Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Vasc Interv Radiol ; 34(5): 896-901, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36626978

RESUMO

PURPOSE: To compare the performance of a prototype high-flow catheter connector, the Lamprey Lock, with that of a conventional Luer connector. MATERIALS AND METHODS: The Lamprey Lock was created to eliminate the choke point resulting from Luer connections by achieving a cross-sectional area approximately 2.5 times larger than that achieved by a conventional Luer connector. A Lamprey Lock 3-way connector was also created by expanding the inner channels of a traditional Luer 3-way connector and exchanging the male Luer connection with a Lamprey Lock connection. These were tested against unaltered Luer and Luer 3-way connectors to compare flow rates using in vitro models of serous and purulent fluid. Each experimental condition was repeated 5 times. RESULTS: In the serous model, the mean drainage rate was 4.4 mL/s (95% CI, 4.3-4.6) and 3.3 mL/s (95% CI, 3.3-3.5) for the Lamprey Lock and Luer connector, respectively (P < .001). The mean drainage rate was 4.2 mL/s (95% CI, 3.9-4.5) and 2.7 mL/s (95% CI, 2.5-2.8) for the Lamprey Lock 3-way and Luer 3-way connector, respectively (P < .001). In the purulent model, the mean drainage rate was 1.4 mL/min (95% CI, 1.3-1.6) and 0.75 mL/min (95% CI, 0.68-0.82) for the Lamprey Lock and Luer connector, respectively (P < .001). The mean drainage rate was 1.5 mL/min (95% CI, 1.3-1.7) and 0.74 mL/min (95% CI, 0.70-0.78) for the Lamprey Lock 3-way and Luer 3-way connector, respectively (P < .001). CONCLUSIONS: The proposed high-flow catheter connector, the Lamprey Lock, demonstrated higher flow rates than those demonstrated by a conventional Luer connector in vitro.


Assuntos
Catéteres , Humanos , Masculino , Desenho de Equipamento
2.
Eur Radiol ; 32(9): 6327-6335, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35389047

RESUMO

OBJECTIVES: To investigate the usefulness of minimal ablative margin (MAM) control by intra-procedural contrast-enhanced CT (CECT) in microwave ablation (MWA) of liver tumors. METHODS: A total of 334 consecutive liver tumors (240 hepatocellular carcinomas [HCCs] and 94 colorectal liver metastases [CRLMs]) in 172 patients treated with percutaneous MWA were retrospectively included. MAM of each tumor was assessed after expected ablation completion using intra-procedural CECT, allowing within-session additional ablation to any potentially insufficient margin. On immediate post-MWA MRI, complete ablation coverage of tumor and final MAM status were determined. The cumulative local tumor progression (LTP) rate was estimated by using the Kaplan-Meier method. To identify predictors of LTP, Cox regression analysis with a shared frailty model was performed. RESULTS: Intra-procedural CECT findings prompted additional ablation in 18.9% (63/334) of tumors. Final complete ablation coverage of tumor and sufficient MAM were determined by MRI to be achieved in 99.4% (332/334) and 77.5% (259/334), and their estimated 6-month, 1-year, and 2-year LTP rates were 3.2%, 7.5%, and 12.9%; and 1.0%, 2.1%, and 6.9%, respectively. Insufficient MAM on post-MWA MRI, perivascular tumor location, and tumor size (cm) were independent risk factors for LTP (hazard ratio = 14.4, 6.0, and 1.1, p < 0.001, p = 0.003, and p = 0.011, respectively), while subcapsular location and histology (HCC vs CRLM) were not. CONCLUSIONS: In MWA of liver tumors, intra-procedural CECT monitoring of minimal ablative margin facilitates identification of potentially suboptimal margins and guides immediate additional intra-session ablation to maximize rates of margin-sufficient ablations, the latter being a highly predictive marker for excellent long-term local tumor control. KEY POINTS: • In MWA of liver tumors, intra-procedural CECT can identify potentially suboptimal minimal ablative margin, leading to immediate additional ablation in a single treatment session. • Achieving a finally sufficient ablative margin through the MWA with intra-procedural CECT monitoring of minimal ablative margin results in excellent local tumor control.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/cirurgia , Ablação por Cateter/métodos , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Margens de Excisão , Micro-Ondas/uso terapêutico , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
3.
Haematologica ; 106(8): 2161-2169, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32675221

RESUMO

Hereditary hemorrhagic telangiectasia (HHT, Osler-Weber-Rendu disease) is a rare multisystem vascular disorder causing chronic gastrointestinal bleeding, epistaxis, and severe anemia. Bevacizumab, an anti-vascular endothelial growth factor antibody, may be effective to treat bleeding in HHT. This international, multicenter, retrospective study evaluated the use of systemic bevacizumab to treat HHT-associated bleeding and anemia at 12 HHT treatment centers. Hemoglobin, epistaxis severity score, red cell units transfused, and intravenous iron infusions before and after treatment were evaluated using paired means testing and mixed-effects linear models. 238 HHT patients received bevacizumab for a median of 12 (range, 1-96) months. Compared with pretreatment, bevacizumab increased mean hemoglobin by 3.2 g/dL (95% CI, 2.9-3.5 g/dL) [mean hemoglobin 8.6 (8.5, 8.8) g/dL versus 11.8 (11.5, 12.1) g/dL, p<0.0001)] and decreased the epistaxis severity score (ESS) by 3.4 (3.2-3.7) points [mean ESS 6.8 (6.6-7.1) versus 3.4 (3.2-3.7), P<0.0001] during the first year of treatment. Compared with 6 months pretreatment, RBC units transfused decreased by 82% [median of 6.0 (IQR 0.0-13.0) units versus 0 (IQR, 0.0-1.0) units, P<0.0001] and iron infusions decreased by 70% [median of 6.0 (1.0-18.0) infusions versus 1.0 (0.0-4.0) infusions, P<0.0001] during the first 6 months of bevacizumab treatment. Outcomes were similar regardless of underlying pathogenic mutation. Following initial induction infusions, continuous/scheduled bevacizumab maintenance achieved higher hemoglobin and lower ESS than intermittent/as needed maintenance but with more drug exposure. Bevacizumab was well tolerated: hypertension, fatigue, and proteinuria were the most common adverse events. Venous thromboembolism occurred in 2% of patients. In conclusion, systemic bevacizumab was safe and effective to manage chronic bleeding and anemia in HHT.


Assuntos
Telangiectasia Hemorrágica Hereditária , Administração Intravenosa , Bevacizumab/uso terapêutico , Hemorragia/tratamento farmacológico , Humanos , Estudos Retrospectivos , Telangiectasia Hemorrágica Hereditária/complicações , Telangiectasia Hemorrágica Hereditária/tratamento farmacológico
4.
J Vasc Interv Radiol ; 32(6): 882-889, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33689833

RESUMO

PURPOSE: To compare the performance of a dual-lumen flushable drainage catheter to a conventional catheter for complex fluid collection drainage. METHODS: Two prototype catheters (20- and 28-F) were created by incorporating a customized infusion lumen within the wall of a large-bore conventional drainage catheter, which facilitated simultaneous irrigation of the drainage lumen and the targeted collection via inward- and outward-facing infusion side holes. These were tested against unaltered 20- and 28-F conventional catheters to determine if the injection of a dedicated flush lumen improved rapidity and completeness of gravity drainage. In vitro models were created to simulate serous fluid, purulent/exudative fluid, particulate debris, and acute hematoma. RESULTS: In the purulent model, mean drainage rate was 19.9 ± 8.0 and 9.5±1.4 mL/min for the 20-F prototype and control (P < .001) and 63.9 ± 4.3 and 35.4 ± 3.4 mL/min for the 28-F prototype and control (P = .006), respectively, with complete drainage achieved in all trials. In the particulate model, mean drainage rate was 24.5 ± 9.7 and 12.0 ± 12.5 mL/min for the 28-F prototype and control (P = .003), respectively, with 69.0% versus 41.1% total drainage achieved over 24 minutes (P = .029). In the hematoma model, mean drainage rate was 22.7 ± 4.6 and 4.8 ± 4.3 mL/min for the 28-F prototype and control (P = .022), respectively, with 80.3% versus 20.1% drainage achieved over 15 minutes (P = .003). Particulate and hematoma 20-F prototypes and conventional trials failed due to immediate occlusion. CONCLUSIONS: The proposed dual-lumen drainage catheter with irrigation of a dedicated flush lumen improved evacuation of complex fluid collections in vitro.


Assuntos
Cateterismo/instrumentação , Catéteres , Drenagem/instrumentação , Irrigação Terapêutica/instrumentação , Desenho de Equipamento , Teste de Materiais , Fatores de Tempo
5.
J Vasc Interv Radiol ; 32(7): 993-1001, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33722495

RESUMO

PURPOSE: To compare coil embolotherapy outcomes of feeding-artery-only versus nidus-plus-feeding-artery technique for treating pulmonary arteriovenous malformations (PAVMs). MATERIALS AND METHODS: A total of 219 treatment-naïve PAVMs embolized in 90 patients at a single center from 2008 to 2018 met inclusion criteria for retrospective evaluation. Of the patients, 87% had a diagnosis of hereditary hemorrhagic telangiectasia (HHT). Feeding artery (FA) diameters ≥2 mm were treated. Coil embolization techniques were classified on the basis of embolic deployment zone: (i) distal feeding artery (DFA) technique (coil-to-nidus distance ≤ 1 cm) or (ii) nidus plus feeding artery (NiFA) technique. Successful embolization predictors were assessed using a multivariate linear regression model with input from patient- and PAVM-specific variables. RESULTS: Treatment success was achieved in 192 of 219 PAVMs (87.7%) over a mean follow-up period of 19 months. Statistically significant predictors of success in the linear regression model included simple angioarchitecture, NiFA embolization technique, and shorter follow-up duration. Stratified by technique, success rates were 99 of 105 (94.3%) and 93 of 114 (81.6%) PAVMs for NiFA and DFA, respectively (P = .007). On average, NiFA-embolized PAVMs had a larger FA diameter (3.6 mm vs 2.7 mm, P < .001) and comprised more complex PAVMs (48% vs 22%, P < .001) than DFA. Treatment success was not significantly associated with sac size or FA diameter. CONCLUSIONS: Coil embolization of both the nidus and FA was associated with a higher persistent occlusion rate than FA embolization alone.


Assuntos
Malformações Arteriovenosas , Embolização Terapêutica , Veias Pulmonares , Telangiectasia Hemorrágica Hereditária , Malformações Arteriovenosas/diagnóstico por imagem , Malformações Arteriovenosas/terapia , Embolização Terapêutica/efeitos adversos , Humanos , Artéria Pulmonar/diagnóstico por imagem , Veias Pulmonares/diagnóstico por imagem , Estudos Retrospectivos , Resultado do Tratamento
6.
J Vasc Interv Radiol ; 31(10): 1691-1696.e1, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32178944

RESUMO

PURPOSE: To characterize the effect of hepatic vessel flow using 4-dimensional (4D) flow magnetic resonance (MR) imaging and correlate their effect on microwave ablation volumes in an in vivo non-cirrhotic porcine liver model. MATERIALS AND METHODS: Microwave ablation antennas were placed under ultrasound guidance in each liver lobe of swine (n = 3 in each animal) for a total of 9 ablations. Pre- and post-ablation 4D flow MR imaging was acquired to quantify flow changes in the hepatic vasculature. Flow measurements, along with encompassed vessel size and vessel-antenna spacing, were then correlated with final ablation volume from segmented MR images. RESULTS: The linear regression model demonstrated that the preablation measurement of encompassed hepatic vein size (ß = -0.80 ± 0.25, 95% confidence interval [CI] -1.15 to -0.22; P = .02) was significantly correlated to final ablation zone volume. The addition of hepatic vein flow rate found via 4D flow MRI (ß = -0.83 ± 0.65, 95% CI -2.50 to 0.84; P = .26), and distance from antenna to hepatic vein (ß = 0.26 ± 0.26, 95% CI -0.40 to 0.92; P = .36) improved the model accuracy but not significantly so (multivariate adjusted R2 = 0.70 vs univariate (vessel size) adjusted R2 = 0.63, P = .24). CONCLUSIONS: Hepatic vein size in an encompassed ablation zone was found to be significantly correlated with final ablation zone volume. Although the univariate 4D flow MR imaging-acquired measurements alone were not found to be statistically significant, its addition to hepatic vein size improved the accuracy of the ablation volume regression model. Pre-ablation 4D flow MR imaging of the liver may assist in prospectively optimizing thermal ablation treatment.


Assuntos
Técnicas de Ablação , Veias Hepáticas/diagnóstico por imagem , Circulação Hepática , Fígado/irrigação sanguínea , Fígado/cirurgia , Imagem Cinética por Ressonância Magnética , Micro-Ondas , Imagem de Perfusão/métodos , Animais , Velocidade do Fluxo Sanguíneo , Estudos de Viabilidade , Veias Hepáticas/fisiopatologia , Modelos Animais , Valor Preditivo dos Testes , Sus scrofa
7.
Angiogenesis ; 22(1): 145-155, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30191360

RESUMO

Pazopanib (Votrient) is an orally administered tyrosine kinase inhibitor that blocks VEGF receptors potentially serving as anti-angiogenic treatment for hereditary hemorrhagic telangiectasia (HHT). We report a prospective, multi-center, open-label, dose-escalating study [50 mg, 100 mg, 200 mg, and 400 mg], designed as a proof-of-concept study to demonstrate efficacy of pazopanib on HHT-related bleeding, and to measure safety. Patients, recruited at 5 HHT Centers, required ≥ 2 Curacao criteria AND [anemia OR severe epistaxis with iron deficiency]. Co-primary outcomes, hemoglobin (Hgb) and epistaxis severity, were measured during and after treatment, and compared to baseline. Safety monitoring occurred every 1.5 weeks. Seven patients were treated with 50 mg pazopanib daily. Six/seven showed at least 50% decrease in epistaxis duration relative to baseline at some point during study; 3 showed at least 50% decrease in duration during Weeks 11 and 12. Six patients showed a decrease in ESS of > 0.71 (MID) relative to baseline at some point during study; 3/6 showed a sustained improvement. Four patients showed > 2 gm improvement in Hgb relative to baseline at one or more points during study. Health-related QOL scores improved on all SF-36 domains at Week 6 and/or Week 12, except general health (unchanged). There were 19 adverse events (AE) including one severe AE (elevated LFTs, withdrawn from dosing at 43 days); with no serious AE. In conclusion, we observed an improvement in Hgb and/or epistaxis in all treated patients. This occurred at a dose much lower than typically used for oncologic indications, with no serious AE. Further studies of pazopanib efficacy are warranted.


Assuntos
Hemorragia , Pirimidinas , Sulfonamidas , Telangiectasia Hemorrágica Hereditária , Adulto , Feminino , Hemorragia/sangue , Hemorragia/tratamento farmacológico , Humanos , Indazóis , Masculino , Pessoa de Meia-Idade , Pirimidinas/administração & dosagem , Pirimidinas/farmacocinética , Sulfonamidas/administração & dosagem , Sulfonamidas/farmacocinética , Telangiectasia Hemorrágica Hereditária/sangue , Telangiectasia Hemorrágica Hereditária/tratamento farmacológico
8.
Eur Radiol ; 29(1): 68-74, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29926207

RESUMO

OBJECTIVES: The purpose of this study was to describe a single institution's experience with transradial access (TRA) for angiographic interventions, and to compare technical success, complication rate and radiation dose of procedures performed with TRA to those performed with transfemoral access (TFA). METHODS: A retrospective cohort study of patients undergoing peripheral interventions via TRA or TFA from 2015 to 2017 was performed. The cohort comprised 33 patients undergoing 44 procedures via TRA and 37 patients undergoing 44 procedures via TFA. Outcome measures were technical success, access-related complications, fluoroscopy time and radiation exposure. Differences at p < 0.05 were considered to be statistically significant. RESULTS: Baseline characteristics were similar between patients who had procedures via TRA versus those who had procedures via TFA, including age, sex and body mass index. Technical success was achieved in 41/44 (93.2%) of procedures performed via TRA, compared to 44/44 (100%) of procedures performed via TFA (p = 0.241). There were three access-related complications (6.8%) when TRA was performed, compared to none when TFA was performed (p = 0.241). Fluoroscopy time was longer in procedures performed with TRA compared to those performed with TFA (27.3 vs 20.4, p = 0.033). Dose area product (DAP) did not differ with access site choice (p = 0.186). CONCLUSIONS: TRA is a safe and feasible alternative to TFA for a range of peripheral interventions. However, TRA must be performed with prudence as it is not without complications and is technically challenging, leading to longer fluoroscopy time. KEY POINTS: • Transradial access (TRA) is feasible in a variety of peripheral interventions, achieving success in 93.2% of cases. • Access-related complications are comparable between transfemoral access (TFA) and TRA (p = 0.241), but prudence must be taken during TRA as it could be technically challenging. • Procedures performed with TRA tend to have longer fluoroscopy time compared to those performed with TFA (p = 0.033), but the DAPs are comparable (p = 0.186).


Assuntos
Angiografia/métodos , Cateterismo Periférico/métodos , Exposição à Radiação/efeitos adversos , Angiografia/efeitos adversos , Estudos de Viabilidade , Feminino , Artéria Femoral , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Radial , Estudos Retrospectivos , Resultado do Tratamento
9.
J Vasc Interv Radiol ; 30(11): 1820-1823, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31587945

RESUMO

Eight patients with giant prostatic enlargement > 200 mL and lower urinary tract symptoms who underwent bilateral prostatic artery embolization (PAE) were reviewed. Mean prostate volume decreased from 318.2 mL to 212.2 mL (P < .01). At 5-month mean follow-up, International Prostate Symptom Score decreased by 16.7 points (P < .05), and urinary quality of life improved by 3.0 points (P < .01). Three of 4 catheter-dependent patients no longer needed catheterization after the procedure. No major complications were encountered. Preliminary results suggest PAE is safe and effective in patients with giant prostatic enlargement > 200 mL.


Assuntos
Embolização Terapêutica , Sintomas do Trato Urinário Inferior , Hiperplasia Prostática , Artérias , Humanos , Masculino , Qualidade de Vida , Resultado do Tratamento
11.
Am J Gastroenterol ; 113(8): 1187-1196, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29899437

RESUMO

BACKGROUND: Overt hepatic encephalopathy (OHE) is a serious complication of liver dysfunction, which is associated with severe morbidity/mortality and healthcare resource utilization. OHE can be medically refractory due to spontaneous portosystemic shunts (SPSSs) and therefore a new treatment option for these SPSSs is critical. METHODS: This is a retrospective study of 43 patients with medically refractory OHE, who underwent CARTO (Coil-Assisted Retrograde Transvenous Obliteration) procedures between June 2012 and October 2016. The patient demographic characteristics, technical and clinical outcomes with an emphasis on HE improvement, and complications are reviewed and analyzed. RESULTS: The overall clinical success rate was 91% with a significant HE improvement. Eighty-one percent of patients had clinically significant improvement from OHE and 67% of patients had complete resolution of their HE symptoms during our follow-up period of 893 ± 585 days (range 36-1881 days, median 755.0 days). The median WH score improved from 3 (range 2-4) pre-CARTO to 1 (range 0-4) post-CARTO (p < 0.001). The median ammonia level significantly decreased from 134.5 pre-CARTO to 70.0 post-CARTO (p < 0.001) in 3 days. The overall mean survival was 1465.5 days (95% CI of 1243.0 and 1688.0 days). Only three patients had recurrent HE symptoms. There were 39.6% minor complication rate including new or worsened ascites and esophageal varices, and only 2.3% major complication rate requiring additional treatment (one patient with bleeding esophageal varices requiring treatment). No procedure-related death is noted. CONCLUSIONS: CARTO appears to be a safe and effective treatment option for refractory overt hepatic encephalopathy (OHE) due to spontaneous portosystemic shunts. CARTO could be an excellent addition to currently available treatment options for these patients.


Assuntos
Embolização Terapêutica , Encefalopatia Hepática/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Ascite , California , Varizes Esofágicas e Gástricas , Feminino , Encefalopatia Hepática/diagnóstico por imagem , Encefalopatia Hepática/mortalidade , Humanos , Masculino , Prontuários Médicos , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias , Estudos Retrospectivos , Análise de Sobrevida , Tomografia Computadorizada por Raios X
13.
Can Assoc Radiol J ; 68(1): 84-89, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27887933

RESUMO

Prostate artery embolization has garnered much attention as a promising treatment for lower urinary tract symptoms secondary to benign prostatic hyperplasia. We aim to provide an up-to-date review of this minimally invasive technique, including discussion of potential benefits and technical challenges. Current evidence suggests it is a safe and effective option for patients with medication-refractory urinary obstructive symptoms who are poor surgical candidates or refuse surgical therapy. Larger, randomized studies with long-term follow-up data are needed for this technique to be formally established in the treatment paradigm for benign prostatic hyperplasia.


Assuntos
Embolização Terapêutica/métodos , Hiperplasia Prostática/terapia , Humanos , Masculino , Próstata/patologia , Hiperplasia Prostática/patologia , Resultado do Tratamento
15.
J Vasc Interv Radiol ; 27(5): 623-30, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27013403

RESUMO

PURPOSE: To evaluate preliminary outcomes after microwave ablation (MWA) of hepatocellular carcinoma (HCC) up to 5 cm and to determine the influence of tumor size. MATERIALS AND METHODS: Electronic records were searched for HCC and MWA. Between January 2011 and September 2014, 173 HCCs up to 5 cm were treated by MWA in 129 consecutive patients (89 men, 40 women; mean age, 66.9 y ± 9.5). Tumor characteristics related to local tumor progression and primary and secondary treatment efficacy were evaluated by univariate analysis. Outcomes were compared between tumors ≤ 3 cm and tumors > 3 cm. RESULTS: Technical success, primary efficacy, and secondary efficacy were 96.5%, 99.4%, and 94.2% at a mean follow-up period of 11.8 months ± 9.8 (range, 0.8-40.6 mo). Analysis of tumor characteristics showed no significant risk factor for local tumor progression, including subcapsular location (P = .176), tumor size (P = .402), and perivascular tumor location (P = .323). The 1-year and 2-year secondary or overall treatment efficacy rates for tumors measuring ≤ 3 cm were 91.2% and 82.1% and for tumors 3.1-5 cm were 92.3% and 83.9% (P = .773). The number of sessions to achieve secondary efficacy was higher in the larger tumor group (1.13 vs 1.06, P = .005). There were three major complications in 134 procedures (2.2%). CONCLUSIONS: With use of current-generation MWA devices, percutaneous ablation of HCCs up to 5 cm can be achieved with high efficacy.


Assuntos
Técnicas de Ablação/métodos , Carcinoma Hepatocelular/cirurgia , Neoplasias Hepáticas/cirurgia , Micro-Ondas/uso terapêutico , Carga Tumoral , Técnicas de Ablação/efeitos adversos , Técnicas de Ablação/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Registros Eletrônicos de Saúde , Desenho de Equipamento , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Masculino , Micro-Ondas/efeitos adversos , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
16.
J Vasc Interv Radiol ; 27(12): 1779-1785, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27670943

RESUMO

PURPOSE: To assess adoption and survey-based satisfaction rates following deployment of standardized interventional radiology (IR) procedure reports across multiple institutions. MATERIALS AND METHODS: Standardized reporting templates for 5 common interventional procedures (central venous access, inferior vena cava [IVC] filter insertion, IVC filter removal, uterine artery embolization, and vertebral augmentation) were distributed to 20 IR practices in a prospective quality-improvement study. Participating sites edited the reports according to institutional preferences and deployed them for a 1-year pilot study concluding in July 2015. Study compliance was measured by sampling 20 reports of each procedure type at each institution, and surveys of interventionalists and referring physicians were performed. Modifications to the standardized reporting templates at each site were analyzed. RESULTS: Ten institutions deployed the standardized reports, with 8 achieving deployment of 3-12 months. The mean report usage rate was 57%. Each site modified the original reports, with 26% mean reduction in length, 18% mean reduction in wordiness, and 60% mean reduction in the number of forced fill-in fields requiring user input. Linear-regression analysis revealed that reduced number of forced fill-in fields correlated significantly with increased usage rate (R2 = 0.444; P = .05). Surveys revealed high satisfaction rates among referring physicians but lower satisfaction rates among interventional radiologists. CONCLUSIONS: Standardized report adoption rates increased when reports were simplified by reducing the number of forced fill-in fields. Referring physicians preferred the standardized reports, whereas interventional radiologists preferred standard narrative reports.


Assuntos
Documentação/normas , Controle de Formulários e Registros/normas , Prontuários Médicos/normas , Padrões de Prática Médica/normas , Radiografia Intervencionista/normas , Cateterismo Venoso Central/normas , Remoção de Dispositivo/normas , Documentação/métodos , Feminino , Fidelidade a Diretrizes/normas , Pesquisas sobre Atenção à Saúde , Humanos , Masculino , Projetos Piloto , Guias de Prática Clínica como Assunto/normas , Estudos Prospectivos , Implantação de Prótese/instrumentação , Implantação de Prótese/normas , Melhoria de Qualidade/normas , Indicadores de Qualidade em Assistência à Saúde/normas , Radiografia Intervencionista/métodos , Estados Unidos , Embolização da Artéria Uterina/normas , Filtros de Veia Cava , Vertebroplastia/normas
17.
Dig Dis Sci ; 61(10): 2838-2846, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27349987

RESUMO

BACKGROUND: Despite widespread use of transjugular intrahepatic portosystemic shunt (TIPS) for treatment of portal hypertension, a paucity of nationwide data exists on predictors of the economic impact related to TIPS. AIMS: Using the National Inpatient Sample (NIS) database from 2001 to 2012, we aimed to evaluate factors contributing to hospital cost of patients admitted to US hospitals for TIPS. METHODS: Using the NIS, we identified a discharge-weighted national estimate of 61,004 TIPS procedures from 2001 to 2012. Through independent sample analysis, we determined profile factors related to increases in hospital costs. RESULTS: Of all TIPS cases, the mean charge adjusted for inflation to the year 2012 is $125,044 ± $160,115. The mean hospital cost adjusted for inflation is $44,901 ± $54,565. Comparing pre- and post-2005, mean charges and cost have increased considerably ($98,154 vs. $142,652, p < 0.001 and $41,656 vs. $46,453, p < 0.001, respectively). Patients transferred from a different hospital, weekend admissions, Asian/Pacific Islander patients, and hospitals in the Northeastern and Western region had higher cost. Number of diagnoses and number of procedures show positive correlations with hospital cost, with number of procedures exhibiting stronger relationships (Pearson 0.613). Comorbidity measures with highest increases in cost were pulmonary circulation disorders ($32,157 increase, p < 0.001). CONCLUSION: The cost of the TIPS procedure is gradually rising for hospitals. Alongside recent healthcare reform through the Affordable Care Act, measures to reduce the economic burden of TIPS are of increasing importance. Data from this study are intended to aid physicians and hospitals in identifying improvements that could reduce hospital costs.


Assuntos
Custos Hospitalares , Hospitalização/economia , Hipertensão Portal/cirurgia , Derivação Portossistêmica Transjugular Intra-Hepática/economia , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Povo Asiático/estatística & dados numéricos , Criança , Pré-Escolar , Comorbidade , Custos e Análise de Custo , Bases de Dados Factuais , Emergências , Etnicidade/estatística & dados numéricos , Feminino , Hospitais de Ensino/estatística & dados numéricos , Humanos , Hipertensão Portal/economia , Lactente , Recém-Nascido , Pneumopatias/epidemiologia , Masculino , Pessoa de Meia-Idade , Havaiano Nativo ou Outro Ilhéu do Pacífico/estatística & dados numéricos , New England/epidemiologia , Estados do Pacífico/epidemiologia , Transferência de Pacientes/estatística & dados numéricos , Circulação Pulmonar , Fatores Sexuais , Estados Unidos/epidemiologia , População Branca/estatística & dados numéricos , Adulto Jovem
18.
JAMA ; 316(9): 943-51, 2016 09 06.
Artigo em Inglês | MEDLINE | ID: mdl-27599329

RESUMO

IMPORTANCE: Epistaxis is a major factor negatively affecting quality of life in patients with hereditary hemorrhagic telangiectasia (HHT; also known as Osler-Weber-Rendu disease). Optimal treatment for HHT-related epistaxis is uncertain. OBJECTIVE: To determine whether topical therapy with any of 3 drugs with differing mechanisms of action is effective in reducing HHT-related epistaxis. DESIGN, SETTING, AND PARTICIPANTS: The North American Study of Epistaxis in HHT was a double-blind, placebo-controlled randomized clinical trial performed at 6 HHT centers of excellence. From August 2011 through March 2014, there were 121 adult patients who met the clinical criteria for HHT and had experienced HHT-related epistaxis with an Epistaxis Severity Score of at least 3.0. Follow-up was completed in September 2014. INTERVENTIONS: Patients received twice-daily nose sprays for 12 weeks with either bevacizumab 1% (4 mg/d), estriol 0.1% (0.4 mg/d), tranexamic acid 10% (40 mg/d), or placebo (0.9% saline). MAIN OUTCOMES AND MEASURES: The primary outcome was median weekly epistaxis frequency during weeks 5 through 12. Secondary outcomes included median duration of epistaxis during weeks 5 through 12, Epistaxis Severity Score, level of hemoglobin, level of ferritin, need for transfusion, emergency department visits, and treatment failure. RESULTS: Among the 121 patients who were randomized (mean age, 52.8 years [SD, 12.9 years]; 44% women with a median of 7.0 weekly episodes of epistaxis [interquartile range {IQR}, 3.0-14.0]), 106 patients completed the study duration for the primary outcome measure (43 were women [41%]). Drug therapy did not significantly reduce epistaxis frequency (P = .97). After 12 weeks of treatment, the median weekly number of bleeding episodes was 7.0 (IQR, 4.5-10.5) for patients in the bevacizumab group, 8.0 (IQR, 4.0-12.0) for the estriol group, 7.5 (IQR, 3.0-11.0) for the tranexamic acid group, and 8.0 (IQR, 3.0-14.0) for the placebo group. No drug treatment was significantly different from placebo for epistaxis duration. All groups had a significant improvement in Epistaxis Severity Score at weeks 12 and 24. There were no significant differences between groups for hemoglobin level, ferritin level, treatment failure, need for transfusion, or emergency department visits. CONCLUSIONS AND RELEVANCE: Among patients with HHT, there were no significant between-group differences in the use of topical intranasal treatment with bevacizumab vs estriol vs tranexamic acid vs placebo and epistaxis frequency. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT01408030.


Assuntos
Inibidores da Angiogênese/administração & dosagem , Bevacizumab/administração & dosagem , Epistaxe/tratamento farmacológico , Telangiectasia Hemorrágica Hereditária/complicações , Administração Intranasal , Administração Tópica , Adulto , Idoso , Antifibrinolíticos/administração & dosagem , Transfusão de Sangue , Método Duplo-Cego , Epistaxe/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Índice de Gravidade de Doença , Ácido Tranexâmico/administração & dosagem , Resultado do Tratamento
19.
J Vasc Interv Radiol ; 26(1): 107-10, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25541448

RESUMO

The loop snare technique is a method for inferior vena cava (IVC) filter retrieval that creates a wire loop between the filter legs; this technique may fail in cases with an embedded hook. This report describes the hangman technique, a modified loop snare technique for filter retrieval that creates a wire loop between the filter neck and IVC wall for release of embedded filter hooks. The hangman technique was attempted in 11 cases complicated by tilt (mean tilt, 13.3 degrees ± 3.9) and an embedded hook (mean dwell time, 194.5 d) with a retrieval success rate of 81.8% (9 of 11 cases) and no associated complications.


Assuntos
Remoção de Dispositivo/métodos , Filtros de Veia Cava , Veia Cava Inferior/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Flebografia , Estudos Retrospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA