Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Minim Invasive Ther Allied Technol ; 20(2): 78-84, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21417840

RESUMO

To date, transcatheter valve implantation is limited to the replacement of pulmonary and aortic valves. The aim of this study was to analyze a valved stent for minimally invasive implantation in the mitral position. A self-expanding mitral valved stent was designed for transapical implantation. Thirty pigs underwent off-pump mitral valved stent implantation with follow-up times of 60 minutes (n = 17) and seven days (n = 13). Transesophageal echocardiography and computed tomography were used to evaluate stent function and positioning. After valved stent deployment, accurate adjustment of the intra-annular position reduced paravalvular leakage in all animals. Accurate positioning was established in all but five animals. The average mean transvalvular gradient across the mitral valve and the left ventricular outflow tract recorded immediately after deployment, six hours and one week were 1.85 ± 0.95 mmHg, 3.45 ± 1.65 mmHg, 4.15 ± 2.3 mmHg and 1.35 ± 1.35 mmHg, 1.45 ± 0.7 mmHg, 1.9 ± 0.65 mmHg, respectively. No valved stent migration, embolization, systolic anterior movement or left ventricular outflow tract obstruction was observed. The mitral valved stent can be deployed in a reproducible manner to achieve reliable stent stability, minimal gradients across the left ventricular outflow tract and adequate stent function in acute and short term experimental settings.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Stents , Animais , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica , Valva Mitral/diagnóstico por imagem , Valva Mitral/patologia , Suínos , Tomografia Computadorizada por Raios X , Obstrução do Fluxo Ventricular Externo
2.
Interact Cardiovasc Thorac Surg ; 24(4): 527-533, 2017 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-28108573

RESUMO

Objectives: Despite recent achievements, implantation of a transcatheter mitral valved stent remains challenging. In this study, we present a different approach for implantation of a percutaneous mitral valved stent. Methods: Percutaneous transapical access is combined with, respectively, a left-transatrial, right-transatrial/transseptal or transfemoral/transseptal approach for mitral valve stent implantation and secure fixation. The apical fixation and occlusion are ensured with an Amplatzer occluder. This novel approach was tested in 22 porcine hearts in an in vitro setting under the guidance of fluoroscopy ( n = 11) and endoscopy ( n = 11). The in vitro setup included continuous flushing at 37 °C. We determined the feasibility, time of implantation, stent deployment and stent fixation. Results: Percutaneous mitral valved stent implantation was successful in all cases. Good handling properties and precise positioning were achieved. Time of implantation was comparable in the fluoroscopic and endoscopic groups at 10:41 ± 3:18 and 10:09 ± 2:42 min, respectively. Apical fixation with the occluder was excellent in all 22 cases. Conclusions: The feasibility of percutaneous mitral valved stent implantation has been demonstrated in preliminary in vitro experiments. Subsequent studies are warranted to determine the efficacy of this minimally invasive catheter-based mitral valved stent implantation.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Valva Mitral , Stents , Animais , Fluoroscopia , Técnicas de Cultura de Órgãos , Dispositivo para Oclusão Septal , Suínos
3.
Leuk Lymphoma ; 47(12): 2601-9, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17169805

RESUMO

In acute myeloid leukemia (AML), autocrine or paracrine activation of receptor tyrosine kinases such as c-kit and FLT3 contributes to proliferation and apoptosis resistance of leukemic blasts. This provided the rationale for a multicenter clinical trial in patients with refractory AML with SU5416, a small molecule kinase inhibitor which blocks phosphorylation of c-kit, FLT3, VEGFR-1, VEGFR-2 (KDR) and VEGFR-3. The levels of VEGF mRNA expression were investigated in peripheral blood leukemic blasts taken from AML patients before and during treatment with SU5416. Rapid down regulation of VEGF was observed in AML blasts from 72% (13 of 18) of patients analysed. Patients initially expressing high VEGF-levels had a stronger downregulation and a higher clinical response rate (mean 865-fold, n = 10, P = 0,01) than patients initially expressing low VEGF-levels (mean four-fold, n = 8). These results suggest that abnormal high VEGF expression is downregulated by SU5416 treatment, and furthermore that decreases in VEGF mRNA levels may provide an early marker of therapeutic response with anti-angiogenic therapy. Additionally, protein expression of STAT5 and AKT was assessed by western blotting in these patient samples, as well as in the leukemia cell line, M-07e, treated in vitro with SU5416 as a model system. In the AML patient samples, parallel downregulation of both STAT5 and AKT was observed in several cases (STAT5 in four of 15; AKT in three of six examined patients). These effects were confirmed with the cell line M-07e after incubation with SU5416 in vitro using concentrations that are achievable in patients. In summary, our data show suppression of the expression of VEGF and key signal transduction intermediates in AML blasts during treatment with SU5416.


Assuntos
Regulação Neoplásica da Expressão Gênica , Indóis/farmacologia , Proteínas Proto-Oncogênicas c-akt/biossíntese , Proteínas Proto-Oncogênicas c-akt/genética , Pirróis/farmacologia , Fator de Transcrição STAT5/biossíntese , Fator de Transcrição STAT5/genética , Fator A de Crescimento do Endotélio Vascular/biossíntese , Fator A de Crescimento do Endotélio Vascular/genética , Inibidores da Angiogênese/farmacologia , Linhagem Celular Tumoral , Separação Celular , Primers do DNA/química , Progressão da Doença , Citometria de Fluxo , Humanos , Inibidores de Proteínas Quinases/farmacologia , Transdução de Sinais , Resultado do Tratamento
4.
Tissue Eng Part C Methods ; 19(5): 363-74, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23098227

RESUMO

OBJECTIVE: The aim of tissue engineering is, for instance, to create a new valve or organ that is similar to the native one. This new construct may have the capability of growth, repair, and remodeling. One instance where tissue engineering offers an enormous advantage is in the treatment of Tetralogy of Fallot. After repair of this defect, pulmonary valve regurgitation with late ventricular dysfunction is not uncommonly observed. METHODS: In this study, we compared the use of endothelial cells (ECs) and smooth muscle cells (SMCs) derived from the carotid artery (group 1/n=5) with CD133+-cells derived from the bone-marrow (group 2/n=5) of juvenile sheep. Western blot analysis and histology were done before and after percutaneous pulmonary valved stent implantation. After seeding of the pulmonary valved stent with one of the cell groups, the construct was placed in a dynamic bioreactor for 16 days. After incubation, the valved stent was seeded again for 3 days. Finally, the valved stent was implanted percutaneously under angiographic control. RESULTS: In group 1, α-actin and calponin were found in the EC and SMC population by using Western blot analysis. In contrast, CD31 was found in EC, but not in the SMC population. Cells from group 2 demonstrated a pure population. CD133+-cells were detected in the CD133+-cell population and no CD133+-cells were found in the negative fraction. Three months after implantation, the transvalvular gradient was significantly higher in group 1 compared to group 2. CD31-staining demonstrated a confluent monolayer in both groups. Immunohistochemistry revealed strong expression of α-smooth-muscle-actin and an in-growth into the leaflets of both groups (p=ns). CD3-, CD20-, CD45-, and CD68-staining confirmed no signs of inflammation in group 2, whereas in group 1 small amounts of inflammation were detected in all analyzed animals. Von Kossa staining revealed mild to moderate calcifications in the annular region of group 1. In contrast, less calcification was detected in group 2. CONCLUSION: Autologous CD133+-cells derived from bone marrow had a better outcome with regard to calcification, inflammation, and transvalvular gradient compared to autologous cells derived from the carotid artery. Therefore, CD133+-cells are more advantageous for tissue engineering of heart valves.


Assuntos
Antígenos CD/metabolismo , Células da Medula Óssea/citologia , Artérias Carótidas/citologia , Glicoproteínas/metabolismo , Implante de Prótese de Valva Cardíaca , Peptídeos/metabolismo , Valva Pulmonar/fisiologia , Stents , Engenharia Tecidual/métodos , Antígeno AC133 , Angiografia , Animais , Western Blotting , Eletrocardiografia , Células Endoteliais/citologia , Células Endoteliais/metabolismo , Hemodinâmica , Imuno-Histoquímica , Miócitos de Músculo Liso/citologia , Miócitos de Músculo Liso/metabolismo , Mudanças Depois da Morte , Valva Pulmonar/diagnóstico por imagem , Ovinos , Coloração e Rotulagem , Sus scrofa , Ultrassonografia
5.
Cell Signal ; 24(3): 621-8, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21864674

RESUMO

The inositol 5-phosphatase SHIP1 is a negative regulator of signaling processes in hematopoietic cells. SHIP1 mediates its regulatory function after relocalization from the cytoplasm to the plasma membrane where it converts its substrate PI(3,4,5)P(3) to PI(3,4)P(2) thereby terminating PI3-kinase mediated signaling. In addition, SHIP1 converts Ins(1,3,4,5)P(4) to Ins(1,3,4)P(3) thereby regulating inositol phosphate metabolism. Here we report, that SHIP1 can be detected in nuclear puncta of Jurkat cells by confocal microscopy after expression of SHIP1 from a tetracycline inducible vector. SHIP1-containing nuclear puncta partially co-localize with FLASH, a multifunctional nuclear protein that has been linked to apoptotic signaling and transcriptional control. Nuclear localization was confirmed for endogenously expressed SHIP1 in the myeloid leukemia cell line TF1. In addition, enzymatically active SHIP1 was found in nuclear fractions of Jurkat cells with a similar specific activity as cytoplasmic SHIP1. Further analysis revealed that SHIP1 is a nucleocytoplasmic shuttling protein which is actively imported into and exported out of the nucleus. Nuclear import is mediated by two canonical nuclear localization signals (NLS) i.e. K(327)KSK and K(547)KLR. Mutational inactivation of each NLS motif inhibited nuclear import and reduced the proliferation of cells indicating a functional role of nuclear SHIP1 for cell growth. Our data indicate that SHIP1 is partly localized in the nucleus and suggest that SHIP1 plays a role for nuclear phosphoinositide and/or nuclear inositol phosphate signaling.


Assuntos
Núcleo Celular/enzimologia , Monoéster Fosfórico Hidrolases/metabolismo , Motivos de Aminoácidos , Proteínas Reguladoras de Apoptose/metabolismo , Proteínas de Ligação ao Cálcio/metabolismo , Linhagem Celular Tumoral , Proliferação de Células , Humanos , Inositol Polifosfato 5-Fosfatases , Mutagênese Sítio-Dirigida , Sinais de Localização Nuclear/metabolismo , Fosfatidilinositol-3,4,5-Trifosfato 5-Fosfatases , Monoéster Fosfórico Hidrolases/análise , Monoéster Fosfórico Hidrolases/genética , Proteínas Recombinantes de Fusão/análise , Proteínas Recombinantes de Fusão/genética , Proteínas Recombinantes de Fusão/metabolismo , Transdução de Sinais
6.
Eur J Cardiothorac Surg ; 41(3): 512-7, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22290931

RESUMO

OBJECTIVES: The present study investigates outcomes one month after implanting pigs with a novel mitral valved stent. METHODS: A novel nitinol stent custom designed for this study included a bovine pericardial valve. Six pigs received a valved stent into the mitral position by means of the transapical implantation technique. Afterwards, haemodynamic stability and valve function were assessed, immediately after implantation (n = 6), 4 weeks (n = 4) and 8 weeks (n = 1) thereafter using transoesophageal echocardiography (TEE), ventriculography and cardiac computed tomography (CT). Four of 6 surviving pigs were sacrificed at 4 weeks after implantation and one at 8 weeks thereafter. RESULTS: Optimal deployment and positioning were obtained in all but one animal. This animal died of unrecognized imperfect valved stent positioning after 4 days. The average mean gradient across the new valves and the left ventricular outflow tract (LVOT) were small. Mild regurgitation developed after valved stent deployment in one of six animals just after 1 h, and in none thereafter. All animals exhibited normal haemodynamics after mitral valved stent implantation, and stability was maintained throughout the monitoring period. Migration, embolization and paravalvular leakage were not evident in the remaining animals after 4 and 8 weeks. Gross evaluation revealed that 50-70% of the atrial element was covered by tissue growth at 4 weeks/8 weeks. CONCLUSIONS: This study demonstrates adequate deployment and anchorage of a unique, repositionable mitral valved stent. A good valve function was revealed in animals observed for 4 weeks and in one pig after 8 weeks.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Ligas , Animais , Ecocardiografia Transesofagiana , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica/fisiologia , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Desenho de Prótese , Stents , Sus scrofa , Tomografia Computadorizada por Raios X
7.
Eur J Cardiothorac Surg ; 40(2): 503-7, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21251845

RESUMO

OBJECTIVE: Trans-catheter aortic and pulmonary valve replacement procedures can result in favorable outcomes in selected patients. The aim of this study was to investigate the functioning of a novel self-expanding valved stent with super-absorbent polymer (SAP) for minimally invasive replacement of the tricuspid valve. METHODS: A newly designed nitinol stent with SAP was specially designed for the tricuspid annulus. This device was composed of right atrial anchoring elements, a left ventricular tubular stent, and a trileaflet bovine pericardial valve. The stent was coated with a waterproof material, and a pouch containing SAP for minimizing paravalvular leakage was placed beneath the atrial element. Seven pigs underwent minimally invasive off-pump tricuspid valved stent implantation. This was performed through a lower ministernotomy using a transventricular approach under transesophageal echocardiographic guidance. After 1 and 6h, a complete echocardiographic evaluation and hemodynamics (Swan-Ganz catheter) were performed. RESULTS: Six of seven pigs exhibited normal hemodynamics immediately after tricuspid valved stent implantation and maintained stability for the entire period of monitoring. In one pig, a part of the atrial stent elements was deployed into the right ventricle, leading to significant paravalvular leakage, and died very soon. All subsequent animals survived with good results in the observation period. Accurate positioning of the valved stent was documented in six of seven pigs. SAP expanded and filled the gap between the stent and the native annulus in all animals. Mild paravalvular leakage was found in two of the six animals. Nevertheless, the observed leakage decreased to trace levels 6h after implantation. In the additional four pigs, only trace tricuspid regurgitation was revealed. No right ventricular outflow tract obstruction was detected. CONCLUSIONS: Trans-apical off-pump tricuspid valved stent implantation is feasible in an acute experimental setting, and SAP may help to reduce paravalvular leakages.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Valva Tricúspide/cirurgia , Animais , Ecocardiografia Transesofagiana/métodos , Estudos de Viabilidade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Modelos Animais , Polímeros , Desenho de Prótese , Stents , Sus scrofa , Valva Tricúspide/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos
8.
J Thorac Cardiovasc Surg ; 139(3): 748-52, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19818967

RESUMO

OBJECTIVES: Transfemoral application of pulmonary heart valves has been studied for the past 10 years. Nevertheless, size restriction of percutaneous heart valved stents is still imminent. METHODS: In this study we implanted percutaneously a novel, low-profile polyurethane valved stent. Percutaneous implantation in pulmonary position was evaluated in 7 sheep. The new valved stent fits into a 14F delivery device. The self-expanding nitinol stent was produced by using a dip-coating technique, and a modified commercially available endovascular stent graft system served as a delivery device. The valved stents were deployed directly over the native pulmonary valve under fluoroscopic control. Transthoracic echocardiography was performed after 4 weeks. At the time of explantation, the animals were reanalyzed and killed. Angiography was performed at implantation and at the end of the study. Explanted constructs were analyzed macroscopically and microscopically. RESULTS: Angiography and echocardiography in all animals demonstrated orthotopic position of the stents at the time of implantation and after 4 weeks. During the deployment procedure, rhythm disturbances occurred in all animals. The peak-to-peak transvalvular gradient was 2.3 +/- 1.2 mm Hg initially and 4.1 +/- 2.4 mm Hg at follow-up. One-month follow-up confirmed competent neovalves without any paravalvular leakage. Gross morphology demonstrated good opening and closure characteristics. No calcification was seen macroscopically, and surrounding tissue was free of calcification. CONCLUSION: In the present study we demonstrated successful merging of 2 novel technologies for percutaneous treatment of pulmonary valve diseases using polyurethane stent valve constructs.


Assuntos
Implantação de Prótese/métodos , Valva Pulmonar/cirurgia , Stents , Animais , Artéria Femoral , Poliuretanos , Desenho de Prótese , Ovinos
9.
Ann Thorac Surg ; 89(1): 259-63, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20103248

RESUMO

PURPOSE: The purpose of this study was to evaluate the feasibility of percutaneously implanted tissue-engineered valved stents in the ovine pulmonary valve position. DESCRIPTION: Porcine pulmonary heart valves and small intestinal submucosa were obtained from a slaughterhouse, and the intestinal submucosa used to cover the inside of the porcine pulmonary valved stents. Endothelial cells and autologous myofibroblasts were obtained from carotid artery segments of juvenile sheep. After myofibroblast seeding, constructs were placed in a dynamic bioreactor system and were cultured for 16 days. After Endothelial cell seeding, the tissue-engineered valved stents were deployed into the pulmonary valve annular site. Angiography was performed at implantation and explantation (4 weeks). Constructs were analyzed macroscopically and microscopically. EVALUATION: Orthotopic positioning of the stents (n = 3) at the time of implantation and explantation, as well as normal valve function, was observed through angiography. Gross morphology confirmed excellent opening and closing of all leaflets. Strong expression of alpha-smooth muscle actin in neointerstitial cells and of von-Willebrand-Factor in endothelial cells was revealed by immunocytochemistry. CONCLUSIONS: This study demonstrates successful merging of two novel technologies: (1) percutaneous valved stent implantation and (2) tissue engineering of autologous heart valves.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Valva Pulmonar/cirurgia , Engenharia Tecidual/métodos , Animais , Artérias Carótidas/citologia , Células Cultivadas , Endotélio Vascular/citologia , Endotélio Vascular/transplante , Ovinos , Transplante Autólogo
10.
Cardiovasc Res ; 88(3): 453-61, 2010 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-20595320

RESUMO

AIMS: Percutaneous implantation has already been used clinically and is a great option for treating young patients. The use of autologous tissue-engineered valved stents might solve the problem of degeneration and limited durability of biological heart valves. METHODS AND RESULTS: Porcine pulmonary heart valves and small intestinal submucosa were obtained from a slaughterhouse. The intestinal submucosa was used to cover the inside of the porcine pulmonary valved stents. Endothelial cells (ECs) and autologous myofibroblasts (MFs) were used from carotid artery segments of juvenile sheep. After MF seeding, constructs were placed in a dynamic bioreactor system and cultured for 16 days. After additional EC seeding, tissue-engineered valved stents were percutaneously deployed into the annulus of the pulmonary valve (n = 9). Angiography was performed at implantation and 4-week follow-up. Constructs were analysed radiographically, by post-mortem examination, and microscopically. In all but one case, orthotopic positioning of the stents (n = 6) at the time of implantation and explantation was observed angiographically, macroscopically, and by computer tomography scan and demonstrated normal valve function (n = 7). Gross morphology confirmed excellent opening and closure characteristics of all leaflets after 4 weeks (n = 7). Strong expression of α-smooth muscle actin in neo-interstitial cells and of von Willebrand factor and PECAM-1 in ECs was revealed by immunocytochemistry. CONCLUSION: Good functioning and morphological characteristics were observed after percutaneous tissue-engineered valved stent implantation with autologous cells. This implantation of autologous tissue-engineered valved stents will become a valid future option in adolescents.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Valva Pulmonar/cirurgia , Stents , Engenharia Tecidual , Ligas , Angiografia , Animais , Células Cultivadas , Ecocardiografia , Implante de Prótese de Valva Cardíaca/instrumentação , Mucosa Intestinal/citologia , Modelos Animais , Miofibroblastos/citologia , Valva Pulmonar/diagnóstico por imagem , Ovinos , Suínos , Transplante Heterólogo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA