Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Biotechnol Bioeng ; 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38877726

RESUMO

Despite various clinical options, human anterior cruciate ligament (ACL) lesions do not fully heal. Biomaterial-guided gene therapy using recombinant adeno-associated virus (rAAV) vectors may improve the intrinsic mechanisms of ACL repair. Here, we examined whether poly(sodium styrene sulfonate)-grafted poly(ε-caprolactone) (pNaSS-grafted PCL) films can deliver rAAV vectors coding for the reparative basic fibroblast growth factor (FGF-2) and transforming growth factor beta (TGF-ß) in human mesenchymal stromal cells (hMSCs) as a source of implantable cells in ACL lesions. Efficient and sustained rAAV-mediated reporter (red fluorescent protein) and therapeutic (FGF-2 and TGF-ß) gene overexpression was achieved in the cells for at least 21 days in particular with pNaSS-grafted PCL films relative to all other conditions (up to 5.2-fold difference). Expression of FGF-2 and TGF-ß mediated by rAAV using PCL films increased the levels of cell proliferation, the DNA contents, and the deposition of proteoglycans and of type-I and -III collagen (up to 2.9-fold difference) over time in the cells with higher levels of transcription factor expression (Mohawk, Scleraxis) (up to 1.9-fold difference), without activation of inflammatory tumor necrosis alpha especially when using pNaSS-grafted PCL films compared with the controls. Overall, the effects mediated by TGF-ß were higher than those promoted by FGF-2, possibly due to higher levels of gene expression achieved upon rAAV gene transfer. This study shows the potential of using functionalized PCL films to apply rAAV vectors for ACL repair.

2.
Int J Mol Sci ; 24(13)2023 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-37446318

RESUMO

Lesions in the human anterior cruciate ligament (ACL) are frequent, unsolved clinical issues due to the limited self-healing ability of the ACL and lack of treatments supporting full, durable ACL repair. Gene therapy guided through the use of biomaterials may steadily activate the processes of repair in sites of ACL injury. The goal of the present study was to test the hypothesis that functionalized poly(sodium styrene sulfonate)-grafted poly(ε-caprolactone) (pNaSS-grafted PCL) films can effectively deliver recombinant adeno-associated virus (rAAV) vectors as a means of overexpressing two reparative factors (transforming growth factor beta-TGF-ß and basic fibroblast growth factor-FGF-2) in primary human ACL fibroblasts. Effective, durable rAAV reporter red fluorescent protein and candidate TGF-ß and FGF-2 gene overexpression was achieved in the cells for at least 21 days, especially when pNaSS-grafted PCL films were used versus control conditions, such as ungrafted films and systems lacking vectors or films (between 1.8- and 5.2-fold differences), showing interactive regulation of growth factor production. The expression of TGF-ß and FGF-2 from rAAV via PCL films safely enhanced extracellular matrix depositions of type-I/-III collagen, proteoglycans/decorin, and tenascin-C (between 1.4- and 4.5-fold differences) in the cells over time with increased levels of expression of the specific transcription factors Mohawk and scleraxis (between 1.7- and 3.7-fold differences) and without the activation of the inflammatory mediators IL-1ß and TNF-α, most particularly with pNaSS-grafted PCL films relative to the controls. This work shows the value of combining rAAV gene therapy with functionalized PCL films to enhance ACL repair.


Assuntos
Dependovirus , Fator de Crescimento Transformador beta , Humanos , Fator de Crescimento Transformador beta/genética , Fator de Crescimento Transformador beta/metabolismo , Dependovirus/genética , Dependovirus/metabolismo , Ligamento Cruzado Anterior , Fator 2 de Crescimento de Fibroblastos/genética , Fator 2 de Crescimento de Fibroblastos/metabolismo , Fibroblastos/metabolismo
3.
Nanotechnology ; 33(20)2022 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-35105825

RESUMO

Polyethylene terephthalate (PET) is widely used to elaborate biomaterials and medical devices in particular for long-term implant applications but tuning their surface properties remains challenging. We investigate surface functionalization by grafting poly(sodium 4-styrene sulfonate, PNaSS) with the aim of enhancing protein adhesion and cellular activity. Elucidating the topography and molecular level organization of the modified surfaces is important for understanding and predicting biological activity. In this work, we explore several grafting methods including thermal grafting, thermal grafting in the presence of Mohr's salt, and UV activation. We characterize the different surfaces obtained using atomic force microscopy (AFM), contact angle (CA), and x-ray photoelectron spectroscopy (XPS). We observe an increase in the percentage of sulfur atoms (XPS) that correlates with changes in (CA), and we identify by AFM characteristic features, which we interpret as patches of polymers on the PET surfaces. This work demonstrates tuning of biomaterials surface by functionalization and illustrates the capability of AFM to provide insights into the spatial organization of the grafted polymer.


Assuntos
Microscopia de Força Atômica , Polietilenotereftalatos/química , Polímeros/química , Ácidos Sulfônicos/química , Materiais Biocompatíveis/química , Espectroscopia Fotoeletrônica , Polimerização , Propriedades de Superfície
4.
Int J Mol Sci ; 23(22)2022 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-36430947

RESUMO

The anterior cruciate ligament (ACL), the principal ligament for stabilization of the knee, is highly predisposed to injury in the human population. As a result of its poor intrinsic healing capacities, surgical intervention is generally necessary to repair ACL lesions, yet the outcomes are never fully satisfactory in terms of long-lasting, complete, and safe repair. Gene therapy, based on the transfer of therapeutic genetic sequences via a gene vector, is a potent tool to durably and adeptly enhance the processes of ACL repair and has been reported for its workability in various experimental models relevant to ACL injuries in vitro, in situ, and in vivo. As critical hurdles to the effective and safe translation of gene therapy for clinical applications still remain, including physiological barriers and host immune responses, biomaterial-guided gene therapy inspired by drug delivery systems has been further developed to protect and improve the classical procedures of gene transfer in the future treatment of ACL injuries in patients, as critically presented here.


Assuntos
Lesões do Ligamento Cruzado Anterior , Humanos , Lesões do Ligamento Cruzado Anterior/genética , Lesões do Ligamento Cruzado Anterior/terapia , Ligamento Cruzado Anterior/cirurgia , Articulação do Joelho
5.
J Mater Sci Mater Med ; 26(11): 261, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26449451

RESUMO

The research developed on functionalized model or prosthetic surfaces with bioactive polymers has raised the possibility to modulate and/or control the biological in vitro and in vivo responses to synthetic biomaterials. The mechanisms underlying the bioactivity exhibited by sulfonated groups on surfaces involves both selective adsorption and conformational changes of adsorbed proteins. Indeed, surfaces functionalized by grafting poly(sodium styrene sulfonate) [poly(NaSS)] modulate the cellular and bacterial response by inducing specific interactions with fibronectin (Fn). Once implanted, a biomaterial surface is exposed to a milieu of many proteins that compete for the surface which dictates the subsequent biological response. Once understood, this can be controlled by dictating exposure of active binding sites. In this in vitro study, we report the influence of binary mixtures of proteins [albumin (BSA), Fn and collagen type I (Col I)] adsorbed on poly(NaSS) grafted Ti6Al4V on the adhesion and differentiation of MC3T3-E1 osteoblast-like cells and the adhesion and proliferation of Staphylococcus aureus (S. aureus). Outcomes showed that poly(NaSS) stimulated cell spreading, attachment strength, differentiation and mineralization, whatever the nature of protein provided at the interface compared with ungrafted Ti6Al4V (control). While in competition, Fn and Col I were capable of prevailing over BSA. Fn played an important role in the early interactions of the cells with the surface, while Col I was responsible for increased alkaline phosphatase, calcium and phosphate productions associated with differentiation. Poly(NaSS) grafted surfaces decreased the adhesion of S. aureus and the presence of Fn on these chemically altered surfaces increased bacterial resistance ≈70% compared to the ungrafted Ti6Al4V. Overall, our study showed that poly(NaSS) grafted Ti6Al4V selectively adsorbed proteins (particularly Fn) promoting the adhesion and differentiation of osteoblast-like cells while reducing bacterial adhesion to create a bioactive surface with potential for orthopaedic applications.


Assuntos
Proteínas de Bactérias/química , Polímeros/química , Staphylococcus aureus/fisiologia , Titânio/química , Células 3T3 , Animais , Aderência Bacteriana , Diferenciação Celular , Proliferação de Células , Camundongos , Ligação Proteica , Espectroscopia de Infravermelho com Transformada de Fourier , Propriedades de Superfície
6.
J Mater Sci Mater Med ; 26(7): 206, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26155977

RESUMO

Poly(sodium styrene sulfonate) (pNaSS) was grafted onto poly(ε-caprolatone) (PCL) surfaces via ozonation and graft polymerization. The effect of ozonation and polymerization time, as well as the Mohr's salt concentration in the grafting solution, on the degree of grafting was investigated. The degree of grafting was determined through toluidine blue staining. The surface chemical change was characterized by attenuated total reflection Fourier transform infrared spectroscopy, energy-dispersive X-ray spectroscopy and X-ray photoelectron spectroscopy. The result demonstrated that the grafting did not induce any degradation of PCL, and that pNaSS was grafted onto PCL as a thin and covalently stable layer. Furthermore, the modified PCL surface reveals a significant increase in the metabolic activity of fibroblastic cells, as well as a better cell spreading with higher adhesion strength. Consequently, bioactivity of PCL is greatly enhanced by immobilizing a thin layer of pNaSS onto its surface. The grafting of pNaSS is a promising approach to increase the bioactivity of PCL-based materials used in tissue engineering applications, such as ligament reconstruction.


Assuntos
Poliésteres/química , Polímeros/química , Ácidos Sulfônicos/química , Fibroblastos/citologia , Espectroscopia Fotoeletrônica , Espectrometria por Raios X , Espectroscopia de Infravermelho com Transformada de Fourier , Propriedades de Superfície , Engenharia Tecidual
7.
Langmuir ; 30(31): 9477-83, 2014 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-25054428

RESUMO

Functionalization of surfaces with poly(sodium styrenesulfonate) (poly(NaSS)) has recently been found to enhance osteointegration of implantable materials. Radical polymerization of poly(NaSS) on titanium (Ti)-based substrates has been used to improve their long-term performance by preventing fibrosis and consequently implant loosening. However, the influence of the sulfonate groups on the early cell behavior and the associated molecular phenomena remains to be understood. In this work, we used quartz crystal microbalance with dissipation (QCM-D) to elucidate the role of poly(NaSS) in enhancing osteoblastic cell attachment. This was measured by following the cell attachment using the MC3T3-E1 cell line, on fetal bovine serum (FBS) preadsorbed surfaces and on substrates adsorbed with a series of relevant proteins, bovine serum albumin (BSA), fibronectin (Fn), and collagen type I (Col I). Comparison of the performance of poly(NaSS) with other clinically important substrates such as Ti alloy Ti6Al4V, gold, and poly(desamino-tyrosyl-tyrosine ethyl ester carbonate) (poly(DTEc)) indicates poly(NaSS) to be a superior substrate for MC3T3-E1 cells attachment. This attachment was found to be integrin mediated in the presence of Fn and Col I. Antibodies specific to the RGD peptide and the N- and C-terminal HB-binding domains reacted more intensively with Fn adsorbed on poly(NaSS). Fn adapts a conformation favorable to RGD mediated cell attachment when adsorbed onto poly(NaSS).


Assuntos
Colágeno Tipo I/química , Fibronectinas/química , Osteoblastos/citologia , Poliestirenos/química , Células 3T3 , Alumínio/química , Animais , Biopolímeros/química , Ouro/química , Camundongos , Conformação Molecular , Tamanho da Partícula , Técnicas de Microbalança de Cristal de Quartzo , Soroalbumina Bovina/química , Propriedades de Superfície , Titânio/química , Tirosina/análogos & derivados , Tirosina/química , Vanádio/química
8.
Arthroscopy ; 29(6): 1079-88, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23726110

RESUMO

PURPOSE: The purposes of this study were to assess tissue ingrowth within the Ligament Advanced Reinforcement System (LARS) artificial ligament (LARS AC; LARS, Arc sur Tille, France) and to study the biomechanical characteristics of the reconstructed knees in a sheep model of anterior cruciate ligament (ACL) replacement. METHODS: Twenty-five female sheep underwent excision of the proximal third of the left ACL and intra-articular joint stabilization with a 44-strand polyethylene terephthalate ligament (mean ultimate tensile failure load, 2,500 N). Animals were killed either 3 or 12 months after surgery. Explanted knees were processed for histology (n = 10) or mechanical tests including tests of laxity and loading to failure in tension (n = 15). RESULTS: Well-vascularized tissue ingrowth within the artificial ligament was only observed in the portions of the ligament in contact with the host's tissues (native ligament and bone tunnels). Ligament wear was observed in 40% of explanted knees. The ultimate tensile failure loads of the operated knees at both time points were inferior to those of the contralateral, intact knees (144 ± 69 N at 3 months and 260 ± 126 N at 12 months versus 1,241 ± 270 N and 1,218 ± 189 N, respectively) (P < .01). In specimens with intact artificial ligaments, failure occurred by slippage from the bone tunnels in all specimens explanted 3 months postoperatively and in half of the specimens explanted 12 months postoperatively. CONCLUSIONS: This study provides evidence that the LARS AC has a satisfactory biointegration but that it is not suitable for ACL replacement if uniform tissue ingrowth is contemplated. Despite good clinical performance up to 1 year after implantation, none of the reconstructions approached the mechanical performance of the normal ACL in the ovine model. Partial tearing of the artificial ligament, which led to a significant decrease in ultimate tensile strength, was observed in 40% of cases in the ovine model. CLINICAL RELEVANCE: The LARS is not a suitable scaffold for ACL replacement. Further animal studies are needed to evaluate its potential for augmentation of ligament repair.


Assuntos
Ligamento Cruzado Anterior/cirurgia , Órgãos Artificiais , Instabilidade Articular/cirurgia , Falha de Prótese/etiologia , Alicerces Teciduais , Animais , Ligamento Cruzado Anterior/irrigação sanguínea , Ligamento Cruzado Anterior/fisiopatologia , Fenômenos Biomecânicos/fisiologia , Feminino , França , Instabilidade Articular/etiologia , Ruptura/cirurgia , Carneiro Doméstico , Resistência à Tração
10.
J Orthop Surg Res ; 17(1): 7, 2022 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-34986843

RESUMO

BACKGROUND: Anterior cruciate ligament (ACL) repair techniques are new emerging strategies prevailing, in selected cases, over standard reconstruction of the ACL with excision of its remnants. Mid-substance ACL tears represent a challenge for ACL repair techniques, and remnants-preserving ACL reconstruction (rp-ACLR) using an autograft remains the recommended treatment in this situation. However, morbidity associated with the autograft harvesting prompts the need for alternative surgical strategies based on the use of synthetic scaffolds. Relevant small animal models of mid-substance tears with ACL remnants preservation and reconstruction are necessary to establish the preliminary proof of concept of these new strategies. METHODS: A rat model of rp-ACLR using a tendinous autograft after complete mid-substance ACL transection was established. Twelve weeks following surgery, clinical outcomes and knee joints were assessed through visual gait analysis, Lachman tests, thigh perimeter measurements, magnetic resonance imaging, micro-computed tomography, and histology, to evaluate the morbidity of the procedure, accuracy of bone tunnel positioning, ACL remnants fate, osteoarthritis, and autograft bony integration. Results were compared with those obtained with isolated ACL transection without reconstruction and to right non-operated knees. RESULTS AND DISCUSSION: Most operated animals were weight-bearing the day following surgery, and no adverse inflammatory reaction has been observed for the whole duration of the study. Autograft fixation with cortical screws provided effective graft anchorage until sacrifice. Healing of the transected ACL was not observed in the animals in which no graft reconstruction was performed. rp-ACLR was associated with a reduced degeneration of the ACL remnants (p = 0.004) and cartilages (p = 0.0437). Joint effusion and synovitis were significantly lower in the reconstructed group compared to the transected ACL group (p = 0.004). Most of the bone tunnel apertures were anatomically positioned in the coronal and/or sagittal plane. The most deviated bone tunnel apertures were the tibial ones, located in median less than 1 mm posteriorly to anatomical ACL footprint center. CONCLUSION: This study presents a cost-effective, new relevant and objective rat model associated with low morbidity for the preliminary study of bio-implantable materials designed for remnants-preserving ACL surgery after mid-substance ACL tear.


Assuntos
Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/cirurgia , Animais , Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Autoenxertos , Articulação do Joelho/cirurgia , Imageamento por Ressonância Magnética , Modelos Animais , Ratos , Tíbia/cirurgia , Transplante Autólogo , Microtomografia por Raio-X
11.
Biotechnol Bioeng ; 108(4): 947-62, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21404267

RESUMO

Sauerbrey [(1956), Z Phys 55:206-222] showed that the shift in resonance frequency of thickness shear mode (TSM) of a quartz crystal sensor is proportional to the mass, which is deposited on it. However, new powerful electrical circuits were developed that are capable of operating TSM quartz crystal sensors in fluids which enabled this method to be introduced into electrochemical and biological applications. These applications include the detection of virus capsids, bacteria, mammalian cells, the interaction of DNA and RNA with complementary strands, specific recognition of protein ligands by immobilized receptors, and last but not least the study of complete immunosensors. Piezoelectric quartz transducers allow a label-free identification of molecules; they are more than mass sensors since the biosensor response is also influenced by the surface charge of adsorbed proteins, interfacial phenomena, surface roughness and viscoelastic properties of the adhered biomaterial. These new characteristics have recently been used to investigate cell, liposome, and protein adhesion onto surfaces, thus permitting the rapid determination of morphological cell changes as a response to pharmacological substances, and changes in the water content of biopolymers avoiding of time-consuming methods. We validated an alternative quantitative acoustical engineering for cell adhesion process monitored by the TSM. Shear acoustical results (motional resistance) are further correlated to cell counting procedures and are sensitive of adhesion processes in real-time.


Assuntos
Técnicas Biossensoriais/métodos , Adesão Celular , Acústica , Animais , Células CHO , Contagem de Células/métodos , Cricetinae , Cricetulus , Quartzo , Reprodutibilidade dos Testes , Transdutores
12.
Langmuir ; 27(21): 13104-12, 2011 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-21892821

RESUMO

Biointegration of titanium implants in the body is controlled by their surface properties. Improving surface properties by coating with a bioactive polymer is a promising approach to improve the biological performance of titanium implants. To optimize the grafting processes, it is important to fully understand the composition and structure of the modified surfaces. The main focus of this study is to provide a detailed, multitechnique characterization of a bioactive poly(sodium styrene sulfonate) (pNaSS) thin film grafted from titanium surfaces via a two-step procedure. Thin titanium films (∼50 nm thick with an average surface roughness of 0.9 ± 0.2 nm) prepared by evaporation onto silicon wafers were used as smooth model substrates. X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS) showed that the titanium film was covered with a TiO(2) layer that was at least 10 nm thick and contained hydroxyl groups present at the outermost surface. These hydroxyl groups were first modified with a 3-methacryloxypropyltrimethoxysilane (MPS) cross-linker. XPS and ToF-SIMS showed that a monolayer of the MPS molecules was successfully attached onto the titanium surfaces. The pNaSS film was grafted from the MPS-modified titanium through atom transfer radical polymerization. Again, XPS and ToF-SIMS were used to verify that the pNaSS molecules were successfully grafted onto the modified surfaces. Atomic force microscopy analysis showed that the film was smooth and uniformly covered the surface. Fourier transform infrared spectroscopy indicated that an ordered array of grafted NaSS molecules were present on the titanium surfaces. Sum frequency generation vibration spectroscopy and near edge X-ray absorption fine structure spectroscopy illustrated that the NaSS molecules were grafted onto the titanium surface with a substantial degree of orientational order in the styrene rings.


Assuntos
Polímeros/química , Ácidos Sulfônicos/química , Titânio/química , Metacrilatos/química , Silanos/química , Propriedades de Superfície
13.
Biointerphases ; 16(5): 051003, 2021 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-34634913

RESUMO

Cell adhesion and growth over prostheses are strongly influenced by the adsorption and conformation of adhesive proteins from blood and extracellular matrix, such as fibronectin. This key behavior can be possibly exploited to develop a prosthetic ligament based on the surface bioactivation of biodegradable materials. In this work, surface functionalization was performed by grafting poly(sodium 4-styrene sulfonate) on polyethylene terephthalate and polycaprolactone using a thermal surface-initiated atom transfer radical polymerization grafting technique. The morphology and mechanical properties of the adsorbed fibronectin in the presence of albumin were studied by atomic force microscopy. The morphology of fibronectin on two kinds of polyester surfaces was similar. However, the study results showed a remarkable conformation change of fibronectin when adsorbed onto the nongrafted or grafted surface, leading to an increase in cell adhesion and organization in the second case. This research provided evidence of the relationship between the morphology change of fibronectin to the enhancement of the cell adhesion and spreading on the grafted surface of polyester.


Assuntos
Fibronectinas , Poliésteres , Adsorção , Adesão Celular , Microscopia de Força Atômica , Poliestirenos , Propriedades de Superfície
14.
Acta Biomater ; 121: 68-88, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33212233

RESUMO

Silicone implants are widely used in the medical field for plastic or reconstructive surgeries for the purpose of soft tissue issues. However, as with any implanted object, healthcare-associated infections are not completely avoidable. The material suffers from a lack of biocompatibility and is often subject to bacterial/microbial infections characterized by biofilm growth. Numerous strategies have been developed to either prevent, reduce, or fight bacterial adhesion by providing an antibacterial property. The present review summarizes the diverse approaches to deal with bacterial infections on silicone surfaces along with the different methods to activate/oxidize the surface before any surface modifications. It includes antibacterial coatings with antibiotics or nanoparticles, covalent attachment of active bacterial molecules like peptides or polymers. Regarding silicone surfaces, the activation step is essential to render the surface reactive for any further modifications using energy sources (plasma, UV, ozone) or chemicals (acid solutions, sol-gel strategies, chemical vapor deposition). Meanwhile, corresponding work on breast silicone prosthesis is discussed. The latter is currently in the line of sight for causing severe capsular contractures. Specifically, to that end, besides chemical modifications, the antibacterial effect can also be achieved by physical surface modifications by adjusting the surface roughness and topography for instance.


Assuntos
Anti-Infecciosos , Implantes de Mama , Antibacterianos/farmacologia , Biofilmes , Materiais Revestidos Biocompatíveis/farmacologia , Silicones , Propriedades de Superfície
15.
Sci Rep ; 11(1): 4258, 2021 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-33608601

RESUMO

Polyethylene terephthalate (PET) fibers and fabrics are widely used for medical device applications such as vascular and anterior cruciate ligament prostheses. Several years ago, we began functionalizing PET fabrics using anionic polymers to enhance their biocompatibility, cell adhesion, proliferation and functional performance as PET ligament prostheses. Polymer functionalization followed a grafting-from process from virgin PET surfaces subject to spin-finish oil additive removal under Soxhlet extraction to remove residual fiber manufacturing oil. Nevertheless, with increasing time from manufacture, PET fabrics stored without a spin finish removal step exhibited degradation of spin finish oil, leading to (1) incomplete surface cleaning, and (2) PET surface degradation. Moreover, oxidizing agents present in the residual degraded oil prevented reliable functionalization of the prosthesis fibers in these PET fabrics. This study compares effects of PET fabric/spin finish oil storage on PET fabric anionic polymer functionalization across two PET fabric ligament storage groups: (1) 2- and 10- year old ligaments, and (2) 26-year old ligaments. Strong interactions between degraded spin finish oil and PET fiber surfaces after long storage times were demonstrated via extraction yield; oil chemistry changed assessed by spectral analysis. Polymer grafting/functionalization efficiency on stored PET fabrics was correlated using atomic force microscopy, including fiber surface roughness and relationships between grafting degree and surface Young's modulus. New PET fabric Young's modulus significantly decreased by anionic polymer functionalization (to 96%, grafting degree 1.6 µmol/g) and to reduced modulus and efficiency (29%) for 10 years storage fabric (grafting degree ~ 1 µmol/g). As fiber spin finish is mandatory in biomedically applicable fiber fabrication, assessing effects of spin finish oil on commercial polymer fabrics after longer storage under various conditions (UV light, temperature) is necessary to understand possible impacts on fiber degradation and surface functionalization.

16.
Biomedicines ; 9(7)2021 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-34356888

RESUMO

A challenge in contractile restoration of myocardial scars is one of the principal aims in cardiovascular surgery. Recently, a new potent biological tool used within healing processes is represented by exosomes derived from mesenchymal stem cells (MSCs). These cells are the well-known extracellular nanovesicles released from cells to facilitate cell function and communication. In this work, a combination of elastomeric membranes and exosomes was obtained and tested as a bioimplant. Mesenchymal stem cells (MSCs) and macrophages were seeded into the scaffold (polycaprolactone) and filled with exosomes derived from MSCs. Cells were tested for proliferation with an MTT test, and for wound healing properties and macrophage polarization by gene expression. Moreover, morphological analyses of their ability to colonize the scaffolds surfaces have been further evaluated. Results confirm that exosomes were easily entrapped onto the surface of the elastomeric scaffolds, increasing the wound healing properties and collagen type I and vitronectin of the MSC, and improving the M2 phenotype of the macrophages, mainly thanks to the increase in miRNA124 and decrease in miRNA 125. We can conclude that the enrichment of elastomeric scaffolds functionalized with exosomes is as an effective strategy to improve myocardial regeneration.

17.
Hum Gene Ther ; 32(17-18): 895-906, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33573471

RESUMO

Scaffold-guided viral gene therapy is a novel, powerful tool to enhance the processes of tissue repair in articular cartilage lesions by the delivery and overexpression of therapeutic genes in a noninvasive, controlled release manner based on a procedure that may protect the gene vehicles from undesirable host immune responses. In this study, we examined the potential of transferring a recombinant adeno-associated virus (rAAV) vector carrying a sequence for the highly chondroregenerative transforming growth factor beta (TGF-ß), using poly(ɛ-caprolactone) (PCL) films functionalized by the grafting of poly(sodium styrene sulfonate) (pNaSS) in chondrogenically competent bone marrow aspirates as future targets for therapy in cartilage lesions. Effective overexpression of TGF-ß in the aspirates by rAAV was achieved upon delivery using pNaSS-grafted and ungrafted PCL films for up to 21 days (the longest time point evaluated), with superior levels using the grafted films, compared with respective conditions without vector coating. The production of rAAV-mediated TGF-ß by pNaSS-grafted and ungrafted PCL films significantly triggered the biological activities and chondrogenic processes in the samples (proteoglycan and type-II collagen deposition and cell proliferation), while containing premature mineralization and hypertrophy relative to the other conditions, with overall superior effects supported by the pNaSS-grafted films. These observations demonstrate the potential of PCL film-assisted rAAV TGF-ß gene transfer as a convenient, off-the-shelf technique to enhance the reparative potential of the bone marrow in patients in future approaches for improved cartilage repair.


Assuntos
Medula Óssea , Fator de Crescimento Transformador beta , Diferenciação Celular , Condrogênese , Terapia Genética , Vetores Genéticos/genética , Humanos , Fator de Crescimento Transformador beta/genética
18.
J Mater Sci Mater Med ; 21(2): 655-63, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19842019

RESUMO

The anchorage failure of titanium implants in human body is mainly due to biointegration problem. The proposed solution is to graft a bioactive polymer at the surface of the implant in order to improve and control the interactions with the living system. In this paper, we describe the grafting of poly sodium styrene sulfonate on titanium surface by using a silanization reaction. The key point is to increase the TiOH content at the surface of the implant which can react with methoxy silane groups of 3-methacryloxypropyltrimethoxysilane (MPS). Two procedures were used: chemical oxidation and electrochemical oxidation. The last oxidation procedure was carried out in two different electrolytes: oxalic acid and methanol. These different oxidation methods allow controlling the roughness and the depth of the oxide layer. The methacryloyl group of MPS grafted at the titanium surface by silanization reaction is copolymerized with sodium styrene sulfonate using a thermal initiator able to produce radicals by heating. Colorimetric method, ATR-FTIR, XPS techniques and contact angle measurements were applied to characterize the surfaces. MG63 osteoblastic cell response was studied on polished, oxidized and grafted titanium samples. Cell adhesion, Alkaline Phosphatase activity and calcium nodules formation were significantly enhanced on grafted titanium surfaces compared to un-modified surfaces.


Assuntos
Materiais Revestidos Biocompatíveis/química , Galvanoplastia/métodos , Osteoblastos/fisiologia , Polímeros/química , Ácidos Sulfônicos/química , Engenharia Tecidual/métodos , Titânio/química , Adesão Celular/fisiologia , Técnicas de Cultura de Células/métodos , Linhagem Celular , Proliferação de Células , Sobrevivência Celular , Cristalização/métodos , Humanos , Teste de Materiais , Osteoblastos/citologia , Oxirredução , Propriedades de Superfície
19.
Tissue Eng Part A ; 26(7-8): 450-459, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31680637

RESUMO

Scaffold-guided gene transfer offers strong systems to develop noninvasive convenient therapeutic options for the treatment of articular cartilage defects, especially when targeting bone marrow aspirates from patients containing chondroregenerative mesenchymal stromal cells in a native microenvironment. In this study, we examined the feasibility of delivering reporter (red fluorescent protein [RFP], lacZ) recombinant adeno-associated virus (rAAV) vectors over time to such samples through biocompatible mechanically stable poly(ɛ-caprolactone) (PCL) films grafted with poly(sodium styrene sulfonate) (pNaSS) for improved biological responses as clinically adapted tools for cartilage repair. Effective transgene expression (RFP, lacZ) was noted over time in human bone marrow aspirates using pNaSS-grafted films (up to 90% efficiency for at least 21 days) versus control conditions (ungrafted films, absence of vector coating on the films, free or no vector treatment), without displaying cytotoxic nor detrimental effects on the osteochondrogenic or hypertrophic potential of the samples. These findings demonstrate the potential of directly modifying therapeutic bone marrow from patients by controlled delivery of rAAV using biomaterial-guided procedures as a future noninvasive strategy for clinical cartilage repair. Impact statement Injured articular cartilage does not fully regenerate on itself and none of the currently available clinical and experimental therapeutic procedures are capable of restoring an original hyaline cartilage in sites of injury. Biomaterial-guided gene delivery has a strong potential to enhance the processes of cartilage repair. The system presented here based on the FDA-approved biocompatible poly(ɛ-caprolactone) material provides a functional scaffold for the controlled delivery of clinically adapted recombinant adeno-associated virus vectors as an off-the-shelf compound that could be applicable in a minimally invasive manner in patients.


Assuntos
Materiais Biocompatíveis/química , Poliésteres/química , Condrogênese/efeitos dos fármacos , Condrogênese/genética , Dependovirus/genética , Técnicas de Transferência de Genes , Vetores Genéticos/genética , Humanos , Transdução Genética
20.
Biointerphases ; 15(6): 061006, 2020 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-33203213

RESUMO

Polycaprolactone (PCL) is a widely used biodegradable polyester for tissue engineering applications when long-term degradation is preferred. In this article, we focused on the analysis of the hydrolytic degradation of virgin and bioactive poly(sodium styrene sulfonate) (pNaSS) functionalized PCL surfaces under simulated physiological conditions (phosphate buffer saline at 25 and 37 °C) for up to 120 weeks with the aim of applying bioactive PCL for ligament tissue engineering. Techniques used to characterize the bulk and surface degradation indicated that PCL was hydrolyzed by a bulk degradation mode with an accelerated degradation-three times increased rate constant-for pNaSS grafted PCL at 37 °C when compared to virgin PCL at 25 °C. The observed degradation mechanism is due to the pNaSS grafting process (oxidation and radical polymerization), which accelerated the degradation until 48 weeks, when a steady state is reached. The PCL surface was altered by pNaSS grafting, introducing hydrophilic sulfonate groups that increase the swelling and smoothing of the surface, which facilitated the degradation. After 48 weeks, pNaSS was largely removed from the surface, and the degradation of virgin and pNaSS grafted surfaces was similar. The cell response of primary fibroblast cells from sheep ligament was consistent with the surface analysis results: a better initial spreading of cells on pNaSS surfaces when compared to virgin surfaces and a tendency to become similar with degradation time. It is worthy to note that during the extended degradation process the surfaces were able to continue inducing better cell spreading and preserve their cell phenotype as shown by collagen gene expressions.


Assuntos
Poliésteres/química , Polímeros/metabolismo , Ácidos Sulfônicos/química , Animais , Soluções Tampão , Adesão Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Colágeno/genética , Colágeno/metabolismo , Fibroblastos/citologia , Fibroblastos/efeitos dos fármacos , Fibroblastos/metabolismo , Hidrólise , Polímeros/química , Polímeros/farmacologia , Ovinos , Espectroscopia de Infravermelho com Transformada de Fourier , Propriedades de Superfície , Engenharia Tecidual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA