Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Ann Rheum Dis ; 81(2): 232-236, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34407928

RESUMO

OBJECTIVES: This study aimed to determine the prevalence of ultrasound-detected tendon abnormalities in healthy subjects (HS) across the age range. METHODS: Adult HS (age 18-80 years) were recruited in 23 international Outcome Measures in Rheumatology ultrasound centres and were clinically assessed to exclude inflammatory diseases or overt osteoarthritis before undergoing a bilateral ultrasound examination of digit flexors (DFs) 1-5 and extensor carpi ulnaris (ECU) tendons to detect the presence of tenosynovial hypertrophy (TSH), tenosynovial power Doppler (TPD) and tenosynovial effusion (TEF), usually considered ultrasound signs of inflammatory diseases. A comparison cohort of patients with rheumatoid arthritis (RA) was taken from the Birmingham Early Arthritis early arthritis inception cohort. RESULTS: 939 HS and 144 patients with RA were included. The majority of HS (85%) had grade 0 for TSH, TPD and TEF in all DF and ECU tendons examined. There was a statistically significant difference in the proportion of TSH and TPD involvement between HS and subjects with RA (HS vs RA p<0.001). In HS, there was no difference in the presence of ultrasound abnormalities between age groups. CONCLUSIONS: Ultrasound-detected TSH and TPD abnormalities are rare in HS and can be regarded as markers of active inflammatory disease, especially in newly presenting RA.


Assuntos
Tendões/diagnóstico por imagem , Tendões/patologia , Tenossinovite/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Voluntários Saudáveis , Humanos , Hipertrofia/diagnóstico por imagem , Hipertrofia/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Tenossinovite/diagnóstico por imagem , Ultrassonografia , Adulto Jovem
2.
Rheumatology (Oxford) ; 61(8): 3341-3350, 2022 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-34849616

RESUMO

OBJECTIVE: The aim of this exercise from the OMERACT Ultrasound subgroup on Sjögren's syndrome was to develop and assess the reliability of a consensus-based semiquantitative colour Doppler US scoring system for pathologic salivary gland vascularization in patients with primary Sjögren's syndrome (pSS). METHODS: Using the Delphi method, a colour Doppler semiquantitative scoring system for vascularization of bilateral parotid and submandibular glands was developed and tested in static images and on patients (9 pSS patients and 9 sonographers). Intra-reader and inter-reader reliability of grading the salivary glands were computed by weighted Cohen and Light's kappa analysis, respectively. RESULTS: The consensus-based semiquantitative score was: grade 0, no visible vascular signals; grade 1, focal, dispersed vascular signals; grade 2, diffuse vascular signals detected in <50% of the gland; grade 3, diffuse vascular signals in >50% of the gland. In static images, the intra- and inter-reader reliability showed excellent kappa values (95% CI) of 0.90 (0.87, 0.93) and 0.80 (0.74, 0.84), respectively, for all four salivary glands together. In patients, the intra- and inter-reader reliability for all four salivary glands together was kappa = 0.84 (0.73, 0.92) and 0.70 (0.64, 0.76), respectively. CONCLUSION: The consensus-based colour Doppler US scoring for the evaluation of salivary gland vascularization in pSS showed a good inter-reader reliability and excellent intra-reader reliability in static images and in patients. The clinical application of the developed scoring system should be tested in clinical settings.


Assuntos
Síndrome de Sjogren , Humanos , Inflamação/patologia , Reprodutibilidade dos Testes , Glândulas Salivares/diagnóstico por imagem , Glândulas Salivares/patologia , Síndrome de Sjogren/diagnóstico por imagem , Síndrome de Sjogren/patologia , Glândula Submandibular/diagnóstico por imagem , Ultrassonografia/métodos
3.
Ann Rheum Dis ; 78(7): 967-973, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31036626

RESUMO

OBJECTIVE: To develop ultrasound (US) definitions and a US novel scoring system for major salivary gland (SG) lesions in patients with primary Sjögren's syndrome (pSS) and to test their intrareader and inter-reader reliability using US video clips. METHODS: Twenty-five rheumatologists were subjected to a three-round, web-based Delphi process in order to agree on (1) definitions and scanning procedure of salivary gland ultrasonography (SGUS): parotid, submandibular and sublingual glands (PG, SMG and SLG); (2) definitions for the elementary SGUS lesions in patients with Sjögren's syndrome; (3) scoring system for grading changes. The experts rated the statements on a 1-5 Likert scale. In the second step, SGUS video clips of patients with pSS and non-pSS sicca cases were collected containing various spectrums of disease severity followed by an intrareader and inter-reader reliability exercise. Each video clip was evaluated according to the agreed definitions. RESULTS: Consensual definitions were developed after three Delphi rounds. Among the three selected SGs, US assessment of PGs and SMGs was agreed on. Agreement was reached to score only greyscale lesions and to focus on anechoic/hypoechoic foci in a semiquantitative matter or, if not possible on a qualitatively (present/absent) evaluation of fatty or fibrous lesions. Intrareader reliability for detecting and scoring these lesions was excellent (Cohen's kappa 0.81) and inter-reader reliability was good (Light's kappa 0.66). CONCLUSION: New definitions for developing a novel semiquantitative US score in patients with pSS were developed and tested on video clips. Inter-reader and intrareader reliabilities were good and excellent, respectively.


Assuntos
Interpretação de Imagem Assistida por Computador/normas , Glândulas Salivares/diagnóstico por imagem , Síndrome de Sjogren/diagnóstico por imagem , Ultrassonografia/normas , Consenso , Técnica Delphi , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia/métodos
4.
Ann Rheum Dis ; 77(8): 1194-1199, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29535120

RESUMO

OBJECTIVES: To assess the reliability of the OMERACT ultrasound (US) definitions for the identification of calcium pyrophosphate deposition disease (CPPD) at the metacarpal-phalangeal, triangular fibrocartilage of the wrist (TFC), acromioclavicular (AC) and hip joints. METHODS: A web-based exercise and subsequent patient-based exercise were carried out. A panel of 30 OMERACT members, participated at the web-based exercise by evaluating twice a set of US images for the presence/absence of CPPD. Afterwards, 19 members of the panel met in Siena, Italy, for the patient-based exercise. During the exercise, all sonographers examined twice eight patients for the presence/absence of CPPD at the same joints. Intraoberserver and interobserver kappa values were calculated for both exercises. RESULTS: The web-based exercise yielded high kappa values both in intraobserver and interobserver evaluation for all sites, while in the patient-based exercise, inter-reader agreement was acceptable for the TFC and the AC. TFC reached high interobserver and intraobserver k values in both exercises, ranging from 0.75 to 0.87 (good to excellent agreement). AC reached moderate kappa values, from 0.51 to 0.85 (moderate to excellent agreement) and can readily be used for US CPPD identification. CONCLUSIONS: Based on the results of our exercise, the OMERACT US definitions for the identification of CPPD demonstrated to be reliable when applied to the TFC and AC. Other sites reached good kappa values in the web-based exercise but failed to achieve good reproducibility at the patient-based exercise, meaning the scanning method must be further refined.


Assuntos
Condrocalcinose/diagnóstico por imagem , Ultrassonografia/normas , Articulação Acromioclavicular/diagnóstico por imagem , Idoso , Feminino , Articulação do Quadril/diagnóstico por imagem , Humanos , Cooperação Internacional , Internet , Masculino , Articulação Metacarpofalângica/diagnóstico por imagem , Pessoa de Meia-Idade , Variações Dependentes do Observador , Sistemas de Informação em Radiologia , Reprodutibilidade dos Testes , Ultrassonografia/métodos , Articulação do Punho/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA