Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 134
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Magn Reson ; 19(1): 9, 2017 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-28122618

RESUMO

BACKGROUND: Knowledge of the three-dimensional (3D) infarct structure and fiber orientation remodeling is essential for complete understanding of infarct pathophysiology and post-infarction electromechanical functioning of the heart. Accurate imaging of infarct microstructure necessitates imaging techniques that produce high image spatial resolution and high signal-to-noise ratio (SNR). The aim of this study is to provide detailed reconstruction of 3D chronic infarcts in order to characterize the infarct microstructural remodeling in porcine and human hearts. METHODS: We employed a customized diffusion tensor imaging (DTI) technique in conjunction with late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) on a 3T clinical scanner to image, at submillimeter resolution, myofiber orientation and scar structure in eight chronically infarcted porcine hearts ex vivo. Systematic quantification of local microstructure was performed and the chronic infarct remodeling was characterized at different levels of wall thickness and scar transmurality. Further, a human heart with myocardial infarction was imaged using the same DTI sequence. RESULTS: The SNR of non-diffusion-weighted images was >100 in the infarcted and control hearts. Mean diffusivity and fractional anisotropy (FA) demonstrated a 43% increase, and a 35% decrease respectively, inside the scar tissue. Despite this, the majority of the scar showed anisotropic structure with FA higher than an isotropic liquid. The analysis revealed that the primary eigenvector orientation at the infarcted wall on average followed the pattern of original fiber orientation (imbrication angle mean: 1.96 ± 11.03° vs. 0.84 ± 1.47°, p = 0.61, and inclination angle range: 111.0 ± 10.7° vs. 112.5 ± 6.8°, p = 0.61, infarcted/control wall), but at a higher transmural gradient of inclination angle that increased with scar transmurality (r = 0.36) and the inverse of wall thickness (r = 0.59). Further, the infarcted wall exhibited a significant increase in both the proportion of left-handed epicardial eigenvectors, and in the angle incoherency. The infarcted human heart demonstrated preservation of primary eigenvector orientation at the thinned region of infarct, consistent with the findings in the porcine hearts. CONCLUSIONS: The application of high-resolution DTI and LGE-CMR revealed the detailed organization of anisotropic infarct structure at a chronic state. This information enhances our understanding of chronic post-infarction remodeling in large animal and human hearts.


Assuntos
Meios de Contraste/administração & dosagem , Imagem de Tensor de Difusão , Gadolínio DTPA/administração & dosagem , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico por imagem , Idoso de 80 Anos ou mais , Animais , Anisotropia , Doença Crônica , Modelos Animais de Doenças , Feminino , Fibrose , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Miocárdio/patologia , Valor Preditivo dos Testes , Sus scrofa , Remodelação Ventricular
2.
Magn Reson Med ; 76(2): 663-78, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26479724

RESUMO

PURPOSE: Analytical phantoms have closed form Fourier transform expressions and are used to simulate MRI acquisitions. Existing three-dimensional (3D) analytical phantoms are unable to accurately model shapes of biomedical interest. The goal of this study was to demonstrate that polyhedral analytical phantoms have closed form Fourier transform expressions and can accurately represent 3D biomedical shapes. METHODS: The Fourier transform of a polyhedron was implemented and its accuracy in representing faceted and smooth surfaces was characterized. Realistic anthropomorphic polyhedral brain and torso phantoms were constructed and their use in simulated 3D and two-dimensional (2D) MRI acquisitions was described. RESULTS: Using polyhedra, the Fourier transform of faceted shapes can be computed to within machine precision. Smooth surfaces can be approximated with increasing accuracy by increasing the number of facets in the polyhedron; the additional accumulated numerical imprecision of the Fourier transform of polyhedra with many faces remained small. Simulations of 3D and 2D brain and 2D torso cine acquisitions produced realistic reconstructions free of high frequency edge aliasing compared with equivalent voxelized/rasterized phantoms. CONCLUSION: Analytical polyhedral phantoms are easy to construct and can accurately simulate shapes of biomedical interest. Magn Reson Med 76:663-678, 2016. © 2015 Wiley Periodicals, Inc.


Assuntos
Biomimética/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Biológicos , Imagens de Fantasmas , Animais , Simulação por Computador , Análise de Fourier , Humanos , Imageamento por Ressonância Magnética/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
J Magn Reson Imaging ; 41(2): 525-35, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24395498

RESUMO

PURPOSE: Image-guided treatment of low-flow vascular (venous or lymphatic) malformations presents a challenging visualization problem, regardless of the imaging modality being used for guidance. The purpose of this study was to employ a new magnetic resonance imaging (MRI) sequence, T2 -weighted interrupted balanced steady-state free precession (T2 W-iSSFP), for real-time image guidance of needle insertion. MATERIALS AND METHODS: T2 W-iSSFP uses variable flip angle balanced steady-state free precession (bSSFP, a.k.a. SSFP) to establish T2 -weighting and fat suppression. Swine (n = 3) and patients (n = 4, three female, all with venous malformations) were enrolled in the assessment. T2 -weighted turbo spin echo (T2 -TSE) with spectral adiabatic inversion recovery (SPAIR), SPAIR-T2 -TSE or T2 -TSE for short, was used as the reference. T2 -weighted half Fourier acquired single shot turbo spin echo (T2 -HASTE) with SPAIR (SPAIR-T2 -HASTE, T2 -HASTE for short), fat saturated bSSFP (FS-SSFP), and T2 W-iSSFP were imaged. Numeric metrics, namely, contrast-to-noise ratio (CNR) efficiency (CNR divided by the square root of acquisition time) and local sharpness (the reciprocal of edge width), were used to assess image quality. MR-guided sclerotherapy was performed on the same patients using real-time T2 W-iSSFP to guide needle insertion. RESULTS: Comparing the visualization of needles in the images of swine, the local sharpness (mm(-1) ) was: 0.21 ± 0.06 (T2 -HASTE), 0.48 ± 0.02 (FS-SSFP), and 0.49 ± 0.03 (T2 W-iSSFP). T2 W-iSSFP is higher than T2 -HASTE (P < 0.001). For the patient images, their CNR efficiencies were: 797 ± 66 (T2 -HASTE), 281 ± 44 (FS-SSFP), and 860 ± 29 (T2 W-iSSFP). T2 W-iSSFP is higher than FS-SSFP (P < 0.02). The frame rate of T2 W-iSSFP was 2.5-3.5 frames per second. All MR-guided sclerotherapy procedures were successful, with all needles (six punctures) placed in the targets. CONCLUSION: T2 W-iSSFP provides effective lesion identification and needle visualization. This new pulse sequence can be used for MR-guided sclerotherapy of low-flow vascular malformations. It may have potential use in other MR-guided procedures where heavily T2 -weighted real-time images are needed.


Assuntos
Imagem por Ressonância Magnética Intervencionista/métodos , Escleroterapia/métodos , Malformações Vasculares/terapia , Adulto , Animais , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Agulhas , Suínos
4.
J Cardiovasc Comput Tomogr ; 18(2): 170-178, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38242778

RESUMO

BACKGROUND: Lead placement at the latest mechanically activated left ventricle (LV) segments is strongly correlated with response to cardiac resynchronization therapy (CRT). We demonstrate the feasibility of a cardiac 4DCT motion correction algorithm (ResyncCT) in estimating LV mechanical activation for guiding lead placement in CRT. METHODS: Subjects with full cardiac cycle 4DCT images acquired using a wide-detector CT scanner for CRT planning/upgrade were included. 4DCT images exhibited motion artifact-induced false-dyssynchrony, hindering LV mechanical activation time estimation. Motion-corrupted images were processed with ResyncCT to yield motion-corrected images. Time to onset of shortening (TOS) was estimated in each of 72 endocardial segments. A false-dyssynchrony index (FDI) was used to quantify the extent of motion artifacts in the uncorrected and the ResyncCT images. After motion correction, the change in classification of LV free-wall segments as optimal target sites for lead placement was investigated. RESULTS: Twenty subjects (70.7 â€‹± â€‹13.9 years, 6 female) were analyzed. Motion artifacts in the ResyncCT-processed images were significantly reduced (FDI: 28.9 â€‹± â€‹9.3 â€‹% vs 47.0 â€‹± â€‹6.0 â€‹%, p â€‹< â€‹0.001). In 10 (50 â€‹%) subjects, ResyncCT motion correction yielded statistically different TOS estimates (p â€‹< â€‹0.05). Additionally, 43 â€‹% of LV free-wall segments were reclassified as optimal target sites for lead placement after motion correction. CONCLUSIONS: ResyncCT significantly reduced motion artifacts in wide-detector cardiac 4DCT images, yielded statistically different time to onset of shortening estimates, and changed the location of optimal target sites for lead placement. These results highlight the potential utility of ResyncCT motion correction in CRT planning when using wide-detector 4DCT imaging.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Feminino , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Valor Preditivo dos Testes , Coração , Ventrículos do Coração/diagnóstico por imagem , Resultado do Tratamento
5.
Med Phys ; 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38753583

RESUMO

BACKGROUND: Four-dimensional (4D) wide coverage computed tomography (CT) is an effective imaging modality for measuring the mechanical function of the myocardium. However, repeated CT measurement across a number of heartbeats is still a concern. PURPOSE: A projection-domain noise emulation method is presented to generate accurate low-dose (mA modulated) 4D cardiac CT scans from high-dose scans, enabling protocol optimization to deliver sufficient image quality for functional cardiac analysis while using a dose level that is as low as reasonably achievable (ALARA). METHODS: Given a targeted low-dose mA modulation curve, the proposed noise emulation method injects both quantum and electronic noise of proper magnitude and correlation to the high-dose data in projection domain. A spatially varying (i.e., channel-dependent) detector gain term as well as its calibration method were proposed to further improve the noise emulation accuracy. To determine the ALARA dose threshold, a straightforward projection domain image quality (IQ) metric was proposed that is based on the number of projection rays that do not fall under the non-linear region of the detector response. Experiments were performed to validate the noise emulation method with both phantom and clinical data in terms of visual similarity, contrast-to-noise ratio (CNR), and noise-power spectrum (NPS). RESULTS: For both phantom and clinical data, the low-dose emulated images exhibited similar noise magnitude (CNR difference within 2%), artifacts, and texture to that of the real low-dose images. The proposed channel-dependent detector gain term resulted in additional increase in emulation accuracy. Using the proposed IQ metric, recommended kVp and mA settings were calculated for low dose 4D Cardiac CT acquisitions for patients of different sizes. CONCLUSIONS: A detailed method to estimate system-dependent parameters for a raw-data based low dose emulation framework was described. The method produced realistic noise levels, artifacts, and texture with phantom and clinical studies. The proposed low-dose emulation method can be used to prospectively select patient-specific minimal-dose protocols for functional cardiac CT.

6.
ArXiv ; 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38560739

RESUMO

Background: Four-dimensional (4D) wide coverage computed tomography (CT) is an effective imaging modality for measuring the mechanical function of the myocardium. However, repeated CT measurement across a number of heartbeats is still a concern. Purpose: A projection-domain noise emulation method is presented to generate accurate low-dose (mA modulated) 4D cardiac CT scans from high-dose scans, enabling protocol optimization to deliver sufficient image quality for functional cardiac analysis while using a dose level that is as low as reasonably achievable (ALARA). Methods: Given a targeted low-dose mA modulation curve, the proposed noise emulation method injects both quantum and electronic noise of proper magnitude and correlation to the high-dose data in projection domain. A spatially varying (i.e., channel-dependent) detector gain term as well as its calibration method were proposed to further improve the noise emulation accuracy. To determine the ALARA dose threshold, a straightforward projection domain image quality (IQ) metric was proposed that is based on the number of projection rays that do not fall under the non-linear region of the detector response. Experiments were performed to validate the noise emulation method with both phantom and clinical data in terms of visual similarity, contrast-to-noise ratio (CNR), and noise-power spectrum (NPS). Results: For both phantom and clinical data, the low-dose emulated images exhibited similar noise magnitude (CNR difference within 2%), artifacts, and texture to that of the real low-dose images. The proposed channel-dependent detector gain term resulted in additional increase in emulation accuracy. Using the proposed IQ metric, recommended kVp and mA settings were calculated for low dose 4D Cardiac CT acquisitions for patients of different sizes. Conclusions: A detailed method to estimate system-dependent parameters for a raw-data based low dose emulation framework was described. The method produced realistic noise levels, artifacts, and texture with phantom and clinical studies. The proposed low-dose emulation method can be used to prospectively select patient-specific minimal-dose protocols for functional cardiac CT.

7.
J Biomech Eng ; 135(4): 044501, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24231903

RESUMO

Moment arms represent a muscle's ability to generate a moment about a joint for a given muscle force. The goal of this study was to develop a method to measure muscle moment arms in vivo over a large range of motion using real-time magnetic resonance (MR) imaging. Rectus femoris muscle-tendon lengths and knee joint angles of healthy subjects (N = 4) were measured during dynamic knee joint flexion and extension in a large-bore magnetic resonance imaging (MRI) scanner. Muscle-tendon moment arms were determined at the knee using the tendon-excursion method by differentiating measured muscle-tendon length with respect to joint angle. Rectus femoris moment arms were averaged across a group of healthy subjects and were found to vary similarly during knee joint flexion (mean: 3.0 (SD 0.5) cm, maximum: 3.5 cm) and extension (mean: 2.8 (SD 0.4) cm, maximum: 3.6 cm). These moment arms compare favorably with previously published dynamic tendon-excursion measurements in cadaveric specimens but were relatively smaller than moment arms from center-of-rotation studies. The method presented here provides a new approach to measure muscle-tendon moment arms in vivo and has the potential to be a powerful resource for characterizing musculoskeletal geometry during dynamic joint motion.


Assuntos
Joelho/fisiologia , Imageamento por Ressonância Magnética , Movimento , Músculo Quadríceps/fisiologia , Adulto , Feminino , Humanos , Amplitude de Movimento Articular , Fatores de Tempo
8.
Med Phys ; 50(10): 6060-6070, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37523236

RESUMO

BACKGROUND: The absence of coronary artery calcium (CAC) measured via CT is associated with very favorable prognosis, and current guidelines recommend low-density lipoprotein cholesterol (LDL-c) lowering therapy for individuals with any CAC. This motivates early detection of small granules of CAC; however, calcium scan sensitivity for detecting very low levels of calcium has not been quantified. PURPOSE: In this work, the size limit of detectability of small calcium hydroxyapatite (CaHA) granules with clinical CAC scanning was assessed using validated simulations. METHODS: CT projections of digital 3D mathematical phantoms containing small CaHA granules were simulated analytically; images were reconstructed using a filter designed to reproduce the point spread function of a specific commercial scanner, and a relationship of HU number versus diameter was derived. These simulation results were validated with experimental measurements of HU versus diameter from phantoms containing small granules of CaHA on a GE Revolution CT scanner in the clinic; ground truth measurements of the CaHA granule diameters were obtained using a Zeiss Xradia 510 Versa high-resolution 3D micro-CT imaging system. Using experimental measurements on the clinical CT scanner, detectability was quantified with a detectability index (d') using a non-prewhitened matched filter. The effect of changes to reconstruction slice thickness and reconstruction kernel on granule detectability was evaluated. RESULTS: Under typical clinical calcium scanning and reconstruction conditions, the minimum detectable diameter of a simulated spherical calcium granule with a clinically relevant CaHA density was 0.76 mm. The minimum detectable volume was 2.4 times smaller on images reconstructed at a slice thickness of 0.625 mm compared to 2.5 mm. The detectability index d' increased by a factor of 1.7 when images were reconstructed with 0.625 mm slices compared to 2.5 mm slices. d' did not change when images were reconstructed with the high-resolution BONE filter compared to the less sharp STANDARD resolution filter on the GE Revolution CT. CONCLUSIONS: We have quantified detectability versus size of small calcium granules at the resolution limit of a widely available clinical CT scanner. Detectability increased significantly with reduced slice thickness and did not change with a sharper reconstruction kernel. The simulation can be used to calculate the trade-off between dose and CAC detectability.

9.
Med Phys ; 49(4): 2309-2323, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35192200

RESUMO

PURPOSE: We demonstrate the viability of a four-dimensional X-ray computed tomography (4DCT) imaging system to accurately and precisely estimate mechanical activation times of left ventricular (LV) wall motion. Accurate and reproducible timing estimates of LV wall motion may be beneficial in the successful planning and management of cardiac resynchronization therapy (CRT). METHODS: We developed an anthropomorphically accurate in silico LV phantom based on human CT images with programmed septal-lateral wall dyssynchrony. Twenty-six temporal phases of the in silico phantom were used to sample the cardiac cycle of 1 s. For each of the 26 phases, 1 cm thick axial slabs emulating axial CT image volumes were extracted, 3D printed, and imaged using a commercially available CT scanner. A continuous dynamic sinogram was synthesized by blending sinograms from these static phases; the synthesized sinogram emulated the sinogram that would be acquired under true continuous phantom motion. Using the synthesized dynamic sinogram, images were reconstructed at 70 ms intervals spanning the full cardiac cycle; these images exhibited expected motion artifact characteristics seen in images reconstructed from real dynamic data. The motion corrupted images were then processed with a novel motion correction algorithm (ResyncCT) to yield motion corrected images. Five pairs of motion uncorrected and motion corrected images were generated, each corresponding to a different starting gantry angle (0 to 180 degrees in 45 degree increments). Two line profiles perpendicular to the endocardial surface were used to sample local myocardial motion trajectories at the septum and the lateral wall. The mechanical activation time of wall motion was defined as the time at which the endocardial boundary crossed a fixed position defined on either of the two line profiles while moving toward the center of the LV during systolic contraction. The mechanical activation times of these myocardial trajectories estimated from the motion uncorrected and the motion corrected images were then compared with those derived from the static images of the 3D printed phantoms (ground truth). The precision of the timing estimates was obtained from the five different starting gantry angle simulations. RESULTS: The range of estimated mechanical activation times observed across all starting gantry angles was significantly larger for the motion uncorrected images than for the motion corrected images (lateral wall: 58 ± 15 ms vs 12 ± 4 ms, p < 0.005; septal wall: 61 ± 13 ms vs 13 ± 9 ms, p < 0.005). CONCLUSIONS: 4DCT images processed with the ResyncCT motion correction algorithm yield estimates of mechanical activation times of LV wall motion with significantly improved accuracy and precision. The promising results reported in this study highlight the potential utility of 4DCT in estimating the timing of mechanical events of interest for CRT guidance.


Assuntos
Tomografia Computadorizada Quadridimensional , Ventrículos do Coração , Artefatos , Tomografia Computadorizada Quadridimensional/métodos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Movimento (Física) , Imagens de Fantasmas
10.
Med Phys ; 49(7): 4404-4418, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35588288

RESUMO

PURPOSE: Standard four-dimensional computed tomography (4DCT) cardiac reconstructions typically include spiraling artifacts that depend not only on the motion of the heart but also on the gantry angle range over which the data was acquired. We seek to reduce these motion artifacts and, thereby, improve the accuracy of left ventricular wall positions in 4DCT image series. METHODS: We use a motion artifact reduction approach (ResyncCT) that is based largely on conjugate pairs of partial angle reconstruction (PAR) images. After identifying the key locations where motion artifacts exist in the uncorrected images, paired subvolumes within the PAR images are analyzed with a modified cross-correlation function in order to estimate 3D velocity and acceleration vectors at these locations. A subsequent motion compensation process (also based on PAR images) includes the creation of a dense motion field, followed by a backproject-and-warp style compensation. The algorithm was tested on a 3D printed phantom, which represents the left ventricle (LV) and on challenging clinical cases corrupted by severe artifacts. RESULTS: The results from our preliminary phantom test as well as from clinical cardiac scans show crisp endocardial edges and resolved double-wall artifacts. When viewed as a temporal series, the corrected images exhibit a much smoother motion of the LV endocardial boundary as compared to the uncorrected images. In addition, quantitative results from our phantom studies show that ResyncCT processing reduces endocardial surface distance errors from 0.9 ± 0.8 to 0.2 ± 0.1 mm. CONCLUSIONS: The ResyncCT algorithm was shown to be effective in reducing motion artifacts and restoring accurate wall positions. Some perspectives on the use of conjugate-PAR images and on techniques for CT motion artifact reduction more generally are also given.


Assuntos
Artefatos , Tomografia Computadorizada Quadridimensional , Algoritmos , Tomografia Computadorizada Quadridimensional/métodos , Ventrículos do Coração/diagnóstico por imagem , Movimento (Física) , Imagens de Fantasmas
11.
Med Phys ; 49(9): 5841-5854, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35751864

RESUMO

BACKGROUND: Estimates of regional left ventricular (LV) strains provide additional information to global function parameters such as ejection fraction (EF) and global longitudinal strain (GLS) and are more sensitive in detecting abnormal regional cardiac function. The accurate and reproducible assessment of regional cardiac function has implications in the management of various cardiac diseases such as heart failure, myocardial ischemia, and dyssynchrony. PURPOSE: To develop a method that yields highly reproducible, high-resolution estimates of regional endocardial strains from 4DCT images. METHODS: A method for estimating regional LV endocardial circumferential ( ε c c ) $( {{\epsilon }_{cc}} )$ and longitudinal ( ε l l ${\epsilon }_{ll}$ ) strains from 4DCT was developed. Point clouds representing the LV endocardial surface were extracted for each time frame of the cardiac cycle from 4DCT images. 3D deformation fields across the cardiac cycle were obtained by registering the end diastolic point cloud to each subsequent point cloud in time across the cardiac cycle using a 3D point-set registration technique. From these deformation fields, ε c c and ε l l ${\epsilon }_{cc}\ {\rm{and\ }}{\epsilon }_{ll}$ were estimated over the entire LV endocardial surface by fitting an affine transformation with maximum likelihood estimation. The 4DCT-derived strains were compared with strains estimated in the same subjects by cardiac magnetic resonance (CMR); twenty-four subjects had CMR scans followed by 4DCT scans acquired within a few hours. Regional LV circumferential and longitudinal strains were estimated from the CMR images using a commercially available feature tracking software (cvi42). Global circumferential strain (GCS) and global longitudinal strain (GLS) were calculated as the mean of the regional strains across the entire LV for both modalities. Pearson correlation coefficients and Bland-Altman analyses were used for comparisons. Intraclass correlation coefficients (ICC) were used to assess the inter- and intraobserver reproducibility of the 4DCT-derived strains. RESULTS: The 4DCT-derived regional strains correlated well with the CMR-derived regional strains ( ε c c ${\epsilon }_{cc}$ : r = 0.76, p < 0.001; ε l l ${\epsilon }_{ll}$ : r = 0.64, p < 0.001). A very strong correlation was found between 4DCT-derived GCS and 4DCT-derived EF (r = -0.96; p < 0.001). The 4DCT-derived strains were also highly reproducible, with very low inter- and intraobserver variability (intraclass correlation coefficients in the range of [0.92, 0.99]). CONCLUSIONS: We have developed a novel method to estimate high-resolution regional LV endocardial circumferential and longitudinal strains from 4DCT images. Except for the definition of the mitral valve and LV outflow tract planes, the method is completely user independent, thus yielding highly reproducible estimates of endocardial strain. The 4DCT-derived strains correlated well with those estimated using a commercial CMR feature tracking software. The promising results reported in this study highlight the potential utility of 4DCT in the precise assessment of regional cardiac function for the management of cardiac disease.


Assuntos
Imagem Cinética por Ressonância Magnética , Função Ventricular Esquerda , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Reprodutibilidade dos Testes
12.
Circ Cardiovasc Imaging ; 15(8): e014165, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35973012

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) is an effective treatment for patients with heart failure; however, 30% of patients do not respond to the treatment. We sought to derive patient-specific left ventricle maps of lead placement scores (LPS) that highlight target pacing lead sites for achieving a higher probability of CRT response. METHODS: Eighty-two subjects recruited for the ImagingCRT trial (Empiric Versus Imaging Guided Left Ventricular Lead Placement in Cardiac Resynchronization Therapy) were retrospectively analyzed. All 82 subjects had 2 contrast-enhanced full cardiac cycle 4-dimensional computed tomography scans: a baseline and a 6-month follow-up scan. CRT response was defined as a reduction in computed tomography-derived end-systolic volume ≥15%. Eight left ventricle features derived from the baseline scans were used to train a support vector machine via a bagging approach. An LPS map over the left ventricle was created for each subject as a linear combination of the support vector machine feature weights and the subject's own feature vector. Performance for distinguishing responders was performed on the original 82 subjects. RESULTS: Fifty-two (63%) subjects were responders. Subjects with an LPS≤Q1 (lower-quartile) had a posttest probability of responding of 14% (3/21), while subjects with an LPS≥ Q3 (upper-quartile) had a posttest probability of responding of 90% (19/21). Subjects with Q1

Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Ensaios Clínicos como Assunto , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Lipopolissacarídeos , Estudos Prospectivos , Estudos Retrospectivos , Tomografia , Resultado do Tratamento , Função Ventricular Esquerda
13.
Magn Reson Med ; 65(1): 51-9, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21053325

RESUMO

Imaging the left ventricular mechanical and hemodynamic response to the stress of exercise may offer early prognosis in select patients with cardiac disease. Here, we demonstrate the feasibility of obtaining simultaneous measurements of longitudinal strain and transvalvular blood velocity during supine bicycle exercise stress in a wide bore magnetic resonance scanner. Combining information from the two datasets, we observe that although the time to peak strain (33.28 ± 1.86 versus 25.7 ± 2.12 as % of R-R interval) and time to peak mitral inflow velocity (44.37 ± 5.21 versus 35.5 ± 4.19 as % of R-R interval) from R-wave of the QRS complex occurred earlier during stress, the time from peak strain to peak mitral inflow velocity was not statistically different (16.5 ± 3.23 versus 13.4 ± 3.06). Further, the percentage of longitudinal relaxation at peak mitral inflow velocity was higher during stress (63.5 ± 7.72 versus 84.32 ± 6.24). These results suggest that although diastole is shortened, early diastolic filling efficiency is augmented during exercise stress in normal volunteers in an effort to maintain stroke volume.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Teste de Esforço/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Esforço Físico/fisiologia , Processamento de Sinais Assistido por Computador , Função Ventricular Esquerda , Algoritmos , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Módulo de Elasticidade/fisiologia , Feminino , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Decúbito Dorsal
14.
JACC Cardiovasc Imaging ; 14(7): 1398-1406, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33454274

RESUMO

OBJECTIVES: The goal of this study was to assess the utility of a genetic risk score (GRS) in targeted coronary artery calcium (CAC) screening among young individuals. BACKGROUND: Early CAC screening and preventive therapy may reduce long-term risk of a coronary heart disease (CHD) event. However, identifying younger individuals at increased risk remains a challenge. GRS for CHD are age independent and can stratify individuals on various risk trajectories. METHODS: Using 142 variants associated with CHD events, we calculated a GRS in 1,927 individuals in the CARDIA (Coronary Artery Risk Development in Young Adults) cohort (aged 32 to 47 years) and 6,600 individuals in the MESA (Multi-Ethnic Study of Atherosclerosis) cohort (aged 44 to 87 years). We assessed GRS utility to predict CAC presence in the CARDIA cohort and stratify individuals of varying risk for CAC presence over the lifetime in both cohorts. RESULTS: The GRS predicted CAC presence in CARDIA males. It was not predictive in CARDIA females, which had a CAC prevalence of 6.4%. In combined analysis of the CARDIA and MESA cohorts, the GRS was predictive of CAC in both males and females and was used to derive an equation for the age at which CAC probability crossed a predetermined threshold. When assessed in combination with traditional risk factors, the GRS further stratified individuals. For individuals with an equal number of traditional risk factors, probability of CAC reached 25% approximately 10 years earlier for those in the highest GRS quintile compared to the lowest. CONCLUSIONS: The GRS may be used to target high-risk younger individuals for early CAC screening.


Assuntos
Cálcio , Vasos Coronários , Vasos Coronários/diagnóstico por imagem , Testes Genéticos , Humanos , Valor Preditivo dos Testes
15.
Funct Imaging Model Heart ; 12738: 242-252, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35287285

RESUMO

Quantification of regional cardiac function is a central goal of cardiology. Multiple methods, such as Coherent Point Drift (CPD) and Simultaneous Subdivision Surface Registration (SiSSR), have been used to register meshes to the endocardial surface. However, these methods do not distinguish between cardiac chambers during registration, and consequently the mesh may "slip" across the interface between two structures during contraction, resulting in inaccurate regional functional measurements. Here, we present Multilabel-SiSSR (M-SiSSR), a novel method for registering a "labeled" cardiac mesh (with each triangle assigned to a cardiac structure). We compare our results to the original, label-agnostic version of SiSSR and find both a visual and quantitative improvement in tracking of the mitral valve plane.

16.
Ann Biomed Eng ; 49(1): 233-250, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32458222

RESUMO

Atrial anisotropy affects electrical propagation patterns, anchor locations of atrial reentrant drivers, and atrial mechanics. However, patient-specific atrial fibre fields and anisotropy measurements are not currently available, and consequently assigning fibre fields to atrial models is challenging. We aimed to construct an atrial fibre atlas from a high-resolution DTMRI dataset that optimally reproduces electrophysiology simulation predictions corresponding to patient-specific fibre fields, and to develop a methodology for automatically assigning fibres to patient-specific anatomies. We extended an atrial coordinate system to map the pulmonary veins, vena cava and appendages to standardised positions in the coordinate system corresponding to the average location across the anatomies. We then expressed each fibre field in this atrial coordinate system and calculated an average fibre field. To assess the effects of fibre field on patient-specific modelling predictions, we calculated paced activation time maps and electrical driver locations during AF. In total, 756 activation time maps were calculated (7 anatomies with 9 fibre maps and 2 pacing locations, for the endocardial, epicardial and bilayer surface models of the LA and RA). Patient-specific fibre fields had a relatively small effect on average paced activation maps (range of mean local activation time difference for LA fields: 2.67-3.60 ms, and for RA fields: 2.29-3.44 ms), but had a larger effect on maximum LAT differences (range for LA 12.7-16.6%; range for RA 11.9-15.0%). A total of 126 phase singularity density maps were calculated (7 anatomies with 9 fibre maps for the LA and RA bilayer models). The fibre field corresponding to anatomy 1 had the highest median PS density map correlation coefficient for LA bilayer simulations (0.44 compared to the other correlations, ranging from 0.14 to 0.39), while the average fibre field had the highest correlation for the RA bilayer simulations (0.61 compared to the other correlations, ranging from 0.37 to 0.56). For sinus rhythm simulations, average activation time is robust to fibre field direction; however, maximum differences can still be significant. Patient specific fibres are more important for arrhythmia simulations, particularly in the left atrium. We propose using the fibre field corresponding to DTMRI dataset 1 for LA simulations, and the average fibre field for RA simulations as these optimally predicted arrhythmia properties.


Assuntos
Atlas como Assunto , Função Atrial , Átrios do Coração/anatomia & histologia , Modelagem Computacional Específica para o Paciente , Anisotropia , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/fisiopatologia , Imagem de Difusão por Ressonância Magnética , Átrios do Coração/diagnóstico por imagem , Humanos
17.
Struct Heart ; 5(4): 410-419, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34541443

RESUMO

BACKGROUND: Regional left ventricular (LV) mechanics in mitral regurgitation (MR) patients, and local changes in function after transcatheter mitral valve implantation (TMVI) have yet to be evaluated. Herein, we introduce a method for creating high resolution maps of endocardial function from 4DCT images, leading to detailed characterization of changes in local LV function. These changes are particularly interesting when evaluating the effect of the Tendyne™ TMVI device in the region of the epicardial pad. METHODS: Regional endocardial shortening from CT (RSCT) was evaluated in Tendyne (Abbott Medical) TMVI patients with 4DCT exams pre- and post-implantation. Regional function was evaluated in 90 LV segments (5 longitudinal × 18 circumferential). LV volumes and ejection fraction (EF) were also computed. A reproducibility study was performed in a subset of patients to determine the precision of RSCT measurements in this population. RESULTS: Baseline and local changes in RSCT post TMVI were highly variable and extremely spatially heterogeneous. Both inter- and intra-observer variability were low and demonstrated the high precision of RSCT for evaluating regional LV function. CONCLUSION: RSCT is a reproducible metric which can be evaluated in patients with highly abnormal regional LV function and geometry. After TMVI, significant spatially heterogeneous changes in RSCT were observed in all subjects; therefore, it is unlikely that the functional state of TMVI patients can be fully described by changes in LV volume or EF. Measurement of RSCT provides precise characterization of the spatially heterogeneous effects of MR and TMVI on LV function and remodeling.

18.
Magn Reson Med ; 64(6): 1814-20, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20878764

RESUMO

This work improves the performance of interactive real-time imaging with balanced steady-state free precession. The method employs hardware-optimized gradient pulses, together with a novel phase-encoding strategy that simplifies the design and implementation of the optimized gradient waveforms. In particular, the waveforms for intermediate phase-encode steps are obtained by simple linear combination, rather than separate optimized waveform calculations. Gradient waveforms are redesigned in real time as the scan plane is manipulated, and the resulting sequence operates at the specified limits of the MRI gradient subsystem for each new scan-plane orientation. The implementation provides 14-25% improvement in the sequence pulse repetition time over the vendor-supplied interactive real-time imaging sequence for similar scan parameters on our MRI scanner.


Assuntos
Coração , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Modelos Teóricos
19.
Magn Reson Med ; 63(4): 1070-9, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20373408

RESUMO

The accurate visualization of interventional devices is crucial for the safety and effectiveness of MRI-guided interventional procedures. In this paper, we introduce an improvement to the visualization of active devices. The key component is a fast, robust method ("CurveFind") that reconstructs the three-dimensional trajectory of the device from projection images in a fraction of a second. CurveFind is an iterative prediction-correction algorithm that acts on a product of orthogonal projection images. By varying step size and search direction, it is robust to signal inhomogeneities. At the touch of a key, the imaged slice is repositioned to contain the relevant section of the device ("SnapTo"), the curve of the device is plotted in a three-dimensional display, and the point on a target slice, which the device will intersect, is displayed. These features have been incorporated into a real-time MRI system. Experiments in vitro and in vivo (in a pig) have produced successful results using a variety of single- and multichannel devices designed to produce both spatially continuous and discrete signals. CurveFind is typically able to reconstruct the device curve, with an average error of approximately 2 mm, even in the case of complex geometries.


Assuntos
Algoritmos , Aumento da Imagem/instrumentação , Imagem por Ressonância Magnética Intervencionista/instrumentação , Animais , Biópsia por Agulha/instrumentação , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Imagens de Fantasmas , Suínos , Doenças Vasculares/cirurgia
20.
Med Image Anal ; 65: 101748, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32711368

RESUMO

The location of the mitral and aortic valves in dynamic cardiac imaging is useful for extracting functional derived parameters such as ejection fraction, valve excursions, and global longitudinal strain, and when performing anatomical structures tracking using slice following or valve intervention's planning. Completely automatic segmentation methods are still challenging tasks because of their fast movements and the different positions that prevent good visibility of the leaflets along the full cardiac cycle. In this article, we propose a processing pipeline to track the displacement of the aortic and mitral valve annuli from high-resolution cardiac four-dimensional computed tomographic angiography (4D-CTA). The proposed method is based on the dynamic separation of left ventricle, left atrium and aorta using statistical shape modeling and an energy minimization algorithm based on graph-cuts and has been evaluated on a set of 15 electrocardiography-gated 4D-CTAs. We report a mean agreement distance between manual annotations and our proposed method of 2.52±1.06 mm for the mitral annulus and 2.00±0.69 mm for the aortic valve annulus based on valve locations detected from manual anatomical landmarks. In addition, we show the effect of detecting the valvular planes on derived functional parameters (ejection fraction, global longitudinal strain, and excursions of the mitral and aortic valves).


Assuntos
Valva Aórtica , Valva Mitral , Angiografia , Aorta , Valva Aórtica/diagnóstico por imagem , Humanos , Valva Mitral/diagnóstico por imagem , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA