Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Radiology ; 306(3): e221250, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36125379

RESUMO

Background Long COVID occurs at a lower frequency in children and adolescents than in adults. Morphologic and free-breathing phase-resolved functional low-field-strength MRI may help identify persistent pulmonary manifestations after SARS-CoV-2 infection. Purpose To characterize both morphologic and functional changes of lung parenchyma at low-field-strength MRI in children and adolescents with post-COVID-19 condition compared with healthy controls. Materials and Methods Between August and December 2021, a cross-sectional clinical trial using low-field-strength MRI was performed in children and adolescents from a single academic medical center. The primary outcome was the frequency of morphologic changes at MRI. Secondary outcomes included MRI-derived functional proton ventilation and perfusion parameters. Clinical symptoms, the duration from positive reverse transcriptase-polymerase chain reaction test result, and serologic parameters were compared with imaging results. Nonparametric tests for pairwise and corrected tests for groupwise comparisons were applied to assess differences in healthy controls, recovered participants, and those with long COVID. Results A total of 54 participants after COVID-19 infection (mean age, 11 years ± 3 [SD]; 30 boys [56%]) and nine healthy controls (mean age, 10 years ± 3; seven boys [78%]) were included: 29 (54%) in the COVID-19 group had recovered from infection and 25 (46%) were classified as having long COVID on the day of enrollment. Morphologic abnormality was identified in one recovered participant. Both ventilated and perfused lung parenchyma (ventilation-perfusion [V/Q] match) was higher in healthy controls (81% ± 6.1) compared with the recovered group (62% ± 19; P = .006) and the group with long COVID (60% ± 20; P = .003). V/Q match was lower in patients with time from COVID-19 infection to study participation of less than 180 days (63% ± 20; P = .03), 180-360 days (63% ± 18; P = .03), and 360 days (41% ± 12; P < .001) as compared with the never-infected healthy controls (81% ± 6.1). Conclusion Low-field-strength MRI showed persistent pulmonary dysfunction in children and adolescents who recovered from COVID-19 and those with long COVID. Clinical trial registration no. NCT04990531 © RSNA, 2022 Supplemental material is available for this article. See also the editorial by Paltiel in this issue.


Assuntos
COVID-19 , Adolescente , Adulto , Criança , Humanos , Masculino , Estudos Transversais , Pulmão/diagnóstico por imagem , Síndrome de COVID-19 Pós-Aguda , SARS-CoV-2
2.
J Fam Issues ; 44(1): 25-45, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36605179

RESUMO

Governments of numerous countries implemented school closures to contain the COVID-19 pandemic. Several investigations have shown the negative impact of social-distancing policies and school closures on children worldwide. Recently, research also demonstrated adverse effects on adults' well-being. The development of children is strongly affected by their parent's emotional state. The present study aimed to examine parental stress levels caused by a short period of homeschooling in December 2020 in Germany. A structured survey was set up and distributed randomly via social media and parent associations. We observed a significant increase in stress and concerns. Family conflicts significantly increased, social isolation was feared, and powerlessness and helplessness ascended. Risk factors were parental education levels, parental working time, and teaching features like the frequency of feedback, correction, and accessibility.

3.
Radiologe ; 62(5): 410-417, 2022 May.
Artigo em Alemão | MEDLINE | ID: mdl-35416477

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) plays a crucial role in musculoskeletal imaging. The high prevalence and pain-related suffering of patients pose a particular challenge concerning availability and turnover times, respectively. Low-field (≤ 1.0 T) MRI has the potential to fulfill these needs. However, during the past three decades, high field systems have increasingly replaced low field systems because of their limitations in image quality. Recent technological advancements in high-performance hard- and software promise musculoskeletal imaging with adequate quality at lower field strengths for several regions and indications. OBJECTIVES: The goal is to provide insight into the advantages and disadvantages of low-field musculoskeletal imaging, discuss the current literature, and include our first experiences with a modern 0.55 T MRI. MATERIALS AND METHODS: This review is based on research in various literature databases and our own musculoskeletal imaging experiences with a modern 0.55 T scanner. CONCLUSION: Most publications pertaining to musculoskeletal imaging at low-field strength MRI are outdated, and studies regarding the diagnostic performance of modern low-field MRI systems are needed. These new systems may complement existing high-field systems and make MRI more accessible, even in low-income countries. From our own experience, modern low-field MRI seems to be adequate in musculoskeletal imaging, especially in acute injuries.


Assuntos
Imageamento por Ressonância Magnética , Sistema Musculoesquelético , Humanos , Imageamento por Ressonância Magnética/métodos , Sistema Musculoesquelético/diagnóstico por imagem , Software
4.
Radiologe ; 62(5): 418-428, 2022 May.
Artigo em Alemão | MEDLINE | ID: mdl-35416476

RESUMO

BACKGROUND: Lung magnetic resonance imaging (MRI) examinations are challenging and have not become established in the routine clinical setting. Recent developments in low-field MRI, combined with computer-assisted algorithms for acquisition and evaluation, promise new perspectives for imaging of pulmonary diseases. OBJECTIVES: This review aims to inform about the physical advantages of low-field MRI for imaging the lungs, provide a review of the sparse literature, and present first results from a new low-field MRI scanner. MATERIALS AND METHODS: This article provides information on the physical principles, an review of the literature, and our first experiences in lung imaging on a modern 0.55 T MRI. CONCLUSION: Low-field MRI (< 1 T) may have technical and economic advantages over higher field strength MRI in lung imaging. The physical preconditions of low-field MRI are advantageous for imaging the lungs due to reduced susceptibility effects, increased transversal relaxation times, and lower specific absorption rates. The lower investment and operating costs may enable increased availability and sustainability. Combining modern sequences and computer-based image processing may expand beyond morphological imaging by providing spatially and temporally resolved functional examinations of the lung parenchyma without ionizing radiation. In critical scenarios, like screening and short-term follow-up examinations, and patients at risk, low-field MRI may bridge the gap. These indications may include acute and chronic pulmonary diseases in pediatric patients and suspected pulmonary embolisms in pregnant women.


Assuntos
Pneumopatias , Imageamento por Ressonância Magnética , Criança , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Pulmão/diagnóstico por imagem , Pulmão/patologia , Pneumopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Gravidez , Tórax
5.
Pediatr Radiol ; 50(9): 1240-1248, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32556576

RESUMO

BACKGROUND: Radiation dose at CT should be as low as possible without compromising diagnostic quality. OBJECTIVE: To assess the potential for maximum dose reduction of pediatric lung dual-source CT with spectral shaping and advanced iterative reconstruction (ADMIRE). MATERIALS AND METHODS: We retrospectively analyzed dual-source CT acquisitions in a full-dose group (FD: 100 kV, 64 reference mAs) and in three groups with spectral shaping and differing reference mAs values (Sn: 100 kV, 96/64/32 reference mAs), each group consisting of 16 patients (age mean 11.5 years, standard deviation 4.8 years, median 12.8 years, range 1.3-18 years). Advanced iterative reconstruction of images was performed with different strengths (FD: ADMIRE Level 2; Sn: ADMIRE Levels 2, 3 and 4). We analyzed dose parameters and measured noise. Diagnostic confidence and detectability of lung lesions as well as anatomical structures were assessed using a Likert scale (from 1 [unacceptable] to 4 [fully acceptable]). RESULTS: Compared to full dose, effective dose was reduced to 16.7% in the Sn 96 group, 11.1% in Sn64, and 5.5% in Sn32 (P<0.001). Noise values of Sn64ADM4 did not statistically differ from those in FDADM2 (45.7 vs. 38.9 Hounsfield units [HU]; P=0.132), whereas noise was significantly higher in Sn32ADM4 compared to Sn64ADM4 (61.5 HU; P<0.001). A Likert score >3 was reached in Sn64ADM4 regarding diagnostic confidence (3.2) and detectability of lung lesions (3.3). For detectability of most anatomical structures, no significant differences were found between FDAM2 and Sn64ADM4 (P≥0.05). CONCLUSION: In pediatric lung dual-source CT, spectral shaping together with ADMIRE 4 enable radiation dose reduction to about 10% of a full-dose protocol while maintaining an acceptable diagnostic quality.


Assuntos
Pneumopatias/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X/métodos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos
6.
J Sports Sci Med ; 17(3): 392-401, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30116112

RESUMO

Delayed-onset muscle soreness (DOMS), an ultrastructural muscle injury, is one of the most common reasons for impaired muscle performance. The purpose of this study was to investigate the influence of sport compression garments on the development of exercise-induced intramuscular edema in the context of DOMS. DOMS was induced in 15 healthy participants. The participants performed a standardized eccentric exercise of the calf muscles. Magnetic resonance imaging (MRI) was performed at baseline and 60h after exercise (T2-weighted signal intensity and T2 relaxation time was evaluated in each compartment and the intramuscular edema in the medial head of the gastrocnemius muscle was segmented). After the exercise, a conventional compression garment (18-21 mmHg) was placed on one randomized calf for 60h. The level of muscle soreness was evaluated using a visual analogue pain scale. T2-weighted signal intensity, T2 relaxation time and intramuscular edema showed a significant interaction for time with increased signal intensities/intramuscular edema in the medial head of the gastrocnemius muscle at follow-up compared to baseline. No significant main effect for compression or interaction between time and limb occurred. Further, no significant differences in the soleus muscle and the lateral head of the gastrocnemius muscle were noted between limbs or over time. After exercise, there was significantly increased muscle soreness in both lower legs in resting condition and when going downstairs and a decreased range of motion in the ankle joint. No significant difference was observed between the compressed and the non-compressed calf. Our results indicate that wearing conventional compression garments after DOMS has been induced has no significant effect on the development of muscle edema, muscle soreness, range of motion and calf circumference.


Assuntos
Edema/prevenção & controle , Músculo Esquelético/lesões , Mialgia/prevenção & controle , Meias de Compressão , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Medição da Dor , Amplitude de Movimento Articular , Adulto Jovem
7.
Neuroradiology ; 59(2): 169-176, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28091696

RESUMO

INTRODUCTION: Spectral shaping aims to narrow the X-ray spectrum of clinical CT. The aim of this study was to determine the image quality and the extent of radiation dose reduction that can be achieved by tin prefiltration for parasinus CT. METHODS: All scans were performed with a third generation dual-source CT scanner. A study protocol was designed using 100 kV tube voltage with tin prefiltration (200 mAs) that provides image noise levels comparable to a low-dose reference protocol using 100 kV without spectral shaping (25 mAs). One hundred consecutive patients were prospectively enrolled and randomly assigned to the study or control group. All patients signed written informed consent. The study protocol was approved by the local Institutional Review Board and applies to the HIPAA. Subjective and objective image quality (attenuation values, image noise, and contrast-to-noise ratio (CNR)) were assessed. Radiation exposure was assessed as volumetric CT dose index, and effective dose was estimated. Mann-Whitney U test was performed for radiation exposure and for image noise comparison. RESULTS: All scans were of diagnostic image quality. Image noise in air, in the retrobulbar fat, and in the eye globe was comparable between both groups (all p > 0.05). CNReye globe/air did not differ significantly between both groups (p = 0.7). Radiation exposure (1.7 vs. 2.1 mGy, p < 0.01) and effective dose (0.055 vs. 0.066 mSv, p < 0.01) were significantly reduced in the study group. CONCLUSION: Radiation dose can be further reduced by 17% for low-dose parasinus CT by tin prefiltration maintaining diagnostic image quality.


Assuntos
Doenças dos Seios Paranasais/diagnóstico por imagem , Doses de Radiação , Proteção Radiológica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Método de Monte Carlo , Estanho
8.
Radiology ; 277(2): 406-12, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26225451

RESUMO

PURPOSE: To evaluate the ability of magnetic resonance (MR) imaging to induce deoxyribonucleic acid (DNA) damage in patients who underwent cardiac MR imaging in daily routine by using γ-H2AX immunofluorescence microscopy. MATERIALS AND METHODS: This study complies with the Declaration of Helsinki and was performed according to local ethics committee approval. Informed patient consent was obtained. Blood samples from 45 patients (13 women, 32 men; mean age, 50.3 years [age range, 20-89 years]) were obtained before and after contrast agent-enhanced cardiac MR imaging. MR imaging-induced double-strand breaks (DSBs) were quantified in isolated blood lymphocytes by using immunofluorescence microscopy after staining the phosphorylated histone variant γ-H2AX. Twenty-nine patients were examined with a myocarditis protocol (group A), 10 patients with a stress-testing protocol (group B), and six patients with flow measurements and angiography (group C). Paired t test was performed to compare excess foci before and after MR imaging. RESULTS: The mean baseline DSB level before MR imaging and 5 minutes after MR imaging was, respectively, 0.116 DSB per cell ± 0.019 (standard deviation) and 0.117 DSB per cell ± 0.019 (P = .71). There was also no significant difference in DSBs in these subgroups (group A: DSB per cell before and after MR imaging, respectively, 0.114 and 0.114, P = .91; group B: DSB per cell before and after MR imaging, respectively, 0.123 and 0.124, P = .78; group C: DSB per cell before and after MR imaging, respectively, 0.114 and 0.115, P = .36). CONCLUSION: By using γ-H2AX immunofluorescence microscopy, no DNA DSBs were detected after cardiac MR imaging.


Assuntos
Quebras de DNA de Cadeia Dupla , Cardiopatias/diagnóstico , Linfócitos , Imageamento por Ressonância Magnética , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Masculino , Microscopia de Fluorescência , Pessoa de Meia-Idade
9.
Neuroradiology ; 56(9): 797-803, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24961883

RESUMO

INTRODUCTION: Low tube voltage allows for computed tomography (CT) imaging with increased iodine contrast at reduced radiation dose. We sought to evaluate the image quality and potential dose reduction using a combination of attenuation based tube current modulation (TCM) and automated tube voltage adaptation (TVA) between 100 and 120 kV in CT of the head and neck. METHODS: One hundred thirty consecutive patients with indication for head and neck CT were examined with a 128-slice system capable of TCM and TVA. Reference protocol was set at 120 kV. Tube voltage was reduced to 100 kV whenever proposed by automated analysis of the localizer. An additional small scan aligned to the jaw was performed at a fixed 120 kV setting. Image quality was assessed by two radiologists on a standardized Likert-scale and measurements of signal- (SNR) and contrast-to-noise ratio (CNR). Radiation dose was assessed as CTDIvol. RESULTS: Diagnostic image quality was excellent in both groups and did not differ significantly (p = 0.34). Image noise in the 100 kV data was increased and SNR decreased (17.8/9.6) in the jugular veins and the sternocleidomastoid muscle when compared to 120 kV (SNR 24.4/10.3), but not in fatty tissue and air. However, CNR did not differ statistically significant between 100 (23.5/14.4/9.4) and 120 kV data (24.2/15.3/8.6) while radiation dose was decreased by 7-8%. CONCLUSIONS: TVA between 100 and 120 kV in combination with TCM led to a radiation dose reduction compared to TCM alone, while keeping CNR constant though maintaining diagnostic image quality.


Assuntos
Eletricidade , Cabeça/diagnóstico por imagem , Pescoço/diagnóstico por imagem , Tomografia Computadorizada por Raios X/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação
10.
Invest Radiol ; 59(3): 215-222, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37490031

RESUMO

OBJECTIVES: The aim of this study was to evaluate the accuracy of modern low-field magnetic resonance imaging (MRI) for lung nodule detection and to correlate nodule size measurement with computed tomography (CT) as reference. MATERIALS AND METHODS: Between November 2020 and July 2021, a prospective clinical trial using low-field MRI at 0.55 T was performed in patients with known pulmonary nodules from a single academic medical center. Every patient underwent MRI and CT imaging on the same day. The primary aim was to evaluate the detection accuracy of pulmonary nodules using MRI with transversal periodically rotated overlapping parallel lines with enhanced reconstruction in combination with coronal half-Fourier acquired single-shot turbo spin-echo MRI sequences. The secondary outcome was the correlation of the mean lung nodule diameter with CT as reference according to the Lung Imaging Reporting and Data System. Nonparametric Mann-Whitney U test, Spearman rank correlation coefficient, and Bland-Altman analysis were applied to analyze the results. RESULTS: A total of 46 participants (mean age ± SD, 66 ± 11 years; 26 women) were included. In a blinded analysis of 964 lung nodules, the detection accuracy was 100% for those ≥6 mm (126/126), 80% (159/200) for those ≥4-<6 mm, and 23% (147/638) for those <4 mm in MRI compared with reference CT. Spearman correlation coefficient of MRI and CT size measurement was r = 0.87 ( P < 0.001), and the mean difference was 0.16 ± 0.9 mm. CONCLUSIONS: Modern low-field MRI shows excellent accuracy in lesion detection for lung nodules ≥6 mm and a very strong correlation with CT imaging for size measurement, but could not compete with CT in the detection of small nodules.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Humanos , Feminino , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
11.
Invest Radiol ; 59(3): 223-229, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37493286

RESUMO

OBJECTIVES: Temporomandibular disorders (TMDs) are common and may cause persistent functional limitations and pain. Magnetic resonance imaging (MRI) at 1.5 and 3 T is commonly applied for the evaluation of the temporomandibular joint (TMJ). No evidence is available regarding the feasibility of modern low-field MRI for the assessment of TMDs. The objective of this prospective study was to evaluate the image quality (IQ) of 0.55 T MRI in direct comparison with 1.5 T MRI. MATERIALS AND METHODS: Seventeen patients (34 TMJs) with suspected intraarticular TMDs were enrolled, and both 0.55 and 1.5 T MRI were performed on the same day. Two senior readers independently evaluated the IQ focusing on the conspicuity of disc morphology (DM), disc position (DP), and osseous joint morphology (OJM) for each joint. We analyzed the IQ and degree of artifacts using a 4-point Likert scale (LS) at both field strengths. A fully sufficient IQ was defined as an LS score of ≥3. Nonparametric Wilcoxon test for related samples was used for statistical comparison. RESULTS: The median IQ for the DM and OJM at 0.55 T was inferior to that at 1.5 T (DM: 3 [interquartile range {IQR}, 3-4] vs 4 [IQR, 4-4]; OJM: 3 [IQR, 3-4] vs 4 [IQR 4-4]; each P < 0.001). For DP, the IQ was comparable (4 [IQR 3-4] vs 4 [IQR 4-4]; P > 0.05). A sufficient diagnostic IQ was maintained for the DM, DP, and OJM in 92% of the cases at 0.55 T and 100% at 1.5 T. Minor image artifacts (LS score of ≥3) were more prevalent at 0.55 T (29%) than at 1.5 T (12%). CONCLUSIONS: Magnetic resonance imaging of the TMJ at 0.55 T yields a lower IQ than does MRI at 1.5 T but maintains sufficient diagnostic confidence in the majority of patients. Further improvements are needed for reliable clinical application.


Assuntos
Disco da Articulação Temporomandibular , Transtornos da Articulação Temporomandibular , Humanos , Disco da Articulação Temporomandibular/patologia , Estudos Prospectivos , Articulação Temporomandibular/anatomia & histologia , Articulação Temporomandibular/patologia , Transtornos da Articulação Temporomandibular/diagnóstico por imagem , Transtornos da Articulação Temporomandibular/patologia , Imageamento por Ressonância Magnética/métodos
12.
Eur J Radiol ; 176: 111534, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38820951

RESUMO

PURPOSE: Radiological reporting is transitioning to quantitative analysis, requiring large-scale multi-center validation of biomarkers. A major prerequisite and bottleneck for this task is the voxelwise annotation of image data, which is time-consuming for large cohorts. In this study, we propose an iterative training workflow to support and facilitate such segmentation tasks, specifically for high-resolution thoracic CT data. METHODS: Our study included 132 thoracic CT scans from clinical practice, annotated by 13 radiologists. In three iterative training experiments, we aimed to improve and accelerate segmentation of the heart and mediastinum. Each experiment started with manual segmentation of 5-25 CT scans, which served as training data for a nnU-Net. Further iterations incorporated AI pre-segmentation and human correction to improve accuracy, accelerate the annotation process, and reduce human involvement over time. RESULTS: Results showed consistent improvement in AI model quality with each iteration. Resampled datasets improved the Dice similarity coefficients for both the heart (DCS 0.91 [0.88; 0.92]) and the mediastinum (DCS 0.95 [0.94; 0.95]). Our AI models reduced human interaction time by 50 % for heart and 70 % for mediastinum segmentation in the most potent iteration. A model trained on only five datasets achieved satisfactory results (DCS > 0.90). CONCLUSIONS: The iterative training workflow provides an efficient method for training AI-based segmentation models in multi-center studies, improving accuracy over time and simultaneously reducing human intervention. Future work will explore the use of fewer initial datasets and additional pre-processing methods to enhance model quality.


Assuntos
Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Inteligência Artificial , Mediastino/diagnóstico por imagem , Coração/diagnóstico por imagem
13.
Insights Imaging ; 15(1): 258, 2024 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-39466506

RESUMO

OBJECTIVES: In this multi-center study, we proposed a structured reporting (SR) framework for non-small cell lung cancer (NSCLC) and developed a software-assisted tool to automatically translate image-based findings and annotations into TNM classifications. The aim of this study was to validate the software-assisted SR tool for NSCLC, assess its potential clinical impact in a proof-of-concept study, and evaluate current reporting standards in participating institutions. METHODS: A framework for SR and staging of NSCLC was developed in a multi-center collaboration. SR annotations and descriptions were used to generate semi-automated TNM classification. The SR and TNM classification tools were evaluated by nine radiologists on n = 20 representative [18F]FDG PET/CT studies and compared to the free text reporting (FTR) strategy. Results were compared to a multidisciplinary team reference using a generalized linear mixed model (GLMM). Additionally, participants were surveyed on their experience with SR and TNM classification. RESULTS: Overall, GLMM analysis revealed that readers using SR were 1.707 (CI: 1.137-2.585) times more likely to correctly classify TNM status compared to FTR strategy (p = 0.01) resulting in increased overall TNM correctness in 71.9% (128/178) of cases compared to 62.8% (113/180) FTR. The primary source of variation in classification accuracy was explained by case complexity. Participants rated the potential impact of SR and semi-automated TNM classification as positive across all categories with improved scores after template validation. CONCLUSION: This multi-center study yielded an effective software-assisted SR framework for NSCLC. The SR and semi-automated classification tool improved TNM classification and were perceived as valuable. CRITICAL RELEVANCE STATEMENT: Software-assisted SR provides robust input for semi-automated rule-based TNM classification in non-small-cell lung carcinoma (NSCLC), improves TNM correctness compared to FTR, and was perceived as valuable by radiology physicians. KEY POINTS: SR and TNM classification are underutilized across participating centers for NSCLC staging. Software-assisted SR has emerged as a promising strategy for oncologic assessment. Software-assisted SR facilitates semi-automated TNM classification with improved staging accuracy compared to free-text reports in NSCLC.

14.
Clin Case Rep ; 11(5): e7349, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37215974

RESUMO

Key Clinical Message: Complex presentations of MCS patients may necessitate a multidisciplinary approach involving HF cardiologists, CT surgeons, advanced cardiac imagers, and interventional cardiologists in order to define the optimal management strategy. Abstract: Left ventricle assist devices (LVADs) provide life-sustaining treatment for patients with terminal heart failure, but their intricacy allows for complications. One complication is LVAD outflow graft obstruction due to the graft's intraluminal thrombus or extraluminal compression. It may be treated endovascularly with stenting. We report an endovascular stenting of an outflow tract in HVAD™ (HeartWare Inc.) due to a pseudoaneurysm causing compression and kinking stenosis.

15.
Eur J Radiol ; 167: 111078, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37688917

RESUMO

OBJECTIVES: This study evaluates the impact of a scanner-integrated, customized clinical decision support system (CDSS) on the acquisition technique, scan range, and reconstruction in thoracoabdominal CT. MATERIALS AND METHODS: We applied CDSS in contrast-enhanced examinations of the trunk with various clinical indications on a recent scanner with the capability of dual-energy CT (DECT), anatomic landmark detection (ALD), and iterative metal-artifact reduction (MAR). Simple and comprehensive questions about the patient's breath hold capability, the anatomical region of interest, and metal implants can be answered after the localizer. The acquisition technique (single energy, SECT, or dual energy), scan range (chest-abdomen-pelvis or chest-abdomen), and reconstruction technique (with or without MAR) were then automatically adapted in the examination protocols in coherence with these selections. Retrospectively, we compared the usage rates for these techniques in 624 examinations on the study scanner with 740 examinations on a comparable scanner without CDSS. Subgroup analysis of effective dose (ED), scan duration, and image quality (IQ) was performed in the study group. RESULTS: CDSS leads to an increased usage rate of DECT (64.4% vs. 2.8%) and MAR (75.4% vs. 44.0%). All scan range adaptations by ALD were successful. The resulting subjective IQ between single energy and DECT acquisitions was comparable (all p > 0.05). Scan duration was significantly longer in DECT than in SECT (16.9 s vs. 6.5 s; p < 0.001). However, the objective IQ was significantly higher in DECT (CNRD 2.1 vs. 1.8; p < 0.01), and the ED significantly lower (6.7 mSv vs. 7.6 mSv; p = 0.004). CONCLUSION: CDSS for thoracoabdominal CT leads to a substantially increased usage rate of innovative techniques during acquisition and reconstruction. Patients with adapted protocols benefit from improved image quality and increased post-processing options at lower radiation doses.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Humanos , Estudos Retrospectivos , Pontos de Referência Anatômicos , Suspensão da Respiração , Tomografia Computadorizada por Raios X
16.
J Cardiothorac Surg ; 18(1): 60, 2023 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-36739433

RESUMO

BACKGROUND: Pericardial tamponade (PT) early after cardiac surgery is a challenging clinical entity, not infrequently misrecognized and often only detected late in its course. Because the clinical signs of pericardial tamponade can be very unspecific, a high degree of initial suspicion is required to establish the diagnosis. In addition to clinical examination the deployment of imaging techniques is almost always mandatory in order to avoid delays in diagnosis and to initiate any necessary interventions, such as pericardiocentesis or direct cardiac surgical interventions. After a brief overview of how knowledge of PT has developed throughout history, we report on an atypical life-threatening cardiac tamponade after cardiac surgery. A 74-year-old woman was admitted for elective biological aortic valve replacement and aorto-coronary-bypass grafting (left internal mammary artery to left anterior descending artery, single vein graft to right coronary artery). On the 10th postoperative day, the patient unexpectedly deteriorated. She rapidly developed epigastric pain radiating to the left upper abdomen, and features of low peripheral perfusion and shock. There were no clear signs of pericardial tamponade either clinically or echocardiographically. Therefore, for further differential diagnosis, a contrast-enhanced computed tomography scan was performed under clinical suspicion of acute abdomen. Unexpectedly, active bleeding distally from the right coronary anastomosis was revealed. While the patient was prepared for operative revision, she needed cardiopulmonary resuscitation, which was successful. Intraoperatively, the source of bleeding was located and surgically relieved. The subsequent postoperative course was uneventful. CONCLUSIONS: In the first days after cardiac surgery, the occurrence of life-threatening situations, such as cardiac tamponade, must be expected. Especially if the symptoms are atypical, the entire diagnostic armamentarium must be applied to identify the origin of the complaints, which may be cardiac, but also non-cardiac. CENTRAL MESSAGE: A high level of suspicion, immediate diagnostic confirmation, and rapid treatment are required to recognize and successfully treat such an emergency (Fig. 5). PERSPECTIVE: Pericardial tamponade should always be considered as a complication of cardiac surgery, even when symptoms are atypical. The full range of diagnostic tools must be used to identify the origin of the complaints, which may be cardiac, but also non-cardiac (Fig. 5).


Assuntos
Procedimentos Cirúrgicos Cardíacos , Tamponamento Cardíaco , Feminino , Humanos , Idoso , Tamponamento Cardíaco/diagnóstico , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/cirurgia , Pericardiocentese/efeitos adversos , Coração , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Tomografia Computadorizada por Raios X/efeitos adversos
17.
Eur J Radiol ; 165: 110927, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37379624

RESUMO

OBJECTIVES: Vestibular schwannoma (VS) is the most common mass of the internal auditory canal (IAC) and is responsible for unilateral sensorineural hearing loss. Magnetic resonance imaging (MRI) at 1.5 T and 3 T is the standard of care for the evaluation of VS, and the feasibility of using modern low-field MRI for imaging of the IAC has not yet been elucidated. Hence, the purpose of this prospective study was to assess image quality and diagnostic performance of a modern 0.55 T MRI. MATERIALS AND METHODS: Fifty-six patients with known unilateral VS underwent routine MRI of the IAC at 1.5 T, followed immediately by 0.55 T MRI. Two radiologists independently evaluated the image quality, conspicuity of VS, diagnostic confidence, and image artifacts separately for isotropic T2-weighted SPACE images and for transversal and coronal T1-weighted fat-saturated contrast-enhanced images at 1.5 T and 0.55 T using 5-point Likert scales. In a second independent reading, both readers assessed lesion conspicuity and subjective diagnostic confidence in a direct comparison of 1.5 T and 0.55 T images. RESULTS: Image quality of transversal T1-weighted images (p = 0.13 and p = 0.16 for Reader 1 and Reader 2, respectively) and T2-weighted SPACE images (p = 0.39 and p = 0.58) were rated equally at 1.5 T and 0.55 T by both readers, whereas image quality of coronal T1-weighted images was superior at 1.5 T (p = 0.009 and p = 0.001). Analysis of the conspicuity of VS, diagnostic confidence, and image artifacts of all sequences revealed no significant differences between 1.5 T and 0.55 T. In the direct comparison of 1.5 T with 0.55 T images, there were no significant differences in lesion conspicuity or diagnostic confidence for any sequence (p = 0.60-0.73). CONCLUSIONS: Modern low-field MRI at 0.55 T provided a sufficient diagnostic image quality and seems feasible for the evaluation of VS of the IAC.


Assuntos
Neuroma Acústico , Humanos , Neuroma Acústico/diagnóstico por imagem , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Artefatos , Meios de Contraste
18.
Invest Radiol ; 58(3): 216-222, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36165876

RESUMO

OBJECTIVES: Presurgical identification and morphologic characterization of the peroneal perforator arteries (PPAs) are essential for osseomyocutaneous flap surgery. The aim of this study was to evaluate PPAs using time-of-flight (TOF) angiography in 7 T magnetic resonance imaging in comparison with dual-energy computed tomographic angiography (CTA). MATERIALS AND METHODS: In this prospective study, TOF angiography and CTA of both lower legs were acquired before flap surgery from 07/2019 to 02/2020. Magnetic resonance imaging was performed using a dedicated 28-channel knee coil with an acquisition time of 9:55 minutes (voxel size: 0.4 × 0.4 × 0.8 mm). Computed tomographic angiography was acquired with a third-generation dual-source computed tomography on the same day. Virtual monoenergetic reconstructions at 40 keV photon energy served as the standard of reference for PPA identification and subtyping. Two independent readers assessed the image quality, quantity, length assessment, and classification according to surgical considerations of PPAs for TOF angiography and CTA. Both TOF angiography and CTA were used for presurgical flap design and were evaluated by an orofacial surgeon. RESULTS: Ten patients (mean age, 59.9 ± 14.9 years; 7 men) were included. Time-of-flight angiography and CTA identified 53 and 51 PPAs in total, respectively. Time-of-flight angiography showed superior image quality (both readers, P < 0.05). Time-of-flight angiography enabled specific classification of PPA subtypes more often (53 vs 39; P < 0.05), and both readers reported higher diagnostic confidence for TOF angiography than CTA in all patients (interrater agreement κ = 0.8; P < 0.05). Regarding length assessment, PPAs were significantly more conspicuous with TOF angiography (TOF mean , 50 ± 11 mm; CTA mean , 40 ± 9 mm; P = 0.001). In comparison with CTA, TOF angiography prospectively changed the orofacial surgeon's final decision on the presurgical selected PPAs in 60% of cases. CONCLUSIONS: Presurgical assessment of PPAs is feasible using TOF in 7 T magnetic resonance imaging. Moreover, TOF angiography was superior to CTA for classifying and identifying PPAs, which may facilitate the planning of reconstructive surgery.


Assuntos
Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Angiografia por Ressonância Magnética/métodos , Estudos Prospectivos , Angiografia por Tomografia Computadorizada/métodos , Artérias
19.
Eur J Nucl Med Mol Imaging ; 39(11): 1712-9, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22854986

RESUMO

PURPOSE: The purpose of this study was to evaluate DNA double-strand breaks (DSBs) in blood lymphocytes of patients undergoing positron emission tomography (PET)/CT using γ-H2AX immunofluorescence microscopy and to differentiate between (18)F-fluorodeoxyglucose (FDG) and CT-induced DNA lesions. METHODS: This study was approved by the local Ethics Committee and complies with Health Insurance Portability and Accountability Act (HIPAA) requirements. After written informed consent was obtained, 33 patients underwent whole-body (18)F-FDG PET/CT (3 MBq/kg body weight, 170/100 reference mAs at 120 kV). The FDG PET and CT portions were performed as an initial CT immediately followed by the PET. Blood samples were obtained before, at various time points following (18)F-FDG application and up to 24 h after the CT scan. Distinct foci representing DSBs were quantified in isolated lymphocytes using fluorescence microscopy after staining against the phosphorylated histone variant γ-H2AX. RESULTS: The DSB values at the various time points were significantly different (p < 0.001). The median baseline level was 0.08/cell (range 0.06-0.12/cell). Peaks of radiation-induced DSBs were found 30 min after (18)F-FDG administration (median excess foci 0.11/cell, range 0.06-0.27/cell) and 5 min after CT (median excess foci 0.17/cell, range 0.05-0.54/cell). A significant correlation between CT-induced DSBs and dose length product was obtained (ρ = 0.898, p < 0.001). After 24 h DSB values were still slightly but significantly elevated (median foci 0.11/cell, range 0.10-0.14/cell, p = 0.003) compared to pre-exposure levels. CONCLUSION: PET/CT-induced DSBs can be monitored using γ-H2AX immunofluorescence microscopy. Peak values may be obtained 30 min after (18)F-FDG injection and 5 min after CT. The radionuclide contributes considerably to the total DSB induction in this setting.


Assuntos
Quebras de DNA de Cadeia Dupla , Reparo do DNA , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluordesoxiglucose F18 , Histonas/metabolismo , Humanos , Linfócitos/efeitos da radiação , Masculino , Microscopia de Fluorescência , Pessoa de Meia-Idade , Fosforilação
20.
Eur Radiol ; 22(3): 569-78, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21984448

RESUMO

OBJECTIVES: To evaluate radiation dose levels in patients undergoing spiral coronary computed tomography angiography (CTA) on a dual-source system in clinical routine. METHODS: Coronary CTA was performed for 56 patients with electrocardiogram-triggered tube current modulation (TCM) and heart-rate (HR) dependent pitch adaptation. Individual Monte Carlo (MC) simulations were performed for dose assessment. Retrospective simulations with constant tube current (CTC) served as reference. Lung tissue was segmented and used for organ and effective dose (ED) calculation. RESULTS: Estimates for mean relative ED was 7.1 ± 2.1 mSv/100 mAs for TCM and 12.5 ± 5.3 mSv/100 mAs for CTC (P < 0.001). Relative dose reduction at low HR (≤60 bpm) was highest (49 ± 5%) compared to intermediate (60-70 bpm, 33 ± 12%) and high HR (>70 bpm, 29 ± 12%). However lowest ED is achieved at high HR (5.2 ± 1.5 mSv/100 mAs), compared with intermediate (6.7 ± 1.6 mSv/100 mAs) and low (8.3 ± 2.1 mSv/100 mAs) HR when automated pitch adaptation is applied. CONCLUSIONS: Radiation dose savings up to 52% are achievable by TCM at low and regular HR. However lowest ED is attained at high HR by pitch adaptation despite inferior radiation dose reduction by TCM. KEY POINTS: • Monte Carlo simulations allow for individual radiation dose calculations. • ECG-triggered tube current modulation (TCM) can effectively reduce radiation dose. • Slow and regular heart rates allow for highest dose reductions by TCM. • Adaptive pitch accounts for lowest radiation dose at high heart rates. • Women receive higher effective dose than men undergoing spiral coronary CT-angiography.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Método de Monte Carlo , Doses de Radiação , Radiometria/métodos , Tomografia Computadorizada Espiral/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Eletrocardiografia , Feminino , Humanos , Iopamidol/análogos & derivados , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores Sexuais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA