Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Am J Hematol ; 98(12): E383-E386, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37800361

RESUMO

THC triggers a pronounced entry of Ca2+ , which may be deleterious, into sickle cell red blood cells via activation of the TRPV2 channel.


Assuntos
Anemia Falciforme , Dronabinol , Humanos , Dronabinol/efeitos adversos , Eritrócitos , Anemia Falciforme/tratamento farmacológico
2.
Acta Anaesthesiol Scand ; 67(4): 455-461, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36644966

RESUMO

BACKGROUND: Volatile propofol can be measured in exhaled air and correlates to plasma concentrations with a time delay. However, the effect of single-lung ventilation on exhaled propofol is unclear. Therefore, our goal was to evaluate exhaled propofol concentrations during single-lung compared to double-lung ventilation using double-lumen tubes. METHODS: In a first step, we quantified adhesion of volatile propofol to the inner surface of double-lumen tubes during double- and single-lumen ventilation in vitro. In a second step, we enrolled 30 patients scheduled for lung surgery in two study centers. Anesthesia was provided with propofol and remifentanil. We utilized left-sided double-lumen tubes to separately ventilate each lung. Exhaled propofol concentrations were measured at 1-min intervals and plasma for propofol analyses was sampled every 20 min. To eliminate the influence of dosing on volatile propofol concentration, exhalation rate was normalized to plasma concentration. RESULTS: In-vitro ventilation of double-lumen tubes resulted in increasing propofol concentrations at the distal end of the tube over time. In vitro clamping the bronchial lumen led to an even more pronounced increase (Δ AUC +62%) in propofol gas concentration over time. Normalized propofol exhalation during lung surgery was 31% higher during single-lung compared to double-lung ventilation. CONCLUSION: During single-lung ventilation, propofol concentration in exhaled air, in contrast to our expectations, increased by approximately one third. However, this observation might not be affected by change in perfusion-ventilation during single-lung ventilation but rather arises from reduced propofol absorption on the inner surface area of the double-lumen tube. Thus, it is only possible to utilize exhaled propofol concentration to a limited extent during single-lung ventilation. REGISTRATION OF CLINICAL TRIAL: DRKS-ID DRKS00014788 (www.drks.de).


Assuntos
Anestesia , Ventilação Monopulmonar , Propofol , Humanos , Ventilação Monopulmonar/métodos , Expiração , Remifentanil , Intubação Intratraqueal/métodos
3.
Biophys J ; 121(1): 23-36, 2022 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-34896369

RESUMO

The dynamics of single red blood cells (RBCs) determine microvascular blood flow by adapting their shape to the flow conditions in the narrow vessels. In this study, we explore the dynamics and shape transitions of RBCs on the cellular scale under confined and unsteady flow conditions using a combination of microfluidic experiments and numerical simulations. Tracking RBCs in a comoving frame in time-dependent flows reveals that the mean transition time from the symmetric croissant to the off-centered, nonsymmetric slipper shape is significantly faster than the opposite shape transition, which exhibits pronounced cell rotations. Complementary simulations indicate that these dynamics depend on the orientation of the RBC membrane in the channel during the time-dependent flow. Moreover, we show how the tank-treading movement of slipper-shaped RBCs in combination with the narrow channel leads to oscillations of the cell's center of mass. The frequency of these oscillations depends on the cell velocity, the viscosity of the surrounding fluid, and the cytosol viscosity. These results provide a potential framework to identify and study pathological changes in RBC properties.

4.
Molecules ; 27(16)2022 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-36014494

RESUMO

Breath analysis provides great potential as a fast and non-invasive diagnostic tool for several diseases. Straight-chain aliphatic aldehydes were repeatedly detected in the breath of patients suffering from lung diseases using a variety of methods, such as mass spectrometry, ion mobility spectrometry, or electro-chemical sensors. Several studies found increased concentrations of exhaled aldehydes in patients suffering from lung cancer, inflammatory and infectious lung diseases, and mechanical lung injury. This article reviews the origin of exhaled straight-chain aliphatic aldehydes, available detection methods, and studies that found increased aldehyde exhalation in lung diseases.


Assuntos
Neoplasias Pulmonares , Compostos Orgânicos Voláteis , Aldeídos/análise , Biomarcadores/análise , Testes Respiratórios/métodos , Expiração , Humanos , Neoplasias Pulmonares/diagnóstico
5.
Anesth Analg ; 132(1): 110-118, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32118620

RESUMO

BACKGROUND: Propofol can be measured in exhaled gas. Exhaled and plasma propofol concentrations correlate well, but the relationship with tissue concentrations remains unknown. We thus evaluated the relationship between exhaled, plasma, and various tissue propofol concentrations. Because the drug acts in the brain, we focused on the relationship between exhaled and brain tissue propofol concentrations. METHODS: Thirty-six male Sprague-Dawley rats were anesthetized with propofol, ketamine, and rocuronium for 6 hours. Animals were randomly assigned to propofol infusions at 20, 40, or 60 mg·kg·h (n = 12 per group). Exhaled propofol concentrations were measured at 15-minute intervals by multicapillary column-ion mobility spectrometry. Arterial blood samples, 110 µL each, were collected 15, 30, and 45 minutes, and 1, 2, 4, and 6 hours after the propofol infusion started. Propofol concentrations were measured in brain, lung, liver, kidney, muscle, and fat tissue after 6 hours. The last exhaled and plasma concentrations were used for linear regression analyses with tissue concentrations. RESULTS: The correlation of exhaled versus plasma concentrations (R = 0.71) was comparable to the correlation of exhaled versus brain tissue concentrations (R = 0.75) at the end of the study. In contrast, correlations between plasma and lung and between lung and exhaled propofol concentrations were poor. Less than a part-per-thousand of propofol was exhaled over 6 hours. CONCLUSIONS: Exhaled propofol concentrations correlate reasonably well with brain tissue and plasma concentrations in rats, and may thus be useful to estimate anesthetic drug effect. The equilibration between plasma propofol and exhaled gas is apparently independent of lung tissue concentration. Only a tiny fraction of administered propofol is eliminated via the lungs, and exhaled quantities thus have negligible influence on plasma concentrations.


Assuntos
Anestésicos Intravenosos/metabolismo , Encéfalo/metabolismo , Plasma/metabolismo , Propofol/metabolismo , Anestésicos Intravenosos/administração & dosagem , Animais , Encéfalo/efeitos dos fármacos , Testes Respiratórios/métodos , Expiração/efeitos dos fármacos , Masculino , Plasma/efeitos dos fármacos , Propofol/administração & dosagem , Distribuição Aleatória , Ratos , Ratos Sprague-Dawley , Distribuição Tecidual/efeitos dos fármacos , Distribuição Tecidual/fisiologia
6.
Anesth Analg ; 133(1): 263-273, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33929393

RESUMO

BACKGROUND: Mechanical ventilation injures lungs, but there are currently no reliable methods for detecting early injury. We therefore evaluated whether exhaled pentanal, a lipid peroxidation product, might be a useful breath biomarker for stretch-induced lung injury in rats. METHODS: A total of 150 male Sprague-Dawley rats were investigated in 2 substudies. The first randomly assigned 75 rats to 7 hours of mechanical ventilation at tidal volumes of 6, 8, 12, 16, and 20 mL·kg-1. The second included 75 rats. A reference group was ventilated at a tidal volume of 6 mL·kg-1 for 10 hours 4 interventional groups were ventilated at a tidal volume of 6 mL·kg-1 for 1 hour, and then for 0.5, 1, 2, or 3 hours at a tidal volume of 16 mL.kg-1 before returning to a tidal volume of 6 mL·kg-1 for additional 6 hours. Exhaled pentanal was monitored by multicapillary column-ion mobility spectrometry. The first substudy included cytokine and leukocyte measurements in blood and bronchoalveolar fluid, histological assessment of the proportion of alveolar space, and measurements of myeloperoxidase activity in lung tissue. The second substudy included measurements of pentanal in arterial blood plasma, cytokine and leukocyte concentrations in bronchoalveolar fluid, and cleaved caspase 3 in lung tissue. RESULTS: Exhaled pentanal concentrations increased by only 0.5 ppb·h-1 (95% confidence interval [CI], 0.3-0.6) when rats were ventilated at 6 mL·kg-1. In contrast, exhaled pentanal concentrations increased substantially and roughly linearly at higher tidal volumes, up to 3.1 ppb·h-1 (95% CI, 2.3-3.8) at tidal volumes of 20 mL·kg-1. Exhaled pentanal increased at average rates between 1.0 ppb·h-1 (95% CI, 0.3-1.7) and 2.5 ppb·h-1 (95% CI, 1.4-3.6) after the onset of 16 mL·kg-1 tidal volumes and decreased rapidly by a median of 2 ppb (interquartile range [IQR], 0.9-3.2), corresponding to a 38% (IQR, 31-43) reduction when tidal volume returned to 6 mL·kg-1. Tidal volume, inspiratory pressure, and mechanical power were positively associated with pentanal exhalation. Exhaled and plasma pentanal were uncorrelated. Alveolar space decreased and inflammatory markers in bronchoalveolar lavage fluid increased in animals ventilated at high tidal volumes. Short, intermittent ventilation at high tidal volumes for up to 3 hours increased neither inflammatory markers in bronchoalveolar fluid nor the proportion of cleaved caspase 3 in lung tissue. CONCLUSIONS: Exhaled pentanal is a potential biomarker for early detection of ventilator-induced lung injury in rats.


Assuntos
Aldeídos/metabolismo , Expiração/fisiologia , Respiração Artificial/efeitos adversos , Lesão Pulmonar Induzida por Ventilação Mecânica/metabolismo , Aldeídos/análise , Anestésicos Inalatórios/administração & dosagem , Animais , Biomarcadores/metabolismo , Líquido da Lavagem Broncoalveolar/química , Expiração/efeitos dos fármacos , Masculino , Ratos , Ratos Sprague-Dawley , Sevoflurano/administração & dosagem , Volume de Ventilação Pulmonar/efeitos dos fármacos , Volume de Ventilação Pulmonar/fisiologia , Lesão Pulmonar Induzida por Ventilação Mecânica/etiologia
7.
Molecules ; 26(11)2021 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-34064214

RESUMO

Exhaled aliphatic aldehydes were proposed as non-invasive biomarkers to detect increased lipid peroxidation in various diseases. As a prelude to clinical application of the multicapillary column-ion mobility spectrometry for the evaluation of aldehyde exhalation, we, therefore: (1) identified the most abundant volatile aliphatic aldehydes originating from in vitro oxidation of various polyunsaturated fatty acids; (2) evaluated emittance of aldehydes from plastic parts of the breathing circuit; (3) conducted a pilot study for in vivo quantification of exhaled aldehydes in mechanically ventilated patients. Pentanal, hexanal, heptanal, and nonanal were quantifiable in the headspace of oxidizing polyunsaturated fatty acids, with pentanal and hexanal predominating. Plastic parts of the breathing circuit emitted hexanal, octanal, nonanal, and decanal, whereby nonanal and decanal were ubiquitous and pentanal or heptanal not being detected. Only pentanal was quantifiable in breath of mechanically ventilated surgical patients with a mean exhaled concentration of 13 ± 5 ppb. An explorative analysis suggested that pentanal exhalation is associated with mechanical power-a measure for the invasiveness of mechanical ventilation. In conclusion, exhaled pentanal is a promising non-invasive biomarker for lipid peroxidation inducing pathologies, and should be evaluated in future clinical studies, particularly for detection of lung injury.


Assuntos
Aldeídos/análise , Testes Respiratórios , Respiração Artificial , Compostos Orgânicos Voláteis/análise , Humanos , Técnicas In Vitro , Projetos Piloto
8.
Molecules ; 26(9)2021 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-34067078

RESUMO

High inspired oxygen during mechanical ventilation may influence the exhalation of the previously proposed breath biomarkers pentanal and hexanal, and additionally induce systemic inflammation. We therefore investigated the effect of various concentrations of inspired oxygen on pentanal and hexanal exhalation and serum interleukin concentrations in 30 Sprague Dawley rats mechanically ventilated with 30, 60, or 93% inspired oxygen for 12 h. Pentanal exhalation did not differ as a function of inspired oxygen but increased by an average of 0.4 (95%CI: 0.3; 0.5) ppb per hour, with concentrations doubling from 3.8 (IQR: 2.8; 5.1) ppb at baseline to 7.3 (IQR: 5.0; 10.8) ppb after 12 h. Hexanal exhalation was slightly higher at 93% of inspired oxygen with an average difference of 0.09 (95%CI: 0.002; 0.172) ppb compared to 30%. Serum IL-6 did not differ by inspired oxygen, whereas IL-10 at 60% and 93% of inspired oxygen was greater than with 30%. Both interleukins increased over 12 h of mechanical ventilation at all oxygen concentrations. Mechanical ventilation at high inspired oxygen promotes pulmonary lipid peroxidation and systemic inflammation. However, the response of pentanal and hexanal exhalation varies, with pentanal increasing by mechanical ventilation, whereas hexanal increases by high inspired oxygen concentrations.


Assuntos
Aldeídos/farmacologia , Expiração/efeitos dos fármacos , Oxigênio/farmacologia , Respiração Artificial , Animais , Testes Respiratórios , Citocinas/sangue , Inflamação/patologia , Masculino , Pressão Parcial , Ratos Sprague-Dawley
9.
Crit Care Med ; 47(2): 239-246, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30365402

RESUMO

OBJECTIVES: To characterize volatile organic compounds in breath exhaled by ventilated care patients with acute kidney injury and changes over time during dialysis. DESIGN: Prospective observational feasibility study. SETTING: Critically ill patients on an ICU in a University Hospital, Germany. PATIENTS: Twenty sedated, intubated, and mechanically ventilated patients with acute kidney injury and indication for dialysis. INTERVENTIONS: Patients exhalome was evaluated from at least 30 minutes before to 7 hours after beginning of continuous venovenous hemodialysis. MEASUREMENTS AND MAIN RESULTS: Expired air samples were aspirated from the breathing circuit at 20-minute intervals and analyzed using multicapillary column ion-mobility spectrometry. Volatile organic compound intensities were compared with a ventilated control group with normal renal function. A total of 60 different signals were detected by multicapillary column ion-mobility spectrometry, of which 44 could be identified. Thirty-four volatiles decreased during hemodialysis, whereas 26 remained unaffected. Forty-five signals showed significant higher intensities in patients with acute kidney injury compared with control patients with normal renal function. Among these, 30 decreased significantly during hemodialysis. Volatile cyclohexanol (23 mV; 2575th, 19-38), 3-hydroxy-2-butanone (16 mV, 9-26), 3-methylbutanal (20 mV; 14-26), and dimer of isoprene (26 mV; 18-32) showed significant higher intensities in acute kidney impairment compared with control group (12 mV; 10-16 and 8 mV; 7-14 and not detectable and 4 mV; 0-6; p < 0.05) and a significant decline after 7 hours of continuous venovenous hemodialysis (16 mV; 13-21 and 7 mV; 6-13 and 9 mV; 8-13 and 14 mV; 10-19). CONCLUSIONS: Exhaled concentrations of 45 volatile organic compounds were greater in critically ill patients with acute kidney injury than in patients with normal renal function. Concentrations of two-thirds progressively decreased during dialysis. Exhalome analysis may help quantify the severity of acute kidney injury and to gauge the efficacy of dialysis.


Assuntos
Injúria Renal Aguda/metabolismo , Compostos Orgânicos Voláteis/metabolismo , Injúria Renal Aguda/terapia , Idoso , Testes Respiratórios , Expiração , Estudos de Viabilidade , Feminino , Humanos , Masculino , Estudos Prospectivos , Diálise Renal , Respiração Artificial , Compostos Orgânicos Voláteis/análise
10.
Biomed Chromatogr ; 33(8): e4540, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30924939

RESUMO

The combination of propofol, ketamine and rocuronium can be used for anesthesia of ventilated rats. However, reliable pharmacokinetic models of these drugs have yet to be developed in rats, and consequently optimal infusion strategies are also unknown. Development of pharmacokinetic models requires repeated measurements of drug concentrations. In small animals, samples must be tiny to avoid excessing blood extraction. We therefore developed a drug assay system using high-performance liquid chromatography coupled with quadrupole mass spectrometry that simultaneously determines the concentration of all three drugs in just 10 µL rat plasma. We established a plasma extraction protocol, using acetonitrile as the precipitating reagent. Calibration curves were linear with R2 = 0.99 for each drug. Mean recovery from plasma was 91-93% for propofol, 89-93% for ketamine and 90-92% for rocuronium. The assay proved to be accurate for propofol 4.1-8.3%, ketamine 1.9-7.8% and rocuronium -3.6-4.7% relative error. The assay was also precise; the intra-day precisions were propofol 2.0-4.0%, ketamine 2.7-2.9% and rocuronium 2.9-3.3% relative standard deviation. Finally, the method was successfully applied to measurement the three drugs in rat plasma samples. Mean plasma concentrations with standard deviations were propofol 2.0 µg/mL ±0.5%, ketamine 3.9 µg/mL ±1.0% and rocuronium 3.2 µg/mL ±0.8% during ventilation.


Assuntos
Cromatografia Líquida/métodos , Ketamina/sangue , Espectrometria de Massas/métodos , Propofol/sangue , Rocurônio/sangue , Animais , Ketamina/química , Ketamina/farmacocinética , Limite de Detecção , Modelos Lineares , Masculino , Projetos Piloto , Propofol/química , Propofol/farmacocinética , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Rocurônio/química , Rocurônio/farmacocinética
11.
BMC Pulm Med ; 17(1): 116, 2017 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-28830533

RESUMO

BACKGROUND: Expired gas (exhalome) analysis of ventilated critical ill patients can be used for drug monitoring and biomarker diagnostics. However, it remains unclear to what extent volatile organic compounds are present in gases from intensive care ventilators, gas cylinders, central hospital gas supplies, and ambient air. We therefore systematically evaluated background volatiles in inspired gas and their influence on the exhalome. METHODS: We used multi-capillary column ion-mobility spectrometry (MCC-IMS) breath analysis in five mechanically ventilated critical care patients, each over a period of 12 h. We also evaluated volatile organic compounds in inspired gas provided by intensive care ventilators, in compressed air and oxygen from the central gas supply and cylinders, and in the ambient air of an intensive care unit. Volatiles detectable in both inspired and exhaled gas with patient-to-inspired gas ratios < 5 were defined as contaminating compounds. RESULTS: A total of 76 unique MCC-IMS signals were detected, with 39 being identified volatile compounds: 73 signals were from the exhalome, 12 were identified in inspired gas from critical care ventilators, and 34 were from ambient air. Five volatile compounds were identified from the central gas supply, four from compressed air, and 17 from compressed oxygen. We observed seven contaminating volatiles with patient-to-inspired gas ratios < 5, thus representing exogenous signals of sufficient magnitude that might potentially be mistaken for exhaled biomarkers. CONCLUSIONS: Volatile organic compounds can be present in gas from central hospital supplies, compressed gas tanks, and ventilators. Accurate assessment of the exhalome in critical care patients thus requires frequent profiling of inspired gases and appropriate normalisation of the expired signals.


Assuntos
Testes Respiratórios , Expiração , Respiração Artificial , Compostos Orgânicos Voláteis/análise , Idoso , Biomarcadores , Humanos , Unidades de Terapia Intensiva , Pessoa de Meia-Idade , Doenças Respiratórias/diagnóstico , Compostos Orgânicos Voláteis/química
12.
Anesthesiology ; 122(1): 117-26, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25170570

RESUMO

BACKGROUND: Multicapillary column ion-mobility spectrometry (MCC-IMS) may identify volatile components in exhaled gas. The authors therefore used MCC-IMS to evaluate exhaled gas in a rat model of sepsis, inflammation, and hemorrhagic shock. METHODS: Male Sprague-Dawley rats were anesthetized and ventilated via tracheostomy for 10 h or until death. Sepsis was induced by cecal ligation and incision in 10 rats; a sham operation was performed in 10 others. In 10 other rats, endotoxemia was induced by intravenous administration of 10 mg/kg lipopolysaccharide. In a final 10 rats, hemorrhagic shock was induced to a mean arterial pressure of 35 ± 5 mmHg. Exhaled gas was analyzed with MCC-IMS, and volatile compounds were identified using the BS-MCC/IMS-analytes database (Version 1209; B&S Analytik, Dortmund, Germany). RESULTS: All sham animals survived the observation period, whereas mean survival time was 7.9 h in the septic animals, 9.1 h in endotoxemic animals, and 2.5 h in hemorrhagic shock. Volatile compounds showed statistically significant differences in septic and endotoxemic rats compared with sham rats for 3-pentanone and acetone. Endotoxic rats differed significantly from sham for 1-propanol, butanal, acetophenone, 1,2-butandiol, and 2-hexanone. Statistically significant differences were observed between septic and endotoxemic rats for butanal, 3-pentanone, and 2-hexanone. 2-Hexanone differed from all other groups in the rats with shock. CONCLUSIONS: Breath analysis of expired organic compounds differed significantly in septic, inflammation, and sham rats. MCC-IMS of exhaled breath deserves additional study as a noninvasive approach for distinguishing sepsis from inflammation.


Assuntos
Testes Respiratórios/métodos , Inflamação/metabolismo , Sepse/metabolismo , Análise Espectral/métodos , Compostos Orgânicos Voláteis/metabolismo , Animais , Modelos Animais de Doenças , Expiração , Inflamação/diagnóstico , Íons , Masculino , Ratos , Ratos Sprague-Dawley , Sepse/diagnóstico , Choque Hemorrágico/metabolismo
13.
Anal Bioanal Chem ; 407(13): 3763-73, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25808025

RESUMO

The analysis of exhaled metabolites has become a promising field of research in recent decades. Several volatile organic compounds reflecting metabolic disturbance and nutrition status have even been reported. These are particularly important for long-term measurements, as needed in medical research for detection of disease progression and therapeutic efficacy. In this context, it has become urgent to investigate the effect of fasting and glucose treatment for breath analysis. In the present study, we used a model of ventilated rats that fasted for 12 h prior to the experiment. Ten rats per group were randomly assigned for continuous intravenous infusion without glucose or an infusion including 25 mg glucose per 100 g per hour during an observation period of 12 h. Exhaled gas was analysed using multicapillary column ion-mobility spectrometry. Analytes were identified by the BS-MCC/IMS database (version 1209; B & S Analytik, Dortmund, Germany). Glucose infusion led to a significant increase in blood glucose levels (p < 0.05 at 4 h and thereafter) and cardiac output (p < 0.05 at 4 h and thereafter). During the observation period, 39 peaks were found collectively. There were significant differences between groups in the concentration of ten volatile organic compounds: p < 0.001 at 4 h and thereafter for isoprene, cyclohexanone, acetone, p-cymol, 2-hexanone, phenylacetylene, and one unknown compound, and p < 0.001 at 8 h and thereafter for 1-pentanol, 1-propanol, and 2-heptanol. Our results indicate that for long-term measurement, fasting and the withholding of glucose could contribute to changes of volatile metabolites in exhaled air.


Assuntos
Glicemia/metabolismo , Testes Respiratórios/métodos , Expiração/fisiologia , Jejum/metabolismo , Glucose/administração & dosagem , Compostos Orgânicos Voláteis/análise , Animais , Gasometria/métodos , Masculino , Ratos , Ratos Sprague-Dawley
15.
Plant Mol Biol ; 85(3): 233-45, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24549883

RESUMO

The establishment of the photosynthetic apparatus during chloroplast development creates a high demand for iron as a redox metal. However, iron in too high quantities becomes toxic to the plant, thus plants have evolved a complex network of iron uptake and regulation mechanisms. Here, we examined whether four of the subgroup Ib basic helix-loop-helix transcription factors (bHLH38, bHLH39, bHLH100, bHLH101), previously implicated in iron homeostasis in roots, also play a role in regulating iron metabolism in developing leaves. These transcription factor genes were strongly up-regulated during the transition from cell proliferation to expansion, and thus sink-source transition, in young developing leaves of Arabidopsis thaliana. The four subgroup Ib bHLH genes also showed reduced expression levels in developing leaves of plants treated with norflurazon, indicating their expression was tightly linked to the onset of photosynthetic activity in young leaves. In addition, we provide evidence for a mechanism whereby the transcriptional regulators SAC51 and TCP20 antagonistically regulate the expression of these four subgroup Ib bHLH genes. A loss-of-function mutant analysis also revealed that single mutants of bHLH38, bHLH39, bHLH100, and bHLH101 developed smaller rosettes than wild-type plants in soil. When grown in agar plates with reduced iron concentration, triple bhlh39 bhlh100 bhlh101 mutant plants were smaller than wild-type plants. However, measurements of the iron content in single and multiple subgroup Ib bHLH genes, as well as transcript profiling of iron response genes during early leaf development, do not support a role for bHLH38, bHLH39, bHLH100, and bHLH101 in iron homeostasis during early leaf development.


Assuntos
Proteínas de Arabidopsis/metabolismo , Arabidopsis/metabolismo , Fatores de Transcrição Hélice-Alça-Hélice Básicos/metabolismo , Diferenciação Celular/fisiologia , Cloroplastos/fisiologia , Folhas de Planta/citologia , Fatores de Transcrição/metabolismo , Arabidopsis/genética , Proteínas de Arabidopsis/genética , Fatores de Transcrição Hélice-Alça-Hélice Básicos/genética , Diferenciação Celular/efeitos dos fármacos , Linhagem Celular , Regulação da Expressão Gênica de Plantas , Herbicidas/farmacologia , Ferro , Complexo de Proteína do Fotossistema II , Folhas de Planta/efeitos dos fármacos , Piridazinas/farmacologia , Nicotiana/citologia , Fatores de Transcrição/genética , Transcriptoma
16.
Environ Sci Technol ; 47(19): 10912-21, 2013 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-24050604

RESUMO

Cation binding and electron transfer reactions of humic substances determine copper speciation in redox-dynamic systems, but quantitative studies for Cu+ binding to humic substances are lacking. We investigated reduction of Cu2+ and binding of Cu+ at pH 7.0 in a dialysis cell experiment using reduced and reoxidized soil humic acid (HA) as reductant and sorbent at copper loadings of 9.5-600 mmol kg(-1). The data were used to quantitatively explain the interaction between cation binding and electron transfer processes that determine copper speciation in the presence of HA under anoxic and oxic conditions. Addition of Cu2+ to reduced HA resulted in almost complete reduction to Cu(I) within 1 h. Reduction was also significant under oxic conditions. The slow decrease of the Cu(I) fraction was attributed to formation of Cu(0) based on thermodynamic consideration. Cu+ binding to HA was found to be strong compared to other chalcophile cations like Ag+ or Cd2+. Our results indicate that Cu+ and Cu2+ isotherms exhibit a redox potential-dependent intersection point. According to the differences in Cu+ and Cu2+ binding, the presence of HA was found to extend the stability field of Cu(II) to moderately reducing conditions and to reduce the stability field of Cu(0) due to the formation of Cu(I) complexes.


Assuntos
Cobre/química , Substâncias Húmicas , Solo/química , Diálise , Oxirredução , Potenciometria
17.
Environ Sci Technol ; 47(19): 10903-11, 2013 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-24050649

RESUMO

Natural organic matter (NOM) exerts strong influence on copper speciation and bioavailability in soils and aquatic systems. In redox-dynamic environments, electron transfer reactions between copper and redox-active moieties of NOM may trigger Cu(I) and Cu(0) formation. To date, little is known about Cu-NOM redox interactions and Cu(I) binding to NOM. Here, we present X-ray absorption spectroscopy results on copper redox transformations upon addition of Cu(II) or Cu(I) to untreated and electrochemically reduced soil humic acid (HA) under oxic and anoxic conditions. Both untreated and reduced HA mediated copper redox transformations. Under anoxic conditions, Cu(II) and Cu(I) added to reduced HA were primarily complexed and thereby stabilized as Cu(I)-HA at low loadings, whereas high copper loadings resulted in the additional formation of Cu(0) nanoparticles (16-64% of total copper). Cu(I) bound to HA was predominantly 2-fold coordinated and to a lower extent 3- to 4-fold coordinated, with a contribution of at least one nitrogen and/or sulfur ligand group. Under oxic conditions, Cu(II)-HA complexes prevailed, but smaller fractions of copper were also stabilized as Cu(I)-HA in a 3- to 4-fold coordination. Our results show that Cu-HA redox interactions are strongly affected by binding of Cu(II) and Cu(I) to HA and that HA contributes to the stabilization of Cu(I) against disproportionation.


Assuntos
Cobre/química , Substâncias Húmicas , Solo/química , Oxirredução , Oxigênio/química , Espectroscopia por Absorção de Raios X
18.
Sci Rep ; 13(1): 18132, 2023 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-37875513

RESUMO

The aim of this study was to investigate the pharmacokinetics of multiple-dose intravenous (i.v.) fosfomycin in critically ill patients during continuous venovenous hemodialysis (CVVHD). Non-compartmental analysis and population pharmacokinetic modeling were used to simulate different dosing regimens. We evaluated 15 critically ill patients with renal insufficiency and CVVHD undergoing anti-infective treatment with fosfomycin in our ICU. Five grams of fosfomycin were administered for 120 min every 6 h. Plasma concentrations were determined with and without CVVHD. Pharmacokinetic analysis and simulations were performed using non-linear mixed effects modelling (NONMEM). A two-compartment model with renal and dialysis clearance was most accurate in describing the pharmacokinetics of i.v. fosfomycin during CVVHD. Population parameter estimates were 18.20 L and 20.80 L for the central and peripheral compartment volumes, and 0.26 L/h and 5.08 L/h for renal and intercompartmental clearance, respectively. Urinary creatinine clearance (CLCR) represented a considerable component of renal clearance. Central compartment volume increased over time after the first dose. For patients with CLCR > 50 (90) mL/min and CVVHD, dosage should be increased to ≥ 15 (16) grams of i.v. fosfomycin across three (four) daily doses. Individual CLCR must be considered when dosing i.v. fosfomycin in critically ill patients during CVVHD.


Assuntos
Terapia de Substituição Renal Contínua , Fosfomicina , Humanos , Fosfomicina/uso terapêutico , Antibacterianos , Estado Terminal , Diálise Renal
19.
Environ Sci Technol ; 46(16): 8808-16, 2012 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-22809322

RESUMO

Naturally occurring variations of redox conditions are considered to affect the interactions between trace metals and humic substances in a 2-fold manner. First, additional proton binding sites of humic substances formed under reducing conditions may also act as binding sites for trace metals. Second, reduced humic substances may transfer electrons to redox-active trace metals. In this study, we investigated the influence of electrochemical reduction of a purified soil humic acid on the binding of two chalcophile metal cations of environmental concern, Cd(2+) and Ag(+), with metal titrations conducted under monitored redox conditions. The binding of cadmium to reduced humic acid was slightly enhanced compared to humic acid reoxidized by O(2) and quantitatively in excellent agreement with the increase in binding sites formed upon reduction. Competitive experiments with calcium indicated that sulfur-containing sites played a minor role in cadmium binding, although sulfur K-edge XANES revealed that 36% of humic sulfur was in a reduced oxidation state. In all experiments with silver, the formation of Ag(0) was detected with transmission electron microscopy. Free Ag(+) activities under reducing conditions were controlled by Ag(0) formation rather than by binding to humic acid.


Assuntos
Cádmio/química , Substâncias Húmicas , Prata/química , Microscopia Eletrônica de Transmissão , Oxirredução
20.
Cells ; 11(8)2022 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-35455975

RESUMO

(1) Background: When red blood cells are centrifuged in a continuous Percoll-based density gradient, they form discrete bands. While this is a popular approach for red blood cell age separation, the mechanisms involved in banding were unknown. (2) Methods: Percoll centrifugations of red blood cells were performed under various experimental conditions and the resulting distributions analyzed. The age of the red blood cells was measured by determining the protein band 4.1a to 4.1b ratio based on western blots. Red blood cell aggregates, so-called rouleaux, were monitored microscopically. A mathematical model for the centrifugation process was developed. (3) Results: The red blood cell band pattern is reproducible but re-centrifugation of sub-bands reveals a new set of bands. This is caused by red blood cell aggregation. Based on the aggregation, our mathematical model predicts the band formation. Suppression of red blood cell aggregation reduces the band formation. (4) Conclusions: The red blood cell band formation in continuous Percoll density gradients could be explained physically by red blood cell aggregate formation. This aggregate formation distorts the density-based red blood cell age separation. Suppressing aggregation by osmotic swelling has a more severe effect on compromising the RBC age separation to a higher degree.


Assuntos
Eritrócitos , Povidona , Separação Celular/métodos , Centrifugação com Gradiente de Concentração , Dióxido de Silício
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA