Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 102(10): 101802, 2009 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-19392103

RESUMO

The MiniBooNE Collaboration observes unexplained electronlike events in the reconstructed neutrino energy range from 200 to 475 MeV. With 6.46x10;{20} protons on target, 544 electronlike events are observed in this energy range, compared to an expectation of 415.2+/-43.4 events, corresponding to an excess of 128.8+/-20.4+/-38.3 events. The shape of the excess in several kinematic variables is consistent with being due to either nu_{e} and nu[over ]_{e} charged-current scattering or nu_{mu} neutral-current scattering with a photon in the final state. No significant excess of events is observed in the reconstructed neutrino energy range from 475 to 1250 MeV, where 408 events are observed compared to an expectation of 385.9+/-35.7 events.

2.
Phys Rev Lett ; 102(21): 211801, 2009 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-19519094

RESUMO

We report the first observation of off-axis neutrino interactions in the MiniBooNE detector from the NuMI beam line at Fermilab. The MiniBooNE detector is located 745 m from the NuMI production target, at 110 mrad angle (6.3 degrees) with respect to the NuMI beam axis. Samples of charged-current quasielastic numicro and nue interactions are analyzed and found to be in agreement with expectation. This provides a direct verification of the expected pion and kaon contributions to the neutrino flux and validates the modeling of the NuMI off-axis beam.

3.
Phys Rev Lett ; 103(6): 061802, 2009 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-19792551

RESUMO

The MiniBooNE Collaboration reports a search for nu_{micro} and nu[over]_{micro} disappearance in the Deltam;{2} region of 0.5-40 eV;{2}. These measurements are important for constraining models with extra types of neutrinos, extra dimensions, and CPT violation. Fits to the shape of the nu_{micro} and nu[over]_{micro} energy spectra reveal no evidence for disappearance at the 90% confidence level (C.L.) in either mode. The test of nu[over]_{micro} disappearance probes a region below Deltam;{2} = 40 eV;{2} never explored before.

4.
Phys Rev Lett ; 103(8): 081801, 2009 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-19792715

RESUMO

Using high statistics samples of charged-current numu interactions, the MiniBooNE [corrected] Collaboration reports a measurement of the single-charged-pion production to quasielastic cross section ratio on mineral oil (CH2), both with and without corrections for hadron reinteractions in the target nucleus. The result is provided as a function of neutrino energy in the range 0.4 GeV

5.
Phys Rev Lett ; 100(3): 032301, 2008 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-18232974

RESUMO

The observation of neutrino oscillations is clear evidence for physics beyond the standard model. To make precise measurements of this phenomenon, neutrino oscillation experiments, including MiniBooNE, require an accurate description of neutrino charged current quasielastic (CCQE) cross sections to predict signal samples. Using a high-statistics sample of nu_(mu) CCQE events, MiniBooNE finds that a simple Fermi gas model, with appropriate adjustments, accurately characterizes the CCQE events observed in a carbon-based detector. The extracted parameters include an effective axial mass, M_(A)(eff)=1.23+/-0.20 GeV, that describes the four-momentum dependence of the axial-vector form factor of the nucleon, and a Pauli-suppression parameter, kappa=1.019+/-0.011. Such a modified Fermi gas model may also be used by future accelerator-based experiments measuring neutrino oscillations on nuclear targets.

6.
Phys Rev Lett ; 98(23): 231801, 2007 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-17677898

RESUMO

The MiniBooNE Collaboration reports first results of a search for nu e appearance in a nu mu beam. With two largely independent analyses, we observe no significant excess of events above the background for reconstructed neutrino energies above 475 MeV. The data are consistent with no oscillations within a two-neutrino appearance-only oscillation model.

7.
N Engl J Med ; 339(12): 792-8, 1998 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-9738086

RESUMO

BACKGROUND AND METHODS: Although generalized convulsive status epilepticus is a life-threatening emergency, the best initial drug treatment is uncertain. We conducted a five-year randomized, double-blind, multicenter trial of four intravenous regimens: diazepam (0.15 mg per kilogram of body weight) followed by phenytoin (18 mg per kilogram), lorazepam (0.1 mg per kilogram), phenobarbital (15 mg per kilogram), and phenytoin (18 mg per kilogram). Patients were classified as having either overt generalized status epilepticus (defined as easily visible generalized convulsions) or subtle status epilepticus (indicated by coma and ictal discharges on the electroencephalogram, with or without subtle convulsive movements such as rhythmic muscle twitches or tonic eye deviation). Treatment was considered successful when all motor and electroencephalographic seizure activity ceased within 20 minutes after the beginning of the drug infusion and there was no return of seizure activity during the next 40 minutes. Analyses were performed with data on only the 518 patients with verified generalized convulsive status epilepticus as well as with data on all 570 patients who were enrolled. RESULTS: Three hundred eighty-four patients had a verified diagnosis of overt generalized convulsive status epilepticus. In this group, lorazepam was successful in 64.9 percent of those assigned to receive it, phenobarbital in 58.2 percent, diazepam plus phenytoin in 55.8 percent, and phenytoin in 43.6 percent (P=0.02 for the overall comparison among the four groups). Lorazepam was significantly superior to phenytoin in a pairwise comparison (P=0.002). Among the 134 patients with a verified diagnosis of subtle generalized convulsive status epilepticus, no significant differences among the treatments were detected (range of success rates, 7.7 to 24.2 percent). In an intention-to-treat analysis, the differences among treatment groups were not significant, either among the patients with overt status epilepticus (P=0.12) or among those with subtle status epilepticus (P=0.91). There were no differences among the treatments with respect to recurrence during the 12-hour study period, the incidence of adverse reactions, or the outcome at 30 days. CONCLUSIONS: As initial intravenous treatment for overt generalized convulsive status epilepticus, lorazepam is more effective than phenytoin. Although lorazepam is no more efficacious than phenobarbital or diazepam plus phenytoin, it is easier to use.


Assuntos
Anticonvulsivantes/uso terapêutico , Estado Epiléptico/tratamento farmacológico , Idoso , Anticonvulsivantes/efeitos adversos , Diazepam/efeitos adversos , Diazepam/uso terapêutico , Método Duplo-Cego , Quimioterapia Combinada , Feminino , Humanos , Injeções Intravenosas , Lorazepam/efeitos adversos , Lorazepam/uso terapêutico , Masculino , Pessoa de Meia-Idade , Fenobarbital/efeitos adversos , Fenobarbital/uso terapêutico , Fenitoína/efeitos adversos , Fenitoína/uso terapêutico , Resultado do Tratamento
8.
Phys Rev Lett ; 88(4): 041803, 2002 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-11801107

RESUMO

Additional evidence for the rare kaon decay K+-->pi+nu(nu) has been found in a new data set with comparable sensitivity to the previously reported result. One new event was observed in the pion momentum region examined, 211pi+nu(nu)) = 1.57(+1.75)(-0.82)x10(-10).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA