BMC Musculoskelet Disord ; 25(1): 271, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589829

RESUMO

BACKGROUND: Single limb support phase of the gait-cycle in patients who are treated for a pertrochanteric fracture is characterized by transversal loads acting on the lag screw, tending to block its dynamization. If the simultaneous axial force overcomes transversal loads of the sliding screw, the dynamization can still occur. METHODS: Biomechanical investigation was performed for three types of dynamic implants: Gamma Nail, and two types of Selfdynamizable Internal Fixators (SIF) - SIF-7 (containing two 7 mm non-cannulated sliding screws), and SIF-10 (containing one 10 mm cannulated sliding screw). Contact surface between the stem and the sliding screws is larger in SIF implants than in Gamma Nail, as the stem of Gamma Nail is hollow. A special testing device was designed for this study to provide simultaneous application of a controlled sliding screws bending moment and a controlled transversal load on sliding screws (Qt) without using of weights. Using each of the implants, axial forces required to initiate sliding screws dynamization (Qa) were applied and measured using a tensile testing machine, for several values of sliding screws bending moment. Standard least-squares method was used to present the results through the linear regression model. RESULTS: Positive correlation between Qt and Qa was confirmed (p < 0.05). While performing higher bending moments in all the tested implants, Qa was higher than it could be provided by the body weight. It was the highest in Gamma Nail, and the lowest in SIF-10. CONCLUSIONS: A larger contact surface between a sliding screw and stem results in lower forces required to initiate dynamization of a sliding screw. Patients treated for a pertrochanteric fracture by a sliding screw internal fixation who have longer femoral neck or higher body weight could have different programme of early postoperative rehabilitation than lighter patients or patients with shorter femoral neck.


Assuntos
Parafusos Ósseos , Fraturas do Fêmur , Humanos , Parafusos Ósseos/efeitos adversos , Fenômenos Biomecânicos , Fixadores Internos , Fixação Interna de Fraturas , Fraturas do Fêmur/etiologia , Peso Corporal
2.
Int Orthop ; 45(4): 871-876, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32617652

RESUMO

PURPOSE: Acetabular fractures are accompanied by complications such as post-traumatic osteoarthritis (OA) of the hip and avascular necrosis (AVN) of the femoral head. The aim of the study was to evaluate improvement of life quality and functional recovery after total hip arthroplasty (THA) in patients with post-traumatic OA and AVN. METHODS: We retrospectively reviewed 23 patients with post-traumatic OA of the hip and AVN of the femoral head who undergone THA, out of 63 patients who were previously surgically treated for acetabular fractures. Final functional outcomes are defined according to the Merle d'Aubigné score, and the pain intensity according to VAS from 0 to 10. RESULTS: Out of 63 patients with acetabular fractures from 2008 to 2018, we analyzed 23 (36.5%) patients, with an average age of 51.5 ± 13.8 years, who required THA due to post-traumatic OA and AVN of the femoral head. THA was done after the average of 4.28 years (range 1 to 8) from previous acetabular osteosynthesis. According to Merle d'Aubigné score, final functional outcomes before THA were moderate with average points of 4.86 (4-6). Post-THA final functional outcomes were excellent with an average point of 10.04 (10-12) (p < 0.001). The ratio of VAS before and after THA was 9.04:1.95(p < 0.001). CONCLUSION: THA is a method which gives the best results in the treatment of post-traumatic OA of the hip and AVN of the femoral head after previous osteosynthesis of the acetabular fracture. After THA, life quality and functional status of a patient are significantly improved.


Assuntos
Artroplastia de Quadril , Acetábulo/cirurgia , Adulto , Idoso , Artroplastia de Quadril/efeitos adversos , Humanos , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
3.
Int Orthop ; 45(4): 1071-1076, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32740756

RESUMO

PURPOSE: Tibial plateau fractures are severe intra-articular injuries; their treatment is accompanied by numerous complications and requires extensive surgical experience. In this manuscript, we compared our experiences with data from the literature. METHODS: Retrospectively, we analyzed 41 patients with closed lateral tibial plateau fracture (Schatzker's I-III). All fractures were treated surgically with open reduction and internal plate fixation. Post-operative complications and final outcomes were monitored according to the Tegner Lysholm Knee Scoring System. The average follow-up was 5.7 years (2-10). RESULTS: We analyzed 41 patients (Schatzker I-III), average age 46.7 ± 13.0 years. Traumatic lesion of the lateral meniscus was present in 15 (36.58%) patients. Post-traumatic knee osteoarthritis was present in all (100%) patients after lateral meniscectomy and in 20% of patients it occurred after meniscus repair (p = 0.007). Post-traumatic knee osteoarthritis was present in 12 (29.68%) patients. Infection occurred in five (12.19%) patients, DVT in three (7.3%) patients, and we had one (2.43%) case of non-lethal PE. Final functional outcomes were excellent in 13 (31.7%), good in 21 (51.21%), moderate in five (12.19%), and poor in two (4.87%) patients. CONCLUSION: Lateral tibial plateau fractures are severe intra-articular injuries which can leave lasting consequences, regardless of the restoring of the articular surface and stable internal fixation. Local skin condition and associated soft tissue injuries, comminution, degree of dislocation, and depression can significantly affect the development of post-traumatic osteoarthritis and poor outcomes.


Assuntos
Fixação Interna de Fraturas , Fraturas da Tíbia , Adulto , Placas Ósseas , Fixação Interna de Fraturas/efeitos adversos , Humanos , Pessoa de Meia-Idade , Redução Aberta/efeitos adversos , Estudos Retrospectivos , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Resultado do Tratamento
4.
Int Orthop ; 45(4): 815-820, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32728928

RESUMO

PURPOSE: After the appearance of first COVID-19 cases in Serbia, state of emergency was declared on 15 March 2020 and lasted for 54 days. The aim of this report is to compare orthopaedic fracture frequencies in this period, when the walk was limited at the home mostly, with those during the same part in the previous year with regular state, thus to examine staying at home as a factor influencing the frequency of different fracture types. METHODS: There were 86 patients during the state of emergency in year 2020 and 106 patients during the same part of year 2019 with a regular state, having orthopaedic trauma surgery. Number of fractures, gender distribution, and age of patients have been compared between these periods. RESULTS: Total number of fractures decreased for about 19% during the state of emergency. There was nonsignificant difference in fracture frequency for all skeletal areas (p > 0.05), except for distal femoral fractures which occurred more often during the state of emergency (p < 0.05). Female ratio was higher during state of emergency than in regular state for femoral neck fractures. CONCLUSION: Restricted going outside the home for 54 days has the influence in total number of fractures and gender distribution in femoral neck fractures. The method of external fixation used could be assumed as a reducing factor of intraoperative virus pandemic propagation among medical staff.


Assuntos
COVID-19 , Fraturas do Colo Femoral , Ortopedia , Feminino , Fixação Interna de Fraturas , Humanos , Pandemias , SARS-CoV-2
8.
Unfallchirurgie (Heidelb) ; 127(3): 246-250, 2024 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-37801096

RESUMO

Fractures of the tibial pilon are severe injuries which can be accompanied by articular impaction, comminution and soft tissue injury. Soft tissue injury with already existing skin damage can further complicate the method of treatment. In these cases, the method of unilateral or circular external fixation can be used as an alternative method of treatment. Minimally invasive percutaneous osteosynthesis with spanning rigid and dynamic unilateral external fixation as a one-stage method has been used for the treatment of intra-articular pilon fractures. We report a case of a patient with an intra-articular pilon fracture with chronic venous insufficiency and venous ulcer, who was injured after falling from a height and who had emergency surgery based on capsuloligamentotaxis and percutaneous osteosynthesis with a spanning unilateral external fixator. The patient was mobilized postoperatively for walking without weight bearing on the injured leg. The initial rigid spanning external fixation was transformed into dynamic fixation to enable ankle joint movements 8 weeks after surgery. The external fixator was removed 4.5 months after surgery and the Kirschner wire and screws were removed 7 months after surgery. The final functional result 1 year after the injury was good and motion of upper ankle joint was moderately restricted without pain. Swelling occurred after walking for longer distances.


Assuntos
Traumatismos do Tornozelo , Fraturas Intra-Articulares , Lesões dos Tecidos Moles , Fraturas da Tíbia , Humanos , Resultado do Tratamento , Seguimentos , Fixadores Externos , Fixação de Fratura , Traumatismos do Tornozelo/cirurgia , Fraturas da Tíbia/diagnóstico por imagem
9.
Eur J Trauma Emerg Surg ; 48(1): 613-619, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32929549

RESUMO

PURPOSE: Traumatic hip dislocation can be isolated or associated with acetabular fracture. Both injuries require emergency reduction of the dislocated hip. Avascular necrosis of the femoral head (AVN) is a potential complication that accompanies these severe injuries. Our objective is to identify the risk factors that cause AVN. METHODS: We retrospectively analyzed 44 patients with traumatic hip dislocations (Group A) and patients with posterior fracture-dislocation of the acetabulum (Group B). The average follow-up was 5.38 years in Group A, 5.59 years in Group B. We used the Thompson-Epstein classification for hip dislocation and the Harris Hip Score (HHS) for evaluating final outcomes. RESULTS: In Group A, we analyzed 21 patients with isolated posterior hip dislocation. We had one (4.76%) case of AVN. In Group B, we analyzed 23 patients with posterior acetabular fracture-dislocation. We had eight (34.78%) patients with AVN (p = 0.016, p < 0.05). With hip reduced 6-12 h after injury, we had AVN in one (4.34%) patient, with reduction 12-24 h, AVN was present in two (8.69%), while in hip reduction done after 24 h of injury, AVN was present in five (21.73%) patients (p = 0.030, p < 0.05). CONCLUSION: An essential prerequisite for the prevention of AVN of the femoral head after hip dislocation is emergency hip reduction. In acetabular fracture-dislocation, emergency hip reduction, anatomical reduction of the acetabular fracture and early stable osteosynthesis are also important. Main factor affecting the development of AVN is late reduction of the hip.


Assuntos
Necrose da Cabeça do Fêmur , Luxação do Quadril , Fraturas do Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Cabeça do Fêmur , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Necrose da Cabeça do Fêmur/etiologia , Luxação do Quadril/diagnóstico por imagem , Luxação do Quadril/cirurgia , Humanos , Estudos Retrospectivos , Resultado do Tratamento
10.
Inquiry ; 58: 469580211067497, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34908506

RESUMO

The main component of error minimization in operating rooms (ORs) is to maintain high reliability of surgical teams. The analysis of adverse events in the OR reveals deficiencies in cognitive and interpersonal skills as the main factors influencing surgeons' errors. Therefore, research of these additional factors is necessary, besides factors related to surgeons' clinical knowledge and technical skills. In this paper, the key factors for evaluating activities in surgical operating rooms are identified. Fuzzy analytic hierarchy process is used for identification of key factors. Fifteen key factors are identified for evaluating activities in surgical operating rooms to improve the efficiency of surgical operations. For each group of activities (surgical "capabilities," operating room characteristics, and non-technical skills), five factors are identified. As the most important, the following factors are obtained: communication, indoor environment standardization, and tool handle design. The aim of the analysis of these key factors is surgeons' work capability enhancement, rational design of operating rooms, and advancement of operators' cognitive and interpersonal skills.


Assuntos
Salas Cirúrgicas , Cirurgiões , Comunicação , Humanos , Reprodutibilidade dos Testes
11.
Eur J Trauma Emerg Surg ; 46(5): 1123-1127, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30382315

RESUMO

PURPOSE: Tibial shaft fractures are the most common type of large long-bone fractures. Segmental tibial shaft fractures are severe injuries and its treatment can be followed by a high incidence of complications, nonunion, delayed union, malunion, infection or compartment syndrome. The most common treatment strategy is intramedullary fixation. Results of the unilateral external fixation treatment for segmental tibial shaft injuries are presented in this paper. METHODS: Patients with segmental tibial shaft fractures, AO/OTA 42-C2 were treated as urgent cases by unilateral external fixation. Mitkovic-type external fixator was used in all of these fractures. RESULTS: There were 32 patients with segmental tibial shaft fractures (AO/OTA 42-C2), 20 males and 12 females, average age of 43.5 years. Average time of union was 5.9 (4.1-7.4) months for closed and 6.2 (5.1-7.9) months for open fractures. Average follow-up was 18 (26-60) months. Nine patients (28.12%) had open segmental tibial shaft fracture (2 Grade I, 2 Grade II, 1 Grade IIIA, 4 Grade IIIB). Union rate was 81.25% (26 cases). Nonunion rate was 18.75% (6 cases) and malunion 3.12% (1 case). Nonunion was higher in patients with open fractures (4). Compartment syndrome had been diagnosed in 6 cases (18.75%) with closed fracture and fasciotomy was performed when external fixator was applied. There were no deep infections. Pin tract infection was present in 7 cases (21.85%). CONCLUSION: Treatment of segmented tibial shaft fractures can be followed by a number of complications. Unilateral external fixation with convergent orientation of pins provides three-dimensional stability of the fracture and good biomechanical conditions for fracture healing, with lower complications rate.


Assuntos
Fixadores Externos , Fixação Intramedular de Fraturas/métodos , Fraturas da Tíbia/cirurgia , Adulto , Desenho de Equipamento , Feminino , Consolidação da Fratura , Humanos , Masculino , Complicações Pós-Operatórias/epidemiologia
12.
J Clin Orthop Trauma ; 10(1): 182-190, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30705557

RESUMO

BACKGROUND: The nonunion of open and closed tibial shaft fractures continues to be a common complication of fractures. Tibial nonunions constitute the majority of long bone nonunions seen by orthopaedic surgeons. In this article, we present our approach to the surgical treatment of noninfected tibial shaft nonunions. METHODS: Between 2008 and 2014, 33 patients with aseptic diaphyseal tibial nonunion was treated by reamed intramedullary nailing and were retrospectively reviewed. The initial fracture management consisted of external fixation (27 patients), plate fixation (2 patients) and cast treatment (4 patients). All patients, preoperatively, were evaluated for the signs of the infection, by the same protocol. There were 13 hypertrophic, 16 oligotrophic (atrophic) and 4 defect nonunions registered in our material. The primary goal was to perform a closed intramedullary nailing on antegrade manner. An open procedure was only unavoidable when implants had to be removed or an osteotomy had to be performed to improve the alignment. Functional rehabilitation was encouraged with the assistance of a physiotherapist early postoperative. Patients were examined regularly during followed-up for a minimum of 12 months period for clinical and radiological signs of union, infection, malunion, malalignment, limb shortening, and implant failure. RESULTS: The time that elapsed from injury to intramedullary nailing ranged from 9 months to 48 months (mean 17 months).Open intramedullary nailing was unavoidable in 25 cases (75,75%), while closed nailing was performed in 8 patients (24,25%). Osteotomy or resection of the fibula was performed in 78,8% of the cases. All patients were followed up in average period of 2 years postoperative (range 1-4 years), and 31(93,9%) patients achieved a solid union within the first 8 months. Mean union time was 5±0.8 months. Complications included 2 (6,06%) patients, one with deep infection and another case with absence of bone healing. Anatomical alignment has been achieved in the majority of patients, 28 patients (84,8%). The additionally autogenous bone chips were added in 4 patients (12,1%) where cortical defect was greater than 50% of the bone circumference. CONCLUSION: In conclusion, a reamed intramedullary nail provides optimal conditions for stable fixation, good rotational control, adequate alignment, early weight-bearing and a high union rate of tibial non-unions. Reaming of the medullary canal with preservation of periosteal sleeve create the "breeding ground" for sound healing of tibial shaft nonunions. Additionally cancellous bone grafting is recommended only in the case of defect nonunion.

13.
Med Glas (Zenica) ; 16(1): 88-92, 2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30589238

RESUMO

Aim To calculate stress and deformation under the force of pressure and bending in the dynamic compression plate (DCP), locking compression plate (LCP), selfdynamisable internal fixator (SIF) and locked intramedullary nail (LIN) in the models of juvidur, beef tibia bone (cadaver) and software of bone model simulator. Methods Juvidur and bone models were used for the experimental study, static tests were performed with SHIMADZU AGS-X tester. CATIA software was used to create a 3D model for the SCA simulator, while software ANSYS to calculate the tension and deformation for compressive and bending forces. Stress and deformation analysis was performed with the use of Finite Element Analysis (FEA). Results Weight coefficients of research methods were different (juvidur=0.3; cadaver=0.5; SCA Simuator=0.2), and weight coefficients of the force of pressure Kp =0.5 and bending forces in one plane K1 =0.25 and K2 =0.25 in another plane, the overall result on the dilatation of DCP, LCP, LIN and SIF on juvidur and veal cadaver models showed that the first ranking was the LIN with a rank coefficient KU-LIN = 0.0603, followed by the IFM with KU-IFM = 0.0621, DCP with KU-DCP = 0.0826 and LCP with KU-LCP = 0.2264. Conclusion Dilatation size did not exceed 0.2264 mm, hence the implants fulfilled biomechanical conditions for the internal stabilization of bone fractures. Prevalence goes to the locked intramedullar nailing and Mitkovic internal fixator in the treatment of diaphyseal, transversal, comminuted fractures in relation to DCP and LCP.


Assuntos
Materiais Biocompatíveis , Osso e Ossos , Fixação Interna de Fraturas/métodos , Fixação Intramedular de Fraturas/métodos , Fraturas Ósseas/terapia , Pressão , Estresse Mecânico , Animais , Fenômenos Biomecânicos , Pinos Ortopédicos , Placas Ósseas , Cadáver , Bovinos , Modelos Biológicos , Software , Tíbia
14.
Acta Inform Med ; 24(4): 261-265, 2016 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-27708489

RESUMO

INTRODUCTION: Artificial models can be useful at approximate and qualitative research, which should give the preliminary results. Artificial models are usually made of photo-elastic plastic e.g.. juvidur, araldite in the three-dimensional contour shape of the bone. Anatomical preparations consist of the same heterogeneous, structural materials with extremely anisotropic and unequal highly elastic characteristics, which are embedded in a complex organic structure. THE AIM OF THE STUDY: Examine the budget voltage and deformation of: dynamic compression plate (DCP), locking compression plate (LCP), Mitkovic internal fixator (MIF), Locked intramedullary nailing (LIN) on the compressive and bending forces on juvidur and veal bone models and compared the results of these two methods (juvidur, veal bone). MATERIAL AND METHODS: For the experimental study were used geometrically identical, anatomically shaped models of Juvidur and veal bones diameter of 30 mm and a length of 100 mm. Static tests were performed with SHIMADZU AGS-X testing machine, where the force of pressure (compression) increased from 0 N to 500 N, and then conducted relief. Bending forces grew from 0 N to 250 N, after which came into sharp relief. RESULTS: On models of juvidur and veal bones studies have confirmed that uniform stability at the site of the fracture MIF with a coefficient ranking KMIF=0,1971, KLIN=0,2704, KDCP=0,2727 i KLCP=0,5821. CONCLUSION: On models of juvidur and veal bones working with Shimadzu AGS-X testing machine is best demonstrated MIF with a coefficient of 0.1971.

15.
Vojnosanit Pregl ; 72(7): 576-82, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26364449

RESUMO

UNLABELLED: BACGROUND/AIM. Intertrochanteric fractures of the femur are the third most common fractures among all bone fractures. Today in everyday orthopedic practice a number of different methods of treatment of trochanteric fractures of the femur are applied. Despite the improvement in the development of new implants, the percentage of serious complications of the treatment of these fractures remains very high, varying from 10% to 20%. One of the most serious complications of internal fixation of intertrochanteric fractures is nonunion of fractures due to the lack of additional axial dynamisation of implants. The aim of this study was to determine the efficacy of double dynamisation in stable and unstable intertrochanteric fractures treatment using the self dynamisable internal fixator. METHODS: During the period from 2000 to 2009 we analyzed the use of selfdynamisable internal fixator (SIF implant) in the treatment of 247 patients with stable and unstable intertrochanteric fractures. Fracture types were classified according to the AO Fracture Classification/Orthopaedic Trauma Association Scheme. Salvati and Wilson scoring systems were used for functional assessment considering pain, walking ability and hip movements of operated patients. RESULTS: Of the total number of treated patients, 134 were males and 113 females, aged 19 to 90 (average 49.6) years. More than a half of the patients were older than 50 years. Monitoring of the patients after the operation was carried out clinically and radiographically for a period of three to six months in all the patients, whereas a 2-year follow-up was conducted in 176 (71.2%) patients. The average duration of surgery was 47 min, the average blood loss 145 mL, and the average fluoroscopy time was 16 sec (8-97 sec). The average time for union was 3.7 months (3-6.6 months). Double dynamisation (dynamisation along the neck and shaft of the femur) was observed in 85 (34.4%) patients, and was on average 4.3 mm (1.5-8 mm). All fractures managed with dynamisation implants healed completely within no later than six months after the surgery. In 17 cases there was a cut-out phenomenon of implant, while in seven cases there was mechanical implant failure. Complications were detected within 3 to 6 weeks after surgery, and treated by the method of intramedullary fixation. During the study, there were no cases of infection and thromboembolic complications detected. CONCLUSION: The concept of double dynamisation improves the fracture healing in the stable and unstable intertrochangeric fractures using the selfdynamisable internal fixator. This biological method of fixation provides healing of intertrochanteric fracture in the optimum period of time, significantly reducing the risk for mechanical failure.


Assuntos
Fixação Interna de Fraturas/instrumentação , Fraturas do Quadril/cirurgia , Fixadores Internos , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Avaliação da Deficiência , Desenho de Equipamento , Feminino , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Consolidação da Fratura , Fraturas do Quadril/diagnóstico , Fraturas do Quadril/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Dor Pós-Operatória/etiologia , Recuperação de Função Fisiológica , Fatores de Tempo , Resultado do Tratamento , Caminhada , Adulto Jovem
16.
Acta Chir Iugosl ; 61(1): 9-15, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25782218

RESUMO

INTRODUCTION: Pelvic trauma associated with urinary tract injury is a severe trauma, mostly caused by traffic accidents and falls from heights. These injuries require urgent treatment and close teamwork between urologic and orthopaedic surgeons. MATERIAL AND METHODS: In this retrospective study there were analyzed patients with pelvic trauma and extraperitoneal injury of urinary tract, treated surgically at Clinic for Ortopaedic Surgery and Traumatology and Urology Clinic in Clinical Center Nis. Surgical intervention in these patients had been realized as the synchronized work of both orthopaedic and urologic surgeons. The pelvis was treated by external and internal fixation. Mitkovic type external fixator was used for pelvic external fixation. Plating was used for pelvic internal fixation. Pelvic fractures were classified using Tile's classification system. The final functional results had been scored using Majeed score system. RESULTS: There were 42 patients with the injury of pelvic ring, treated at Clinic for Ortopaedic Surgery and Traumatology and at Urology Clinic, Clinical Center Nis, in the period of 01.01.2011. to 31.12.2013, 30 males and 12 females, with average age of 53.69 (19-84) years old. In 80% of cases pelvic fractures were caused by high energy trauma in traffic accidents. According to Tile's classification, 9 patients (21,42%) had pelvic fracture type A, 23 patients (54,46%) had pelvic fracture type B and 10 patients (23,80%) had pelvic fracture type C. Urinary tract injury was diagnosed in 9 patients (21,42%): 5 patients (11,9%) with bladder injury, 3 patients (7,14%) with posterior urethra injury and 1 patient (2,38%) with both bladder and posterior urethra injury. CONCLUSION: Urgent repair of extraperitoneal urinary tract injury by urologic surgeons and synchronized pelvic reduction and fixation using external or internal fixation by ortopaedic surgeon, in the same surgical procedure, is the standard method for treatment of this severe injury.


Assuntos
Fixação de Fratura/métodos , Fraturas Ósseas , Ossos Pélvicos , Sistema Urinário , Procedimentos Cirúrgicos Urológicos/métodos , Acidentes de Trânsito , Feminino , Fraturas Ósseas/etiologia , Fraturas Ósseas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Equipe de Assistência ao Paciente , Ossos Pélvicos/lesões , Ossos Pélvicos/cirurgia , Estudos Retrospectivos , Índices de Gravidade do Trauma , Sistema Urinário/lesões , Sistema Urinário/cirurgia
17.
Srp Arh Celok Lek ; 142(1-2): 40-7, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24684030

RESUMO

INTRODUCTION: Correct choice of osteosynthesis method is a very important factor in providing the optimal conditions for appropriate healing of the fracture. There are still disagreements about the method of stabilization of some long bone fractures. Critically observed, no method of fracture fixation is ideal. Each osteosynthesis method has both advantages and weaknesses. OBJECTIVE: The objective of this study was to compare the results of the experimental application of three different internal fixation methods: plate fixation, intramedullary nail fixation and self-dynamisable internal fixator (SIF). METHODS: A series of 30 animals were used (Lepus cuniculus) as experimental animals, divided into three groups of ten animals each. Femoral diaphysis of each animal was osteotomized and fixed with one of three implants. Ten weeks later all animals were sacrificed and each specimen underwent histological and biomechanical testing. RESULTS: Histology showed that the healing process with SIF was more complete and bone callus was more mature in comparison to other two methods. During biomechanical investigation (computerized bending stress test), it was documented with high statistical significance that using SIF led to stronger healing ten weeks after the operation. CONCLUSION: According to the results obtained in this study, it can be concluded that SIF is a suitable method for fracture treatment.


Assuntos
Placas Ósseas , Calo Ósseo/patologia , Fêmur/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Cicatrização , Animais , Fenômenos Biomecânicos , Calo Ósseo/fisiopatologia , Fêmur/patologia , Fêmur/fisiopatologia , Fraturas Ósseas/patologia , Fraturas Ósseas/fisiopatologia , Coelhos
18.
Acta Chir Iugosl ; 60(2): 33-9, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24298736

RESUMO

INTRODUCTION: Tibial fractures accompanied by radius fractures at typical sites are the most common type of fractures. OBJECTIVE: The study is aimed at using the examined sample to make an efficient and economically acceptable choice in the treatment of tibial diaphyseal fractures. MATERIAL AND METHODS: The series comprises a retrospective and prospective study of the treatment of 131 fresh tibial fractures: 31 in women (23.66%) and 100 in men (76.34%) of the average age of 37.89. Nineteen patients (14.50%) were treated conservatively and 112 (85.50%) surgically: 22 (16.79%) with anti-rotation intramedullary nails, 74 (56.49%) with Mitkovic external fixator type M20, and 16 (12.21%) with locking compression plate. General anaesthesia was used in 46 patients (35.11%), while spinal anaesthesia was used in 85 of them (64.89%). RESULTS: According to the Karlstrom-Olerud scoring system, the treatment results were as follows: for the 22 tibiae treated with anti-rotation intramedullary nails: in 15 (68.18%) the results were excellent, in 3 (13.64%) they were good and in 4 (18.18%) they were poor. As for the results for the 74 tibiae treated with Mitkovic external fixator type M20, they were as follows: in 62 (83.78%) excellent, in 9 (12.16%) good, and in 3 (4.05%) they were poor. The results for the 16 patients treated with locking compression plate were excellent in 10 (62.50%), good in 2 (12.50%) and poor in 4 patients (25.00%). The treatment results for the 19 tibiae treated with plaster cast were excellent in 12 patients (63.16%), good in 2 (10.53%) and poor in 5 (26.32%). The definite results for the 131 fractured tibiae treated with the aforementioned techniques were as follows: excellent in 99 (75.57%), good in 17 (12.98%) and poor in 15 patients (11.45%). DISCUSSION: There is a variety of controversial positions concerning the treatment of the tibial diaphysis. CONCLUSION: On the basis of the results of surgical treatment for the given series, the number of surgical interventions, the price of osteosynthetic material, my preferences in treating tibial diaphyseal fractures would be as follows: Mitkovic external fixator type M20, anti-rotation intramedullary nails and locking compression plate. Conservative treatment is indicated when the X-ray examination confirms that the fragments have a position acceptable for conservative treatment with plaster cast.


Assuntos
Fixadores Externos , Fixação Intramedular de Fraturas , Fraturas da Tíbia/cirurgia , Adulto , Pinos Ortopédicos , Placas Ósseas , Moldes Cirúrgicos , Diáfises/lesões , Feminino , Fixação Intramedular de Fraturas/efeitos adversos , Fixação Intramedular de Fraturas/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Fraturas da Tíbia/terapia , Resultado do Tratamento , Adulto Jovem
19.
Acta Chir Iugosl ; 60(2): 71-9, 2013.
Artigo em Sr | MEDLINE | ID: mdl-24298742

RESUMO

INTRODUCTION: Femoral neck fractures are one of the most common fractures primarily the elderly, coupled with a high degree of morbidity and mortality. The treatment is applied a number of methods of internal fixation (multiple cannulated screws available, DHS system, cefalomedullary). At the Department of Orthopedics and Traumatology of Nis developed a new method of fixation of femoral neck fracture, which allows stable fixation of dislocated and nondislocated femoral neck fracture. Self-tapping antirotation fixation (SAF) using two cannulated screws to initial compression fractures intraoperative and postoperative dynamic linear compression of the fracture with early full support to the patient. MATERIAL AND METHODS: In the period between 2008 to 2012, 53 patients treated for femoral neck fracture in the Clinic for orthopedic and traumatology, Clinical center in Nis, Serbia, by SAF (the self-tapping cannulated screws antirotation; ORTOKON doo Nis). All patients were followed up after surgery in a minimum period of 13 weeks (13-106 weeks). The outcome was evaluated on the basis of clinical and radiological signs of fracture healing and the Harris hip score of functional recovery of the patient. RESULTS: Of the total number of patients (53) treated with this method of fixation, 31 of them were females and 22 males, mean age 52.7 years (28-75 years). The average time of surgery was 36.4 minutes (19-70 minutes). During the postoperative follow-up of all patients (53) operated by this method, six patients were lost in the further postoperative monitoring, so that 47 patients remained for final evaluation. The total incidence of nonunion of femoral neck fracture after surgery this method was 6.4% (three patients). Shortening of the femoral neck after fixation by this method was recorded in 27 cases, and what amounted to an average of 2.8 mm (1, 2 mm in nondislocated to 4.55 with dislocated fracture) and did not affect the functional outcome. During radiographic follow-up was not detected fracture implants. CONCLUSION: Self-tapping screws cannulated antirotation (SAF method) represent a reliable method of fixation of dislocated and nondislocated femoral neck fracture. The main prerequisite for the proper healing of femoral neck fractures with this method is that anatomical fracture reduction is achieved by a closed or open method. This way of fixation allows the early full weight bearing patient operated limb and faster postoperative functional recovery of the fracture healing in optimal time.


Assuntos
Parafusos Ósseos , Fraturas do Colo Femoral/cirurgia , Fixação Interna de Fraturas/métodos , Adulto , Idoso , Feminino , Seguimentos , Fixação Interna de Fraturas/instrumentação , Consolidação da Fratura , Fraturas não Consolidadas/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica
20.
Acta Chir Iugosl ; 60(2): 53-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24298739

RESUMO

Rotationally and vertically unstable injuries to the pelvic ring (Type C) require stabilisation of the anterior and posterior pelvic ring complex. Inadequate treatment of these injuries leads to chronic instability of the pelvic ring, which can finally cause permanent disability. Open reduction and stable internal fixation of the anterior and posterior complex of unstable pelvic ring injuries are standard procedures in the treatment of hemodynamically stable patients with (Type C) pelvic injuries. Our aim is to show that this type of treatment achieves excellent and good results. All patients were operated on using the method of open reduction and anterior plate fixation of sacroiliac complex as well as fixation of the pubic symphisis. We present a retrospective study of the results concerning the treatment of 19 patients with (Type C) unstable pelvic injuries. The average age of the patients was 43,21 years old. The final functional results, 2 years post-surgery according to the Majeed scoring system and the results were excellent in 11 (57.89%) and good in 8 (42.1%) patients. There were no bad results to report. Type C pelvic ring injuries are unstable and unless they are adequately treated, they can lead to permanent consequences. Surgical treatment that includes open reduction and stable internal fixation of the anterior and posterior pelvic ring complex leads to excellent and good results. The patients that were treated surgically by fixation of the anterior and posterior pelvic ring complex return to their everyday lives and work activities.