Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Nanotechnology ; 28(2): 025704, 2017 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-27922833

RESUMO

Multicomponent nano-agents were designed and built via a core-shell approach to enhance their surface enhanced Raman scattering (SERS) signals. These nano-agents had 36 nm × 12 nm gold nanorod cores coated by 4 nm thick silver shell films and a subsequent thin bifunctional thiolated polyethylene glycol (HS-PEG-COOH) layer. Ambient time-lapsed SERS signal measurements of these functionalized nanorods taken over a two-week period indicated no signal degradation, suggesting that large portions of the silver shells remained in pure metallic form. The morphology of the nanorods was characterized by transmission electron microscopy (TEM) and ultra-high resolution scanning TEM. X-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES) were utilized to assess the oxidation states of the silver shells covered by HS-PEG-COOH. The binding energies of Ag 3d XPS spectra yielded very small chemical shifts with oxidation; however, the AES peak shapes gave meaningful information about the extent of oxidation undergone by the nano-agent. While the silver shells without HS-PEG-COOH coatings oxidized significantly, the silver shells with HS-PEG-COOH remained predominantly metallic. In fact, six month-old samples still retained mostly metallic silver shells. These findings further demonstrate the stability and longevity of the nanostructures, indicating their significant potential as plasmonically active agents for highly sensitive detection in various biological systems, including cancer cells, tissues, or even organisms.

2.
Materials (Basel) ; 16(2)2023 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-36676269

RESUMO

In this study, pure titanium equivalent to Grade 1 was subjected to tensile tests at strain rates ranging from 10-6 to 100 s-1 to investigate the relationship between its mechanical properties and its twinning and slip. Deformation properties and microstructures of samples having average grain sizes of 210 µm (Ti-210), 30 µm (Ti-30), and 5 µm (Ti-5) were evaluated. With increasing strain rates, the 0.2% proof stress and ultimate tensile strength increased for all samples; the fracture strain increased for Ti-210, decreased for Ti-5, and changed negligibly for Ti-30. Comparing high (100 s-1) and low (10-6 s-1) strain rates, twinning occurred more frequently in Ti-30 and Ti-210 at high strain rates, but the frequency did not change in Ti-5. The frequency of 1st order pyramidal slip tended to be higher in Ti-30 and Ti-5 at low strain rates. The higher ductility exhibited by Ti-210 at high strain rates was attributed to the high frequency of twinning. In contrast, the higher ductility of Ti-5 at low strain rates was attributed to the activity of the 1st order pyramidal slip.

3.
Nat Commun ; 14(1): 404, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36725856

RESUMO

Interstitial oxygen embrittles titanium, particularly at cryogenic temperatures, which necessitates a stringent control of oxygen content in fabricating titanium and its alloys. Here, we propose a structural strategy, via grain refinement, to alleviate this problem. Compared to a coarse-grained counterpart that is extremely brittle at 77 K, the uniform elongation of an ultrafine-grained (UFG) microstructure (grain size ~ 2.0 µm) in Ti-0.3wt.%O is successfully increased by an order of magnitude, maintaining an ultrahigh yield strength inherent to the UFG microstructure. This unique strength-ductility synergy in UFG Ti-0.3wt.%O is achieved via the combined effects of diluted grain boundary segregation of oxygen that helps to improve the grain boundary cohesive energy and enhanced dislocation activities that contribute to the excellent strain hardening ability. The present strategy will not only boost the potential applications of high strength Ti-O alloys at low temperatures, but can also be applied to other alloy systems, where interstitial solution hardening results into an undesirable loss of ductility.

4.
Microsc Microanal ; 17(6): 983-90, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22030303

RESUMO

Focused ion beam (FIB) induced damage in nanocrystalline Al thin films has been characterized using advanced transmission electron microscopy techniques. Electron tomography was used to analyze the three-dimensional distribution of point defect clusters induced by FIB milling, as well as their interaction with preexisting dislocations generated by internal stresses in the Al films. The atomic structure of interstitial Frank loops induced by irradiation, as well as the core structure of Frank dislocations, has been resolved with aberration-corrected high-resolution annular dark-field scanning TEM. The combination of both techniques constitutes a powerful tool for the study of the intrinsic structural properties of point defect clusters as well as the interaction of these defects with preexisting or deformation dislocations in irradiated bulk or nanostructured materials.


Assuntos
Alumínio/análise , Microscopia Eletrônica de Varredura/métodos , Microscopia Eletrônica de Transmissão/métodos , Nanoestruturas/análise , Nanotecnologia/métodos , Tomografia Computadorizada por Raios X/métodos , Cristalização , Íons , Micromanipulação , Dióxido de Silício/química , Tomografia Computadorizada por Raios X/instrumentação
5.
Microscopy (Oxf) ; 70(3): 265-277, 2021 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-33002113

RESUMO

In this study, we conducted a quantitative evaluation of dislocation density by scanning electron microscopy electron channeling contrast imaging for α grains of a Ti-6Al-4V alloy deformed at room temperature. The depth of visibility of dislocations is experimentally measured as 140 to 160 nm by a serial sectioning observation. This result is compared with the theoretical value and applied to evaluate dislocation density. These factors confirm that the theoretically calculated value of the depth of visibility, at 5 to 6 times the extinction distance, is valid for the hexagonal close-packed Ti alloy.

6.
Sci Rep ; 11(1): 20720, 2021 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-34702955

RESUMO

Scanning transmission electron microscopy (STEM) is suitable for visualizing the inside of a relatively thick specimen than the conventional transmission electron microscopy, whose resolution is limited by the chromatic aberration of image forming lenses, and thus, the STEM mode has been employed frequently for computed electron tomography based three-dimensional (3D) structural characterization and combined with analytical methods such as annular dark field imaging or spectroscopies. However, the image quality of STEM is severely suffered by noise or artifacts especially when rapid imaging, in the order of millisecond per frame or faster, is pursued. Here we demonstrate a deep-learning-assisted rapid STEM tomography, which visualizes 3D dislocation arrangement only within five-second acquisition of all the tilt-series images even in a 300 nm thick steel specimen. The developed method offers a new platform for various in situ or operando 3D microanalyses in which dealing with relatively thick specimens or covering media like liquid cells are required.

7.
Microscopy (Oxf) ; 69(3): 141-155, 2020 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-32115659

RESUMO

Transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) enable the visualization of three-dimensional (3D) microstructures ranging from atomic to micrometer scales using 3D reconstruction techniques based on computed tomography algorithms. This 3D microscopy method is called electron tomography (ET) and has been utilized in the fields of materials science and engineering for more than two decades. Although atomic resolution is one of the current topics in ET research, the development and deployment of intermediate-resolution (non-atomic-resolution) ET imaging methods have garnered considerable attention from researchers. This research trend is probably not irrelevant due to the fact that the spatial resolution and functionality of 3D imaging methods of scanning electron microscopy (SEM) and X-ray microscopy have come to overlap with those of ET. In other words, there may be multiple ways to carry out 3D visualization using different microscopy methods for nanometer-scale objects in materials. From the above standpoint, this review paper aims to (i) describe the current status and issues of intermediate-resolution ET with regard to enhancing the effectiveness of TEM/STEM imaging and (ii) discuss promising applications of state-of-the-art intermediate-resolution ET for materials research with a particular focus on diffraction contrast ET for crystalline microstructures (superlattice domains and dislocations) including a demonstration of in situ dislocation tomography.

8.
ACS Nano ; 12(6): 6236-6244, 2018 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-29863847

RESUMO

Multilayer hexagonal boron nitride (h-BN) is an ideal insulator for two-dimensional (2D) materials, such as graphene and transition metal dichalcogenides, because h-BN screens out influences from surroundings, allowing one to observe intrinsic physical properties of the 2D materials. However, the synthesis of large and uniform multilayer h-BN is still very challenging because it is difficult to control the segregation process of B and N atoms from metal catalysts during chemical vapor deposition (CVD) growth. Here, we demonstrate CVD growth of multilayer h-BN with high uniformity by using the Ni-Fe alloy film and borazine (B3H6N3) as catalyst and precursor, respectively. Combining Ni and Fe metals tunes the solubilities of B and N atoms and, at the same time, allows one to engineer the metal crystallinity, which stimulates the uniform segregation of multilayer h-BN. Furthermore, we demonstrate that triangular WS2 grains grown on the h-BN show photoluminescence stronger than that grown on a bare SiO2 substrate. The PL line width of WS2/h-BN (the minimum and mean widths are 24 and 43 meV, respectively) is much narrower than those of WS2/SiO2 (44 and 67 meV), indicating the effectiveness of our CVD-grown multilayer h-BN as an insulating layer. Large-area, multilayer h-BN realized in this work will provide an excellent platform for developing practical applications of 2D materials.

9.
Ultramicroscopy ; 159 Pt 1: 26-33, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26255118

RESUMO

In this paper we introduce an approach for precise orientation mapping of crystalline specimens by means of transmission electron microscopy. We show that local orientation values can be reconstructed from experimental dark-field image data acquired at different specimen tilts and multiple Bragg reflections. By using the suggested method it is also possible to determine the orientation of the tilt axis with respect to the image or diffraction pattern. The method has been implemented to automatically acquire the necessary data and then map crystal orientation for a given region of interest. We have applied this technique to a specimen prepared from a Ni-based super-alloy CMSX-4. The functionality and limitations of our method are discussed and compared to those of other techniques available.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA