Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Ann Neurol ; 91(1): 89-100, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34687063

RESUMO

OBJECTIVE: The purpose of this study was to investigate the effect of disease modifying therapies on immune response to severe acute respiratory syndrome-coronavirus 2 (SARS-CoV-2) vaccines in people with multiple sclerosis (MS). METHODS: Four hundred seventy-three people with MS provided one or more dried blood spot samples. Information about coronavirus disease 2019 (COVID-19) and vaccine history, medical, and drug history were extracted from questionnaires and medical records. Dried blood spots were eluted and tested for antibodies to SARS-CoV-2. Antibody titers were partitioned into tertiles with people on no disease modifying therapy as a reference. We calculated the odds ratio of seroconversion (univariate logistic regression) and compared quantitative vaccine response (Kruskal Wallis) following the SARS-CoV-2 vaccine according to disease modifying therapy. We used regression modeling to explore the effect of vaccine timing, treatment duration, age, vaccine type, and lymphocyte count on vaccine response. RESULTS: Compared to no disease modifying therapy, the use of anti-CD20 monoclonal antibodies (odds ratio = 0.03, 95% confidence interval [CI] = 0.01-0.06, p < 0.001) and fingolimod (odds ratio = 0.04; 95% CI = 0.01-0.12) were associated with lower seroconversion following the SARS-CoV-2 vaccine. All other drugs did not differ significantly from the untreated cohort. Both time since last anti-CD20 treatment and total time on treatment were significantly associated with the response to the vaccination. The vaccine type significantly predicted seroconversion, but not in those on anti-CD20 medications. Preliminary data on cellular T-cell immunity showed 40% of seronegative subjects had measurable anti-SARS-CoV-2 T cell responses. INTERPRETATION: Some disease modifying therapies convey risk of attenuated serological response to SARS-CoV-2 vaccination in people with MS. We provide recommendations for the practical management of this patient group. ANN NEUROL 20219999:n/a-n/a.


Assuntos
Antirreumáticos/uso terapêutico , Vacinas contra COVID-19/imunologia , COVID-19/prevenção & controle , Hospedeiro Imunocomprometido , Esclerose Múltipla/imunologia , Soroconversão/efeitos dos fármacos , Adulto , Anticorpos Antivirais/sangue , Anticorpos Antivirais/efeitos dos fármacos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/tratamento farmacológico , SARS-CoV-2 , Reino Unido
2.
Mult Scler ; 29(8): 979-989, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37431627

RESUMO

BACKGROUND: People with multiple sclerosis (pwMS) treated with certain disease-modifying therapies (DMTs) have attenuated IgG response following COVID-19 vaccination; however, the clinical consequences remain unclear. OBJECTIVE: To report COVID-19 rates in pwMS according to vaccine serology. METHODS: PwMS with available (1) serology 2-12 weeks following COVID-19 vaccine 2 and/or vaccine 3 and (2) clinical data on COVID-19 infection/hospitalisation were included. Logistic regression was performed to examine whether seroconversion following vaccination predicted risk of subsequent COVID-19 infection after adjusting for potential confounders. Rates of severe COVID-19 (requiring hospitalisation) were also calculated. RESULTS: A total of 647 pwMS were included (mean age 48 years, 500 (77%) female, median Expanded Disability Status Scale (EDSS) 3.5% and 524 (81%) exposed to DMT at the time of vaccine 1). Overall, 472 out of 588 (73%) were seropositive after vaccines 1 and 2 and 222 out of 305 (73%) after vaccine 3. Seronegative status after vaccine 2 was associated with significantly higher odds of subsequent COVID-19 infection (odds ratio (OR): 2.35, 95% confidence interval (CI): 1.34-4.12, p = 0.0029), whereas seronegative status after vaccine 3 was not (OR: 1.05, 95% CI: 0.57-1.91). Five people (0.8%) experienced severe COVID-19, all of whom were seronegative after most recent vaccination. CONCLUSION: Attenuated humoral response to initial COVID-19 vaccination predicts increased risk of COVID-19 in pwMS, but overall low rates of severe COVID-19 were seen.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Esclerose Múltipla , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , COVID-19/epidemiologia , COVID-19/prevenção & controle , Vacinas contra COVID-19/efeitos adversos , Hospitalização , Esclerose Múltipla/tratamento farmacológico , Esclerose Múltipla/epidemiologia , Vacinação
3.
Clin Chem ; 68(8): 1075-1083, 2022 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-35699503

RESUMO

BACKGROUND: Newborn screening (NBS) laboratories in the United Kingdom adhere to common protocols based on single analyte cutoff values (COVs); therefore, interlaboratory harmonization is of paramount importance. Interlaboratory variation for screening analytes in UK NBS laboratories ranges from 17% to 59%. While using common stable isotope internal standards has been shown to significantly reduce interlaboratory variation, instrument set-up, sample extraction, and calibration approach are also key factors. METHODS: Dried blood spot (DBS) extraction processes, instrument set-up, mobile-phase composition, sample introduction technique, and calibration approach of flow injection analysis-tandem mass spectrometry (FIA-MS/MS) methods were optimized. Inter- and intralaboratory variation of methionine, leucine, phenylalanine, tyrosine, isovaleryl-carnitine, glutaryl-carnitine, octanoyl-carnitine, and decanoyl-carnitine were determined pre- and postoptimization, using 3 different calibration approaches. RESULTS: Optimal recovery of analytes from DBS was achieved with a 35-min extraction time and 80% methanol (150 µL). Optimized methodology decreased the mean intralaboratory percentage relative SD (%RSD) for the 8 analytes from 20.7% (range 4.1-46.0) to 5.4% (range 3.0-8.5). The alternative calibration approach reduced the mean interlaboratory %RSD for all analytes from 16.8% (range 4.1-25.0) to 7.1% (range 4.1-11.0). Nuclear magnetic resonance analysis of the calibration material highlighted the need for standardization. The purities of isovaleryl-carnitine and glutaryl-carnitine were 85.13% and 69.94% respectively, below the manufacturer's stated values of ≥98%. CONCLUSIONS: For NBS programs provided by multiple laboratories using single analyte COVs, harmonization and standardization of results can be achieved by optimizing legacy FIA-MS/MS methods, adopting a common analytical protocol, and using standardized calibration material rather than internal calibration.


Assuntos
Análise de Injeção de Fluxo , Espectrometria de Massas em Tandem , Calibragem , Carnitina , Análise de Injeção de Fluxo/métodos , Humanos , Recém-Nascido , Triagem Neonatal/métodos , Padrões de Referência , Espectrometria de Massas em Tandem/métodos
4.
J Inherit Metab Dis ; 45(4): 819-831, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35403730

RESUMO

Mitochondrial trifunctional protein (MTP) is involved in long-chain fatty acid ß-oxidation (lcFAO). Deficiency of one or more of the enzyme activities as catalyzed by MTP causes generalized MTP deficiency (MTPD), long-chain hydroxyacyl-CoA dehydrogenase deficiency (LCHADD), or long-chain ketoacyl-CoA thiolase deficiency (LCKATD). When genetic variants result in thermo-sensitive enzymes, increased body temperature (e.g. fever) can reduce enzyme activity and be a risk factor for clinical decompensation. This is the first description of five patients with a thermo-sensitive MTP deficiency. Clinical and genetic information was obtained from clinical files. Measurement of LCHAD and LCKAT activities, lcFAO-flux studies and palmitate loading tests were performed in skin fibroblasts cultured at 37°C and 40°C. In all patients (four MTPD, one LCKATD), disease manifested during childhood (manifestation age: 2-10 years) with myopathic symptoms triggered by fever or exercise. In four patients, signs of retinopathy or neuropathy were present. Plasma long-chain acylcarnitines were normal or slightly increased. HADHB variants were identified (at age: 6-18 years) by whole exome sequencing or gene panel analyses. At 37°C, LCHAD and LCKAT activities were mildly impaired and lcFAO-fluxes were normal. Remarkably, enzyme activities and lcFAO-fluxes were markedly diminished at 40°C. Preventive (dietary) measures improved symptoms for most. In conclusion, all patients with thermo-sensitive MTP deficiency had a long diagnostic trajectory and both genetic and enzymatic testing were required for diagnosis. The frequent absence of characteristic acylcarnitine abnormalities poses a risk for a diagnostic delay. Given the positive treatment effects, upfront genetic screening may be beneficial to enhance early recognition.


Assuntos
Erros Inatos do Metabolismo Lipídico , Miopatias Mitocondriais , Doenças Musculares , 3-Hidroxiacil-CoA Desidrogenases , Adolescente , Cardiomiopatias , Criança , Pré-Escolar , Coenzima A , Diagnóstico Tardio , Ácidos Graxos/metabolismo , Humanos , Erros Inatos do Metabolismo Lipídico/diagnóstico , Erros Inatos do Metabolismo Lipídico/genética , Erros Inatos do Metabolismo Lipídico/metabolismo , Miopatias Mitocondriais/diagnóstico , Miopatias Mitocondriais/genética , Proteína Mitocondrial Trifuncional/deficiência , Doenças Musculares/diagnóstico , Doenças Musculares/genética , Doenças do Sistema Nervoso , Rabdomiólise
5.
J Nutr ; 151(12): 3738-3745, 2021 12 03.
Artigo em Inglês | MEDLINE | ID: mdl-34510193

RESUMO

BACKGROUND: Individuals with low serum vitamin B-12 and high serum folate have higher plasma concentrations of methylmalonic acid (MMA). Whether folic acid (FA) causes an increase in MMA is not known. OBJECTIVES: We aimed to determine the impact of FA supplementation on plasma MMA concentration in people with low or marginal serum vitamin B-12. METHODS: We conducted a multicenter double-blind placebo-controlled randomized trial of oral FA (5 mg/d for 12 wk) in middle-aged patients treated with antidepressant medication participating in the FoLATED (Folate Augmentation of Treatment-Evaluation for Depression) trial. Participants defined as having "low" serum vitamin B-12 (vitamin B-12 ≥150 and <220 ng/L) or "marginal" serum vitamin B-12 (vitamin B-12 ≥ 220 and <280 ng/L) were included. The primary outcome of this substudy was MMA at week 12. A mixed-effects linear regression was fitted and reported using the adjusted mean difference (aMD). RESULTS: A total of 177 participants were included (85 randomly assigned to placebo and 92 to FA); the mean ± SD age was 46.2 ± 11.8 y, and 112 (63.3%) were female. The MMA analysis included 135 participants and the aMD was -0.01 (95% CI: -0.06, 0.04; P = 0.71). Serum folate was measured on 166 participants and increased in the supplementation group; the aMD was 21.6 µg/L (95% CI: 8.13, 25.02 µg/L; P < 0.001). A total of 117 participants were assessed for RBC folate, which also increased in the supplementation group; the aMD was 461 µg/L (95% CI: 387, 535 µg/L; P < 0.001). CONCLUSIONS: Supplementation of FA leads to an increase of serum and RBC folate, but does not change plasma MMA concentration in individuals with serum vitamin B-12 between 150 and 280 ng/L. We cannot exclude effects in older people or those with serum vitamin B-12 <150 ng/L. Previously reported associations may arise from effects of impaired vitamin B-12 status on folate metabolism.This trial was registered at www.isrctn.com as ISRCTN37558856.


Assuntos
Ácido Metilmalônico , Vitamina B 12 , Idoso , Suplementos Nutricionais , Feminino , Ácido Fólico , Homocisteína , Humanos , Pessoa de Meia-Idade , Vitaminas
6.
J Inherit Metab Dis ; 43(2): 179-188, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31433494

RESUMO

Analysis of blood phenylalanine is central to the monitoring of patients with phenylketonuria (PKU) and age-related phenylalanine target treatment-ranges (0-12 years; 120-360 µmol/L, and >12 years; 120-600 µmol/L) are recommended in order to prevent adverse neurological outcomes. These target treatment-ranges are based upon plasma phenylalanine concentrations. However, patients are routinely monitored using dried bloodspot (DBS) specimens due to the convenience of collection. Significant differences exist between phenylalanine concentrations in plasma and DBS, with phenylalanine concentrations in DBS specimens analyzed by flow-injection analysis tandem mass spectrometry reported to be 18% to 28% lower than paired plasma concentrations analyzed using ion-exchange chromatography. DBS specimens with phenylalanine concentrations of 360 and 600 µmol/L, at the critical upper-target treatment-range thresholds would be plasma equivalents of 461 and 768 µmol/L, respectively, when a reported difference of 28% is taken into account. Furthermore, analytical test imprecision and bias in conjunction with pre-analytical factors such as volume and quality of blood applied to filter paper collection devices to produce DBS specimens affect the final test results. Reporting of inaccurate patient results when comparing DBS results to target treatment-ranges based on plasma concentrations, together with inter-laboratory imprecision could have a significant impact on patient management resulting in inappropriate dietary change and potentially adverse patient outcomes. This review is intended to provide perspective on the issues related to the measurement of phenylalanine in blood specimens and to provide direction for the future needs of PKU patients to ensure reliable monitoring of metabolic control using the target treatment-ranges.


Assuntos
Teste em Amostras de Sangue Seco/métodos , Fenilalanina/sangue , Fenilcetonúrias/sangue , Aminoácidos/sangue , Cromatografia Líquida de Alta Pressão/métodos , Teste em Amostras de Sangue Seco/instrumentação , Humanos , Espectrometria de Massas em Tandem/métodos
7.
J Inherit Metab Dis ; 42(1): 128-139, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30740731

RESUMO

PURPOSE: To assess how the current practice of newborn screening (NBS) for homocystinurias compares with published recommendations. METHODS: Twenty-two of 32 NBS programmes from 18 countries screened for at least one form of homocystinuria. Centres provided pseudonymised NBS data from patients with cystathionine beta-synthase deficiency (CBSD, n = 19), methionine adenosyltransferase I/III deficiency (MATI/IIID, n = 28), combined remethylation disorder (cRMD, n = 56) and isolated remethylation disorder (iRMD), including methylenetetrahydrofolate reductase deficiency (MTHFRD) (n = 8). Markers and decision limits were converted to multiples of the median (MoM) to allow comparison between centres. RESULTS: NBS programmes, algorithms and decision limits varied considerably. Only nine centres used the recommended second-tier marker total homocysteine (tHcy). The median decision limits of all centres were ≥ 2.35 for high and ≤ 0.44 MoM for low methionine, ≥ 1.95 for high and ≤ 0.47 MoM for low methionine/phenylalanine, ≥ 2.54 for high propionylcarnitine and ≥ 2.78 MoM for propionylcarnitine/acetylcarnitine. These decision limits alone had a 100%, 100%, 86% and 84% sensitivity for the detection of CBSD, MATI/IIID, iRMD and cRMD, respectively, but failed to detect six individuals with cRMD. To enhance sensitivity and decrease second-tier testing costs, we further adapted these decision limits using the data of 15 000 healthy newborns. CONCLUSIONS: Due to the favorable outcome of early treated patients, NBS for homocystinurias is recommended. To improve NBS, decision limits should be revised considering the population median. Relevant markers should be combined; use of the postanalytical tools offered by the CLIR project (Collaborative Laboratory Integrated Reports, which considers, for example, birth weight and gestational age) is recommended. tHcy and methylmalonic acid should be implemented as second-tier markers.


Assuntos
Homocistinúria/diagnóstico , Acetilcarnitina/metabolismo , Erros Inatos do Metabolismo dos Aminoácidos/diagnóstico , Erros Inatos do Metabolismo dos Aminoácidos/metabolismo , Carnitina/análogos & derivados , Carnitina/metabolismo , Feminino , Glicina N-Metiltransferase/deficiência , Glicina N-Metiltransferase/metabolismo , Homocisteína/metabolismo , Homocistinúria/metabolismo , Humanos , Recém-Nascido , Masculino , Metionina/metabolismo , Metilenotetra-Hidrofolato Redutase (NADPH2)/deficiência , Metilenotetra-Hidrofolato Redutase (NADPH2)/metabolismo , Ácido Metilmalônico/metabolismo , Espasticidade Muscular/diagnóstico , Espasticidade Muscular/metabolismo , Triagem Neonatal/métodos , Fenilalanina/metabolismo , Transtornos Psicóticos/diagnóstico , Transtornos Psicóticos/metabolismo
8.
Clin Chem ; 63(4): 908-914, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28209627

RESUMO

BACKGROUND: Duchenne muscular dystrophy (DMD) is a progressive, lethal X-linked neuromuscular disorder with an average worldwide incidence of 1:5000. Blood spot creatine kinase (CK) enzyme assays previously used in newborn screening programs for DMD are nonspecific because measured CK enzyme activity is attributable to 3 isoenzyme forms of CK (CK-MM, CK-MB, and CK-BB) and it is the CK-MM isoform that is found predominantly in skeletal muscle. CK-MM is increased in boys with DMD owing to muscle damage. We describe a sensitive and specific automated immunoassay for CK-MM to screen for DMD in blood spots. METHODS: The prototype assay was developed on the PerkinElmer GSP® analyzer to enable high-throughput screening. CK-MM was assayed using a solid phase, 2-site immunofluorometric system. Purified human CK-MM was used to create calibrators and controls. RESULTS: The limit of blank (LOB), detection (LOD), and quantification (LOQ) values were <1, 3, and 8 ng/mL, respectively. The analytical measurement range was 4-8840 ng/mL. Interassay (n = 40) imprecision was <7% across the analytical range. Cross-reactivity was <5% for CK-MB and 0% for CK-BB. The mean recovery of CK-MM was 101% (range 87%-111%). Blood spots from newborn infants (n = 277) had a mean CK-MM concentration of 155 ng/mL and a 99th centile of 563 ng/mL. The mean blood spot CK-MM concentration from 10 cases of DMD was 5458 ng/mL (range 1217-9917 ng/mL). CONCLUSIONS: CK-MM can be reliably quantified in blood spots. The development of this CK-MM assay on a commercial immunoassay analyzer would enable standardized and high-throughput newborn blood spot screening of DMD.


Assuntos
Creatina Quinase/sangue , Ensaios de Triagem em Larga Escala , Imunoensaio , Músculo Esquelético/enzimologia , Distrofia Muscular de Duchenne/diagnóstico , Adulto , Creatina Quinase/metabolismo , Feminino , Humanos , Lactente , Recém-Nascido , Isoenzimas/sangue , Isoenzimas/metabolismo , Masculino , Pessoa de Meia-Idade , Distrofia Muscular de Duchenne/sangue
9.
Clin Chem ; 62(3): 466-75, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26647314

RESUMO

BACKGROUND: The analysis of dried blood spots has been used routinely for newborn screening since the early 1970s, and the number of disorders screened has expanded substantially in recent years. However, there is a lack of evidence regarding minimum blood spot quality acceptance criteria for sample analysis. METHODS: Blood pools were spiked with phenylalanine, tyrosine, leucine, methionine, octanoylcarnitine, decanoylcarnitine, isovalerylcarnitine, glutarylcarnitine, thyroid-stimulating hormone, and immunoreactive trypsinogen to concentrations at the analytical cutoffs used in UK screening protocols. We evaluated the effect of sample volume applied to the card (10, 20, 50, 75, and 100 µL), punch location (central vs peripheral), and sample quality (double layering, applying blood to both sides of the filter paper, multispotting, applying insufficient sample, and compressing the sample after application). RESULTS: Compression of blood spots produced significantly lower results (14%-44%) for all analytes measured (P < 0.001). Smaller blood spots produced significantly lower results (15%-24% for 10-µL vs 50-µL sample size) for all analytes at all concentrations measured (P < 0.001). Results obtained from peripheral punches were higher than those from a central punch, although this did not reach statistical significance for all analytes. Insufficient and multispotted samples demonstrated heterogeneous results. CONCLUSIONS: All blood spots containing ≤20 µL (blood spot diameter <8 mm), those in which blood has not fully penetrated the filter paper, and all samples with evidence of compression should be rejected, since there is a risk of producing false-negative results.


Assuntos
Coleta de Amostras Sanguíneas/normas , Teste em Amostras de Sangue Seco/normas , Triagem Neonatal/métodos , Triagem Neonatal/normas , Adulto , Fluorescência , Humanos , Imunoensaio , Recém-Nascido , Masculino
10.
Clin Chem ; 60(2): 373-80, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24158758

RESUMO

BACKGROUND: The currently recommended technologies of HPLC and isoelectric focusing for newborn blood spot screening for sickle cell disease (SCD) identify both the disease and carrier states, resulting in large numbers of infants being followed up unnecessarily. Analysis of blood spot tryptic peptides performed by using tandem mass spectrometry (MS/MS) is an alternative technology to detect hemoglobin (Hb) variant disorders. METHODS: We analyzed 2154 residual newborn blood spots and 675 newborn blood spots from infants with Hb variants by using MS/MS after trypsin digestion. Screening cutoffs were developed by using the ratio between the variant peptide-to-wild-type peptide abundance for HbS, C, D(Punjab), O(Arab), Lepore, and E peptides. A postanalytical data analysis protocol was developed using these cutoffs to detect only the disease states of SCD and not to identify carrier states. A parallel study of 13 249 newborn blood spots from a high-prevalence SCD area were analyzed by both MS/MS and HPLC. RESULTS: Screening cutoffs developed distinguished the infants with the disease states of SCD, infants who were carriers of SCD, and infants with normal Hb. In the parallel study no false-negative results were identified, and all clinically relevant cases were correctly identified using the MS/MS protocol. Unblinding the data revealed a total of 328 carrier infants that were successfully excluded by the protocol. CONCLUSIONS: The screening protocol developed correctly identified infants with the disease states of SCD. Furthermore, large numbers of sickle cell carrier infants were successfully not identified, thereby avoiding unnecessary follow-up testing and referral for genetic counseling.


Assuntos
Anemia Falciforme/sangue , Testes Genéticos/métodos , Hemoglobina Falciforme/isolamento & purificação , Triagem Neonatal/métodos , Espectrometria de Massas em Tandem/métodos , Anemia Falciforme/epidemiologia , Anemia Falciforme/genética , Coleta de Amostras Sanguíneas , Cromatografia Líquida de Alta Pressão/métodos , Variação Genética , Hemoglobina Falciforme/genética , Hemoglobinas Anormais/genética , Hemoglobinas Anormais/isolamento & purificação , Humanos , Recém-Nascido , Focalização Isoelétrica , Fragmentos de Peptídeos/análise , Sensibilidade e Especificidade , Traço Falciforme/sangue , Traço Falciforme/epidemiologia , Traço Falciforme/genética , Tripsina/química
11.
Clin Endocrinol (Oxf) ; 81(4): 606-9, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24801193

RESUMO

OBJECTIVE: Population iodine status can be assessed by urinary iodine concentrations, prevalence of goitre, frequency of newborn thyroid-stimulating hormone (TSH) >5 mU/l and blood thyroglobulin concentrations. The UK population has historically been considered to be iodine sufficient; however, a recent survey of UK schoolgirls has demonstrated median urinary iodine concentrations consistent with mild iodine deficiency. The aim of our study was to assess the prevalence of TSH >5 mU/l in the newborn blood spot screening samples from the eligible population in Wales between 2011 and 2013 to assess iodine sufficiency. MEASUREMENTS: Blood spot TSH data for 104 992 infants during this time period were evaluated. RESULTS: The prevalence of TSH >5 mU/l in samples collected on days 4 and 5 of life were 1·5% and 0·9%, respectively. No increasing trend in blood spot TSH concentration was identified over the 3 years. CONCLUSIONS: The distribution of blood spot TSH data from neonates in Wales has revealed no evidence to support the hypothesis that the population is iodine deficient. However, given that mild iodine deficiency has been reported in a cohort that will be childbearing in the next decade, we recommend that the distribution of neonatal blood spot TSH concentrations is monitored by the UK newborn screening programmes to identify any emerging trends in iodine status. Further studies to correlate maternal urinary iodine and newborn blood spot TSH are required to clarify the TSH cut-off points associated with mild iodine deficiency relevant to the time of blood spot sampling in the UK.


Assuntos
Iodo/urina , Tireotropina/sangue , Bócio/sangue , Humanos , Recém-Nascido , Tireoglobulina/sangue , País de Gales/epidemiologia
12.
Int J Neonatal Screen ; 10(1)2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38535128

RESUMO

Since the UK commenced newborn screening for isovaleric acidemia in 2015, changes in prescribing have increased the incidence of false positive (FP) results due to pivaloylcarnitine. A review of screening results between 2015 and 2022 identified 24 true positive (TP) and 84 FP cases, with pivalate interference confirmed in 76/84. Initial C5 carnitine (C5C) did not discriminate between FP and TP with median (range) C5C of 2.9 (2.0-9.6) and 4.0 (1.8->70) µmol/L, respectively, and neither did Precision Newborn Screening via Collaborative Laboratory Integrated Reports (CLIR), which identified only 1/47 FP cases. However, among the TP cases, disease severity showed a correlation with initial C5C in 'asymptomatic' individuals (n = 17), demonstrating a median (range) C5C of 3.0 (1.8-7.1) whilst 'clinically affected' patients (n = 7), showed a median (range) C5C of 13.9 (7.7-70) µmol/L. These findings allowed the introduction of dual cut-off values into the screening algorithm to reduce the incidence of FPs, with initial C5C results ≥ 5 µmol/L triggering urgent referral, and those >2.0 and <5.0 µmol/L prompting second-tier C5-isobar testing. This will avoid delayed referral in babies at particular risk whilst reducing the FP rate for the remainder.

13.
J Nutr ; 143(2): 142-7, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23236022

RESUMO

Plasma vitamin B-12 is the most commonly used biomarker of vitamin B-12 status, but the predictive value for low vitamin B-12 status is poor. The urinary methylmalonic acid (uMMA) concentration has potential as a functional biomarker of vitamin B-12 status, but the response to supplemental vitamin B-12 is uncertain. A study was conducted to investigate the responsiveness of uMMA to supplemental vitamin B-12 in comparison with other biomarkers of vitamin B-12 status [plasma vitamin B-12, serum holotranscobalamin (holoTC), plasma MMA] in elderly people with moderately poor vitamin B-12 status. A double-blind, placebo-controlled, randomized 8-wk intervention study was carried out using vitamin B-12 supplements (500 µg/d, 100 µg/d, and 10 µg/d cyanocobalamin) in 100 elderly people with a combined plasma vitamin B-12 <250 pmol/L and uMMA ratio (µmol MMA/mmol creatinine) >1.5. All biomarkers had a dose response to supplemental vitamin B-12. Improvements in plasma vitamin B-12 and serum holoTC were achieved at cobalamin supplements of 10 µg/d, but even 500 µg/d for 8 wk did not normalize plasma vitamin B-12 in 8% and serum holoTC in 12% of people. The response in uMMA was comparable with plasma MMA; 15-25% of people still showed evidence of metabolic deficiency after 500 µg/d cobalamin for 8 wk. There was a differential response in urinary and plasma MMA according to smoking behavior; the response was enhanced in ex-smokers compared with never-smokers. uMMA offers an alternative marker of metabolic vitamin-B12 status, obviating the need for blood sampling.


Assuntos
Envelhecimento , Suplementos Nutricionais , Ácido Metilmalônico/urina , Estado Nutricional , Deficiência de Vitamina B 12/dietoterapia , Vitamina B 12/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Apoproteínas/sangue , Biomarcadores/sangue , Biomarcadores/urina , Creatinina/urina , Estudos Transversais , Método Duplo-Cego , Feminino , Humanos , Masculino , Ácido Metilmalônico/sangue , Cooperação do Paciente , Fumar/efeitos adversos , Fatores de Tempo , Transcobalaminas/análise , Vitamina B 12/sangue , Vitamina B 12/uso terapêutico , Deficiência de Vitamina B 12/sangue , Deficiência de Vitamina B 12/fisiopatologia , Deficiência de Vitamina B 12/urina
14.
Clin Chim Acta ; 547: 117418, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37276944

RESUMO

BACKGROUND: Dried blood spot (DBS) size and quality affect newborn screening (NBS) test results. Visual assessment of DBS quality is subjective. METHODS: We developed and validated a computer vision (CV) algorithm to measure DBS diameter and identify incorrectly applied blood in images from the Panthera DBS puncher. We used CV to assess historical trends in DBS quality and correlate DBS diameter to NBS analyte concentrations in 130,620 specimens. RESULTS: CV estimates of DBS diameter were precise (percentage coefficient of variation < 1.3%) and demonstrated excellent agreement with digital calipers with a mean (standard deviation) difference of 0.23 mm (0.18 mm). An optimised logistic regression model showed a sensitivity of 94.3% and specificity of 96.8% for detecting incorrectly applied blood. In a validation set of images (n = 40), CV agreed with an expert panel in all acceptable specimens and identified all specimens rejected by the expert panel due to incorrect blood application or DBS diameter > 14 mm. CV identified a reduction in unsuitable NBS specimens from 25.5% in 2015 to 2% in 2021. Each mm decrease in DBS diameter decreased analyte concentrations by up to 4.3%. CONCLUSIONS: CV can aid assessment of DBS size and quality to harmonize specimen rejection both within and between laboratories.


Assuntos
Teste em Amostras de Sangue Seco , Triagem Neonatal , Recém-Nascido , Humanos , Teste em Amostras de Sangue Seco/métodos , Triagem Neonatal/métodos , Coleta de Amostras Sanguíneas/métodos , Algoritmos , Laboratórios
15.
Clin Nutr ESPEN ; 55: 425-427, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37202078

RESUMO

BACKGROUND & AIMS: Cellular uptake of the essential nutrient vitamin B12 (cobalamin) occurs via the transcobalamin receptor (TCblR/CD320), a ubiquitous membrane receptor. Polymorphisms in the receptor exist, though the effect of such variants across patient populations is unknown. METHODS: We determined CD320 genotype in 377 randomly selected elderly individuals. RESULTS: Three polymorphisms and a codon deletion were identified in the exon 2 region. Haplotype variants had significantly higher holotranscobalamin (holo-TC) values and a higher holo-TC/total cobalamin ratio. TCblR haplotype explained 46% of the variability in holo-TC values. CONCLUSIONS: This has significant implications for the clinical utility of the 'combined indicator' of B12 status since it is based on a standard rate of intracellular flux via the TC-Cbl receptor. Modification of the model may be required to account for CD320 haplotype.


Assuntos
Receptores de Superfície Celular , Vitamina B 12 , Idoso , Humanos , Mutação , Polimorfismo Genético , Receptores de Superfície Celular/genética
16.
Int J Neonatal Screen ; 9(1)2023 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-36975853

RESUMO

In 1963, Robert Guthrie's pioneering work developing a bacterial inhibition assay to measure phenylalanine in dried blood spots, provided the means for whole-population screening to detect phenylketonuria in the USA. In the following decades, NBS became firmly established as a part of public health in developed countries. Technological advances allowed for the addition of new disorders into routine programmes and thereby resulted in a paradigm shift. Today, technological advances in immunological methods, tandem mass spectrometry, PCR techniques, DNA sequencing for mutational variant analysis, ultra-high performance liquid chromatography (UPLC), iso-electric focusing, and digital microfluidics are employed in the NBS laboratory to detect more than 60 disorders. In this review, we will provide the current state of methodological advances that have been introduced into NBS. Particularly, 'second-tier' methods have significantly improved both the specificity and sensitivity of testing. We will also present how proteomic and metabolomic techniques can potentially improve screening strategies to reduce the number of false-positive results and improve the prediction of pathogenicity. Additionally, we discuss the application of complex, multiparameter statistical procedures that use large datasets and statistical algorithms to improve the predictive outcomes of tests. Future developments, utilizing genomic techniques, are also likely to play an increasingly important role, possibly combined with artificial intelligence (AI)-driven software. We will consider the balance required to harness the potential of these new advances whilst maintaining the benefits and reducing the risks for harm associated with all screening.

17.
JIMD Rep ; 64(6): 468-476, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37927487

RESUMO

Measurement of plasma and dried blood spot (DBS) phenylalanine (Phe) is key to monitoring patients with phenylketonuria (PKU). The relationship between plasma and capillary DBS Phe concentrations has been investigated previously, however, differences in methodology, calibration approach and assumptions about the volume of blood in a DBS sub-punch has complicated this. Volumetric blood collection devices (VBCDs) provide an opportunity to re-evaluate this relationship. Paired venous and capillary samples were collected from patients with PKU (n = 51). Capillary blood was collected onto both conventional newborn screening (NBS) cards and VBCDs. Specimens were analysed by liquid-chromatography tandem mass-spectrometry (LC-MS/MS) using a common calibrator. Use of VBCDs was evaluated qualitatively by patients. Mean bias between plasma and volumetrically collected capillary DBS Phe was -13%. Mean recovery (SD) of Phe from DBS was 89.4% (4.6). VBCDs confirmed that the volume of blood typically assumed to be present in a 3.2 mm sub-punch is over-estimated by 9.7%. Determination of the relationship between plasma and capillary DBS Phe, using a single analytical method, common calibration and VBCDs, demonstrated that once the under-recovery of Phe from DBS has been taken into account, there is no significant difference in the concentration of Phe in plasma and capillary blood. Conversely, comparison of plasma Phe with capillary DBS Phe collected on a NBS card highlighted the limitations of this approach. Introducing VBCDs for the routine monitoring of patients with PKU would provide a simple, acceptable specimen collection technique that ensures consistent sample quality and produces accurate and precise blood Phe results which are interchangeable with plasma Phe.

18.
Ann Clin Biochem ; 60(3): 208-211, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36762708

RESUMO

BACKGROUND: Sapropterin has been approved as a treatment option for individuals with Phenylketonuria in the United Kingdom. Individuals are assessed as responsive to Sapropterin by a ≥30% reduction in Phenylalanine (Phe) concentrations using dried blood spot (DBS) specimens. DBS quality is critical for accurate and precise measurement of Phe. Currently, UK national guidelines for DBS specimen acceptance do not exist for patient-collected DBS specimens. We adopted evidence-based guidelines for specimen acceptance criteria and retrospectively assessed the impact of introducing these guidelines on specimen rejection rates. Methods: Laboratories were invited to audit the quality of DBS specimens routinely received for Phe monitoring using: (1) existing acceptance/rejection criteria and (2) proposed national guidelines. RESULTS: Ten laboratories audited 2111 specimens from 1094 individuals. Using existing local guidelines, the median rejection rate was 4.0% (IQR 1.5-7.2%). This increased to 21.9% (IQR 10.0-33.0%) using the proposed guidelines. Where reason(s) for rejection were provided (n = 299); 211/299 (70.6%) of DBS specimens were too small or multi-spotted. 380 individuals had more than one sample evaluated; 231/380 (60.8%) provided specimens of acceptable quality, 37/380 (9.7%) consistently provided poor-quality DBS specimens. CONCLUSIONS: There is significant variability in the quality of patient-collected DBS specimens. If unacceptable specimens are not rejected, imprecise/inaccurate results will be used in clinical decision making. Using annual workload data for England, this equates to 12,410 incorrect results. Individuals and parents/carers should receive ongoing training in blood collection technique to ensure use of evidence-based acceptability criteria does not cause undue distress from increased sample rejection rates.


Assuntos
Laboratórios , Fenilcetonúrias , Humanos , Estudos Transversais , Estudos Retrospectivos , Fenilalanina/uso terapêutico
19.
Int J Neonatal Screen ; 9(3)2023 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-37754778

RESUMO

The collection of dried blood spots (DBS) facilitates newborn screening for a variety of rare, but very serious conditions in healthcare systems around the world. Sub-punches of varying sizes (1.5-6 mm) can be taken from DBS specimens to use as inputs for a range of biochemical assays. Advances in DNA sequencing workflows allow whole-genome sequencing (WGS) libraries to be generated directly from inputs such as peripheral blood, saliva, and DBS. We compared WGS metrics obtained from libraries generated directly from DBS to those generated from DNA extracted from peripheral blood, the standard input for this type of assay. We explored the flexibility of DBS as an input for WGS by altering the punch number and size as inputs to the assay. We showed that WGS libraries can be successfully generated from a variety of DBS inputs, including a single 3 mm or 6 mm diameter punch, with equivalent data quality observed across a number of key metrics of importance in the detection of gene variants. We observed no difference in the performance of DBS and peripheral-blood-extracted DNA in the detection of likely pathogenic gene variants in samples taken from individuals with cystic fibrosis or phenylketonuria. WGS can be performed directly from DBS and is a powerful method for the rapid discovery of clinically relevant, disease-causing gene variants.

20.
Int J Neonatal Screen ; 10(1)2023 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-38248630

RESUMO

In the UK, Classical Galactosaemia (CG) is identified incidentally from the Newborn Screening (NBS) for phenylketonuria (PKU) using an "Other disorder suspected" (ODS) pathway when phenylalanine (Phe) and tyrosine (Tyr) concentrations are increased. We aimed to determine the efficacy of CG detection via NBS and estimate the incidence of CG in live births in the UK. A survey was sent to all UK NBS laboratories to collate CG cases diagnosed in the UK from 2010 to 2020. Cases of CG diagnosed were determined if detected clinically, NBS, or by family screening, as well as age at diagnosis. Cases referred via the ODS pathway were also collated, including the final diagnosis made. Responses were obtained from 13/16 laboratories. Between 2010 and 2020, a total of 6,642,787 babies were screened, and 172 cases of CG were identified. It should be noted that 85/172 presented clinically, 52/172 were identified by NBS, and 17/172 came from family screening. A total of 117 referrals were made via the ODS pathway, and 45/117 were subsequently diagnosed with CG. Median (interquartile range) age at diagnosis by NBS and clinically was 8 days (7-11) and 10 days (7-16), respectively (Mann-Whitney U test, U = 836.5, p-value = 0.082). The incidence of CG is 1:38,621 live births. The incidence of CG in the UK is comparable with that of other European/western countries. No statistical difference was seen in the timing of diagnosis between NBS and clinical presentation based on the current practice of sampling on day 5. Bringing forward the day of NBS sampling to day 3 would increase the proportion diagnosed with CG by NBS from 52/172 (30.2%) to 66/172 (38.4%).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA