multivariate logistic regression analysis revealed lesion color (=yellow; odds ratio [OR] 5.5, 95% confidence interval [CI] 3.0-10, p<0.001), neointima coverage (=grade 0 or 1; OR 5.5, 95% CI 2.4-13, p<0.001), and stent type (=paclitaxel-eluting stent; OR 7.6, 95% CI 3.9-15, p<0.001) as independent contributors for in-stent thrombus formation. CONCLUSION: Yellow color of the lesion, poor neointima coverage, and use of paclitaxel-eluting stent were the risks of in-stent thrombus formation at 1 year after DES implantation.


Assuntos
Stents Farmacológicos/efeitos adversos , Trombose/etiologia , Idoso , Angioscopia , Cor , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neointima/patologia , Paclitaxel/uso terapêutico , Análise de Regressão , Risco , Fatores de Risco , Trombose/diagnóstico , Trombose/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA