Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Arthroscopy ; 38(3): 881-891, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34252561

RESUMO

PURPOSE: To contribute to future quadriceps tendon harvest and fixation guidelines in the setting of anterior cruciate ligament reconstruction by comparing 2-year patient-reported subjective knee outcome scores and incidence of graft-related complications between the shorter harvest all-inside tibial-femoral suspensory fixation (TFSF) approach versus the longer harvest standard tibial interference screw fixation technique. METHODS: Patients who underwent primary anterior cruciate ligament reconstruction with all soft tissue quadriceps tendon autograft from January 2017 to May 2019 were identified for inclusion. Patients were matched into 2 cohorts of 62 based on reconstruction technique. All patients completed baseline and minimum 2-year International Knee Documentation Committee, Tegner Activity Level, and Lysholm questionnaires and were queried regarding subsequent procedures and complications to the operative knee. RESULTS: Average graft length for the all-inside TFSF was 69.55 (95% confidence interval 68.99-70.19) mm versus 79.27 (95% confidence interval 77.21-81.34) mm in the tibial screw fixation cohort (P = .00001). Two-year Lysholm scores were greater in the TFSF cohort (P = .04) but were not clinically significant. There was no difference in 2-year International Knee Documentation Committee (P = .09) or Tegner (P = .69) scores between cohorts, but more patients in the TFSF cohort returned to or exceeded their baseline activity level compared with the tibial screw fixation cohort (73% vs 61%, P = .25). Seven patients in the TFSF cohort versus 13 in the tibial screw fixation cohort reported anterior knee pain or kneeling difficulty (P = .22). There were no differences in reported complications. CONCLUSIONS: All-inside soft-tissue quadriceps tendon autograft with TFSF resulted in clinically comparable subjective outcome scores at 2 years to tibial screw fixation. There were also no differences in complications or reports of anterior knee pain or kneeling difficulty. All-inside TFSF can be a viable alternative to tibial screw fixation for all-soft tissue quadriceps autograft. LEVEL OF EVIDENCE: III, comparative therapeutic trial.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Autoenxertos , Parafusos Ósseos , Humanos , Articulação do Joelho/cirurgia , Tendões/transplante
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA