Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
BMC Cardiovasc Disord ; 21(1): 323, 2021 06 30.
Artigo em Inglês | MEDLINE | ID: mdl-34193057

RESUMO

BACKGROUND: Self-expanding nitinol stent (SENS) implantation is commonly oversized in the superficial femoral artery (SFA), and leads to chronic outward force (COF) and in-stent restenosis (ISR). This study aimed to investigate the impact of COF of oversizing SENS on ISR of SFA. METHODS: In patients with implanted SENS in SFA, intimal hyperplasia especially between proximal segment and distal segment was evaluated by quantitative angiography, and the impact of COF on mid-term angiographic outcomes was investigated. In addition, porcine model with implanted SENS was used to evaluate the impact of COF on angiographic and histopathologic outcomes at 1 month. Excised stented arteries were evaluated by histopathologic analysis. RESULTS: We analyzed 65 SENS in 61 patients with follow-up angiography at 6 months to 1 year. The baseline diameter was 6.8 ± 0.71 mm and length were 97.0 ± 33.8 mm for the SENS. The ratio of the diameter of the stent to the reference vessel was 1.3 ± 0.24 at the proximal portion and 1.53 ± 0.27 at the distal portion (P < 0.001). In the long SFA stent, stent-to-vessel ratio was significantly higher in the distal stent than in the proximal stent (1.3 ± 0.2 vs. 1.55 ± 0.25, P = 0.001). ISR incidence was higher at the distal stent (37.3% vs 52.6%, P = 0.029). All 11 pigs survived for 4 weeks after SENS implantation. The vessel diameter was 4.04 ± 0.40 mm (control group) vs 4.45 ± 0.63 mm (oversized group), and the implanted stent diameter was 5.27 ± 0.46 mm vs. 7.18 ± 0.4 mm (P = 0.001). The stent-to-vessel diameter ratio was 1.31 ± 0.12 versus 1.63 ± 0.20 (P < 0.001). After 4 weeks, restenosis % was 29.5 ± 12.9% versus 46.8 ± 21.5% (P = 0.016). The neointimal area was 5.37 ± 1.15 mm2 vs. 8.53 ± 5.18 mm2 (P = 0.05). The restenosis % was 39.34 ± 8.53% versus 63.97 ± 17.1% (P = 0.001). CONCLUSIONS: COF is an important cause of restenosis in the distal portion of the SFA stent. Optimal sizing of the SFA stent is important to reduce the incidence of restenosis. Therefore, COF was an important factor of restenosis following distal SFA stenting.


Assuntos
Angioplastia/instrumentação , Artéria Femoral/fisiopatologia , Hemodinâmica , Doença Arterial Periférica/terapia , Stents Metálicos Autoexpansíveis , Ligas , Angioplastia/efeitos adversos , Animais , Constrição Patológica , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/patologia , Humanos , Modelos Animais , Neointima , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/patologia , Doença Arterial Periférica/fisiopatologia , Desenho de Prótese , Falha de Prótese , Recidiva , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Estresse Mecânico , Sus scrofa , Fatores de Tempo , Resultado do Tratamento
2.
Ann Vasc Surg ; 60: 388-396, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31200063

RESUMO

BACKGROUND: The clinical benefits and outcomes of the interventional treatment of small-sized infrapopliteal arteries using stent implantation remain uncertain. The aim of this study was to compare the safety and efficacy of drug-free bioresorbable vascular scaffold (BVS) with that of bare metal stent (BMS) in endovascular treatment of small-sized peripheral arteries. METHODS: In this study, drug-free BVS and BMS were used in eight porcine models. We compared the angiographic and histomorphometric findings in the two groups at 4 weeks. In each pig, BVS and BMS of adequate sizes were implanted in the small branch (<3 mm) of the femoral artery. Angiography, intravascular ultrasound (IVUS), and histomorphometric analysis were performed at 4 weeks. RESULTS: In the 4-week follow-up angiography and IVUS examination, the minimal luminal diameter was smaller and diameter stenosis was more severe in the BVS group. Histomorphometric findings indicated that the lumen area in the BVS group was smaller (0.34 ± 0.28 mm2 vs. 1.40 ± 0.52 mm2, P < 0.001), whereas the neointimal area (2.70 ± 1.28 mm2 vs. 1.76 ± 0.66 mm2, P = 0.013), area stenosis (85.18 ± 13.14 % vs. 54.99 ± 16.13 %, P < 0.001), inflammatory score (2.07 ± 0.861 vs. 28 ± 0.39, P = 0.003), and fibrin scores (1.24 ± 0.70 vs. 0.79 ± 0.72, P = 0.043) were significantly higher in the BVS group. The injury score was higher in the BMS group. In histopathologic findings, restenosis was mainly due to recoil and distortion of the scaffold in the BVS group. CONCLUSIONS: Compared with BMS, drug-free BVS was not feasible for small-sized peripheral arteries based on the angiographic, IVUS, and histomorphometric results primarily due to insufficient mechanical support.


Assuntos
Implantes Absorvíveis , Angioplastia com Balão/instrumentação , Stents Farmacológicos , Artéria Femoral , Metais , Stents , Angiografia , Angioplastia com Balão/efeitos adversos , Animais , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/patologia , Artéria Femoral/fisiopatologia , Masculino , Desenho de Prótese , Sus scrofa , Fatores de Tempo , Ultrassonografia de Intervenção , Grau de Desobstrução Vascular
3.
Korean Circ J ; 42(6): 397-405, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22787470

RESUMO

BACKGROUND AND OBJECTIVES: Although the use of heterogeneous overlapping drug-eluting stents (DES) is not uncommon in clinical practice, whether the implantation sequences of heterogeneous DES will influence the endothelialization or arterial responses differently remains unclear. MATERIALS AND METHODS: Twenty-one rabbits were randomized to receive overlapping stents in the iliac artery for 3 months {distal sirolimus-eluting stent (SES, Cypher™)+proximal paclitaxel-eluting stent (PES, Taxus™) (C+T, n=7), distal Taxus+proximal Cypher (T+C, n=7) and bare metal stent (BMS)+BMS (B+B, n=7)}. Endothelial function was evaluated by the acetylcholine provocation test during follow-up angiography. Histopathological changes in proximal, overlapped, and distal stented segments were evaluated. RESULTS: Although the overall angiographic outcomes were comparable, late loss (mm) in the distal stented segment was higher in the B+B (0.39±0.07) and C+T (0.40±0.20) than that in the T+C (0.06±0.02) group (p<0.001). The incidence of acetylcholine-induced spasm was higher in the DES groups compared with BMS, regardless of the implantation sequences (85.7% in C+T vs. 14.3% in B+B vs. 71.4% in T+C, p=0.017). Notably, only the distal Cypher implantation group (C+T) had three cases of stent fracture. A histopathological analysis showed that despite similar arterial injury scores, Taxus and Cypher stents had higher inflammatory reactions at the overlapped and distal segments compared with those of BMS. CONCLUSION: Despite similar arterial injury, higher inflammatory reactions were observed in overlapping DES segments regardless of the implantation sequence compared with that of BMS. Moreover, DES was associated with impaired endothelial function on the adjacent non-stented segments.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA