Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Transl Med ; 22(1): 276, 2024 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-38486224

RESUMO

BACKGROUND: CLAD (Chronic Lung Allograft Dysfunction) remains a serious complication following lung transplantation. Some evidence shows that portions of Extracorporeal Photopheresis (ECP)-treated patients improve/stabilize their graft function. In spite of that, data concerning molecular mechanisms are still lacking. Aims of our study were to assess whether ECP effects are mediated by Mononuclear Cells (MNCs) modulation in term of microRNAs (miRNAs) expression and growth factors release. METHODS: Cells from leukapheresis of 16 CLAD patients, at time 0 and 6-months (10 cycles), were cultured for 48h ± PHA (10 ug/ml) or LPS (2 ug/ml). Expression levels of miR-146a-5p, miR-155-5p, miR-31-5p, miR181a-5p, miR-142-3p, miR-16-5p and miR-23b-5p in MNCs-exosomes were evaluated by qRT-PCR, while ELISA assessed different growth factors levels on culture supernatants. RESULTS: Our result showed miR-142-3p down-regulation (p = 0.02) in MNCs of ECP-patients after the 10 cycles and after LPS stimulation (p = 0.005). We also find miR-146a-5p up-regulation in cells after the 10 cycles stimulated with LPS (p = 0.03). Connective tissue growth factor (CTGF) levels significantly decreased in MNCs supernatant (p = 0.04). The effect of ECP is translated into frequency changes of Dendritic Cell (DC) subpopulations and a slight increase in T regulatory cells (Treg) number and a significant decrease in CTGF release. CONCLUSIONS: ECP might affect regulatory T cell functions, since both miR-142 and miR-146a have been shown to be involved in the regulation of suppressor regulatory T cell functions and DCs. On the other side ECP, possibly by regulating macrophage activation, is able to significantly down modulate CTGF release.


Assuntos
MicroRNAs , Fotoferese , Humanos , MicroRNAs/genética , Lipopolissacarídeos/farmacologia , Leucócitos , Regulação para Baixo/genética
2.
Transfus Apher Sci ; 62(3): 103724, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37202323

RESUMO

Extracorporeal photopheresis (ECP) is a cell therapy originally employed for cutaneous T cell lymphoma and later for GvHD, solid organ rejection and other immunological diseases demonstrating an excellent safety profile. Mononuclear cell (MNCs) apoptosis triggered by UV-A light irradiation in the presence of 8-methoxypsoralene has a key role in priming the cells, ultimately leading to immunomodulation. We report preliminary data about an evaluation of the new automated irradiator device LUMILIGHT (Pelham Crescent srl) for off-line ECP. Fifteen MNCs samples collected by apheresis from 15 adult patients undergoing ECP at our Center were cultured immediately after irradiation along with untreated samples and evaluated at 24, 48 and 72 h timepoints for T cell apoptosis and viability by flow cytometry with Annexin V and Propide Iodidum staining. Post irradiation Hematocrit (HCT), calculated by the device, was compared with that of the automated cell counter. Bacterial contamination was also tested. In irradiated samples after 24-48 and 72 h, the average total apoptosis was 47 %, 70 % and 82 %, respectively, showing a significant difference from untreated samples; residual viable lymphocytes at 72 h were, on average, 18 %. The greatest initiation of apoptosis occurred from 48 h of irradiation onwards. Average early apoptosis of irradiated samples decreased over time (26 %, 17 % and 10 % at 24, 48 and 72 h, respectively). HCT measured by LUMILIGHT was over-estimated, possibly due to the low pre irradiation red blood cell contamination. Bacterial tests resulted negative. Our study showed the LUMILIGHT device to be a valid instrument for MNCs irradiation with good handling and no major technical problems as well as no adverse events in the patients. Our data need to be confirmed in larger studies.


Assuntos
Remoção de Componentes Sanguíneos , Doença Enxerto-Hospedeiro , Fotoferese , Neoplasias Cutâneas , Adulto , Humanos , Fotoferese/métodos , Linfócitos , Leucócitos , Neoplasias Cutâneas/terapia , Doença Enxerto-Hospedeiro/terapia
3.
Transfus Apher Sci ; 61(4): 103398, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35227599

RESUMO

BACKGROUND: Test the ability of Mirasol Pathogen Reduction Technology (PRT, Terumo BCT, Lakewood Co, USA) treatment with riboflavin and ultraviolet light (R + UV) in reducing SARS-CoV-2 infectivity while maintaining blood product quality. MATERIAL AND METHODS: SARS-CoV-2 strains were isolated and titrated to prepare cell free virus for plasma units infection. The units were then under treatment with Mirasol PRT. The infectious titers were determined before and after treatment with an in house microtitration assay on Vero E6 cells. Thirty-six plasma pool bags underwent PRT treatment. RESULTS: In all the experiments, the measured titer following riboflavin and UV treatment was below the limit of detection of microtitration assay for all the different SARS-CoV-2 strains. Despite the high copies number detected by RT-PCR for each viral strain after treatment, viruses were completely inactivated and not able to infect VERO E6 cells. CONCLUSION: Riboflavin and UV light treatment effectively reduced the virus titers of human plasma to the limit of detection in tissue culture, regardless of the strain. These data suggest that pathogen reduction in blood products highlight the safety of CP therapy procedures for critically ill COVID-19 patients, while maintaining blood product quality.


Assuntos
Tratamento Farmacológico da COVID-19 , SARS-CoV-2 , Humanos , Riboflavina/farmacologia , Raios Ultravioleta
4.
Transfusion ; 61(3): 830-838, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33231325

RESUMO

BACKGROUND: Although many trials are currently investigating the safety and efficacy of convalescent plasma (CP) in critically ill COVID-19 patients, there is a paucity of ongoing and published studies evaluating the CP donors' side. This retrospective study reports the first Italian experience on CP donors' selection and donations. METHODS: Patients aged 18-68 years who had recovered from COVID-19 at least 2 weeks previously were recruited between March 18 and June 30, 2020 in a study protocol at the Italian hospitals of Pavia and Mantova. RESULTS: During the study period, 494 of 512 donors recruited were judged eligible and underwent 504 plasmapheresis procedures. Eighty-five percent (437/512) of the CP donors were males. The average time between symptom recovery and CP donation was 36.6 (±20.0) days. Four hundred and eighty-eight plasmapheresis procedures (96.8%) were concluded and each unit was divided into two subunits (total 976) with an average volume of 316.2 (±22.7) mL. Ninety-three percent (460/494) of CP donors at the time of plasma donation had a neutralizing IgG titer ≥1:80. Plasmapheresis-related adverse reactions occurred in 2.6% (13/504) of cases; all the reactions were mild and none required therapeutic intervention. Donors' age and COVID-19 severity were positively associated with greater antibody responses. CONCLUSION: This study demonstrates the feasibility and safety of a pilot CP program conducted in Italy. The identification of factors (ie, age and severity of COVID-19) positively associated with higher neutralizing antibody titers at the time of donation may help to optimize the selection of CP donors.


Assuntos
Doadores de Sangue/estatística & dados numéricos , COVID-19/terapia , Seleção do Doador/estatística & dados numéricos , Adolescente , Adulto , Idoso , COVID-19/imunologia , Seleção do Doador/métodos , Estudos de Viabilidade , Feminino , Humanos , Imunização Passiva , Itália , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Plasmaferese/efeitos adversos , Plasmaferese/estatística & dados numéricos , Estudos Retrospectivos , Adulto Jovem , Soroterapia para COVID-19
5.
Vox Sang ; 114(8): 884-889, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31463961

RESUMO

BACKGROUND AND OBJECTIVES: Very recently, Fresenius Kabi, improved the software (autoMNC lymphocytes, SW 04.03.08) for mononuclear cells (MNCs) collection with the aim to ameliorate the quality of harvest, employing the automated autoMNC lymphocytes software SW 04.03.09. Herein, we report the results of an observational study evaluating the feasibility of MNCs collection in patients undergoing extracorporeal photopheresis (ECP) at our centre, using the new COM.TEC software 04.03.08c for MNC collection, afterwards integrated in the software 04.03.09, available on the market since November 2018. MATERIALS AND METHODS: Thirty adult patients (21 males and 9 females) with GvHD, Chronic Lung Allograft Dysfunction or renal rejection, were consecutively enrolled to undergo 1 ECP procedure by the offline technique, according to our internal protocol, processing 1·5 blood volumes. Feasibility of collection was defined as: Hct in collection bag ≤5%, MNCs purity (percentage of MNCs/bag) ≥80%, MNCs collection efficiency (CE2) ≥60%, patient's platelet depletion ≤50%. RESULTS: Thirty ECP procedures were evaluated. Feasibility (defined by the four parameters previously described) of MNCs collection was observed in 1 out of the 30 harvests analysed. Median Hct in the product was 3·45% (IQR: 2·6-5·0), and median MNCs purity was 97·2% (IQR 89·1-98·6). Median CE2 for MNCs was 21·4% (IQR: 11·9-41·2), and median patient's platelet depletion was 36·2% (IQR 21·9-51·4). CONCLUSION: The autoMNC lymphocytes software SW 04.03.08c for MNCs collection in ECP setting demonstrated to collect a good quality product in terms of purity and RBC contamination even if the collection efficiency and platelet contamination must be improved.


Assuntos
Automação/métodos , Leucócitos Mononucleares/citologia , Fotoferese/métodos , Software , Adulto , Estudos de Viabilidade , Feminino , Humanos , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade
6.
Diagnostics (Basel) ; 13(13)2023 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-37443651

RESUMO

Despite the substantial transfusion requirements, there are few studies on the optimal transfusion strategy in pediatric patients undergoing hematopoietic stem cell transplantation (HSCT). Our study aimed to retrospectively analyze red blood cell (RBC) and platelet (PLT) transfusion practices during the first 100 days after HSCT at the pediatric hematology/oncology unit of our hospital between 2016 and 2019, due to a more restrictive approach adopted after 2016. We also evaluated the impact on patient outcomes. A total of 146 consecutive HSCT patients were analyzed. In patients without hemorrhagic complications, the Hb threshold for RBC transfusions decreased significantly from 2016 to 2017 (from 7.8 g/dL to 7.3 g/dL; p = 0.010), whereas it remained the same in 2017, 2018, and 2019 (7.3, 7.2, and 7.2 g/dL, respectively). Similarly, the PLT threshold decreased significantly from 2016 to 2017 (from 18,000 to 16,000/µL; p = 0.026) and further decreased in 2019 (15,000/µL). In patients without severe hemorrhagic complications, the number of RBC and PLT transfusions remained very low over time. No increase in 100-day and 180-day non-relapse mortality or adverse events was observed during the study period. No patient died due to hemorrhagic complications. Our preliminary observations support robust studies enrolling HSCT patients in patient blood management programs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA