Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Cryogenics (Guildf) ; 1212022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36779016

RESUMO

With the emerging recognition of open scientific hardware, rapid prototyping technology such as three-dimensional (3-D) printing is becoming widely available for fields such as cryobiology, and cryopreservation, where material selection for instruments and hardware has traditionally been problematic due to extreme low temperatures. A better understanding of the mechanical properties of 3-D printing thermoplastics at cryogenic temperatures is essential to material selection, part design, and printing optimization. The goal of the present study was to explore the feasibility of development for a 3-D printed device ('CryoTensileDevice') to hold a test specimen in liquid nitrogen and be mounted in standard mechanical testing systems to evaluate 3-D printing material behaviors at cryogenic temperatures. The CryoTensileDevice was prototyped with flexible filaments with a per-unit material cost of < US$5 and a printing time of < 5 h. The commonly used printing filament polylactic acid (PLA) was selected to evaluate the utility of the CryoTensileDevice. At room temperature, the CryoTensileDevice did not significantly (P > 0.05) affect PLA tensile measurements such as Young's modulus, yield stress, yield strain, stress at break, or strain at break. With the CryoTensileDevice, specimens 3-D printed with PLA at 50%, 75%, and 100% infill rates had comparable tensile properties when tested at room and liquid nitrogen temperatures. The PLA showed superior performance in tensile properties in comparison to acrylonitrile butadiene styrene (ABS). This device can assist characterization of 3-D printing approaches for cryogenic work, and opens a pathway for future innovations to create a variety of 3-D printed devices to study a wide range of material properties for cryogenic applications.

2.
Aquac Eng ; 952021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37736500

RESUMO

A great challenge among communities participating in germplasm repository development is to obtain suitable cryopreservation equipment and devices. Commercial programmable freezers are costly and thus unaffordable to many users. Self-made devices have substantial variability among users, resulting in few opportunities for standardization across communities. The development of open hardware with the increasing accessibility of three-dimensional (3-D) printing offers rapid prototyping and easy fabrication of devices by users around the world at low cost. The present study explored the feasibility of developing operational prototypes of 3-D printed motorized cryopreservation devices for continuous freezing of non-batched samples. A controlled cooling conveyor device (CCCD) was designed and fabricated to cryopreserve sperm samples in straws that were loaded onto chain links suspended over liquid nitrogen held in a Styrofoam box. Cooling rates of 5 to 34 °C/min for 0.5-ml French straws were produced by adjusting the height of conveyor chains, slopes, and liquid nitrogen mass. The plunge temperature (-47 °C to -61 °C) was controlled by adjustment of conveyor speed. The cooling curves from the CCCD were comparable to a commercial programmable freezer. There were no significant differences in post-thaw motility of sperm from ornamental (Koi) common carp (Cyprinus carpio) among samples frozen with the CCCD and those frozen with a commercial programmable freezer. The post-thaw sperm motility was consistent among samples frozen in the CCCD across a 15-min time span. The CCCD prototypes in the present study proved to be feasible and functional as low-cost, customizable, portable, and yet standardizable options for freezing of individual (non-batched) samples. Additional design alternatives are proposed to facilitate further adaptation and development by diverse user communities.

3.
Reprod Fertil Dev ; 32(9): 873-878, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32527377

RESUMO

Evaluation of sperm concentration is essential for research and procedures involving AI, cryopreservation and sperm quality assessment. Microfabrication technologies have shown tremendous potential for rapid prototyping and fabrication of devices to assist reproduction and fertility research, but such utility has not yet been made available for most reproduction laboratories. The aim of this study was to evaluate the feasibility of using microfabrication techniques to produce counting chambers for estimation of sperm concentration. Zebrafish (Danio rerio) spermatozoa were used as a model for evaluation of functionality of the chambers. These microfabricated enumeration grid chambers (MEGC) were composed of a polydimethylsiloxane (PDMS) coverslip with grid patterns (100 µm×100 µm) and a PDMS base platform to create a known volume with a 10-µm height to restrict the cells to a single layer. The results of cell counts estimated by two of three prototype MEGC devices tested were not significantly different from the control device, a commercially available Makler chamber. The material cost for a MEGC was less than US$0.10 compared with product costs of approximately US$100 for a standard haemocytometer and US$700 for a Makler counting chamber. This study demonstrates the feasibility of microfabrication in creating low-cost counting chambers to enhance standardisation and strengthen interdisciplinary collaborations.


Assuntos
Microtecnologia , Contagem de Espermatozoides/instrumentação , Espermatozoides , Animais , Análise Custo-Benefício , Dimetilpolisiloxanos , Desenho de Equipamento , Estudos de Viabilidade , Masculino , Teste de Materiais , Contagem de Espermatozoides/economia , Contagem de Espermatozoides/normas , Peixe-Zebra
4.
Aquac Eng ; 902020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32831431

RESUMO

Sperm vitrification as an alternative approach to conventional cryopreservation (equilibrium freezing) allows quick and low-cost sample preservation and is suitable for small-bodied aquatic species with miniscule testis, fieldwork at remote locations, and small-scale freezing for research purposes. The goal of this present study was to develop operational prototypes of 3-dimensional (3-D) printed vitrification devices with innovative components that can provide comprehensive functionalities for practical repository development for aquatic species. The design featured an elongated loop to suspend a thin film of sperm sample in cryoprotectant, a retractable sleeve to protect the vitrified samples and allow permanent labeling, a handle to facilitate processing and storage, and a shaft with annular grooves to guide positioning of the protective retractable sleeve. To span a wide range of sample capacities and configurations, a total of 39 different configurations (3 loop lengths ×13 loop heights) were fabricated by 3-D printing with the thermoplastics polylactic acid (PLA) and acrylonitrile butadiene styrene (ABS). A total of 86 devices were fabricated with ABS filament with a print failure rate of 9%, and 97 devices were fabricated with PLA filament with a failure rate of 20%. Major types of printing failures included disconnected loops, insufficient build surface adhesion, stringing, and inconsistent extrusion. The sample volume capacity ranged from 1-47 µL and had linear relationships to the loop lengths and layer numbers. Vitrified samples were observed in 10-mm and 15-mm loops fabricated with PLA and ABS but not in 20-mm loops. This study demonstrated the feasibility of development of standardized low-cost ($0.05 material cost) devices fabricated by 3-D printing with practical functions including vitrification, volume control, labeling, protection, and storage within conventional systems. These prototypes can be further developed, standardized, and used to assist development of germplasm repositories to protect the genetic resources of aquatic species by user groups such as breeders, hatcheries, aquariums, and researchers.

5.
Cryobiology ; 73(3): 396-398, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27769741

RESUMO

Development of devices through design, prototyping, testing, and fabrication is especially necessary for enhancement of research and eventual application in cryobiology. The advent of 3-dimensional printing offers unique opportunities for this process, given that the materials involved are suitable for use in cryogenic temperatures. We report herein that 3-D printing with polylactic acid (PLA) thermoplastic is ideally suited for cryobiology device development. Devices that are designed and standardized in open-source fashion can be electronically distributed and created locally on increasingly affordable 3-D printers, and can accelerate cryobiology findings and improve reproducibility of results.


Assuntos
Poliésteres , Preservação Biológica/instrumentação , Impressão Tridimensional , Temperatura Baixa , Reprodutibilidade dos Testes
6.
Environ Monit Assess ; 187(6): 334, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25957195

RESUMO

On December 22, 2008, a dike containing coal fly ash at the Tennessee Valley Authority Kingston Fossil Plant (TN, USA) failed, and within months, dredging operations began to remove ash-contaminated sediments. The purpose of this study was to investigate differences in the bioaccumulation of metals in three mussel species during and after dredging operations. Mussels were caged for approximately 1 year during dredging and after, and then mussel condition index values and As, Cd, Cr, Pb, Ni, Se, Hg, U, Fe, Mg, Al, Sb, Ba, Be, Co, Cu, Mn, Mo, Ag, Sr, Tl, V, and Zn concentrations in soft tissue were determined via inductively coupled plasma-mass spectrometery. Overall, the differences observed in metal bioaccumulation and mussel health suggest that mussels in the immediate downstream area of the dredging site may have been impacted, as evidenced by a significant decrease in mussel condition index values, but that this impact did not result in increased tissue concentrations of metals.


Assuntos
Bivalves/metabolismo , Vazamento de Resíduos Químicos , Monitoramento Ambiental , Combustíveis Fósseis , Água Doce/química , Metais/metabolismo , Poluentes Químicos da Água/metabolismo , Animais , Carvão Mineral , Cinza de Carvão , Meio Ambiente , Recuperação e Remediação Ambiental , Mercúrio/análise , Metais/análise , Poluentes Químicos da Água/análise
7.
Micromachines (Basel) ; 14(2)2023 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-36837983

RESUMO

Microfluidic impedance cytometry has been demonstrated as an effective platform for single cell analysis, taking advantage of microfabricated features and dielectric cell sensing methods. In this study, we present a simple microfluidic device to improve the sensitivity, accuracy, and throughput of single suspension cell viability analysis using vertical sidewall electrodes fabricated by a widely accessible negative manufacturing method. A microchannel milled through a 75 µm platinum wire, which was embedded into poly-methyl-methacrylate (PMMA), created a pair of parallel vertical sidewall platinum electrodes. Jurkat cells were interrogated in a custom low-conductivity buffer (1.2 ± 0.04 mS/cm) to reduce current leakage and increase device sensitivity. Confirmed by live/dead staining and electron microscopy, a single optimum excitation frequency of 2 MHz was identified at which live and dead cells were discriminated based on the disruption in the cell membrane associated with cell death. At this frequency, live cells were found to exhibit changes in the impedance phase with no appreciable change in magnitude, while dead cells displayed the opposite behavior. Correlated with video microscopy, a computational algorithm was created that could identify cell detection events and determine cell viability status by application of a mathematical correlation method.

8.
Aquat Toxicol ; 256: 106400, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36805196

RESUMO

The use of 3-dimensional (3-D) printing is gaining popularity in life sciences and driving innovation in fields including aquatic sperm cryopreservation. Yet, little is known about the effects leachates from these objects may have on biological systems. In this study, we investigated if exposure to leachates from 3-D printed objects fabricated from different photo-curable resins could affect sperm quality in two model fish species, zebrafish (Danio rerio) and goldfish (Carassius auratus). Leachates were collected following contact periods of 10 min and 22 h with objects manufactured using a mask LCD resin printer and three different commercially available resins (i.e., standard, eco-friendly, and impact-resistant). Sperm cells were exposed to the leachates for 18 min, and parameters related to sperm motility, cell count, and membrane integrity were evaluated. All experiments were blinded. Leachate originating from contact with impact-resistant resin for 10 min significantly reduced the cell count of zebrafish sperm, while leachate originating from contact with standard resin for 22 h significantly increased the beat cross frequency of goldfish sperm. The changes were not observed across species and no adverse effects were recorded in percent motility, velocity, amplitude of lateral head movement, or membrane integrity of sperm. Our findings demonstrate that exposure to leachates from certain 3-D printed resins can affect sperm quality, while other resins may support sperm quality evaluation. Further investigations are warranted to assess other parameters, effects, and their biological relevance for a variety of aquatic species.


Assuntos
Poluentes Químicos da Água , Peixe-Zebra , Animais , Masculino , Motilidade dos Espermatozoides , Poluentes Químicos da Água/toxicidade , Sêmen , Espermatozoides , Carpa Dourada
9.
Adv Biol (Weinh) ; 7(8): e2200332, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37236203

RESUMO

Hydrogels are 3D scaffolds used as alternatives to in vivo models for disease modeling and delivery of cells and drugs. Existing hydrogel classifications include synthetic, recombinant, chemically defined, plant- or animal-based, and tissue-derived matrices. There is a need for materials that can support both human tissue modeling and clinically relevant applications requiring stiffness tunability. Human-derived hydrogels are not only clinically relevant, but they also minimize the use of animal models for pre-clinical studies. This study aims to characterize XGel, a new human-derived hydrogel as an alternative to current murine-derived and synthetic recombinant hydrogels that features unique physiochemical, biochemical, and biological properties that support adipocyte and bone differentiation. Rheology studies determine the viscosity, stiffness, and gelation features of XGel. Quantitative studies for quality control support consistency in the protein content between lots. Proteomics studies reveal that XGel is predominantly composed of extracellular matrix proteins, including fibrillin, collagens I-VI, and fibronectin. Electron microscopy of the hydrogel provides phenotypic characteristics in terms of porosity and fiber size. The hydrogel demonstrates biocompatibility as a coating material and as a 3D scaffold for the growth of multiple cell types. The results provide insight into the biological compatibility of this human-derived hydrogel for tissue engineering.


Assuntos
Hidrogéis , Células-Tronco , Engenharia Tecidual , Hidrogéis/química , Humanos , Matriz Extracelular , Proliferação de Células , Células-Tronco/citologia
10.
J Nanobiotechnology ; 10: 45, 2012 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-23241497

RESUMO

BACKGROUND: Various obstacles are encountered by mammalian spermatozoa during their journey through the female genital tract, and only few or none will reach the site of fertilization. Currently, there are limited technical approaches for non-invasive investigation of spermatozoa migration after insemination. As the knowledge surrounding sperm behavior throughout the female genital tract still remains elusive, the recent development of self-illuminating quantum dot nanoparticles may present a potential means for real-time in vitro and in vivo monitoring of spermatozoa. RESULTS: Here, we show the ability of boar spermatozoa to harmlessly interact and incorporate bioluminescent resonance energy transfer-conjugated quantum dot (BRET-QD) nanoparticles. The confocal microscope revealed in situ fluorescence of BRET-QD in the entire spermatozoon, while the ultra-structural analysis using the transmission electron microscope indicated BRET-QD localization on the sperm plasma membrane and intracellular compartment. In controlled-in vitro assays, bioluminescent imaging demonstrated that spermatozoa incubated with BRET-QD and luciferase substrate (coelenterazine) emit light (photons/sec) above the background, which confirmed the in situ fluorescence imaging. Most importantly, sperm motility, viability, and fertilizing potential were not affected by the BRET-QD incorporation when used at an appropriated ratio. CONCLUSIONS: Our results demonstrate that pig spermatozoa can incorporate BRET-QD nanoparticles without affecting their motility and capacity to interact with the oocyte when used at an appropriated balance. We anticipate that our study will enable in-depth exploration of the male components of in vivo migration, fertilization, and embryonic development at the molecular level using this novel approach.


Assuntos
Microscopia Confocal/métodos , Pontos Quânticos , Espermatozoides/citologia , Animais , Sobrevivência Celular/efeitos dos fármacos , Corantes Fluorescentes/química , Corantes Fluorescentes/farmacologia , Imidazóis , Luciferases , Masculino , Pirazinas , Espermatozoides/efeitos dos fármacos , Espermatozoides/fisiologia , Sus scrofa
11.
Fishes ; 7(1)2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36644437

RESUMO

Germplasm repositories can benefit sustainable aquaculture by supporting genetic improvement, assisted reproduction, and management of valuable genetic resources. Lack of reliable quality management tools has impeded repository development in the past several decades. Microfabricated open-hardware devices have emerged as a new approach to assist repository development by providing standardized quality assessment capabilities to enable routine quality control. However, prototyping of microfabricated devices (microdevices) traditionally relies on photolithography techniques that are costly, time intensive, and accessible only through specialized engineering laboratories. Although resin 3-D printing has been introduced into the microfabrication domain, existing publications focus on customized or high-cost (>thousands of USD) printers. The goal of this report was to identify and call attention to the emerging opportunities to support innovation in microfabrication by use of low-cost (

12.
Fishes ; 7(5)2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36644608

RESUMO

Accurate determination of sperm concentration in aquatic species is important for assisted reproduction and cryopreservation, yet is challenging as current counting methods are costly or not suitable for many species. The goal of this work was to develop a simple (single-piece and single-layer photolithography) sperm counting chamber (SSCC) for aquatic species. Goldfish (Carassius auratus) and zebrafish (Danio rerio) sperm were used for evaluation in the device, which was created with soft lithography. Four designs with different geometries were evaluated for counting accuracy. Open-corner and open-midpoint designs were the most accurate with no significant differences (P > 0.05) for most of the target sperm concentrations (0.5-1.0 × 108 cells/mL). The open-corner design was not significantly different from the Makler® counting chamber intended for human sperm cells (P = 0.6) but was significantly different from a hemocytometer (P < 0.001) intended for other cell sizes. Material cost of device production was USD 16 per unit, including photolithography supplies, glass slide and coverslip, and polydimethylsiloxane. The cost can be reduced to USD 2 per unit with repeated wafer casts. This device could be further refined for resin 3-D printing and sharing via open-hardware approaches and modified to best suit species specific applications.

13.
Animals (Basel) ; 12(8)2022 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-35454209

RESUMO

Small-bodied live-bearing fishes attract broad attention because of their importance in biomedical research and critical conservation status in natural habitats. Artificial insemination is an essential process to establish hybrid lines and for the operation of sperm repositories. The existing mouth-pipetting technique for artificial insemination of live-bearing fishes has not been substantially upgraded since the first implementation in the 1950s. The goal of this work was to develop a standardized artificial inseminator device (SAID) to address issues routinely encountered in insemination by mouth-pipetting, including lack of reproducibility among different users, difficulty in training, and large unreportable variation in sample volume and pressure during insemination. Prototypes of the SAID were designed as relatively inexpensive ( 0.99) between the piston position and volume. Pressure generation from eight mouth-pipetting operators and SAID prototypes were assessed by pressure sensors. The pressure control by SAID was superior to that produced by mouth-pipetting, yielding lower pressures (31−483 Pa) and smaller variations (standard deviation <11 Pa). These pressures were sufficient to deliver 1−5 µL of fluid into female reproductive tracts yet low enough to avoid physical injury to fish. Community-level enhancements of the SAID prototype could enable standardized insemination with minimal training and facilitate the participation of research communities in the use of cryopreserved genetic resources.

14.
NPJ Parkinsons Dis ; 8(1): 28, 2022 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-35304493

RESUMO

Identification of individuals at high risk for rapid progression of motor and cognitive signs in Parkinson disease (PD) is clinically significant. Postural instability and gait dysfunction (PIGD) are associated with greater motor and cognitive deterioration. We examined the relationship between baseline clinical factors and the development of postural instability using 5-year longitudinal de-novo idiopathic data (n = 301) from the Parkinson's Progressive Markers Initiative (PPMI). Logistic regression analysis revealed baseline features associated with future postural instability, and we designated this cohort the emerging postural instability (ePI) phenotype. We evaluated the resulting ePI phenotype rating scale validity in two held-out populations which showed a significantly higher risk of postural instability. Emerging PI phenotype was identified before onset of postural instability in 289 of 301 paired comparisons, with a median progression time of 972 days. Baseline cognitive performance was similar but declined more rapidly in ePI phenotype. We provide an ePI phenotype rating scale (ePIRS) for evaluation of individual risk at baseline for progression to postural instability.

15.
Appl Sci (Basel) ; 11(17)2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36777919

RESUMO

Sperm cryopreservation by vitrification is a promising approach for small-bodied animals such as zebrafish (Danio rerio). However, most vitrification tools adopted in aquatic research were initially designed for applications other than sperm (such as human embryo freezing) and, thus, pose challenges for adoption to sperm vitrification. Three-dimensional (3D) printing combined with open hardware sharing is an emerging strategy to address challenges in the development of cryopreservation tools. The goal of this study was to develop a 3D printed Vitrification Device for Cryo-Vials (VDCV) that can be integrated with the existing vial storage systems. The VDCV combined the vitrification and handling components to achieve functions of sample handling, vitrification, storage, and identification. The vitrification component featured a base, a stem, and a loop. A total of 36 configurations with various loop lengths (8, 10, and 12 mm); loop widths (2.0, 2.5, 3.0, and 3.5 mm); and support structures (open, transverse, and axial) of the VDCD prototypes were designed, fabricated, and tested. Device handling orientations (horizontal and vertical holding angles prior to and during freezing) were also investigated. Computer simulations estimated that the cooling rate of the samples ranged from 0.6-1.5 × 105 °C/min in all the configurations. Prior to freezing, loops with axial supports produced a minimum of 92% film retention. The overall trends of full vitrification occurrence were observed: horizontal plunging > vertical plunging, and axial support > transverse support and open loop. A loop length of 8 mm had the highest overall vitrification occurrence (86-100%). No significant differences (p = 0.6584) were shown in a volume capacity (5.7-6.0 µL) among the three supporting configurations. A single unit of VDCV can provide loading efficiencies of about 6 × 107 sperm/vial, pooling of samples from 3-6 males/vial, and fertilization for 1800 eggs/vial. The VDCV are low-cost (<$0.5 material cost per unit) and can be customized, standardized, securely labeled, and efficiently stored. The prototypes can be accessed by user communities through open-fabrication file sharing and fabricated with consumer-level 3D printers, thus facilitating community-level standardization.

16.
Neuroimage Rep ; 1(1)2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36969709

RESUMO

Background: Diffusion tensor imaging suggests that white matter alterations are already evident in first episode psychosis patients (FEP) and may become more prominent as the duration of untreated psychosis (DUP) increases. But because the tensor model lacks specificity, it remains unclear how to interpret findings on a biological level. Here, we used a biophysical diffusion model, Neurite Orientation Dispersion and Density Imaging (NODDI), to map microarchitecture in FEP, and to investigate associations between DUP and microarchitectural integrity. Methods: We scanned 78 antipsychotic medication-naïve FEP and 64 healthy controls using a multi-shell diffusion weighted sequence and used the NODDI toolbox to compute neurite density (ND), orientation dispersion index (ODI) and extracellular free water (FW) maps. AFNI's 3dttest++ was used to compare diffusion maps between groups and to perform regression analyses with DUP. Results: We found that ND was decreased in commissural and association fibers but increased in projection fibers in FEP. ODI was largely increased regardless of fiber type, and FW showed a mix of increase in decrease across fiber tracts. We also demonstrated associations between DUP and microarchitecture for all NODDI indices. Conclusions: We demonstrated that complex microarchitecture abnormalities are already evident in antipsychotic-naïve FEP. ND alterations are differentially expressed depending on fiber type, while decreased fiber complexity appears to be a uniform marker of white matter deficit in the illness. Importantly, we identified an empirical link between longer DUP and greater white matter pathology across NODDI indices, underscoring the critical importance of early intervention in this devastating illness.

17.
Ann Clin Transl Neurol ; 7(10): 1973-1984, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32991786

RESUMO

OBJECTIVE: To further evaluate the relationship between the clinical profiles and limbic and motor brain regions and their connecting pathways in psychogenic nonepileptic seizures (PNES). Neurite Orientation Dispersion and Density Indices (NODDI) multicompartment modeling was used to test the relationships between tissue alterations in patients with traumatic brain injury (TBI) and multiple psychiatric symptoms. METHODS: The sample included participants with prior TBI (TBI; N = 37) but no PNES, and with TBI and PNES (TBI + PNES; N = 34). Participants completed 3T Siemens Prisma MRI high angular resolution imaging diffusion protocol. Statistical maps, including fractional anisotropy (FA), mean diffusivity (MD), neurite dispersion [orientation dispersion index (ODI)] and density [intracellular volume fraction (ICVF), and free water (i.e., isotropic) volume fraction (V-ISO)] signal intensity, were generated for each participant. Linear mixed-effects models identified clusters of between-group differences in indices of white matter changes. Pearson's r correlation tests assessed any relationship between signal intensity and psychiatric symptoms. RESULTS: Compared to TBI, TBI + PNES revealed decreases in FA, ICVF, and V-ISO and increases in MD for clusters within cingulum bundle, uncinate fasciculus, fornix/stria terminalis, and corticospinal tract pathways (cluster threshold α = 0.05). Indices of white matter changes for these clusters correlated with depressive, anxiety, PTSD, psychoticism, and somatization symptom severity (FDR threshold α = 0.05). A follow-up within-group analysis revealed that these correlations failed to reach the criteria for significance in the TBI + PNES group alone. INTERPRETATION: The results expand support for the hypothesis that alterations in pathways comprising the specific PNES network correspond to patient profiles. These findings implicate myelin-specific changes as possible contributors to PNES, thus introducing novel potential treatment targets.


Assuntos
Anisotropia , Imageamento por Ressonância Magnética , Rede Nervosa/anatomia & histologia , Substância Branca/patologia , Adulto , Lesões Encefálicas Traumáticas/diagnóstico , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Tensor de Difusão/métodos , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Bainha de Mielina/metabolismo , Neuritos/patologia , Neuritos/ultraestrutura , Convulsões/psicologia , Substância Branca/fisiopatologia
18.
J Biomed Opt ; 14(2): 021007, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19405720

RESUMO

Nanophotothermolysis with long laser pulses for treatment of scattered cancer cells and their clusters is introduced with the main focus on real-time monitoring of temperature dynamics inside and around individual cancer cells labeled with carbon nanotubes. This technique utilizes advanced time- and spatially-resolved thermal radiometry imaging for the visualization of laser-induced temperature distribution in multiple-point absorbing targets. The capability of this approach was demonstrated for monitoring of thermal effects under long laser exposure (from millisecond to seconds, wavelength 1,064 nm, maximum power 1 W) of cervical cancer HeLa cells labeled with carbon nanotubes in vitro. The applications are discussed with a focus on the nanophotothermolysis of small tumors, tumor margins, or micrometastases under the guidance of near-IR and microwave radiometry.


Assuntos
Hipertermia Induzida/métodos , Nanotubos de Carbono , Neoplasias/patologia , Neoplasias/terapia , Fototerapia/métodos , Espectrofotometria Infravermelho/métodos , Termografia/métodos , Apoptose/efeitos da radiação , Células HeLa , Humanos , Raios Infravermelhos/uso terapêutico , Resultado do Tratamento
19.
Neuropsychopharmacology ; 44(11): 1932-1939, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31153156

RESUMO

Diffusion tensor imaging (DTI) studies show widespread white matter abnormalities in schizophrenia, but it is difficult to directly relate these parameters to biological processes. Neurite orientation dispersion and density imaging (NODDI) is geared toward biophysical characterization of white matter microstructure, but only few studies have leveraged this technique to study white matter alterations. We recruited 42 schizophrenia patients (30 antipsychotic-naïve and 12 currently untreated) and 42 matched controls in this prospective study. We assessed the orientation dispersion index (ODI) and extracellular free water (FW) using single-shell DTI data before and after a 6-week trial of risperidone. Longitudinal data were available for 27 patients. Voxelwise analyses showed significantly increased ODI in the posterior limb of the internal capsule in unmedicated patients (242 voxels; x = -24; y = 6; z = 6; p < 0.01; α < 0.04), but no alterations in FW. Whole brain measures did not reveal alterations in ODI but a 6.3% trend-level increase in FW in unmedicated SZ (t = -1.873; p = 0.07). Baseline ODI was negatively correlated with subsequent response to antipsychotic treatment (r = -0.38; p = 0.049). Here, we demonstrated altered fiber complexity in medication-naïve and unmedicated patients with a schizophrenia spectrum illness. Lesser whole brain fiber uniformity was predictive of poor response to treatment, suggesting this measure may be a clinically relevant biomarker. Interestingly, we found no significant changes in NODDI indices after short-term treatment with risperidone. Our data show that biophysical diffusion models have promise for the in vivo evaluation of brain microstructure in this devastating neuropsychiatric syndrome.


Assuntos
Encéfalo/diagnóstico por imagem , Neuritos , Esquizofrenia/diagnóstico por imagem , Substância Branca/diagnóstico por imagem , Adolescente , Adulto , Imagem de Tensor de Difusão , Feminino , Humanos , Estudos Longitudinais , Masculino , Estudos Prospectivos , Adulto Jovem
20.
J Vet Intern Med ; 32(6): 1856-1863, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30328158

RESUMO

BACKGROUND: Radioiodine is the treatment of choice for hyperthyroidism in cats. The ideal method of dose determination of radioiodine remains controversial. OBJECTIVE: To compare a method of radioiodine dose determination that utilized thyroid scintigraphy with a standard fixed dose for treatment of hyperthyroidism. ANIMALS: Fifty-seven and 23 client-owned hyperthyroid cats in the variable and fixed dose groups, respectively. METHODS: Cats with a percent dose uptake using 99m Tc-pertechnetate uptake on thyroid scintigraphy <5%, 5%-10%, and >10% were to receive 3, 3.5, or 4.5 millicuries (mCi) of radioiodine, respectively, administered SC. Radioiodine dose was adjusted according to thyroid gland size as determined by the thyroid:salivary size ratio and categorized as <5:1, 5-10:1, and >10:1. If the thyroid size fell into a higher dosing category than the percent dose uptake, the dose was increased accordingly. Cats in the fixed dose group received 4.5 mCi. Six months after treatment, cats were determined to be euthyroid, hypothyroid, or hyperthyroid based on serum thyroxine and thyroid stimulating hormone concentrations. RESULTS: No difference in outcome was found between the variable and fixed dose treatment groups. Euthyroidism, hypothyroidism, and persistent hyperthyroidism developed in 61, 30, and 9% of cats in the fixed dose group compared to 58, 26, and 16%, respectively, in the variable dose group. CONCLUSIONS: A variable dosing method of radioiodine based on percent dose uptake primarily and thyroid gland size secondarily did not improve outcome compared to a standard fixed dose method.


Assuntos
Doenças do Gato/tratamento farmacológico , Hipertireoidismo/veterinária , Radioisótopos do Iodo/administração & dosagem , Animais , Gatos , Cálculos da Dosagem de Medicamento , Feminino , Hipertireoidismo/tratamento farmacológico , Radioisótopos do Iodo/uso terapêutico , Masculino , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA