Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Proc Natl Acad Sci U S A ; 120(9): e2220769120, 2023 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-36812211

RESUMO

S-Nitrosohemoglobin (SNO-Hb) is unique among vasodilators in coupling blood flow to tissue oxygen requirements, thus fulfilling an essential function of the microcirculation. However, this essential physiology has not been tested clinically. Reactive hyperemia following limb ischemia/occlusion is a standard clinical test of microcirculatory function, which has been ascribed to endothelial nitric oxide (NO). However, endothelial NO does not control blood flow governing tissue oxygenation, presenting a major quandary. Here we show in mice and humans that reactive hyperemic responses (i.e., reoxygenation rates following brief ischemia/occlusion) are in fact dependent on SNO-Hb. First, mice deficient in SNO-Hb (i.e., carrying C93A mutant Hb refractory to S-nitrosylation) showed blunted muscle reoxygenation rates and persistent limb ischemia during reactive hyperemia testing. Second, in a diverse group of humans-including healthy subjects and patients with various microcirculatory disorders-strong correlations were found between limb reoxygenation rates following occlusion and both arterial SNO-Hb levels (n = 25; P = 0.042) and SNO-Hb/total HbNO ratios (n = 25; P = 0.009). Secondary analyses showed that patients with peripheral artery disease had significantly reduced SNO-Hb levels and blunted limb reoxygenation rates compared with healthy controls (n = 8 to 11/group; P < 0.05). Low SNO-Hb levels were also observed in sickle cell disease, where occlusive hyperemic testing was deemed contraindicated. Altogether, our findings provide both genetic and clinical support for the role of red blood cells in a standard test of microvascular function. Our results also suggest that SNO-Hb is a biomarker and mediator of blood flow governing tissue oxygenation. Thus, increases in SNO-Hb may improve tissue oxygenation in patients with microcirculatory disorders.


Assuntos
Hiperemia , Humanos , Camundongos , Animais , Microcirculação , Hemoglobinas/genética , Eritrócitos/fisiologia , Oxigênio , Sujeitos da Pesquisa , Óxido Nítrico/fisiologia
2.
J Cardiovasc Electrophysiol ; 32(11): 3027-3034, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34554620

RESUMO

INTRODUCTION: Defibrillation testing (DT) is recommended during the subcutaneous defibrillator (S-ICD) placement. We sought to compare 10 J shock impedance in sinus rhythm (SR) with 65 J defibrillation impedance and evaluate device position on a postimplant chest X-ray (CXR) using an intermuscular (IM) technique. METHODS: Consecutive S-ICD implantations between 12/2019 and 12/2020 at The Ohio State University were reviewed. All implantations were performed using a two-incision IM technique. Standard DT with 65 J shock and 10 J shock in SR were performed unless contraindicated. The PRAETORIAN score was calculated based on CXR. RESULTS: A total of 37 patients (age: 47.2 ± 15.8 years old, male: n = 26 [70.3%], body mass index: 30.1 ± 6.7 kg/m2 ) underwent IM S-ICD implantation, and of those, 27 (73%) underwent both 65 J shock and 10 J shock in SR. The coefficient of determination (R2 ) between 10 J shock impedance and 65 J shock impedance was 0.84. The mean of an impedance difference was 1.6 ± 4.8 Ω (minimum - 11 and maximum 8). Postimplant CXR was available for 33 out of 37 patients (89.2%). The PRAETORIAN score was less than 90 in all patients and the mean score was 32.7 ± 8.8. CONCLUSION: We demonstrated that 10 J shock impedance in SR correlated well with 65 J defibrillation impedance during IM S-ICD implantation. An IM implantation technique provides excellent generator location on postimplant CXR. The IM technique combined with 10 J shock in SR may be sufficient to predict and ensure the defibrillation efficacy of the S-ICD.


Assuntos
Desfibriladores Implantáveis , Adulto , Arritmias Cardíacas , Cardioversão Elétrica , Impedância Elétrica , Humanos , Masculino , Pessoa de Meia-Idade , Ohio , Tela Subcutânea
3.
Proc Natl Acad Sci U S A ; 110(28): 11529-34, 2013 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-23798386

RESUMO

From the perspectives of disease transmission and sterility maintenance, the world's blood supplies are generally safe. However, in multiple clinical settings, red blood cell (RBC) transfusions are associated with adverse cardiovascular events and multiorgan injury. Because ∼85 million units of blood are administered worldwide each year, transfusion-related morbidity and mortality is a major public health concern. Blood undergoes multiple biochemical changes during storage, but the relevance of these changes to unfavorable outcomes is unclear. Banked blood shows reduced levels of S-nitrosohemoglobin (SNO-Hb), which in turn impairs the ability of stored RBCs to effect hypoxic vasodilation. We therefore reasoned that transfusion of SNO-Hb-deficient blood may exacerbate, rather than correct, impairments in tissue oxygenation, and that restoration of SNO-Hb levels would improve transfusion efficacy. Notably in mice, administration of banked RBCs decreased skeletal muscle pO2, but infusion of renitrosylated cells maintained tissue oxygenation. In rats, hemorrhage-induced reductions in muscle pO2 were corrected by SNO-Hb-repleted RBCs, but not by control, stored RBCs. In anemic awake sheep, stored renitrosylated, but not control RBCs, produced sustained improvements in O2 delivery; in anesthetized sheep, decrements in hemodynamic status, renal blood flow, and kidney function incurred following transfusion of banked blood were also prevented by renitrosylation. Collectively, our findings lend support to the idea that transfusions may be causally linked to ischemic events and suggest a simple approach to prevention (i.e., SNO-Hb repletion). If these data are replicated in clinical trials, renitrosylation therapy could have significant therapeutic impact on the care of millions of patients.


Assuntos
Transfusão de Sangue , Compostos Nitrosos/metabolismo , Oxigênio/metabolismo , Anemia/terapia , Animais , Hemorragia/terapia , Camundongos , Ratos , Ovinos
4.
J Interv Card Electrophysiol ; 66(1): 51-59, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34363567

RESUMO

PURPOSE: Left ventricular outflow tract (LVOT) arrhythmias are commonly targeted from the aortic sinuses of Valsalva (SOV). Both presystolic potentials during ventricular arrhythmia (VA) and late diastolic potentials during sinus rhythm have been recognized as markers of successful ablation sites. The study aimed to evaluate the utility of high resolution mapping (HRM) with small and closely spaced electrodes for guiding ablation of VA from the SOV. METHODS: Seventeen patients with LVOT VA underwent HRM in the SOV with either PentaRay (13) or Orion (4) catheters. Ablation was guided by low amplitude high frequency potentials that were identified with HRM and tagged on the electroanatomic map. RESULTS: High frequency low amplitude potentials during sinus rhythm (late) or VA (early) were demonstrated with HRM in all 17 consecutive patients; while these potentials were either absent or usually had a far-field appearance in the recordings obtained at the same sites with a 3.5-mm standard ablation catheter. On intracardiac echocardiogram, sites with these potentials corresponded to the bases of the sinuses adjacent to the LV ostium. Ablation was acutely successful in 16 out of 17 patients. Significant reduction in VA burden (≥ 90%) was noted in 15 patients. CONCLUSIONS: High frequency low amplitude potentials during sinus rhythm (late) and VA (early) are consistently recorded using HRM in the SOV in patients with VA arising from the aortic sinuses of Valsalva. Standard ablation catheters have limited resolution for detecting these potentials. HRM may potentially improve outcomes of ablation of VA originating from the aortic SOV.


Assuntos
Ablação por Cateter , Seio Aórtico , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Humanos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/cirurgia , Seio Aórtico/diagnóstico por imagem , Seio Aórtico/cirurgia , Aorta/cirurgia , Ventrículos do Coração/cirurgia , Eletrocardiografia , Complexos Ventriculares Prematuros/cirurgia , Resultado do Tratamento
5.
JACC Clin Electrophysiol ; 8(6): 795-799, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35738857

RESUMO

Thirty-eight patients had assessment of pulmonary vein occlusion with the dielectric mapping system and injection of saline as an alternative to contrast. Contrast injection was required to ascertain pulmonary vein occlusion in 31.6% (12 of 38) of subjects and 17.4% (27 of 155) of veins. No contrast was required in the last 13 subjects. In this single center study, a novel mapping-guided cryoablation approach appeared to minimize the use of contrast in pulmonary vein isolation for the treatment of atrial fibrillation.


Assuntos
Fibrilação Atrial , Criocirurgia , Veias Pulmonares , Pneumopatia Veno-Oclusiva , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Estudos de Viabilidade , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Pneumopatia Veno-Oclusiva/cirurgia , Resultado do Tratamento
6.
Expert Rev Med Devices ; 18(7): 587-596, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34057872

RESUMO

Introduction: Subcutaneous cardiac rhythm monitors (SCRMs) provide continuous ambulatory electrocardiographic monitoring for surveillance of known and identification of infrequent arrhythmias. SCRMs have proven to be helpful for the evaluation of unexplained symptoms and correlation with intermittent cardiac arrhythmias. Successful functioning of SCRM is dependent on accurate detection and successful transmission of the data to the device clinic. As the use of SCRM is steadily increasing, the amount of data that requires timely adjudication requires substantial resources. Newer algorithms for accurate detection and modified workflow systems have been proposed by physicians and the manufacturers to circumvent the issue of data deluge.Areas covered: This paper provides an overview of the various aspects of ambulatory rhythm monitoring with SCRMs including indications, implantation techniques, programming strategies, troubleshooting for issue of false positive and intermittent connectivity and strategies to circumvent data deluge.Expert opinion: SCRM is an invaluable technology for prolonged rhythm monitoring. The clinical benefits from SCRM hinge on accurate arrhythmia detection, reliable transmission of the data and timely adjudication for possible intervention. Further improvement in SCRM technology is needed to minimize false-positive detection, improve connectivity to the central web-based server, and devise strategies to minimize data deluge.


Assuntos
Fibrilação Atrial , Eletrocardiografia Ambulatorial , Algoritmos , Humanos
7.
Clin Transl Sci ; 11(2): 237-243, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29232772

RESUMO

Banked blood exhibits impairments in nitric oxide (NO)-based oxygen delivery capability, reflected in rapid depletion of S-nitrosohemoglobin (SNO-Hb). We hypothesized that transfusion of even freshly-stored blood used in pediatric heart surgery would reduce SNO-Hb levels and worsen outcome. In a retrospective review (n = 29), the percent of estimated blood volume (% eBV) replaced by transfusion directly correlated with ventilator time and inversely correlated with kidney function; similar results were obtained in a prospective arm (n = 20). In addition, an inverse association was identified between SNO-Hb and postoperative increase in Hb (∆Hb), reflecting the amount of blood retained by the patient. Both SNO-Hb and ∆Hb correlated with the probability of kidney dysfunction and oxygenation-related complications. Further, regression analysis identified SNO-Hb as an inverse predictor of outcome. The findings suggest that SNO-Hb and ∆Hb are prognostic biomarkers following pediatric cardiopulmonary bypass, and that maintenance of red blood cell-derived NO bioactivity might confer therapeutic benefit.


Assuntos
Ponte Cardiopulmonar/efeitos adversos , Transfusão de Eritrócitos/efeitos adversos , Cardiopatias Congênitas/cirurgia , Hemoglobinas/análise , Complicações Pós-Operatórias/epidemiologia , Biomarcadores/sangue , Transfusão de Eritrócitos/métodos , Eritrócitos/química , Eritrócitos/metabolismo , Feminino , Taxa de Filtração Glomerular , Hemoglobinas/metabolismo , Humanos , Incidência , Lactente , Recém-Nascido , Rim/metabolismo , Rim/fisiopatologia , Masculino , Óxido Nítrico/sangue , Óxido Nítrico/metabolismo , Oxigênio/sangue , Oxigênio/metabolismo , Consumo de Oxigênio , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/metabolismo , Complicações Pós-Operatórias/fisiopatologia , Estudos Prospectivos , Respiração Artificial/efeitos adversos , Estudos Retrospectivos , Fatores de Tempo
8.
Clin Pharmacol Ther ; 104(3): 553-563, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29238951

RESUMO

Disruption of microvascular blood flow is a common cause of tissue hypoxia in disease, yet no therapies are available that directly target the microvasculature to improve tissue oxygenation. Red blood cells (RBCs) autoregulate blood flow through S-nitroso-hemoglobin (SNO-Hb)-mediated export of nitric oxide (NO) bioactivity. We therefore tested the idea that pharmacological enhancement of RBCs using the S-nitrosylating agent ethyl nitrite (ENO) may provide a novel approach to improve tissue oxygenation. Serial ENO dosing was carried out in sheep (1-400 ppm) and humans (1-100 ppm) at normoxia and at reduced fraction of inspired oxygen (FiO2 ). ENO increased RBC SNO-Hb levels, corrected hypoxia-induced deficits in tissue oxygenation, and improved measures of oxygen utilization in both species. No adverse effects or safety concerns were identified. Inasmuch as impaired oxygenation is a major cause of morbidity and mortality, ENO may have widespread therapeutic utility, providing a first-in-class agent targeting the microvasculature.


Assuntos
Eritrócitos/efeitos dos fármacos , Hipóxia/tratamento farmacológico , Nitritos/administração & dosagem , Oxigênio/sangue , Vasodilatação/efeitos dos fármacos , Vasodilatadores/administração & dosagem , Adolescente , Adulto , Animais , Biomarcadores/sangue , Modelos Animais de Doenças , Eritrócitos/metabolismo , Feminino , Hemoglobinas/metabolismo , Humanos , Hipóxia/sangue , Hipóxia/fisiopatologia , Masculino , Óxido Nítrico/sangue , Nitritos/efeitos adversos , Carneiro Doméstico , Fatores de Tempo , Vasodilatadores/efeitos adversos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA