Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Esthet Restor Dent ; 36(6): 951-961, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38497672

RESUMO

OBJECTIVE: To measure degree of conversion (DC) of a flowable composite, microtensile bond strength (MTBS) to dentine in the snow-plow technique with/without preheating and temperature in the preheated composite. MATERIALS AND METHODS: For DC, snow-plow specimens of Filtek Ultimate Flowable (Flow) and Filtek Bulk Fill (Bulk) (3M) were prepared by light-curing composites simultaneously in standardized molds while in control groups light-curing was separate. DC of Flow was measured using micro-Raman spectroscopy. For MTBS, specimens were prepared on dentine of human extracted molars by simultaneous (snow-plow) or separate (control) light-curing. MTBS was measured using a universal testing machine after 24 h and 6 months. Data were analyzed using ANOVA with Tukey's post hoc (α = 0.05). RESULTS: Increased curing time significantly increased DC in snow-plow from 13.4% ± 11.6% (10 s) to 31.8% ± 4.4% (40 s) albeit significantly lower than controls (p < 0.05). Preheated Bulk improved conversion in snow-plow (44.3% ± 1.7%) and control (50.5% ± 2.6%) (p < 0.05). No significant differences occurred in MTBS between groups (p > 0.05). MTBS values ranged between 66.7 ± 8.4 MPa (snow-plow group_21°C_baseline) and 54.1 ± 15.8 MPa (control_21°C_long-term). Temperature in the preheated Bulk dropped to ~38°C after 30 s. CONCLUSIONS: Snow-plow technique, irrespective of preheating, resulted in lower DC of Flow than separate light-curing of composite increments. Snow-plow, irrespective of preheating, resulted in similar initial and long-term MTBS to dentine. CLINICAL SIGNIFICANCE: Clinicians with preference for flowable composite liners in Class II restorations should be aware that the snow-plow technique of simultaneous light-curing of flowable and bulk-fill composite increments affects monomer-to-polymer conversion, albeit no effect on immediate, and long-term bonding to dentine was detected. Preheating sculptable bulk-fill composite improves conversion of the flowable liner in the snow-plow technique but has no detectable effect on bond strength to dentine.


Assuntos
Resinas Compostas , Colagem Dentária , Dentina , Resistência à Tração , Resinas Compostas/química , Humanos , Colagem Dentária/métodos , Teste de Materiais , Temperatura Alta , Análise Espectral Raman , Análise do Estresse Dentário
2.
Int J Mol Sci ; 24(3)2023 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-36768884

RESUMO

High elution and diffusion of 2-hydroxylethyl methacrylate (HEMA) and camphorquinone (CQ) through dentinal tubules may induce pulp injury and postoperative sensitivity. We aimed to investigate the melatonin protective effect in HEMA- and CQ-treated human dental pulp cells (hDPCs) as well as its relevance in a mechanism for postoperative sensitivity in diabetic patients. hDPCs were exposed to HEMA (5 mM) and/or CQ (1 mM) in the absence and presence of melatonin (MEL) (0.1 mM and 1 mM). Heme oxygenase-1 (HMOX1), NADPH oxidase-4 (NOX4), BCL-2-associated X-protein (BAX), B-cell lymphoma-2 (BCL-2) and caspase-3 (CASP3) gene expression levels, and superoxide dismutase (SOD) activity were measured in hDPCs while inducible nitric oxide synthase (iNOS) and melatonin protein expression were measured in human dental pulp as well, by RT-PCR, by ELISA, and spectrophotometrically. Bioinformatic analyses were performed by using the ShinyGO (v.0.75) application. Type 2 diabetic patients showed a higher incidence of postoperative sensitivity and lower melatonin and higher iNOS content in dental pulp tissue compared with non-diabetic patients. Melatonin, when co-added in hDPC culture, reverses HEMA and CQ cytotoxic effects via anti-apoptotic and anti-inflammatory/antioxidant iNOS-related effects. Enrichment analyses showed that genes/proteins, altered by HEMA and CQ and normalized by melatonin, are the most prominently overrepresented in type 2 diabetes mellitus pathways and that they share subcellular localization in different oligomeric protein complexes consisting of anti- and pro-apoptotic regulators. This is the first evidence of the ability of melatonin to counteract iNOS-mediated inflammatory and stress effects in HEMA- and CQ-treated hDPCs, which could be of significance for the modulation of presently observed immediate postoperative sensitivity after composite restoration in type 2 diabetic patients.


Assuntos
Diabetes Mellitus Tipo 2 , Melatonina , Humanos , Melatonina/farmacologia , Diabetes Mellitus Tipo 2/tratamento farmacológico , Metacrilatos/farmacologia , Óxido Nítrico Sintase Tipo II/genética , Óxido Nítrico Sintase Tipo II/metabolismo , Polpa Dentária/metabolismo , Antioxidantes , Proteínas Proto-Oncogênicas c-bcl-2/metabolismo
3.
Clin Oral Investig ; 26(11): 6817-6827, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35882680

RESUMO

OBJECTIVES: To evaluate CIEDE2000/CIELAB differences in color (ΔE00/ΔEab), and translucency parameter (ΔTP00/ΔTPab), and gloss of gingiva-colored resin-based restorative materials upon staining/aging. MATERIALS AND METHODS: Disc-shaped, 10 mm in diameter, and 2-mm-thick samples (n = 5/group) were made from giomer (Beautifil II gingiva), oligomer-based (crea.lign GUM gel), CAD/CAM polymethyl-methacrylate-based (IvoBase CAD), PMMA-based (ProBase Hot), and dimethacrylate-based (SR Nexco Paste Gingiva). Color and gloss were recording using a benchtop spectrophotometer and gloss meter, respectively, at baseline (T0), and upon staining in coffee or red wine for 60 (T1) and 120 h (T2), or artificial aging of 150 kJ/m2 (T1) and 300 kJ/m2 (T2). Three-way analysis of variance (materials x staining conditions x time intervals), Tukey's test (α = 0.05), and Pearson's correlation test were used in analytical statistics. RESULTS: CIEDE2000 color differences ranged from 1.0 to 4.4 (coffee), 1.5 to 5.3 (wine), and 0.9 to 2.0 after artificial aging, with ΔE00 values being significantly higher for Beautifil than other materials (p < 0.05). ΔTP00 values ranged from 0.2 to 0.7 and were statistically higher upon staining in wine compared to artificial aging (p < 0.05). Gloss values at T0 were 76.7-87.0. Beautifil exhibited the lowest gloss retention (50.8-60.2%) after staining, compared to > 90% of other materials (p < 0.05). ΔE00/ΔEab and ΔTP00/ΔTPab were positively correlated (p < 0.0001). CONCLUSIONS: Color, translucency, and gloss changes of gingiva-colored restorative materials were material- and staining/aging-dependent. Generally, wine caused greatest changes in color (with IvoBase CAD being the most color stable) and translucency parameter. All materials except Beautifil gingiva II exhibited staining- and aging-dependent gloss retention greater than 90% for all compared time intervals. CLINICAL RELEVANCE: Optical properties of resin-based gingiva-colored restorative materials depend on material, staining/aging conditions, and exposure time. Certain materials should be avoided in individuals with high consumption of red wine and coffee.


Assuntos
Café , Resinas Compostas , Humanos , Gengiva , Cor , Teste de Materiais , Materiais Dentários , Coloração e Rotulagem , Propriedades de Superfície
4.
J Evid Based Dent Pract ; 22(3): 101755, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36162880

RESUMO

ARTICLE TITLE AND BIBLIOGRAPHIC INFORMATION: Bonding of Glass-Ionomer Cement and Adhesives to Silver Diamine Fluoride-treated Dentin: An Updated Systematic Review and Meta-Analysis. Fröhlich TT, Botton G, Rocha RO. J Adhes Dent. 2022;24(1):29-38. SOURCE OF FUNDING: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - Brasil (CAPES) - Finance Code 001. TYPE OF STUDY/DESIGN: Systematic review with meta-analysis of data.


Assuntos
Colagem Dentária , Cimentos de Ionômeros de Vidro , Dentina , Fluoretos Tópicos , Cimentos de Ionômeros de Vidro/química , Cimentos de Ionômeros de Vidro/farmacologia , Humanos , Teste de Materiais , Compostos de Amônio Quaternário , Compostos de Prata
5.
J Esthet Restor Dent ; 33(6): 943-952, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33179862

RESUMO

OBJECTIVE: To analyze the effects of factors 'composite,' 'medium,' and 'time' on color, translucency, and sorption/solubility of sculptable universal composites for enamel layering upon immersion in colored beverages. MATERIALS AND METHODS: Disk-shaped specimens, 10 mm in diameter and 2 mm thick (n = 5/group), of ultrafine, hybrid composite Essentia (GC), microhybrid Gaenial Anterior (GC), nanofilled Filtek Ultimate Enamel and Body ( 3M ESPE) were immersed in red wine, coffee, or distilled water for 15 days. CIELab color coordinates were measured and CIEDE2000 (∆E00 ) and Translucency Parameter differences (∆TP00 ) were calculated. Sorption and solubility were determined according to ISO 4049:2009. Data were analyzed using the analyses of variance and Tukey's post-hoc test (α = 0.05). RESULTS: Essentia and Gaenial exhibited the lowest and the highest staining-dependent color differences, with mean ∆E00 range of 1.7-6.1 and 5.1-11.3, respectively (p < 0.05). ∆TP00 was more pronounced in wine than in coffee (p < 0.05). Sorption and solubility varied between 9.8 and 15.3 µg/mm3 and -1.6 and -5.4 µg/mm3 , respectively, with positive correlation between ∆TP00 and sorption (p = 0.005). CONCLUSIONS: Total color and translucency differences of sculptable composites for enamel layering were material-, time- and medium-dependent. Translucency differences positively correlated with sorption. Overall, the ultrafine, hybrid composite exhibited the best results in terms of color stability, sorption and solubility. CLINICAL SIGNIFICANCE: Clinicians should be aware of differences in color stability of sculptable composites for enamel layering as these are directly exposed to discoloration in the oral environment and are directly related to patients' long-term satisfaction and restoration longevity. Ultrafine, hybrid composite may be preferred due to better color stability, lower sorption and solubility compared to nanofilled and microhybrid composites evaluated in this study.


Assuntos
Resinas Compostas , Materiais Dentários , Bebidas , Cor , Esmalte Dentário , Humanos , Teste de Materiais , Solubilidade , Coloração e Rotulagem , Propriedades de Superfície , Água
6.
Clin Oral Investig ; 23(3): 1383-1396, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30022272

RESUMO

OBJECTIVES: The study aims to evaluate the effects of non-thermal atmospheric plasma (NTAP) treatments on dentin wetting and surface free energy (SFE) and compare the effects of NTAP treatment, etch-and-rinse, and self-etch protocols for application of universal adhesives. MATERIALS AND METHODS: Mid-coronal dentin of intact third molars was used to measure contact angles of distilled water, ethylene-glycol, and diiodomethane and calculate SFE following different NTAP preset treatments (feeding gas consisting of pure He, He + 1% O2, He + 1.5% O2), power input (1 or 3 W), and tip-to-surface distance (2, 4, or 8 mm). Contact angles of reference liquids and SFE of dentin following He + 1.5% O2 at 3-W and 4-mm treatment was compared to phosphoric acid etching. Contact angles of Single Bond Universal (SBU; 3M ESPE) and Clearfil Universal Bond (CUB; Kuraray Noritake) were measured following NTAP, etch-and-rinse, and self-etch protocols. RESULTS: NTAP significantly reduced contact angles of reference liquids and increased dentin SFE compared to untreated dentin (p < 0.05). O2 intensified the effect of He NTAP (p < 0.05). NTAP and phosphoric acid increased dentin polarity and Lewis base surface characteristics. Phosphoric acid increased contact angles of adhesives compared to the self-etch protocol (p < 0.05). NTAP resulted in lower adhesive contact angles than phosphoric acid, the difference being statistically significant for CUB (p < 0.05). Compared to the self-etch protocol, NTAP slightly reduced CUB contact angle but not that of SBU (p > 0.05). CONCLUSIONS: He NTAP with and without O2 increased dentin wetting and SFE, surpassing the effect of phosphoric acid and lowering adhesive contact angles. NTAP produced no apparent micro-morphological changes on dentin surface comparable to acid etching. CLINICAL SIGNIFICANCE: NTAP treatment of dentin prior to adhesive application increases dentin wetting and surface free energy facilitating better adhesive distribution on dentin surface compared to phosphoric acid etching and similar to the "self-etch" application protocol.


Assuntos
Colagem Dentária , Dentina , Gases em Plasma , Cimentos Dentários , Adesivos Dentinários , Teste de Materiais , Cimentos de Resina , Propriedades de Superfície , Resistência à Tração
7.
J Esthet Restor Dent ; 31(5): 520-528, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31580013

RESUMO

OBJECTIVE: To determine color changes in bulk-fill composite and universal composite restorations with dissimilar dentin replacement materials in extracted teeth after staining in red wine. MATERIALS AND METHODS: Cylindrical, 4 mm deep, class I cavities were prepared in 140 human molars. Bottom 2 mm was restored with Biodentine (Septodont), everX posterior (GC) or experimental HAP inserts. Each dentin replacement material was covered with a 2-mm layer of a universal composite Filtek Z250 or Z550 (3M ESPE) or Gradia Posterior (GC). Groups combining top composite layer and the underlying dentin replacement were designated as "composite_dentin replacement." Filtek Bulk Fill (3M ESPE) and Tetric EvoCeram Bulk Fill (Ivoclar Vivadent) were placed as a single 4-mm layer. Color measurements were performed using Vita Easyshade 4.0 (Vita Zahnfabrik) initially and after 48-hours storage in red wine at 37°C. RESULTS: Color differences (ΔEoo ) ranged between 2.1 ± 0.7 (Z250_HAP) and 7.8 ± 1.1 (Z550_everX). EverX resulted in higher ΔEoo of the overlying composite than HAP (P < .001) and Biodentine (P = .006). Generally, ΔEoo was affected more by decreasing lightness (ΔL') than changes in chroma (ΔC'). CONCLUSIONS: EverX resulted in higher ΔEoo of the restoration than Biodentine and experimental HAP after staining in red wine. No significant differences in ΔEoo may be expected in different composites with the same underlying dentin replacement material. The same was generally true for bulk-fill and universal composites. CLINICAL SIGNIFICANCE: Similar extent of color changes may be expected in bulk-fill and universal composites. Highly translucent everX might exhibit greater color differences irrespective of the capping composite than non-translucent materials. Clinicians have a wider choice of composite materials to cover a particular dentin replacement material, for example, everX or Biodentine, as similar color differences may be expected in various overlying composite brands.


Assuntos
Cárie Dentária , Materiais Dentários , Cor , Resinas Compostas , Dentina , Humanos , Teste de Materiais
8.
J Esthet Restor Dent ; 30(3): 240-248, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29377533

RESUMO

OBJECTIVES: The aim of this study was to test long-term microtensile bond strength (µTBS) of 2 universal adhesives applied to dentin following "total-etch" (TE) or "self-etch" (SE) protocols and aged by direct or indirect water exposure using simulated pulpal pressure. MATERIALS AND METHODS: Single Bond Universal (SBU, 3M ESPE) or Ipera Bond (IP, Itena) were applied to mid-coronal dentin ("flat dentin") or Class I cavity ("cavity dentin") following TE or SE protocols in 112 extracted human third molars. Sixteen groups (n = 7 per group) were prepared, 8 groups for µTBS measurements after 24 hours, and further 8 groups for measurements after 6 months storage. "Cavity dentin" groups were subjected to simulated hydrostatic pulpal pressure of 15 cm H2 O using a custom-made device before cutting 1 × 1 mm sticks while "flat dentin" groups were cut into sticks and directly exposed to deionized water. RESULTS: Generally, the TE protocol resulted in highest µTBS values on flat dentin initially for both adhesives (general linear model, P < .05). Long-term storage resulted in significantly lower µTBS values for the TE protocol (P < .05) while the SE protocol showed comparable values after 6 months (P > .05). "Cavity dentin" with simulated pulpal pressure resulted in lower µTBS than "flat dentin" (P < .05). For both adhesives, µTBS was in the range of 19-42 MPa initially and 16-36 MPa after 6 months storage. CONCLUSIONS: µTBS to dentin of universal adhesives is more stable in the long term following the SE than TE protocol. Simulated pulpal pressure and cavity-type sample preparation may be recommended for µTBS testing as a more clinically relevant strategy. CLINICAL SIGNIFICANCE: Microtensile bond strength to dentin of universal adhesives appears more stable following the "self-etch" than "total-etch" protocol after long-term degradation. More clinically relevant data may be obtained using simulated pulpal pressure and cavity-type sample preparation in the study design.


Assuntos
Colagem Dentária , Adesivos Dentinários , Resinas Compostas , Cimentos Dentários , Dentina , Humanos , Teste de Materiais , Cimentos de Resina , Resistência à Tração
9.
Clin Oral Investig ; 21(4): 1201-1212, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27383375

RESUMO

OBJECTIVES: The aim of this study was to determine and correlate the degree of conversion (DC) with Vickers hardness (VH) and translucency parameter (TP) with the depth of cure (DoC) of five bulk-fill composites. MATERIALS AND METHODS: Six specimens per group, consisting of Tetric EvoCeram Bulk Fill ("TEC Bulk," Ivoclar Vivadent), SonicFill (Kerr), SDR Smart Dentin Replacement ("SDR," Dentsply), Xenius base ("Xenius," StickTech; commercialized as EverX Posterior, GC), Filtek Bulk Fill flowable ("Filtek Bulk," 3M ESPE), and Tetric EvoCeram ("TEC," control), were prepared for DC and VH: two 2-mm-thick layers, each light-cured for 10 s; one 4-mm bulk-fill, light-cured for 10 or 20 s; and one 6-mm bulk-fill, cured for 20 s. DC was measured using a Fourier-transform infrared spectrometer, VH using a Vickers hardness tester. DoC and TP were measured using an acetone-shaking test and a spectrophotometer, respectively. Data were analyzed using ANOVA and Pearson's correlation (α = 0.05). RESULTS: DC and VH ranged between 40-70 % and 30-80 VHN, respectively. TEC Bulk, Xenius, and SonicFill, bulk-filled as 4-mm-thick specimens, showed bottom-to-top hardness ratios above 80 % after 20 s curing. A positive linear correlation was found for bottom DC and VH. An average DC ratio of 0.9 corresponded to a bottom-to-top VH ratio of 0.8. CONCLUSIONS: Sculptable bulk-fills require 20 s, whereas 10 s curing time was sufficient for flowable bulk-fills using a high-intensity LED unit. CLINICAL RELEVANCE: Clinicians should be aware that longer curing times may be required for sculptable than flowable bulk-fill composites in order to achieve optimal curing characteristics.


Assuntos
Resinas Compostas/química , Materiais Dentários/química , Dureza , Testes de Dureza , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Polimerização , Espectroscopia de Infravermelho com Transformada de Fourier , Propriedades de Superfície
10.
Int Dent J ; 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38762371

RESUMO

INTRODUCTION AND AIMS: This study aimed to evaluate the relative dentin abrasivity of whitening toothpastes containing acids using the Radioactive Dentin Abrasivity - Profilometry Equivalent (RDA-PE). METHODS: A total of 100 bovine dentin specimens were prepared and assigned to the following groups (n = 10): 5 hydrogen peroxide (HP) whitening toothpastes (WTH1-WTH5) with or without acid (citric acid, ethylenedinitrilotetraacetic acid disodium, and phosphoric acid), 2 whitening toothpastes with silica and containing citric or phosphoric acid (WTS1 and WTS2), one conventional toothpaste (CT), and 2 reference slurries (RS). All specimens were brushed for 4,000 or 10,000 strokes using toothbrush and toothbrushing machine. The average dentin depth was measured using a noncontact profilometery, and the RDA-PE value was calculated based on the RS. The pH of the solution, average particle size, particle content, and particle hardness were measured. The RDA-PE data were analysed using one-way analysis of variance and Tukey's test, and the effects of the 4 measured factors on RDA-PE were investigated via multiple regression analysis. RESULTS: The RDA-PE values of the HP whitening toothpastes (mean value: 19-46) were significantly lower, whereas those of the silica whitening toothpastes (80 or 111) were similar to those of the RS after 4,000 strokes (100). The RDA-PE values of all whitening toothpastes were significantly lower than the RS values after 10,000 strokes (242). The HP whitening toothpastes were slightly acidic (pH ≤6) compared to the other solutions. The HP (2.9%-3.7%) and silica (8.9% or 9.9%) whitening toothpastes had significantly lower particle content than RS (16.6%). The particle content significantly influenced the RDA-PE values by multiple regression results. CONCLUSIONS: The RDA-PE values of whitening toothpastes varied. The particle content in the solution was a key factor affecting the RDA-PE value. CLINICAL RELEVANCE: Whitening toothpastes containing acids did not cause significant dentin abrasion.

11.
J Biomed Mater Res B Appl Biomater ; 112(1): e35331, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37792306

RESUMO

This study aimed to (1) comparatively analyze properties of Sr- and Mg-substituted hydroxyapatite (HAP)-based dental inserts; (2) evaluate insert bonding to restorative materials, and (3) evaluate the effect of doped HAP inserts on fracture resistance (FR) of human molars with large occlusal restorations. By ion-doping with Sr or Mg, 3 insert types were obtained and characterized using XRD, SEM, Vickers hardness and fracture toughness. Shear bond strength (SBS) was determined between acid etched or unetched inserts and following materials: Maxcem cement (Kerr); Filtek Z250 (3M) bonded with Single Bond Universal (SBU; 3M) or Clearfil Universal (Cf; Kuraray). Modified Class I cavities were prepared in 16 intact molars and restored using insert + composite or composite only (control) (n = 8/group). FR of restored molars was determined by static load until fracture upon thermal cycling. Fracture toughness was similar between Sr/Mg-doped inserts (0.94-1.04 MPam-1/2 p = .429). Mg-doped inserts showed greater hardness (range 4.78-5.15 GPa) than Sr6 inserts (3.74 ± 0.31 GPa; p < .05). SBS for SBU and Cf adhesives (range 7.19-15.93 MPa) was higher than for Maxcem (range 3.07-5.95 MPa) (p < .05). There was no significant difference in FR between molars restored with insert-containing and control restorations (3.00 ± 0.30 kN and 3.22 ± 0.42 kN, respectively; p > .05). HAP-based inserts doped with Mg/Sr had different composition and mechanical properties. Adhesive bonding to inserts resulted in greater bond strength than cementation, which may be improved by insert acid-etching. Ion-doped HAP inserts did not affect FR of restored molars. In conclusion, HAP-based dental inserts may potentially replace dentin in large cavities, without affecting fracture resistance of restored teeth.


Assuntos
Colagem Dentária , Fraturas Ósseas , Humanos , Durapatita , Adesivos Dentinários/química , Resinas Compostas/química , Dente Molar , Cimentos de Resina/química , Cimentos de Ionômeros de Vidro/química , Teste de Materiais , Análise do Estresse Dentário
12.
J Dent Educ ; 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38795331

RESUMO

OBJECTIVES: To evaluate the effects of enhanced personal protective equipment (Enhanced_PPE) on student-operator's experience and restorative procedure. METHODS: Student-operators (N = 29 Year 3 dental students) performed Class II composite restorations (SimpliShade, Kerr) in typodont upper molars (OneDental) equipped with N95 respirators, full-face shields, disposable headwear and gowns (Enhanced_PPE) or surgical masks, protective glasses/goggles and non-disposable gowns (Standard_PPE) 2 weeks later. Cavity dimensions were measured on cone beam computed tomography images. The quality of composite restorations was assessed using selected FDI criteria and Vickers hardness. A questionnaire assessed the operators' discomfort, anxiety, confidence, ability to perform, and procedure outcome. Data were analyzed using paired t-test and McNemar test (alpha = 0.05). RESULTS: Student-operators experienced greater discomfort and anxiety, reduced confidence and ability to perform, and rated the procedure as less satisfactory with Enhanced_PPE (p < 0.05). Differences in proximal box width were marginally significant (Enhanced_PPE 1.8 ± 0.4 mm, Standard_PPE 1.6 ± 0.3 mm) (p = 0.047). Other cavity dimensions were similar between groups (p > 0.05) as were restorations regarding surface luster, anatomical form, marginal adaptation, proximal contour, and contact (p > 0.05). There were no differences in the hardness of composite restorations (top p = 0.349, bottom p = 0.334). CONCLUSIONS: Enhanced_PPE led to student-operator discomfort, anxiety, and reduced confidence, but did not impact the quality of Class II preparation and composite restorations versus Standard_PPE.

13.
Inorg Chem ; 52(3): 1238-47, 2013 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-23330645

RESUMO

Copper(II) complexes of hexadentate ethylenediaminetetracarboxylic acid type ligands H(4)eda3p and H(4)eddadp (H(4)eda3p = ethylenediamine-N-acetic-N,N',N'-tri-3-propionic acid; H(4)eddadp = ethylenediamine-N,N'-diacetic-N,N'-di-3-propionic acid) have been prepared. An octahedral trans(O(6)) geometry (two propionate ligands coordinated in axial positions) has been established crystallographically for the Ba[Cu(eda3p)]·8H(2)O compound, while Ba[Cu(eddadp)]·8H(2)O is proposed to adopt a trans(O(5)) geometry (two axial acetates) on the basis of density functional theory calculations and comparisons of IR and UV-vis spectral data. Experimental and computed structural data correlating similar copper(II) chelate complexes have been used to better understand the isomerism and departure from regular octahedral geometry within the series. The in-plane O-Cu-N chelate angles show the smallest deviation from the ideal octahedral value of 90°, and hence the lowest strain, for the eddadp complex with two equatorial ß-propionate rings. A linear dependence between tetragonality and the number of five-membered rings has been established. A natural bonding orbital analysis of the series of complexes is also presented.


Assuntos
Cobre/química , Etilenodiaminas/química , Compostos Organometálicos/química , Teoria Quântica , Cristalografia por Raios X , Ligantes , Modelos Moleculares , Estrutura Molecular , Compostos Organometálicos/síntese química
14.
Dent Mater ; 39(12): 1085-1094, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37827872

RESUMO

OBJECTIVES: To answer the PICO(S) question: Is there a difference in clinical longevity between direct and indirect resin composite restorations placed on permanent posterior teeth? DATA: Randomized controlled clinical trials (RCTs) investigating direct and indirect resin composite restorations in posterior permanent teeth were considered. SOURCES: Several electronic databases were searched, with no language or date restrictions. The revised Cochrane Collaboration's tool for assessing risk of bias (RoB-2) was used to analyze the studies; meta-analyses were run and the certainty of evidence was assessed by the GRADE tool. A subgroup meta-analysis was performed for resin composite restorations placed on posterior worn dentition. STUDY SELECTION: Twenty-three articles were included in qualitative synthesis, while 8 studies were used for meta-analyses. According to the RoB-2 tool, 5 studies were ranked as "low risk", 7 had "some concerns", while 11 papers were rated as "high risk" of bias. There were no statistically significant differences in short-term (p = 0.27; RR=1.54, 95% CI [0.72, 3.33]), medium-term (p = 0.27; RR=1.87, 95% CI [0.61, 5.72]) and long-term longevity (p = 0.86; RR=0.95, 95% CI [0.57, 1.59]). The choice of restorative technique had no influence on short-term survival of resin composite restorations placed on worn dentition (p = 0.13; RR=0.46, 95% CI [0.17, 1.25]). The certainty of evidence was rated as "very low". CONCLUSIONS: Direct and indirect resin composite restorations may show similar clinical longevity in posterior region, regardless of the observation period or substrate (wear-affected and non-affected dentition). The very low quality of evidence suggests that more long-term RCTs are needed to confirm our results.


Assuntos
Resinas Compostas , Restauração Dentária Permanente , Restauração Dentária Permanente/métodos , Resinas Compostas/uso terapêutico , Dente Molar
15.
Int J Dent ; 2022: 8048265, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35449763

RESUMO

Objectives: This retrospective study evaluated the factors influencing the clinical failure of noncarious cervical lesion (NCCL) restorations. Methods: Patients were routinely treated by undergraduate or postgraduate students and randomly received a clinical recall evaluation. A retrospective study was performed with two experienced calibrated examiners to evaluate NCCL restorations, including the critical parameters of retention, caries, marginal discoloration, and marginal integrity. The factors related to the restoration included gender, age, arch site, tooth position, the presence of occlusal wear facets, caries risk, operator, adhesive strategy, and composite. The clinical failure comparison between the parameters and factors was performed using the binary logistic regression analysis. Results: A total of 460 cervical restorations from 96 patients were evaluated. The adhesive strategy and the presence of occlusal wear facets were the most important factors influencing the parameter failure. Therefore, the highest failure was marginal integrity, in which the gingival marginal integrity failure was 50.7%, and the occlusal marginal integrity failure was 42.4%. Conclusions: The main factors influencing clinical failure for partial loss, marginal discoloration, and marginal integrity were the adhesive strategy and the presence of occlusal wear facets. Therefore, marginal integrity was the most frequent failure parameter.

16.
Sci Rep ; 12(1): 9944, 2022 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-35705613

RESUMO

This study investigated differences in colour (ΔE00) and translucency parameter (ΔTP00) of nanofilled/microhybrid composites and a glass-ionomer cement following immersion in bioflavonoid (Citrox)- or chlorhexidine-based mouth rinses. Sixty disc-shaped specimens (N = 5/group) of Filtek Supreme (3M), Gradia Anterior (GC) and Fuji IX (GC) were exposed to Citrox/0.2%CHX (Perio+0.2, Curaprox), Citrox/0.09%CHX (Perio+0.09, Curaprox), 0.2%CHX (Savacol, Colgate-Palmolive) or distilled water by 2-min agitation daily for 28 days in an orbital shaker at 200 rpm at 37 °C. Colour recordings were performed using a clinical spectrophometer to obtain CIELab coordinates. General linear model, ANOVA, Tukey test (α = 0.05) and Pearson correlation test were used to analyse data. ΔE00 ranged between 0.33 (Gradia_Savacol_T28) and 6.35 (Fuji_Savacol_T28) (p < 0.001). ΔTP00 ranged between 0.36 (Fuji_ Perio+0.2) and 1.73 (Fuji_Savacol) (p < 0.05). Savacol resulted in higher ΔE00 of Filtek and Fuji and ΔTP00 of Filtek than Perio+0.09 and Perio+0.2 (p = 0.005). Perio+0.09 and Perio+0.2 resulted in higher ΔE00 at T7 than T28 (p < 0.05). There was no correlation between ΔTP00 and ΔE00 (r = 0.445, p = 0.147). Generally, Perio+0.2 and Perio+0.09 mouth rinses produced similar or lower ΔE00 and ΔTP00 than Savacol. GIC Fuji showed higher ΔE00 and similar or higher ΔTP00 than composites Filtek and Gradia. ΔE00 in all materials decreased in Perio+0.2 and Perio+0.09 over time.


Assuntos
Flavonoides , Antissépticos Bucais , Resinas Compostas , Teste de Materiais
17.
PLoS One ; 16(10): e0257359, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34648503

RESUMO

BACKGROUND: The outbreak of COVID-19 pandemic in 2020 has dramatically changed teaching approach in dental schools due to the switch to distance learning and the lack of practice training in direct contact with patients with possible impact on clinical skills of students. The aim of the study was to assess the level of the 2020 final year dental students' self-confidence in performing different dental procedures through specially designed questionnaire and compare it to self-confidence of the 2019 final year students. MATERIALS AND METHODS: An anonymous questionnaire consisting of 40 questions regarding self-confidence level in performing 40 different dental procedures and based on five points Likert-like scale was distributed during November 2020 to final year dental students whose studies were disrupted by the COVID-19 pandemic lockdown in one semester. The study group comprised their answers. The comparison was done with the control group that consisted of students' answers on the same questionnaire from previous 2019 year conducted as a part of regular internal educational evaluation. RESULTS: Response rate was 74.2% in study group and 89.3% in control group. Mean level of self-confidence reported by 115 students in study group was significantly lower than that reported by 100 students in control group (3.28±1.08 vs. 3.58±0.88, respectively) and the distribution of self-confidence scores were different in observed groups. Graduates from study group felt less confident than those from control in 8 clinical skills. CONCLUSION: Abrupt changes in teaching modalities caused by COVID-19 pandemic had significant impact on final year dental students' self-confidence indicating additional educational needs in postgraduate period.


Assuntos
Competência Clínica , Educação em Odontologia , Autoimagem , Estudantes de Odontologia , COVID-19 , Humanos , Pandemias , Inquéritos e Questionários
18.
J Dent ; 112: 103765, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34363890

RESUMO

OBJECTIVES: This systematic review and meta-analysis evaluated the effects of non-thermal atmospheric plasma (NTAP) treatment on dentin wetting and adhesive-dentin bond strength. DATA/SOURCES: This report followed the PRISMA 2020 statement. Two reviewers conducted literature search of MEDLINE, Web of Science and Scopus databases up to the end of November 2020. Included in vitro studies compared the effect of NTAP on treated dentin of non-carious, intact, extracted human third molar teeth with different control groups. Studies with no adequate methods, missing data, lack of control group, or those using animal teeth were excluded. The random effects model was used to summarize the treatment effect with standardized mean difference (SMD) and 95% CI. Risk of bias was assessed using the custom Cochrane Collaboration's tool. STUDY SELECTION/RESULTS: Seventeen studies met inclusion criteria. The effects on dentin wetting were reported in favor of NTAP (SMD -5.38; 95% CI [-6.97, -3.78]; p<0.00001; I2=81%). Regarding adhesive-dentin bond strength, statistically significant differences between the NTAP and control group were in favor of NTAP in the short-term (SMD 1.92; 95%CI [1.35, 2.50]; p<0.00001; I2=97%), and long-term (SMD 3.28; 95%CI [2.46, 4.09]; p<0.00001; I2=97%). A limitation of meta-analysis is moderate heterogeneity caused by methodological differences and lack of data, which was evaluated through risk of bias and sensitivity analysis. CONCLUSIONS: NTAP substantially improves dentin wetting and adhesive-dentin bond strength with 30 seconds exposure time and up to 10 mm tip-to-surface distances being sufficient for positive NTAP effects on bonding efficiency. FUNDING: ON172207 and III41008 from the Ministry of Education, Science and Technological Development, Republic of Serbia. NP is funded by MESTD grant number 451-03-68/2020-14/200024. CLINICAL SIGNIFICANCE: This systematic review and meta-analysis substantiate potential applicability of NTAP treatment of dentin in improving adhesive bonding clinically. Further research should be based on the optimized parameters such as time and distance with additional refinement of NTAP power.


Assuntos
Colagem Dentária , Gases em Plasma , Animais , Cimentos Dentários , Dentina , Adesivos Dentinários , Humanos , Teste de Materiais , Gases em Plasma/uso terapêutico , Cimentos de Resina
19.
Dent Mater J ; 40(6): 1380-1387, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34305050

RESUMO

The aim of this study was to compare color changes, surface roughness and gloss of a microhybrid and nanohybrid composite whitened in a simulated in-office or at-home procedure using 40% hydrogen peroxide or 16% carbamide peroxide, respectively. CIELab coordinates were measured before, during and after treatment using VITA EasyShade V (VITA) and ∆E00 calculated. Surface roughness was measured using a surface roughness tester (SJ210; Mitutoyo). Gloss was measured using a gloss checker (IG-331; Horiba). At-home whitening resulted in ∆E00 of 1.23±0.49 (microhybrid) and 1.01±0.76 (nanohybrid). In-office exposure resulted in ∆E00 of 0.69±0.38 (microhybrid) and 0.72±0.50 (nanohybrid). There were no significant differences in ∆E00, surface roughness and gloss between whitening protocols (p>0.05). Color changes of a microhybrid and nanohybrid composite following simulated in-office or at-home whitening reached CIEDE2000 50:50% perceptibility but not acceptability threshold. Surface roughness and gloss of the microhybrid and nanohybrid composite were not affected by whitening.


Assuntos
Resinas Compostas , Peróxido de Hidrogênio , Peróxido de Carbamida , Cor , Géis , Propriedades de Superfície
20.
Materials (Basel) ; 14(19)2021 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-34640052

RESUMO

The objective of this work was to measure and correlate the degree of conversion (DC), mechanical properties and monomer elution from self-, dual- and light-cured core composites. Five samples of each of the following materials were prepared for each test: Clearfil (Core, Photo Core, Automix), Bisco (Core-Flo, Light-Core and Bis-Core). DC was determined using FTIR, compressive and flexural strength and modulus of elasticity using a universal testing machine and microhardness using Vickers hardness. Elution was measured using HPLC. One-way ANOVA with Tukey's post-test and Pearson's correlation were used to statistically analyze the data. DC of Clearfil-Dual (70.1%) and Clerafil-Photo (66.8%) were higher than Clearfil-Self (55.4%) and all Bisco materials (51.4-55.3%). Flexural strength of Clearfilwas higher than that of Bisco composites. The Microhardness of Clearfil-Dual (119.8VHN) and Clearfil-Photo (118.0VHN) were higher compared to other materials. The greatest elution was detected from self-cured materials. DC positively correlated to microhardness and compressive/flexural strength and negatively to BisGMA elution. Clearfil-Photo and Automix showed higher conversion, lower monomer elution and, generally, better mechanical properties. Self-cured composites should not be recommended for routine clinical use as their performance was inferior to dual- and light-cured composites. Microhardness may be used as an indicator of elution.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA