Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Org Biomol Chem ; 13(46): 11220-7, 2015 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-26403518

RESUMO

Tumor hypoxia is associated with the rapid proliferation and growth of malignant tumors, and the ability to detect tumor hypoxia is important for predicting tumor response to anti-cancer treatments. We have developed a class of dye-conjugates that are related to indocyanine green (ICG, ) to target tumor hypoxia, based on in vivo infrared fluorescence imaging using nitroimidazole moieties linked to indocyanine fluorescent dyes. We previously reported that linking 2-nitroimidazole to an indocyanine dicarboxylic acid dye derivative () using an ethanolamine linker (ethanolamine-2-nitroimidazole-ICG, ), led to a dye-conjugate that gave promising results for targeting cancer hypoxia in vivo. Structural modification of the dye conjugate replaced the ethanolamine unit with a piperazineacetyl unit and led a second generation dye conjugate, piperzine-2-nitroimidazole-ICG (). This second generation dye-conjugate showed improved targeting of tumor hypoxia when compared with . Based on the hypothesis that molecules with more planar and rigid structures have a higher fluorescence yield, as they could release less absorbed energy through molecular vibration or collision, we have developed a new 2-nitroimidazole ICG conjugate, , with two carbon atoms less in the polyene linker. Dye-conjugate was prepared from our new dye (), and coupled to 2-nitroimidazole using a piperazine linker to produce this third-generation dye-conjugate. Spectral measurements showed that the absorption/emission wavelengths of 657/670 were shifted ∼100 nm from the second-generation hypoxia dye of 755/780 nm. Its fluorescence quantum yield was measured to be 0.467, which is about 5 times higher than that of (0.083). In vivo experiments were conducted with balb/c mice and showed more than twice the average in vivo fluorescence intensity in the tumor beyond two hours post retro-orbital injection as compared with . These initial results suggest that may significantly improve in vivo tumor hypoxia targeting.


Assuntos
Corantes Fluorescentes/química , Hipóxia/complicações , Hipóxia/diagnóstico , Verde de Indocianina/análogos & derivados , Neoplasias/complicações , Imagem Óptica , Animais , Hipóxia Celular , Linhagem Celular Tumoral , Corantes Fluorescentes/farmacocinética , Verde de Indocianina/farmacocinética , Camundongos Endogâmicos BALB C , Neoplasias/patologia , Nitroimidazóis/química , Nitroimidazóis/farmacocinética
2.
Chem Commun (Camb) ; 59(55): 8552-8555, 2023 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-37337906

RESUMO

Firefly luciferin methyl ester is hydrolyzed by monoacylglycerol lipase MAGL, amidase FAAH, poorly-characterized hydrolase ABHD11, and hydrolases known for S-depalmitoylation (LYPLA1/2), not just esterase CES1. This enables activity-based bioluminescent assays for serine hydrolases and suggests that the 'esterase activity' responsible for hydrolyzing ester prodrugs is more diverse than previously supposed.


Assuntos
Luciferina de Vaga-Lumes , Monoacilglicerol Lipases , Amidoidrolases , Serina , Inibidores Enzimáticos
3.
J Biol Rhythms ; 37(1): 78-93, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34873943

RESUMO

Circadian rhythms are driven by daily oscillations of gene expression. An important tool for studying cellular and tissue circadian rhythms is the use of a gene reporter, such as bioluminescence from the reporter gene luciferase controlled by a rhythmically expressed gene of interest. Here we describe methods that allow measurement of circadian bioluminescence from a freely moving mouse housed in a standard cage. Using a LumiCycle In Vivo (Actimetrics), we determined conditions that allow detection of circadian rhythms of bioluminescence from the PER2 reporter, PER2::LUC, in freely behaving mice. The LumiCycle In Vivo applies a background subtraction that corrects for effects of room temperature on photomultiplier tube (PMT) output. We tested delivery of d-luciferin via a subcutaneous minipump and in the drinking water. We demonstrate spikes in bioluminescence associated with drinking bouts. Further, we demonstrate that a synthetic luciferase substrate, CycLuc1, can support circadian rhythms of bioluminescence, even when delivered at a lower concentration than d-luciferin, and can support longer-term studies. A small difference in phase of the PER2::LUC bioluminescence rhythms, with females phase leading males, can be detected with this technique. We share our analysis scripts and suggestions for further improvements in this method. This approach will be straightforward to apply to mice with tissue-specific reporters, allowing insights into responses of specific peripheral clocks to perturbations such as environmental or pharmacological manipulations.


Assuntos
Ritmo Circadiano , Proteínas Circadianas Period , Animais , Ritmo Circadiano/fisiologia , Feminino , Luciferases/genética , Luciferases/metabolismo , Masculino , Camundongos , Proteínas Circadianas Period/genética , Proteínas Circadianas Period/metabolismo , Núcleo Supraquiasmático/fisiologia
4.
J Biomed Opt ; 18(9): 096006, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24002193

RESUMO

A photoacoustic contrast agent that is based on bis-carboxylic acid derivative of indocyanine green (ICG) covalently conjugated to single-wall carbon nanotubes (ICG/SWCNT) is presented. Covalently attaching ICG to the functionalized SWCNT provides a more robust system that delivers much more ICG to the tumor site. The detection sensitivity of the new contrast agent in a mouse tumor model is demonstrated in vivo by our custom-built photoacoustic imaging system. The summation of the photoacoustic tomography (PAT) beam envelope, referred to as the "PAT summation," is used to demonstrate the postinjection light absorption of tumor areas in ICG- and ICG/SWCNT-injected mice. It is shown that ICG is able to provide 33% enhancement at approximately 20 min peak response time with reference to the preinjection PAT level, while ICG/SWCNT provides 128% enhancement at 80 min and even higher enhancement of 196% at the end point of experiments (120 min on average). Additionally, the ICG/SWCNT enhancement was mainly observed at the tumor periphery, which was confirmed by fluorescence images of the tumor samples. This feature is highly valuable in guiding surgeons to assess tumor boundaries and dimensions in vivo and to achieve clean tumor margins to improve surgical resection of tumors.


Assuntos
Meios de Contraste/química , Verde de Indocianina/química , Nanotubos de Carbono/química , Técnicas Fotoacústicas/métodos , Animais , Feminino , Processamento de Imagem Assistida por Computador , Camundongos , Camundongos Endogâmicos BALB C , Neoplasias Experimentais/patologia , Tomografia/métodos
5.
J Biomed Opt ; 18(6): 66009, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23764695

RESUMO

Tumor hypoxia is a major indicator of treatment resistance to chemotherapeutic drugs, and fluorescence optical tomography has tremendous potential to provide clinically useful, functional information by identifying tumor hypoxia. The synthesis of a 2-nitroimidazole-indocyanine green conjugate using a piperazine linker (piperazine-2-nitroimidazole-ICG) capable of robust fluorescent imaging of tumor hypoxia is described. In vivo mouse tumor imaging studies were completed and demonstrate an improved imaging capability of the new dye relative to an earlier version of the dye that was synthesized with an ethanolamine linker (ethanolamine-2-nitroimidazole-ICG). Mouse tumors located at imaging depths of 1.5 and 2.0 cm in a turbid medium were imaged at various time points after intravenous injection of the dyes. On average, the reconstructed maximum fluorescence concentration of the tumors injected with piperazine-2-nitroimidazole-ICG was twofold higher than that injected with ethanolamine-2-nitroimidazole-ICG within 3 h postinjection period and 1.6 to 1.7 times higher beyond 3 h postinjection. The untargeted bis-carboxylic acid ICG completely washed out after 3 h postinjection. Thus, the optimal window to assess tumor hypoxia is beyond 3 h postinjection. These findings were supported with fluorescence images of histological sections of tumor samples and an immunohistochemistry technique for identifying tumor hypoxia.


Assuntos
Corantes/farmacologia , Hipóxia , Verde de Indocianina/farmacologia , Neoplasias/patologia , Nitroimidazóis/farmacologia , Animais , Linhagem Celular Tumoral , Desenho de Equipamento , Etanolamina/farmacologia , Feminino , Imuno-Histoquímica , Espectroscopia de Ressonância Magnética , Camundongos , Camundongos Endogâmicos BALB C , Transplante de Neoplasias , Espectrometria de Fluorescência , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA