Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Front Neurol ; 8: 431, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28919877

RESUMO

BACKGROUND: Our group earlier developed a small monitoring device, which uses accelerometer measurements to accurately detect motor fluctuations in patients with Parkinson's (On and Off state) based on an algorithm that characterizes gait through the frequency content of strides. To further validate the algorithm, we studied the correlation of its outputs with the motor section of the Unified Parkinson's Disease Rating Scale part-III (UPDRS-III). METHOD: Seventy-five patients suffering from Parkinson's disease were asked to walk both in the Off and the On state while wearing the inertial sensor on the waist. Additionally, all patients were administered the motor section of the UPDRS in both motor phases. Tests were conducted at the patient's home. Convergence between the algorithm and the scale was evaluated by using the Spearman's correlation coefficient. RESULTS: Correlation with the UPDRS-III was moderate (rho -0.56; p < 0.001). Correlation between the algorithm outputs and the gait item in the UPDRS-III was good (rho -0.73; p < 0.001). The factorial analysis of the UPDRS-III has repeatedly shown that several of its items can be clustered under the so-called Factor 1: "axial function, balance, and gait." The correlation between the algorithm outputs and this factor of the UPDRS-III was -0.67 (p < 0.01). CONCLUSION: The correlation achieved by the algorithm with the UPDRS-III scale suggests that this algorithm might be a useful tool for monitoring patients with Parkinson's disease and motor fluctuations.

3.
Stud Health Technol Inform ; 207: 115-24, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25488217

RESUMO

This paper presents REMPARK system, a novel approach to deal with Parkinson's Disease (PD). REMPARK system comprises two closed loops of actuation onto PD. The first loop consists in a wearable system that, based on a belt-worn movement sensor, detects movement alterations that activate an auditory cueing system controlled by a smartphone in order to improve patient's gait. The belt-worn sensor analyzes patient's movement through real-time learning algorithms that were developed on the basis of a database previously collected from 93 PD patients. The second loop consists in disease management based on the data collected during long periods and that enables neurologists to tailor medication of their PD patients and follow the disease evolution. REMPARK system is going to be tested in 40 PD patients in Spain, Ireland, Italy and Israel. This paper describes the approach followed to obtain this system, its components, functionalities and trials in which the system will be validated.


Assuntos
Biorretroalimentação Psicológica/métodos , Doença de Parkinson/diagnóstico , Doença de Parkinson/terapia , Qualidade de Vida , Telemedicina/métodos , Terapia Assistida por Computador/métodos , Antiparkinsonianos/administração & dosagem , Biorretroalimentação Psicológica/instrumentação , Monitoramento de Medicamentos/instrumentação , Monitoramento de Medicamentos/métodos , Desenho de Equipamento , Humanos , Monitorização Ambulatorial/instrumentação , Monitorização Ambulatorial/métodos , Integração de Sistemas , Telemedicina/instrumentação , Terapia Assistida por Computador/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA