RESUMO
AIMS: This study aims to identify and visualize electrocardiogram (ECG) features using an explainable deep learning-based algorithm to predict cardiac resynchronization therapy (CRT) outcome. Its performance is compared with current guideline ECG criteria and QRSAREA. METHODS AND RESULTS: A deep learning algorithm, trained on 1.1 million ECGs from 251 473 patients, was used to compress the median beat ECG, thereby summarizing most ECG features into only 21 explainable factors (FactorECG). Pre-implantation ECGs of 1306 CRT patients from three academic centres were converted into their respective FactorECG. FactorECG predicted the combined clinical endpoint of death, left ventricular assist device, or heart transplantation [c-statistic 0.69, 95% confidence interval (CI) 0.66-0.72], significantly outperforming QRSAREA and guideline ECG criteria [c-statistic 0.61 (95% CI 0.58-0.64) and 0.57 (95% CI 0.54-0.60), P < 0.001 for both]. The addition of 13 clinical variables was of limited added value for the FactorECG model when compared with QRSAREA (Δ c-statistic 0.03 vs. 0.10). FactorECG identified inferolateral T-wave inversion, smaller right precordial S- and T-wave amplitude, ventricular rate, and increased PR interval and P-wave duration to be important predictors for poor outcome. An online visualization tool was created to provide interactive visualizations (https://crt.ecgx.ai). CONCLUSION: Requiring only a standard 12-lead ECG, FactorECG held superior discriminative ability for the prediction of clinical outcome when compared with guideline criteria and QRSAREA, without requiring additional clinical variables. End-to-end automated visualization of ECG features allows for an explainable algorithm, which may facilitate rapid uptake of this personalized decision-making tool in CRT.
Assuntos
Terapia de Ressincronização Cardíaca , Aprendizado Profundo , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Resultado do Tratamento , Eletrocardiografia , Arritmias Cardíacas/terapiaRESUMO
INTRODUCTION: We aimed to investigate the impact of the 2021 European Society of Cardiology (ESC) guideline changes in left bundle branch block (LBBB) definition on cardiac resynchronization therapy (CRT) patient selection and outcomes. METHODS: The MUG (Maastricht, Utrecht, Groningen) registry, consisting of consecutive patients implanted with a CRT device between 2001 and 2015 was studied. For this study, patients with baseline sinus rhythm and QRS duration ≥ 130ms were eligible. Patients were classified according to ESC 2013 and 2021 guideline LBBB definitions and QRS duration. Endpoints were heart transplantation, LVAD implantation or mortality (HTx/LVAD/mortality) and echocardiographic response (LVESV reduction ≥15%). RESULTS: The analyses included 1.202, typical CRT patients. The ESC 2021 definition resulted in considerably less LBBB diagnoses compared to the 2013 definition (31.6% vs. 80.9%, respectively). Applying the 2013 definition resulted in significant separation of the Kaplan-Meier curves of HTx/LVAD/mortality (p < .0001). A significantly higher echocardiographic response rate was found in the LBBB compared to the non-LBBB group using the 2013 definition. These differences in HTx/LVAD/mortality and echocardiographic response were not found when applying the 2021 definition. CONCLUSION: The ESC 2021 LBBB definition leads to a considerably lower percentage of patients with baseline LBBB then the ESC 2013 definition. This does not lead to better differentiation of CRT responders, nor does this lead to a stronger association with clinical outcomes after CRT. In fact, stratification according to the 2021 definition is not associated with a difference in clinical or echocardiographic outcome, implying that the guideline changes may negatively influence CRT implantation practice with a weakened recommendation in patients that will benefit from CRT.
Assuntos
Terapia de Ressincronização Cardíaca , Cardiologia , Humanos , Bloqueio de Ramo/diagnóstico , Terapia de Ressincronização Cardíaca/métodos , Resultado do Tratamento , Eletrocardiografia/métodos , Arritmias Cardíacas/terapia , EcocardiografiaRESUMO
AIMS: Altered ventricular activation (AVA) causes intraventricular mechanical dyssynchrony (MD) and impedes contraction, promoting pro-arrhythmic electrical remodelling in the chronic atrioventricular block (CAVB) dog. We aimed to study arrhythmogenic and electromechanical outcomes of different degrees of AVA. METHODS AND RESULTS: Following atrioventricular block, AVA was established through idioventricular rhythm (IVR; n = 29), right ventricular apex (RVA; n = 12) pacing or biventricular pacing [cardiac resynchronization therapy (CRT); n = 10]. After ≥3 weeks of bradycardic remodelling, Torsade de Pointes arrhythmia (TdP) inducibility, defined as ≥3 TdP/10 min, was tested with specific IKr-blocker dofetilide (25 µg/kg/5 min). Mechanical dyssynchrony was assessed by echocardiography as time-to-peak (TTP) of left ventricular (LV) free-wall minus septum (ΔTTP). Electrical intraventricular dyssynchrony was assessed as slope of regression line correlating intraventricular LV activation time (AT) and activation recovery interval (ARI). Under sinus rhythm, contraction occurred synchronous (ΔTTP: -8.6 ± 28.9 ms), and latest activated regions seemingly had slightly longer repolarization (AT-ARI slope: -0.4). Acute AV block increased MD in all groups, but following ≥3 weeks of remodelling IVR animals became significantly more TdP inducible (19/29 IVR vs. 5/12 RVA and 2/10 CRT, both P < 0.05 vs. IVR). After chronic AVA, intraventricular MD was lowest in CRT animals (ΔTTP: -8.5 ± 31.2 vs. 55.80 ± 20.0 and 82.7 ± 106.2 ms in CRT, IVR, and RVA, respectively, P < 0.05 RVA vs. CRT). Although dofetilide steepened negative AT-ARI slope in all groups, this heterogeneity in dofetilide-induced ARI prolongation seemed least pronounced in CRT animals (slope to -0.8, -3.2 and -4.5 in CRT, IVR and RVA, respectively). CONCLUSION: Severity of intraventricular MD affects the extent of electrical remodelling and pro-arrhythmic outcome in the CAVB dog model.
Assuntos
Remodelamento Atrial , Bloqueio Atrioventricular , Terapia de Ressincronização Cardíaca , Cães , Animais , Coração , Arritmias Cardíacas/etiologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Proteínas de Ligação a DNARESUMO
AIMS: Data on repolarization parameters in cardiac resynchronization therapy (CRT) are scarce. We investigated the association of baseline T-wave area, with both clinical and echocardiographic outcomes of CRT in a large, multi-centre cohort of CRT recipients. Also, we evaluated the association between the baseline T-wave area and QRS area. METHODS AND RESULTS: In this retrospective study, 1355 consecutive CRT recipients were evaluated. Pre-implantation T-wave and QRS area were calculated from vectorcardiograms. Echocardiographic response was defined as a reduction of ≥15% in left ventricular end-systolic volume between 3 and 12 months after implantation. The clinical outcome was a combination of all-cause mortality, heart transplantation, and left ventricular assist device implantation. Left ventricular end-systolic volume reduction was largest in patients with QRS area ≥ 109â µVs and T-wave area ≥ 66â µVs compared with QRS area ≥ 109â µVs and T-wave area < 66â µVs (P = 0.004), QRS area < 109â µVs and T-wave area ≥ 66â µVs (P < 0.001) and QRS area < 109â µVs and T-wave area < 66â µVs (P < 0.001). Event-free survival rate was higher in the subgroup of patients with QRS area ≥ 109â µVs and T-wave area ≥ 66â µVs (n = 616, P < 0.001) and QRS area ≥ 109â µVs and T-wave area < 66â µVs (n = 100, P < 0.001) than the other subgroups. In the multivariate analysis, T-wave area remained associated with echocardiographic response (P = 0.008), but not with the clinical outcome (P = 0.143), when QRS area was included in the model. CONCLUSION: Baseline T-wave area has a significant association with both clinical and echocardiographic outcomes after CRT. The association of T-wave area with echocardiographic response is independent from QRS area; the association with clinical outcome, however, is not.
Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Resultado do Tratamento , Estudos Retrospectivos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Bloqueio de Ramo , Eletrocardiografia/métodos , Ecocardiografia , Arritmias Cardíacas/terapia , Volume Sistólico/fisiologiaRESUMO
AIMS: Identifying heart failure (HF) patients who will benefit from cardiac resynchronization therapy (CRT) remains challenging. We evaluated whether virtual pacing in a digital twin (DT) of the patient's heart could be used to predict the degree of left ventricular (LV) reverse remodelling post-CRT. METHODS AND RESULTS: Forty-five HF patients with wide QRS complex (≥130â ms) and reduced LV ejection fraction (≤35%) receiving CRT were retrospectively enrolled. Echocardiography was performed before (baseline) and 6 months after CRT implantation to obtain LV volumes and 18-segment longitudinal strain. A previously developed algorithm was used to generate 45 DTs by personalizing the CircAdapt model to each patient's baseline measurements. From each DT, baseline septal-to-lateral myocardial work difference (MWLW-S,DT) and maximum rate of LV systolic pressure rise (dP/dtmax,DT) were derived. Biventricular pacing was then simulated using patient-specific atrioventricular delay and lead location. Virtual pacing-induced changes ΔMWLW-S,DT and ΔdP/dtmax,DT were correlated with real-world LV end-systolic volume change at 6-month follow-up (ΔLVESV). The DT's baseline MWLW-S,DT and virtual pacing-induced ΔMWLW-S,DT were both significantly associated with the real patient's reverse remodelling ΔLVESV (r = -0.60, P < 0.001 and r = 0.62, P < 0.001, respectively), while correlation between ΔdP/dtmax,DT and ΔLVESV was considerably weaker (r = -0.34, P = 0.02). CONCLUSION: Our results suggest that the reduction of septal-to-lateral work imbalance by virtual pacing in the DT can predict real-world post-CRT LV reverse remodelling. This DT approach could prove to be an additional tool in selecting HF patients for CRT and has the potential to provide valuable insights in optimization of CRT delivery.
Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Estudos Retrospectivos , Resultado do Tratamento , Ecocardiografia , Dispositivos de Terapia de Ressincronização Cardíaca , Função Ventricular Esquerda/fisiologia , Remodelação Ventricular , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapiaRESUMO
AIMS: An automated method for determination of short-term variability (STV) of repolarization on intracardiac electrograms (STV-ARIauto) has previously been developed for arrhythmic risk monitoring by cardiac implantable devices, and has proved effective in predicting ventricular arrhythmias (VA) and guiding preventive high-rate pacing (HRP) in a canine model. Current study aimed to assess (i) STV-ARIauto in relation to VA occurrence and secondarily (ii-a) to confirm the predictive capacity of STV from the QT interval and (ii-b) explore the effect of HRP on arrhythmic outcomes in a porcine model of acute myocardial infarction (MI). METHODS AND RESULTS: Myocardial infarction was induced in 15 pigs. In 7/15 pigs, STV-QT was assessed at baseline, occlusion, 1â min before VA, and just before VA. Eight of the 15 pigs were additionally monitored with an electrogram catheter in the right ventricle, underwent echocardiography at baseline and reperfusion, and were randomized to paced or control group. Paced group received atrial pacing at 20â beatsâ perâ min faster than sinus rhythm 1â min after occlusion. Short-term variability increased prior to VA in both STV modalities. The percentage change in STV from baseline to successive timepoints correlated well between STV-QT and STV-ARIauto. High-rate pacing did not improve arrhythmic outcomes and was accompanied by a stronger decrease in ejection fraction. CONCLUSION: STV-ARIauto values increase before VA onset, alike STV-QT in a porcine model of MI, indicating imminent arrhythmias. This highlights the potential of automatic monitoring of arrhythmic risk by cardiac devices through STV-ARIauto and subsequently initiates preventive strategies. Continuous HRP during onset of acute MI did not improve arrhythmic outcomes.
Assuntos
Doença da Artéria Coronariana , Isquemia Miocárdica , Animais , Cães , Suínos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/prevenção & controle , Isquemia Miocárdica/complicações , Ventrículos do Coração , Isquemia/complicações , EletrocardiografiaRESUMO
AIMS: Pacing remote from the latest electrically activated site (LEAS) in the left ventricle (LV) may diminish response to cardiac resynchronization therapy (CRT). We tested whether proximity of LV pacing site (LVPS) to LEAS, determined by non-invasive three-dimensional electrical activation mapping [electrocardiographic Imaging (ECGI)], increased likelihood of CRT response. METHODS AND RESULTS: Consecutive CRT patients underwent ECGI and chest/heart computed tomography 6-24 months of post-implant. Latest electrically activated site and the distance to LVPS (dp) were assessed. Left ventricular end-systolic volume (LVESV) reduction of ≥15% at clinical follow-up defined response. Logistic regression probabilistically modelled non-response; variables included demographics, heart failure classification, left bundle branch block (LBBB), ischaemic heart disease (IHD), atrial fibrillation, QRS duration, baseline ejection fraction (EF) and LVESV, comorbidities, use of CRT optimization algorithm, angiotensin-converting enzyme inhibitor(ACE)/angiotensin-receptor blocker (ARB), beta-blocker, diuretics, and dp. Of 111 studied patients [64 ± 11 years, EF 28 ± 6%, implant duration 12 ± 5 months (mean ± SD), 98% had LBBB, 38% IHD], 67% responded at 10 ± 3 months post CRT-implant. Latest electrically activated sites were outside the mid-to-basal lateral segments in 35% of the patients. dp was 42 ± 23 mm [31 ± 14 mm for responders vs. 63 ± 24 mm non-responders (P < 0.001)]. Longer dp and the lack of use of CRT optimization algorithm were the only independent predictors of non-response [area under the curve (AUC) 0.906]. dp of 47 mm delineated responders and non-responders (AUC 0.931). CONCLUSION: The distance between LV pacing site and latest electrical activation is a strong independent predictor for CRT response. Non-invasive electrical evaluation to characterize intrinsic activation and guide LV lead deployment may improve CRT efficacy.
Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Ventrículos do Coração/diagnóstico por imagem , Antagonistas de Receptores de Angiotensina , Inibidores da Enzima Conversora de Angiotensina , Eletrocardiografia/métodos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Arritmias Cardíacas/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Resultado do Tratamento , Função Ventricular EsquerdaRESUMO
AIMS: Remote patient monitoring (RPM) systems offer a promising alternative to conventional In-Clinic check-ups, hereby reducing unnecessary clinic visits. Especially with the rise of the COVID-19 pandemic, this reduction is of paramount importance. Regarding the association between RPM and clinical outcomes, findings of previous studies have been inconsistent. The aim of this study is to elucidate the effect of partly substituting In-Clinic visits by RPM on clinical outcomes in implantable cardioverter-defibrillator (ICD) patients. METHODS AND RESULTS: The study included 595 heart failure patients (LVEF ≤35%; NYHA Class II/III) implanted with an ICD compatible with the Boston Scientific LATITUDE™ system. Participants were randomized to RPM plus an annual In-Clinic visit or 3-6 months In-Clinic check-ups alone. The investigated endpoints after 2 years of follow-up included a composite of all-cause mortality and cardiac hospitalization, mortality and cardiac hospitalization as independent endpoints and ICD therapy. The incidence of mortality and hospitalization did not differ significantly as independent, nor as composite endpoint between the RPM and In-Clinic group (all Ps <0.05). The results were similar regarding ICD therapy, except for appropriate ICD therapy (odds ratio 0.50; 95% confidence interval 0.26-0.98; P = 0.04). Exploratory subgroup analyses indicated that the effect of RPM differs between patients with specific characteristics, i.e. ≥60 years and permanent atrial fibrillation (all Ps < 0.05). CONCLUSION: RPM is non-inferior to conventional In-Clinic visits regarding clinical outcomes. Routine In-Clinic follow-up may partly be substituted by RPM without jeopardizing safety and efficiency, and thus reducing unnecessary In-Clinic visits. CLINICALTRIALS.GOV IDENTIFIER: NCT01691586.
Assuntos
COVID-19 , Desfibriladores Implantáveis , Insuficiência Cardíaca , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Pandemias , SARS-CoV-2RESUMO
AIMS: While electrocardiogram (ECG) characteristics have been associated with life-threatening ventricular arrhythmias (LTVA) in dilated cardiomyopathy (DCM), they typically rely on human-derived parameters. Deep neural networks (DNNs) can discover complex ECG patterns, but the interpretation is hampered by their 'black-box' characteristics. We aimed to detect DCM patients at risk of LTVA using an inherently explainable DNN. METHODS AND RESULTS: In this two-phase study, we first developed a variational autoencoder DNN on more than 1 million 12-lead median beat ECGs, compressing the ECG into 21 different factors (F): FactorECG. Next, we used two cohorts with a combined total of 695 DCM patients and entered these factors in a Cox regression for the composite LTVA outcome, which was defined as sudden cardiac arrest, spontaneous sustained ventricular tachycardia, or implantable cardioverter-defibrillator treated ventricular arrhythmia. Most patients were male (n = 442, 64%) with a median age of 54 years [interquartile range (IQR) 44-62], and median left ventricular ejection fraction of 30% (IQR 23-39). A total of 115 patients (16.5%) reached the study outcome. Factors F8 (prolonged PR-interval and P-wave duration, P < 0.005), F15 (reduced P-wave height, P = 0.04), F25 (increased right bundle branch delay, P = 0.02), F27 (P-wave axis P < 0.005), and F32 (reduced QRS-T voltages P = 0.03) were significantly associated with LTVA. CONCLUSION: Inherently explainable DNNs can detect patients at risk of LTVA which is mainly driven by P-wave abnormalities.
Assuntos
Cardiomiopatia Dilatada , Desfibriladores Implantáveis , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/diagnóstico , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Eletrocardiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Redes Neurais de Computação , Fatores de Risco , Volume Sistólico , Função Ventricular Esquerda/fisiologiaRESUMO
AIMS: Investigate haemodynamic effects, and their mechanisms, of restoring atrioventricular (AV)-coupling using pacemaker therapy in normal and failing hearts in a combined computational-experimental-clinical study. METHODS AND RESULTS: Computer simulations were performed in the CircAdapt model of the normal and failing human heart and circulation. Experiments were performed in a porcine model of AV dromotropathy. In a proof-of-principle clinical study, left ventricular (LV) pressure and volume were measured in 22 heart failure (HF) patients (LV ejection fraction <35%) with prolonged PR interval (>230 ms) and narrow or non-left bundle branch block QRS complex. Computer simulations and animal studies in normal hearts showed that restoring of AV-coupling with unchanged ventricular activation sequence significantly increased LV filling, mean arterial pressure, and cardiac output by 10-15%. In computer simulations of failing hearts and in HF patients, reducing PR interval by biventricular (BiV) pacing (patients: from 300 ± 61 to 137 ± 30 ms) resulted in significant increases in LV stroke volume and stroke work (patients: 34 ± 40% and 26 ± 31%, respectively). However, worsening of ventricular dyssynchrony by using right ventricular (RV) pacing abrogated the benefit of restoring AV-coupling. In model simulations, animals and patients, the increase of LV filling and associated improvement of LV pump function coincided with both larger mitral inflow (E- and A-wave area) and reduction of diastolic mitral regurgitation. CONCLUSION: Restoration of AV-coupling by BiV pacing in normal and failing hearts with prolonged AV conduction leads to considerable haemodynamic improvement. These results indicate that BiV or physiological pacing, but not RV pacing, may improve cardiac function in patients with HF and prolonged PR interval.
Assuntos
Bloqueio Atrioventricular , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Animais , Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca/métodos , Ventrículos do Coração , Humanos , Volume Sistólico , Suínos , Função Ventricular Esquerda/fisiologiaRESUMO
INTRODUCTION: Recent studies have shown that the baseline QRS area is associated with the clinical response after cardiac resynchronization therapy (CRT). In this study, we investigated the association of QRS area reduction (∆QRS area) after CRT with the outcome. We hypothesize that a larger ∆QRS area is associated with a better survival and echocardiographic response. METHODS AND RESULTS: Electrocardiograms (ECG) obtained before and 2-12 months after CRT from 1299 patients in a multi-center CRT-registry were analyzed. The QRS area was calculated from vectorcardiograms that were synthesized from 12-lead ECGs. The primary endpoint was a combination of all-cause mortality, heart transplantation, and left ventricular (LV) assist device implantation. The secondary endpoint was the echocardiographic response, defined as LV end-systolic volume reduction ≥ of 15%. Patients with ∆QRS area above the optimal cut-off value (62 µVs) had a lower risk of reaching the primary endpoint (hazard ratio: 0.43; confidence interval [CI] 0.33-0.56, p < .001), and a higher chance of echocardiographic response (odds ratio [OR] 3.3;CI 2.4-4.6, p < .0001). In multivariable analysis, ∆QRS area was independently associated with both endpoints. In patients with baseline QRS area ≥109 µVs, survival, and echocardiographic response were better when the ∆QRS area was ≥62 µVs (p < .0001). Logistic regression showed that in patients with baseline QRS area ≥109 µVs, ∆QRS area was the only significant predictor of survival (OR: 0.981; CI: 0.967-0.994, p = .006). CONCLUSION: ∆QRS area is an independent determinant of CRT response, especially in patients with a large baseline QRS area. Failure to achieve a large QRS area reduction with CRT is associated with a poor clinical outcome.
Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Ecocardiografia , Eletrocardiografia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Estudos Retrospectivos , Volume Sistólico , Resultado do TratamentoRESUMO
BACKGROUND: Segment length in cine (SLICE) strain analysis on standard cardiovascular magnetic resonance (CMR) cine images was recently validated against gold standard myocardial tagging. The present study aims to explore predictive value of SLICE for cardiac resynchronization therapy (CRT) response. METHODS AND RESULTS: Fifty-seven patients with heart failure and left bundle branch block (LBBB) were prospectively enrolled in this multi-center study and underwent CMR examination before CRT implantation. Circumferential strains of the septal and lateral wall were measured by SLICE on short-axis cine images. In addition, timing and strain pattern parameters were assessed. After twelve months, CRT response was quantified by the echocardiographic change in left ventricular (LV) end-systolic volume (LVESV). In contrast to timing parameters, strain pattern parameters being systolic rebound stretch of the septum (SRSsep), systolic stretch index (SSIsep-lat), and internal stretch factor (ISFsep-lat) all correlated significantly with LVESV change (R - 0.56; R - 0.53; and R - 0.58, respectively). Of all strain parameters, end-systolic septal strain (ESSsep) showed strongest correlation with LVESV change (R - 0.63). Multivariable analysis showed ESSsep to be independently related to LVESV change together with age and QRSAREA. CONCLUSION: The practicable SLICE strain technique may help the clinician to estimate potential benefit from CRT by analyzing standard CMR cine images without the need for commercial software. Of all strain parameters, end-systolic septal strain (ESSsep) demonstrates the strongest correlation with reverse remodeling after CRT. This parameter may be of special interest in patients with non-strict LBBB morphology for whom CRT benefit is doubted.
Assuntos
Bloqueio de Ramo/diagnóstico por imagem , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Idoso , Idoso de 80 Anos ou mais , Bloqueio de Ramo/fisiopatologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Tomada de Decisão Clínica , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do TratamentoRESUMO
AIMS: This study was performed to develop and externally validate prediction models for appropriate implantable cardioverter-defibrillator (ICD) shock and mortality to identify subgroups with insufficient benefit from ICD implantation. METHODS AND RESULTS: We recruited patients scheduled for primary prevention ICD implantation and reduced left ventricular function. Bootstrapping-based Cox proportional hazards and Fine and Gray competing risk models with likely candidate predictors were developed for all-cause mortality and appropriate ICD shock, respectively. Between 2014 and 2018, we included 1441 consecutive patients in the development and 1450 patients in the validation cohort. During a median follow-up of 2.4 (IQR 2.1-2.8) years, 109 (7.6%) patients received appropriate ICD shock and 193 (13.4%) died in the development cohort. During a median follow-up of 2.7 (IQR 2.0-3.4) years, 105 (7.2%) received appropriate ICD shock and 223 (15.4%) died in the validation cohort. Selected predictors of appropriate ICD shock were gender, NSVT, ACE/ARB use, atrial fibrillation history, Aldosterone-antagonist use, Digoxin use, eGFR, (N)OAC use, and peripheral vascular disease. Selected predictors of all-cause mortality were age, diuretic use, sodium, NT-pro-BNP, and ACE/ARB use. C-statistic was 0.61 and 0.60 at respectively internal and external validation for appropriate ICD shock and 0.74 at both internal and external validation for mortality. CONCLUSION: Although this cohort study was specifically designed to develop prediction models, risk stratification still remains challenging and no large group with insufficient benefit of ICD implantation was found. However, the prediction models have some clinical utility as we present several scenarios where ICD implantation might be postponed.
Assuntos
Desfibriladores Implantáveis , Antagonistas de Receptores de Angiotensina , Inibidores da Enzima Conversora de Angiotensina , Estudos de Coortes , Morte Súbita Cardíaca/prevenção & controle , Humanos , Prevenção Primária , Fatores de RiscoRESUMO
BACKGROUND: Cardiac resynchronization therapy (CRT) is an established treatment in patients with heart failure and conduction abnormalities. However, a significant number of patients do not respond to CRT. Currently employed criteria for selection of patients for this therapy (QRS duration and morphology) have several shortcomings. QRS area was recently shown to provide superior association with CRT response. However, its assessment was not fully automated and required the presence of an expert. OBJECTIVE: Our objective was to develop a fully automated method for the assessment of vector-cardiographic (VCG) QRS area from electrocardiographic (ECG) signals. METHODS: Pre-implantation ECG recordings (Nâ¯=â¯864, 695 left-bundle-branch block, 589 men) in PDF files were converted to allow signal processing. QRS complexes were found and clustered into morphological groups. Signals were converted from 12lead ECG to 3lead VCG and an average QRS complex was built. QRS area was computed from individual areas in the X, Y and Z leads. Practical usability was evaluated using Kaplan-Meier plots and 5-year follow-up data. RESULTS: The automatically calculated QRS area values were 123⯱â¯48⯵V.s (mean values and SD), while the manually determined QRS area values were 116⯱â¯51â¯ms; the correlation coefficient between the two was râ¯=â¯0.97. The automated and manual methods showed the same ability to stratify the population (hazard ratios 2.09 vs 2.03, respectively). CONCLUSION: The presented approach allows the fully automatic and objective assessment of QRS area values. SIGNIFICANCE: Until this study, assessing QRS area values required an expert, which means both additional costs and a risk of subjectivity. The presented approach eliminates these disadvantages and is publicly available as part of free signal-processing software.
Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Eletrocardiografia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Masculino , Resultado do Tratamento , VetorcardiografiaRESUMO
AIMS: This study aims to define an atrioventricular (AV) delay optimization method for cardiac resynchronization therapy (CRT) with a quadripolar left ventricular (LV) lead based on intrinsic conduction intervals. METHODS AND RESULTS: Heart failure patients with a left bundle branch block underwent CRT implantation with a quadripolar LV lead. Invasive LV pressure-volume loops were recorded during four biventricular and three multi-point pacing (MPP) settings, using four patient-specific paced AV delays. Haemodynamic response was defined as change in stroke work (Δ%SW) compared to intrinsic rhythm and was related to the following conduction intervals: right atrial pacing to right ventricular sensing interval (RAp-RVs), Q to LV sensing interval normalized to QRS duration (QLV/QRSd), PR-interval, and P-wave duration. In 44 patients, the largest Δ%SW (104 ± 76%) occurred at a paced AV delay of 128 ± 32 ms, at 47 ± 9% of RAp-RVs. Optimal AV delay of biventricular pacing (126 ± 26 ms) did not differ from MPP (126 ± 21 ms, P = 0.29). Intra-class correlation coefficient between optimal AV delays of different pacing configurations was 0.64 (0.45-0.78, P < 0.001). Although not statistically significant, Δ%SW at 50% of RAp-RVs (98 ± 74%) was closer to the maximal achievable Δ%SW increase than a fixed interval of 120 ms (96 ± 73%, P = 0.60). RAp-RVs, QLV/QRSd, PR interval, and P-wave duration were associated with the optimal AV delay in univariate analysis, but only RAp-RVs remained significantly associated in multivariate analysis (R = 0.69). CONCLUSION: The AV delay that provides highest haemodynamic response is similar for various LV pacing configurations and for MPP. An AV delay â¼50% of RAp-RVs creates an acute haemodynamic response close to the maximal patient-specific response.
Assuntos
Fascículo Atrioventricular/fisiopatologia , Bloqueio de Ramo/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Função Ventricular Esquerda , Potenciais de Ação , Idoso , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Fatores de Tempo , Resultado do Tratamento , Pressão VentricularRESUMO
AIMS: The European REMOTE-CIED study is the first randomized trial primarily designed to evaluate the effect of remote patient monitoring (RPM) on patient-reported outcomes in the first 2 years after implantation of an implantable cardioverter-defibrillator (ICD). METHODS AND RESULTS: The sample consisted of 595 European heart failure patients implanted with an ICD compatible with the Boston Scientific LATITUDE® RPM system. Patients were randomized to RPM plus a yearly in-clinic ICD check-up vs. 3-6-month in-clinic check-ups alone. At five points during the 2-year follow-up, patients completed questionnaires including the Kansas City Cardiomyopathy Questionnaire and Florida Patient Acceptance Survey (FPAS) to assess their heart failure-specific health status and ICD acceptance, respectively. Information on clinical status was obtained from patients' medical records. Linear regression models were used to compare scores between groups over time. Intention-to-treat and per-protocol analyses showed no significant group differences in patients' health status and ICD acceptance (subscale) scores (all Ps > 0.05). Exploratory subgroup analyses indicated a temporary improvement in device acceptance (FPAS total score) at 6-month follow-up for secondary prophylactic in-clinic patients only (P < 0.001). No other significant subgroup differences were observed. CONCLUSION: Large clinical trials have indicated that RPM can safely and effectively replace most in-clinic check-ups of ICD patients. The REMOTE-CIED trial results show that patient-reported health status and ICD acceptance do not differ between patients on RPM and patients receiving in-clinic check-ups alone in the first 2 years after ICD implantation.ClinicalTrials.gov Identifier: NCT01691586.
Assuntos
Assistência Ambulatorial/métodos , Monitorização Ambulatorial da Pressão Arterial , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Eletrocardiografia , Insuficiência Cardíaca/terapia , Medidas de Resultados Relatados pelo Paciente , Qualidade de Vida , Tecnologia de Sensoriamento Remoto/métodos , Assistência ao Convalescente , Idoso , Peso Corporal , Cardiologia , Falha de Equipamento , Europa (Continente) , Feminino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/psicologia , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Prevenção Primária , Prevenção SecundáriaRESUMO
BACKGROUND: Patient satisfaction with remote patient monitoring (RPM) of implantable cardioverter defibrillators (ICDs) seems to be high, yet knowledge on long-term patient experiences is limited. The European REMOTE-CIED study explored patients' experiences with RPM, examined patient's preferences for ICD follow-up, and identified determinants of patient's preferences in the first 2 years postimplantation. METHODS: European heart failure patients (N = 300; median age = 66 years [interquartile range (IQR) = 59-73], and 22% female) with a first-time ICD received a Boston Scientific LATITUDE RPM system (Marlborough, MA, USA) and had scheduled in-clinic follow-ups once a year. Patients completed questionnaires at 1-2 weeks and also at 3, 6, 12, and 24 months postimplantation and clinical data were obtained from their medical records. Patient evaluation data were analyzed descriptively, and Student's t-tests/Man-Whitney U tests or Chi-square tests/Fisher's exact tests were performed to examine determinants of patient preferences. RESULTS: At 2 years postimplantation, the median patient satisfaction score with the RPM system was 9 out of 10 (IQR = 8-10), despite 53% of the patients experiencing issues (eg, failure to transmit data). Of the 221 patients who reported their follow-up preferences, 43% preferred RPM and 19% preferred in-clinic follow-up. Patients with a preference for RPM were more likely to be higher educated (P = 0.04), employed (P = 0.04), and equipped with a new LATITUDE model (P = 0.04), but less likely to suffer from chronic obstructive pulmonary disease (P = 0.009). CONCLUSION: In general, patients were highly satisfied with RPM, but a subgroup preferred in-clinic follow-up. Therefore, physicians should include patients' concerns and preferences in the decision-making process, to tailor device follow-up to individual patients' needs and preferences.
Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca/terapia , Monitorização Fisiológica/métodos , Satisfação do Paciente , Telemedicina , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Preferência do Paciente , Autorrelato , Inquéritos e QuestionáriosRESUMO
Aims: Cardiac resynchronization therapy (CRT) reduces morbidity and mortality in systolic heart failure patients with ventricular conduction delay. Variability of individual response to CRT warrants improved patient selection. The Markers and Response to CRT (MARC) study was designed to investigate markers related to response to CRT. Methods and results: We prospectively studied the ability of 11 clinical, 11 electrocardiographic, 4 echocardiographic, and 16 blood biomarkers to predict CRT response in 240 patients. Response was measured by the reduction of indexed left ventricular end-systolic volume (LVESVi) at 6 months follow-up. Biomarkers were related to LVESVi change using log-linear regression on continuous scale. Covariates that were significant univariately were included in a multivariable model. The final model was utilized to compose a response score. Age was 67 ± 10 years, 63% were male, 46% had ischaemic aetiology, LV ejection fraction was 26 ± 8%, LVESVi was 75 ± 31 mL/m2, and QRS was 178 ± 23 ms. At 6 months LVESVi was reduced to 58 ± 31 mL/m2 (relative reduction of 22 ± 24%), 130 patients (61%) showed ≥ 15% LVESVi reduction. In univariate analysis 17 parameters were significantly associated with LVESVi change. In the final model age, QRSAREA (using vectorcardiography) and two echocardiographic markers (interventricular mechanical delay and apical rocking) remained significantly associated with the amount of reverse ventricular remodelling. This CAVIAR (CRT-Age-Vectorcardiographic QRSAREA -Interventricular Mechanical delay-Apical Rocking) response score also predicted clinical outcome assessed by heart failure hospitalizations and all-cause mortality. Conclusions: The CAVIAR response score predicts the amount of reverse remodelling after CRT and may be used to improve patient selection. Clinical Trials: NCT01519908.
RESUMO
BACKGROUND: Driving restrictions for patients with an implantable cardioverter defibrillator (ICD) may require significant lifestyle adjustment and affect patients' psychological well-being. This study explored the prevalence of, and factors associated with, patient-reported decrease in quality of life due to driving restrictions in the first 2 months postimplantation. METHODS: Dutch ICD patients (N = 334; median age, 64 [interquartile range, 55-70) years; 81% male) completed questionnaires at the time of implantation and 4 months postimplantation, assessing their sociodemographic, psychological, and driving-related characteristics. Clinical baseline data were retrieved from patients' medical records. RESULTS: Nearly half of the patients (49%) reported decreased quality of life due to driving restrictions. Patient-reported reasons included dependency on others/public transport, (social) isolation, and inability to work. Patients reporting decreased quality of life were more likely to be younger (P = .01), to feel that the restriction lasts too long (P = .004), to have considered ICD refusal because of the restrictions (P = .03), and to have Type D personality (P = .02), anxiety (P = .05), depression (P = .003), and ICD-related concerns (P = .02). Multivariable analysis showed that being younger than 60 years (odds ratio [OR], 2.30; 95% confidence interval [CI], 1.09-4.88; P = .03), feeling the driving restriction lasts too long (OR, 1.77; 95% CI, 1.23-2.55; P = .002), and depression (OR, 3.21; 95% CI, 1.09-9.47; P = .035) were independently associated with decreased quality of life due to driving restrictions. CONCLUSIONS: This study indicated that a significant group of ICD patients may experience decreased quality of life because of the driving restrictions postimplantation. The restrictions seem to particularly affect patients who are younger and distressed and patients who feel that the restriction lasts too long.
Assuntos
Condução de Veículo/legislação & jurisprudência , Desfibriladores Implantáveis , Qualidade de Vida , Adaptação Psicológica , Fatores Etários , Idoso , Depressão/complicações , Feminino , Humanos , Estilo de Vida , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Inquéritos e QuestionáriosRESUMO
OBJECTIVES: Although myocardial strain analysis is a potential tool to improve patient selection for cardiac resynchronization therapy (CRT), there is currently no validated clinical approach to derive segmental strains. We evaluated the novel segment length in cine (SLICE) technique to derive segmental strains from standard cardiovascular MR (CMR) cine images in CRT candidates. METHODS: Twenty-seven patients with left bundle branch block underwent CMR examination including cine imaging and myocardial tagging (CMR-TAG). SLICE was performed by measuring segment length between anatomical landmarks throughout all phases on short-axis cines. This measure of frame-to-frame segment length change was compared to CMR-TAG circumferential strain measurements. Subsequently, conventional markers of CRT response were calculated. RESULTS: Segmental strains showed good to excellent agreement between SLICE and CMR-TAG (septum strain, intraclass correlation coefficient (ICC) 0.76; lateral wall strain, ICC 0.66). Conventional markers of CRT response also showed close agreement between both methods (ICC 0.61-0.78). Reproducibility of SLICE was excellent for intra-observer testing (all ICC ≥0.76) and good for interobserver testing (all ICC ≥0.61). CONCLUSIONS: The novel SLICE post-processing technique on standard CMR cine images offers both accurate and robust segmental strain measures compared to the 'gold standard' CMR-TAG technique, and has the advantage of being widely available. KEY POINTS: ⢠Myocardial strain analysis could potentially improve patient selection for CRT. ⢠Currently a well validated clinical approach to derive segmental strains is lacking. ⢠The novel SLICE technique derives segmental strains from standard CMR cine images. ⢠SLICE-derived strain markers of CRT response showed close agreement with CMR-TAG. ⢠Future studies will focus on the prognostic value of SLICE in CRT candidates.