Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 29(3): 1489-1495, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30159618

RESUMO

PURPOSE: Developmental dysplasia of the hip (DDH) diagnosis by two-dimensional ultrasound (2DUS) can have poor inter-rater reliability. 3D ultrasound (3DUS) may be more reliably performed, particularly by novice users. We compared intra- and inter-rater reliability between expert and novice operators performing 2DUS and 3DUS for DDH. MATERIALS AND METHODS: Infants with suspected DDH were assessed with 2DUS and 3DUS. Novice operators had 1.5 h of training and Experts had 5-15 years' experience. Images included two 2DUS static and two 3DUS sweep images per operator. Image quality was assessed by 5-point system (yes/no: full femoral head; full acetabular roof; horizontal iliac wing; os ischium; absent motion/artifact). 2DUS indices (alpha angle, coverage) were measured centrally by a blinded reader with 2 years DDH US experience. 3DUS was post-processed by semi-automated custom software generating acetabular surface models, indices and estimated probability of DDH. Gold-standard diagnosis of each hip as normal, borderline or dysplastic was based on radiologist review of expert 2DUS. RESULTS: Thirty infants, mean age 10.8 weeks were enrolled. Quality scores were 2.7±1.2 Novice versus 4.9±0.3 Expert for 2DUS (p = 0.04), and 4.2±1.0 Novice versus 4.9±0.3 Expert for 3DUS (p = 0.99). Inter-rater reliability was poor for 2DUS (ICC=0.10 for alpha angle, 0.04 for acetabular coverage) and moderate to high for 3DUS (ICC=0.73-0.83 for alpha angle, 0.55 for acetabular coverage). Intra-rater reliability and diagnostic accuracy was higher for 3DUS than 2DUS. CONCLUSION: Novice operators can perform 3DUS for DDH with reliability and accuracy approaching expert sonographers. Novices perform 2DUS with poor reliability and accuracy. KEY POINTS: • Novice/expert inter-rater reliability improved from poor with 2DUS to moderate/high with 3DUS. • Novice operators using 3DUS correctly classified 57/58 (98%) of infant hips. • DDH can be reliably assessed by novice operators using 3DUS.


Assuntos
Competência Clínica , Luxação Congênita de Quadril/diagnóstico por imagem , Ultrassonografia/métodos , Acetábulo/diagnóstico por imagem , Artefatos , Feminino , Cabeça do Fêmur/diagnóstico por imagem , Humanos , Ílio/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Lactente , Recém-Nascido , Ísquio/diagnóstico por imagem , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes
2.
Radiology ; 287(3): 1003-1015, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29688160

RESUMO

Purpose To validate accuracy of diagnosis of developmental dysplasia of the hip (DDH) from geometric properties of acetabular shape extracted from three-dimensional (3D) ultrasonography (US). Materials and Methods In this retrospective multi-institutional study, 3D US was added to conventional two-dimensional (2D) US of 1728 infants (mean age, 67 days; age range, 3-238 days) evaluated for DDH from January 2013 to December 2016. Clinical diagnosis after more than 6 months follow-up was normal (n = 1347), borderline (Graf IIa, later normalizing spontaneously; n = 140) or dysplastic (Graf IIb or higher, n = 241). Custom software accessible through the institution's research portal automatically calculated indexes including 3D posterior and anterior alpha angle and osculating circle radius from hip surface models generated with less than 1 minute of user input. Logistic regression predicted clinical diagnosis (normal = 0, dysplastic = 1) from 3D indexes (ie, age and sex). Output represented probability of hip dysplasia from 0 to 1 (output: >0.9, dysplastic; 0.11-0.89, borderline; <0.1, normal). Software can be accessed through the research portal. Results Area under the receiver operating characteristic curve was equivalently high for 3D US indexes and 2D US alpha angle (0.996 vs 0.987). Three-dimensional US helped to correctly categorize 97.5% (235 of 241) dysplastic and 99.4% (1339 of 1347) normal hips. No dysplastic hips were categorized as normal. Correct diagnosis was provided at initial 3D US scan in 69.3% (97 of 140) of the studies diagnosed as borderline at initial 2D US scans. Conclusion Automatically calculated 3D indexes of acetabular shape performed equivalently to high-quality 2D US scans at tertiary medical centers to help diagnose DDH. Three-dimensional US reduced the number of borderline studies requiring follow-up imaging by over two-thirds.


Assuntos
Luxação do Quadril/diagnóstico por imagem , Imageamento Tridimensional/métodos , Ultrassonografia/métodos , Feminino , Articulação do Quadril/diagnóstico por imagem , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos
3.
Front Aging Neurosci ; 14: 783773, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35211005

RESUMO

BACKGROUND: Parkinson's disease (PD) is not exclusively a motor disorder. Among non-motor features, patients with PD possess sensory visual dysfunctions. Depth perception and oculomotor deficits can significantly impact patients' motor performance. Stereopsis and eye behavioral study using 3D stimuli may help determine their implications in disease status. OBJECTIVE: The objective of this study is to investigate stereopsis and eye movement abnormalities in PD with reliable tools and their correlation with indicators of PD severity. We hypothesize that patients with PD exhibit different eye behaviors and that these differences may correlate to the severity of motor symptoms and cognitive status. METHODS: Control and PD participants were first evaluated for visual acuity, visual field, contrast acuity, and stereo perception with 2D and Titmus stereotests, followed by the assessment with a 3D active shutter system. Eye movement behaviors were assessed by a Tobii X2-60 eye tracker. RESULTS: Screening visual tests did not reveal any differences between the PD and control groups. With the 3D active shutter system, the PD group demonstrated significantly worse stereopsis. The preserved cognitive function was correlated to a more intact stereo function. Patients with PD had longer visual response times, with a higher number of fixations and bigger saccade amplitude, suggesting fixation stabilization difficulties. Such changes showed a positive correlation with the severity of motor symptoms and a negative correlation with normal cognitive status. CONCLUSION: We assessed stereopsis with a 3D active shutter system and oculomotor behaviors with the Tobii eye tracker. Patients with PD exhibit poorer stereopsis and impaired oculomotor behaviors during response time. These deficits were correlated with PD motor and cognitive status. The visual parameters may potentially serve as the clinical biomarkers for PD.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA