Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Malar J ; 14: 360, 2015 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-26390924

RESUMO

BACKGROUND: An accurate estimate of Plasmodium vivax prevalence is essential for the successful implementation of malaria control and elimination programmes. Prevalence estimates both inform control strategies and are used in their evaluation. Light microscopy is the main method for detecting Plasmodium parasitaemia in the peripheral blood, but compared to molecular diagnostics, such as polymerase chain reaction (PCR), has limited sensitivity. METHODS: A systematic review and meta-analysis was conducted to assess the effect of detection method on the prevalence of P. vivax and to quantify the extent to which P. vivax infections are undetected by microscopy. Embase, Medline and the Cochrane Database were searched for studies reporting prevalence by PCR and by microscopy and that contained all of the following key words: vivax, PCR, and malaria. Prevalence estimates and study meta-data were extracted systematically from each publication. Combined microscopy:PCR prevalence ratios were estimated by random effects meta-analysis. Sensitivity and specificity of microscopy were calculated using PCR as the gold standard. RESULTS: Of 874 studies reviewed, 40 met the criteria for inclusion contributing 54 prevalence pairs. The prevalence of P. vivax infection measured by PCR was consistently higher than the prevalence measured by microscopy with sub-patent parasitaemia. The mean prevalence of infection detected by microscopy was 67 % (95 % CI 59-73 %) lower than the prevalence detected by PCR. The detection of sub-patent parasitaemia did not vary according to the microscopy method (thick or, thick and thin smears), the PCR prevalence (as a measure of the true P. vivax prevalence), the type of blood used or DNA extraction method. CONCLUSIONS: Quantifying P. vivax parasitaemia by PCR rather than microscopy consistently increased prevalence estimates by a factor of 2.3. Whilst the sensitivity of microscopy can be improved by better methods, molecular methods have potential to be scaled up to improve the detection of P. vivax transmission reservoirs.


Assuntos
Malária Vivax/diagnóstico , Malária Vivax/epidemiologia , Microscopia , Técnicas de Diagnóstico Molecular , Humanos , Prevalência , Sensibilidade e Especificidade
2.
Chemosphere ; 83(3): 281-6, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21216431

RESUMO

Chemically chlorinated organic matter as well as natural background humic acids contain significant amounts of organically bound halogens that must be determined for assessment of environmental pollution. In this work the use of ion chromatography (IC) and inductively coupled plasma mass spectrometry (ICP-MS) is proposed for the determination of total organic Cl, Br and I concentration in humic acids extracted from various forest soil horizons after a single digestion by microwave-induced combustion (MIC). Samples were pressed as pellets and combusted using 20 bar of oxygen and ammonium nitrate solution as igniter. Analytes were absorbed in diluted alkaline solution (50mM (NH(4))(2)CO(3)) and a reflux step was applied after combustion to improve analyte recoveries (5 min, microwave power of 1400W). The accuracy was evaluated using certified reference materials (CRM) and spiked samples. Using MIC the agreement with CRM values and spike recoveries was higher than 97% for all analytes. As an advantage over conventional procedures, using MIC it was possible to digest up to eight samples in only 25 min, obtaining a single solution suitable for all halogens determination in humic acids samples by different techniques (IC and ICP-MS). The limit of detection (3σ) for Cl, Br and I obtained by IC was 1.2, 2.5 and 4.3µgg(-1) and by ICP-MS it was 1.4, 0.03 and 0.002µgg(-1), respectively.


Assuntos
Substâncias Húmicas/análise , Hidrocarbonetos Halogenados/análise , Incineração/métodos , Micro-Ondas , Poluentes do Solo/análise , Hidrocarbonetos Halogenados/química , Poluentes do Solo/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA