Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Med Internet Res ; 23(7): e26151, 2021 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-34255661

RESUMO

BACKGROUND: Over half a million individuals are diagnosed with head and neck cancer each year globally. Radiotherapy is an important curative treatment for this disease, but it requires manual time to delineate radiosensitive organs at risk. This planning process can delay treatment while also introducing interoperator variability, resulting in downstream radiation dose differences. Although auto-segmentation algorithms offer a potentially time-saving solution, the challenges in defining, quantifying, and achieving expert performance remain. OBJECTIVE: Adopting a deep learning approach, we aim to demonstrate a 3D U-Net architecture that achieves expert-level performance in delineating 21 distinct head and neck organs at risk commonly segmented in clinical practice. METHODS: The model was trained on a data set of 663 deidentified computed tomography scans acquired in routine clinical practice and with both segmentations taken from clinical practice and segmentations created by experienced radiographers as part of this research, all in accordance with consensus organ at risk definitions. RESULTS: We demonstrated the model's clinical applicability by assessing its performance on a test set of 21 computed tomography scans from clinical practice, each with 21 organs at risk segmented by 2 independent experts. We also introduced surface Dice similarity coefficient, a new metric for the comparison of organ delineation, to quantify the deviation between organ at risk surface contours rather than volumes, better reflecting the clinical task of correcting errors in automated organ segmentations. The model's generalizability was then demonstrated on 2 distinct open-source data sets, reflecting different centers and countries to model training. CONCLUSIONS: Deep learning is an effective and clinically applicable technique for the segmentation of the head and neck anatomy for radiotherapy. With appropriate validation studies and regulatory approvals, this system could improve the efficiency, consistency, and safety of radiotherapy pathways.


Assuntos
Aprendizado Profundo , Neoplasias de Cabeça e Pescoço , Algoritmos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Tomografia Computadorizada por Raios X
2.
Radiother Oncol ; 200: 110513, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39222848

RESUMO

BACKGROUND AND PURPOSE: Over the past decade, tools for automation of various sub-tasks in radiotherapy planning have been introduced, such as auto-contouring and auto-planning. The purpose of this study was to benchmark what degree of automation is possible. MATERIALS AND METHODS: A challenge to perform automated treatment planning for prostate and prostate bed radiotherapy was set up. Participants were provided with simulation CTs and a treatment prescription and were asked to use automated tools to produce a deliverable radiotherapy treatment plan with as little human intervention as possible. Plans were scored for their adherence to the protocol when assessed using consensus expert contours. RESULTS: Thirteen entries were received. The top submission adhered to 81.8% of the minimum objectives across all cases using the consensus contour, meeting all objectives in one of the ten cases. The same system met 89.5% of objectives when assessed with their own auto-contours, meeting all objectives in four of the ten cases. The majority of systems used in the challenge had regulatory clearance (Auto-contouring: 82.5%, Auto-planning: 77%). Despite the 'hard' rule that participants should not check or edit contours or plans, 69% reported looking at their results before submission. CONCLUSIONS: Automation of the full planning workflow from simulation CT to deliverable treatment plan is possible for prostate and prostate bed radiotherapy. While many generated plans were found to require none or minor adjustment to be regarded as clinically acceptable, the result indicated there is still a lack of trust in such systems preventing full automation.


Assuntos
Neoplasias da Próstata , Planejamento da Radioterapia Assistida por Computador , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Neoplasias da Próstata/radioterapia , Masculino , Automação , Tomografia Computadorizada por Raios X/métodos , Dosagem Radioterapêutica
3.
Radiother Oncol ; 186: 109747, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37330053

RESUMO

BACKGROUND AND PURPOSE: To date, data used in the development of Deep Learning-based automatic contouring (DLC) algorithms have been largely sourced from single geographic populations. This study aimed to evaluate the risk of population-based bias by determining whether the performance of an autocontouring system is impacted by geographic population. MATERIALS AND METHODS: 80 Head Neck CT deidentified scans were collected from four clinics in Europe (n = 2) and Asia (n = 2). A single observer manually delineated 16 organs-at-risk in each. Subsequently, the data was contoured using a DLC solution, and trained using single institution (European) data. Autocontours were compared to manual delineations using quantitative measures. A Kruskal-Wallis test was used to test for any difference between populations. Clinical acceptability of automatic and manual contours to observers from each participating institution was assessed using a blinded subjective evaluation. RESULTS: Seven organs showed a significant difference in volume between groups. Four organs showed statistical differences in quantitative similarity measures. The qualitative test showed greater variation in acceptance of contouring between observers than between data from different origins, with greater acceptance by the South Korean observers. CONCLUSION: Much of the statistical difference in quantitative performance could be explained by the difference in organ volume impacting the contour similarity measures and the small sample size. However, the qualitative assessment suggests that observer perception bias has a greater impact on the apparent clinical acceptability than quantitatively observed differences. This investigation of potential geographic bias should extend to more patients, populations, and anatomical regions in the future.


Assuntos
Aprendizado Profundo , Humanos , Tomografia Computadorizada por Raios X , Algoritmos , Variações Dependentes do Observador , Europa (Continente) , Órgãos em Risco , Planejamento da Radioterapia Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA