Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Cardiovasc Dev Dis ; 11(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38667722

RESUMO

BACKGROUND: This study aims to understand and describe the clinical impact of SARS-CoV-2 (COVID-19) infection in patients with Hypertrophic Cardiomyopathy (HCM). METHODS: A data repository of over 6.6 million patients in a large metropolitan (Chicago IL) healthcare system was queried to identify adults with a history of HCM and COVID-19 infection between 2019 and 2021. Propensity score-matched analysis was performed based on age, sex, BMI, and elements of the cardiovascular history, including tobacco use, hypertension, hyperlipidemia, myocardial injury, and heart failure. RESULTS: Individuals with HCM and COVID-19 infection had more total hospitalizations (41.6 v 23 per 100 persons, p < 0.01), more heart-failure-related hospitalizations (24.2 v 8.7 per 100-persons, p < 0.01), more non-ST elevation myocardial injury (NSTEMI) hospitalizations (8.6 v 4.6 per 100-persons, p < 0.01), and increased mortality (10.8 v 5 per 100-persons, p < 0.01) compared to HCM patients without a history of COVID-19 infection. Patients with HCM and COVID-19 were also noted to have a higher peak CRP when compared to those without prior COVID-19 (Inter-quartile range of 9.0-106.9 v 1.8-21.3, p < 0.01). CONCLUSIONS: In patients with HCM, COVID-19 infection is associated with increased incidence of myocardial injury, increased number of total and heart-failure specific hospitalizations, and increased mortality.

2.
Struct Heart ; 8(2): 100264, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38481712

RESUMO

Background: Transcatheter mitral valve-in-valve (MViV) replacement has emerged as an alternative to redo mitral valve (MV) surgery for the management of failed bioprosthetic MVs. The degree of cardiac remodeling assessed by echocardiography has been shown to have prognostic implications in degenerative mitral regurgitation patients undergoing MV surgery. The impact of transcatheter MViV in patients with degenerative bioprosthetic MV failure on cardiac remodeling and its associated prognosis remains undescribed. Objectives: The aim of this study is to describe the early anatomic and functional changes of the left-sided chambers and right ventricle by echocardiography posttranscatheter MViV intervention and their impact on mortality outcomes. Additionally, we sought to analyze the outcome of heart failure in bioprosthetic MV failure patients undergoing transcatheter MViV replacement. Methods: We analyzed consecutive patients undergoing MViV intervention for symptomatic bioprosthetic MV failure. Echocardiograms before intervention and within 100 days postintervention were analyzed. A chart review was performed to obtain baseline characteristics, follow-up visits, 30-day heart failure and 1-year all-cause mortality outcomes. Results: A total of 62 patients (mean age 69 ± 13 years, 61% male) were included in the study. Most patients were undergoing MViV intervention for prosthetic mitral stenosis n = 48 (77.4%) and the rest for mitral regurgitation or mixed disease. Compared with baseline, significant reductions were observed in median left atrial volume (LAV; 103 [81-129] ml vs. 95.2 [74.5-117.5] ml, p < 0.01) and mean (SD) left atrial conduit strain (9.1% ± 5.2% vs. 10.8% ± 4.8%, p = 0.039) within 100 days postintervention. Early reduction in right ventricular free wall global longitudinal strain and fractional area change also occurred postintervention. No significant change in left ventricular chamber dimensions or ejection fraction was observed. During the 1-year follow up period, 5 (8%) patients died. While baseline LAV was not associated with 1-year all-cause mortality (OR 0.98 CI 0.95-1.01; p = 0.27), a change in LAV in the follow up period was associated with all-cause mortality at 1 year (OR 1.06 CI 1.01-1.12; p = 0.023). At 30 days postintervention, 65% of patients had an improvement in their New York Heart Association functional class. Conclusion: In this retrospective study of patients undergoing transcatheter MViV intervention for failed bioprosthetic MVs, early reverse remodeling of the left atrium occurs within 100 days postintervention and reduction in LAV is associated with reduced all-cause mortality at 1 year. In addition, there is significant improvement in heart failure symptoms at 30 days following intervention but further investigation into the longitudinal remodeling changes and long-term outcomes is needed.

3.
JACC Cardiovasc Imaging ; 17(7): 729-742, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38842961

RESUMO

BACKGROUND: Tricuspid valve transcatheter edge-to-edge repair (T-TEER) is the most widely used transcatheter therapy to treat patients with tricuspid regurgitation (TR). OBJECTIVES: The aim of this study was to develop a simple anatomical score to predict procedural outcomes of T-TEER. METHODS: All patients (n = 168) who underwent T-TEER between January 2017 and November 2022 at 2 centers were included in the derivation cohort. Additionally, 126 patients from 2 separate institutions served as a validation cohort. T-TEER was performed using 2 commercially available technologies. Core laboratory assessment of procedural transesophageal echocardiograms was used to determine septolateral and anteroposterior coaptation gap, leaflet morphology, septal leaflet length and retraction, chordal structure density, tethering height, en face TR jet morphology and TR jet location, image quality, and the presence of intracardiac leads. A scoring system was derived using univariable and multivariable logistic regression. Endpoints assessed were immediate postprocedural TR reduction ≥2 grades and TR grade moderate or less. RESULTS: The median age was 82 years (Q1-Q3: 78-84 years); 48% of patients were women; and patients presented with severe (55%), massive (36%), and torrential (8%) TR. Five variables (septolateral coaptation gap, chordal structure density, en face TR jet morphology, TR jet location, and image quality) were identified as best predicting procedural outcome and were incorporated in the GLIDE (Gap, Location, Image quality, density, en-face TR morphology) score (range 0-5). TR reduction ≥2 grades and TR grade moderate or less were observed in >90% of patients with GLIDE scores of 0 and 1 and in only 5.6% and 16.7% of those with GLIDE scores ≥4. The GLIDE score was then externally validated in a separate cohort (area under the curve: 0.77; 95% CI: 0.69-0.86). TR reduction significantly correlated with functional improvement assessed by NYHA functional class and 6-minute walk distance at 3 months. CONCLUSIONS: The GLIDE score is a simple, 5-component score that is readily obtained during patient imaging and can predict successful T-TEER.


Assuntos
Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Feminino , Masculino , Idoso , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Valva Tricúspide/cirurgia , Resultado do Tratamento , Idoso de 80 Anos ou mais , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Técnicas de Apoio para a Decisão , Medição de Risco , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA