Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
World J Urol ; 41(12): 3737-3744, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37917223

RESUMO

PURPOSE: In the emerging field of robotics, only few studies investigated the transition between different robotic platforms in terms of surgical outcomes. We aimed at assessing surgical outcomes of patients receiving robot-assisted radical prostatectomy (RARP) and robot-assisted partial nephrectomy (RAPN) at a high-volume robotic center during the transition from Si to Xi Da Vinci surgical systems. METHODS: We analyzed data of 1884 patients undergoing RARP (n = 1437, 76%) and RAPN (n = 447, 24%) at OLV hospital (Aalst, Belgium) between 2011 and 2021. For both procedures, we assessed operative time, estimated blood loss, length of stay, and positive surgical margins. For RARP, we investigated length of catheterization and PSA persistence after surgery, whereas warm ischemia time, clampless surgery, and acute kidney injury (AKI) were assessed for RAPN. Multivariable analyses (MVA) investigated the association between robotic platform (Si vs. Xi) and surgical outcomes after adjustment for patient- and tumor-related factors. RESULTS: A total of 975 (68%) and 462 (32%) patients underwent RARP performed with the Si vs. Xi surgical system, respectively. Baseline characteristics did not differ between the groups. On MVA, we did not find evidence of a difference between the groups with respect to operative time (estimate: 1.07) or estimated blood loss (estimate: 32.39; both p > 0.05). Median (interquartile range [IQR]) length of stay was 6 (3, 6) and 4 (3, 5) days in the Si vs. Xi group, respectively (p < 0.0001). On MVA, men treated with the Xi vs. Si robot had lower odds of PSM (Odds ratio [OR]: 0.58; p = 0.014). A total of 184 (41%) and 263 (59%) patients received RAPN with the Si and Xi robotic system, respectively. Baseline characteristics, including demographics, functional data, and tumor-related features did not differ between the groups. On MVA, operative time was longer in the Xi vs. Si group (estimate: 30.54; p = 0.006). Patients treated with the Xi vs. Si system had higher probability of undergoing a clampless procedure (OR: 2.56; p = 0.001), whereas the risk of AKI did not differ between the groups (OR: 1.25; p = 0.4). On MVA, patients operated with the Xi robot had shorter length of stay as compared to the Si group (estimate: - 0.86; p = 0.003), whereas we did not find evidence of an association between robotic system and PSM (OR: 1.55; p = 0.3). CONCLUSION: We found that the Xi robot allowed for improvements in peri-operative outcomes as compared to the Si platform, with lower rate of positive margins for RARP and higher rate of off-clamp procedures for RAPN. Hospital stay was also shorter for patients operated with the Xi vs. Si robot, especially after robot-assisted partial nephrectomy. Awaiting future investigations-in particular, cost analyses-these results have important implications for patients, surgeons, and healthcare policymakers.


Assuntos
Injúria Renal Aguda , Neoplasias , Procedimentos Cirúrgicos Robóticos , Robótica , Masculino , Humanos , Resultado do Tratamento , Procedimentos Cirúrgicos Robóticos/métodos
2.
Int Braz J Urol ; 49(4): 521-522, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37267619

RESUMO

INTRODUCTION: Bladder neck dissection is one of the most delicate surgical steps of robotic-assisted radical prostatectomy (RARP) [1, 2], and it may affect surgical margins rate and functional outcomes [3, 4]. Given the relationship between outcomes and surgical experience [5-7], it is crucial to implement a step-by-step approach for each surgical step of the procedure, especially in the most challenging part of the intervention. In this video compilation, we described the techniques for bladder neck dissection utilized at OLV Hospital (Aalst, Belgium). SURGICAL TECHNIQUE: We illustrated five different techniques for bladder neck dissection during RARP. The anterior technique tackles the bladder neck from above until the urethral catheter is visualized, and then the dissection is completed posteriorly. The lateral and postero-lateral approaches involve the identification of a weakness point at the prostate-vesical junction and aim to develop the posterior plane - virtually until the seminal vesicles - prior to the opening of the urethra anteriorly. Finally, we described our techniques for bladder neck dissection in more challenging cases such as in patients with bulky middle lobes and prior surgery for benign prostatic hyperplasia. All approaches follow anatomic landmarks to minimize positive surgical margins and aim to preserve the bladder neck in order to promote optimal functional recovery. All procedures were performed with DaVinci robotic platforms using a 3-instruments configuration (scissors, fenestrated bipolar, and needle driver). As standard protocol at our Institution, urinary catheter was removed on postoperative day two [8]. CONCLUSIONS: Five different approaches for bladder neck dissection during RARP were described in this video compilation. We believe that the technical details provided here might be of help for clinicians who are starting their practice with this surgical intervention.


Assuntos
Neoplasias da Próstata , Procedimentos Cirúrgicos Robóticos , Robótica , Masculino , Humanos , Bexiga Urinária/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Robótica/métodos , Esvaziamento Cervical , Próstata , Glândulas Seminais , Prostatectomia/métodos , Neoplasias da Próstata/cirurgia
3.
Medicina (Kaunas) ; 59(1)2023 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-36676757

RESUMO

Background and Objectives: The aim of this article is to present a single-surgeon, open retroperitoneal lymph node dissection (RPLND) series for testicular cancer in a high-volume center. Materials and Methods: We reviewed data from patients who underwent RPLND performed by an experienced surgeon at our institution between 2000 and 2019. We evaluated surgical and perioperative outcomes, complications, Recurrence-Free Survival (RFS), Overall Survival (OS), and Cancer-Specific Survival (CSS). Results: RPLND was performed in primary and secondary settings in 21 (32%) and 44 (68%) patients, respectively. Median operative time was 180 min. Median hospital stay was 6 days. Complications occurred in 23 (35%) patients, with 9 (14%) events reported as Clavien grade ≥ 3. Patients in the primary RPLND group were significantly younger, more likely to have NSGCT, had higher clinical N0 and M0, and had higher nerve-sparing RPLND (all p ≤ 0.04) compared to those in the secondary RPLND group. In the median follow-up of 120 (56-180) months, 10 (15%) patients experienced recurrence. Finally, 20-year OS, CSS, and RFS were 89%, 92%, and 85%, respectively, with no significant difference in survival rates between primary vs. secondary RPLND subgroups (p = 0.64, p = 0.7, and p = 0.31, respectively). Conclusions: Open RPLND performed by an experienced high-volume surgeon achieves excellent oncological and functional outcomes supporting the centralization of these complex procedures.


Assuntos
Neoplasias Testiculares , Masculino , Humanos , Centros de Atenção Terciária , Espaço Retroperitoneal/cirurgia , Espaço Retroperitoneal/patologia , Estudos Retrospectivos , Excisão de Linfonodo/métodos , Estadiamento de Neoplasias , Resultado do Tratamento
4.
Int J Urol ; 29(3): 222-228, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34894001

RESUMO

OBJECTIVE: Local tumor ablation to treat small renal mass is increasing. The aim of the present study was to compare oncologic outcomes among patients with T1 renal mass treated with partial nephrectomy and local tumor ablation. METHODS: To reduce the inherent differences between patients undergoing laparoscopic or robot-assisted partial nephrectomy (n = 405) and local tumor ablation (n = 137), we used a 1:1 propensity score-matched analysis. Local tumor ablation consisted of radiofrequency ablation and cryoablation. Disease-free survival, overall survival and other causes mortality-free survival rates were estimated using the Kaplan-Meier method. Multivariable logistic regression and competing-risk regression models were used to identify predictors of complications, recurrence and other causes mortality, respectively. RESULTS: Partial nephrectomy had higher disease-free survival estimates, as compared with local tumor ablation (92.8% vs 80.4% at 5 years, P = 0.02), with no significant difference between radiofrequency ablation and cryoablation (P = 0.9). Ablation showed comparable overall survival estimates to partial nephrectomy (91% vs 95.8% at 5 years, P = 0.6). The 5-year recurrence rates were 7.9% versus 23.8% for patients aged ≤70 years, and 2.5% versus 11.9% for patients aged >70 years treated with partial nephrectomy and ablation, respectively; the 5-year other causes mortality rates were 0% and 2.2% for patients treated with partial nephrectomy and ablation aged ≤70 years, and 3% versus 10.9% for patients aged >70 years treated with partial nephrectomy and ablation, respectively. At multivariable analysis, ablation was associated with fewer complications (odds ratio 0.41; P = 0.01). At competing risks analysis, age (hazard ratio 0.96) and ablation (hazard ratio 4.56) were independent predictors of disease recurrence (all P ≤ 0.008). CONCLUSIONS: Local tumor ablation showed a higher risk of recurrence and lower risk of complications compared with partial nephrectomy, with comparable overall survival rates.


Assuntos
Carcinoma de Células Renais , Ablação por Cateter , Neoplasias Renais , Idoso , Carcinoma de Células Renais/patologia , Ablação por Cateter/efeitos adversos , Humanos , Neoplasias Renais/patologia , Recidiva Local de Neoplasia/epidemiologia , Recidiva Local de Neoplasia/cirurgia , Nefrectomia/efeitos adversos , Nefrectomia/métodos , Pontuação de Propensão , Estudos Retrospectivos , Resultado do Tratamento
7.
J Clin Med ; 13(19)2024 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-39407796

RESUMO

Immune checkpoint inhibitors (ICI) have become the cornerstone of treatment in renal cell carcinoma (RCC), for both metastatic disease and in an adjuvant setting. However, an adaptive resistance from cancer cells may arise during ICI treatment, therefore many studies are focusing on additional immune checkpoint inhibitor pathways. Promising targets of immunotherapeutic agents under investigation include T cell immunoglobulin and ITIM domain (TIGIT), immunoglobulin-like transcript 4 (ILT4), lymphocyte activation gene-3 (LAG-3), vaccines, T cell immunoglobulin and mucin domain-containing protein 3 (TIM-3), and chimeric antigen receptor (CAR) T cells. In this review of the literature, we recollect the current knowledge of the novel treatment strategies in the field of immunotherapy that are being investigated in RCC and analyze their mechanism of action, their activity and the clinical studies that are currently underway.

8.
Front Oncol ; 14: 1324631, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38807770

RESUMO

Introduction: Prostate-specific membrane antigen (PSMA) is a transmembrane protein expressed by normal prostatic tissue. Therefore, molecular imaging targeting PSMA (PSMA-PET) has gained particular interest and diffusion for PCa staging and restaging. Several factors may affect PSMA-PET results, and many tools have been proposed to improve patient selection. Furthermore, PSMA expression is not homogeneous among different tissues and within the prostate itself. The aims of this study were to evaluate immunohistochemistry (IHC) features of prostate biopsy samples and to assess their correlation with whole-mount specimens and PSMA-PET parameters. Methods: We included consecutive high-risk PCa patients who underwent PSMA-PET for staging proposal at our institution from January 2022 to December 2022. The PET parameters selected were SUVmax, total volume (TV), and total lesion activity (TL). Each patient underwent multiparametric MRI (mpMRI) and fusion-targeted prostate biopsy prior to surgery. IHC analyses were performed on the index lesion cores. IHC visual score (VS) (1, 2, 3) and visual pattern (VP) (membranous, cytoplasmic, and combined) and the percentage of PSMA-negative tumor areas (PSMA%neg) within biopsy cores were evaluated. Results: Forty-three patients who underwent robotic radical prostatectomy after PSMA-PET were available for analyses. Concordance between VS and VP at biopsy and final pathology showed a Cohen's kappa coefficient of 0.39 and 0.38, respectively. Patients with PSMA%neg <20% had a higher concordance in VS and VP (Cohen's kappa 0.49 and 0.4, respectively). No difference emerged in terms of median PSMA-TV (p = 0.3) and PSMA-TL (p = 0.9) according to VS at biopsy, while median SUVmax was higher in patients with VS 3 (p = 0.04). Higher SUVmax was associated with membranous and combined VP expression (p = 0.008). No difference emerged between patients with PSMA%neg <20% or PSMA%neg >20% on biopsy cores in terms of SUVmax, PSMA-TL, and PSMA-TV (p = 0.5, p = 0.5, and p = 0.9 respectively). Conclusions: We found a correlation between IHC VS and VP on targeted biopsy cores and SUVmax at PSMA-PET. However, the correlation between the IHC parameters of biopsy cores and final pathology was not as high as expected. Nevertheless, the presence of PSMA%neg <20% seems to have a better concordance in terms of visual score.

9.
J Robot Surg ; 18(1): 153, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38563887

RESUMO

Robot-assisted partial nephrectomy (RAPN) is a complex and index procedure that urologists need to learn how to perform safely. No validated performance metrics specifically developed for a RAPN training model (TM) exist. A Core Metrics Group specifically adapted human RAPN metrics to be used in a newly developed RAPN TM, explicitly defining phases, steps, errors, and critical errors. A modified Delphi meeting concurred on the face and content validation of the new metrics. One hundred percent consensus was achieved by the Delphi panel on 8 Phases, 32 Steps, 136 Errors and 64 Critical Errors. Two trained assessors evaluated recorded video performances of novice and expert RAPN surgeons executing an emulated RAPN in the newly developed TM. There were no differences in procedure Steps completed by the two groups. Experienced RAPN surgeons made 34% fewer Total Errors than the Novice group. Performance score for both groups was divided at the median score using Total Error scores, into HiError and LoError subgroups. The LowErrs Expert RAPN surgeons group made 118% fewer Total Errors than the Novice HiErrs group. Furthermore, the LowErrs Expert RAPN surgeons made 77% fewer Total Errors than the HiErrs Expert RAPN surgeons. These results established construct and discriminative validity of the metrics. The authors described a novel RAPN TM and its associated performance metrics with evidence supporting their face, content, construct, and discriminative validation. This report and evidence support the implementation of a simulation-based proficiency-based progression (PBP) training program for RAPN.


Assuntos
Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Aprendizagem , Benchmarking , Transfusão de Sangue , Nefrectomia
10.
Eur Urol Focus ; 10(1): 107-114, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37634969

RESUMO

BACKGROUND: In the field of robotic surgery, there is a lack of comparative evidence on surgical and functional outcomes of different robotic platforms. OBJECTIVE: To assess the outcomes of patients receiving robot-assisted radical prostatectomy (RARP) at a high-volume robotic center with daVinci and HUGO robot-assisted surgery (RAS) surgical systems. DESIGN, SETTING, AND PARTICIPANTS: We analyzed the data of 542 patients undergoing RARP ± extended pelvic lymph node dissection at OLV hospital (Aalst, Belgium) between 2021 and 2023. All procedures were performed by six surgeons using daVinci or HUGO RAS robots; the use of one platform rather than the other did not follow any specific preference and/or indication. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Multivariable analyses investigated the association between robotic system (daVinci vs HUGO RAS) and surgical outcomes after adjustment for patient- and tumor-related factors. Urinary continence recovery was defined as the use of no/one safety pad. RESULTS AND LIMITATIONS: A total of 378 (70%) and 164 (30%) patients underwent RARP with daVinci and HUGO RAS surgical systems, respectively. Despite a higher rate of palpable disease in the HUGO RAS group (34% vs 25%), baseline characteristics did not differ between the groups (all p > 0.05). After adjusting for confounders, we did not find evidence of a difference between the groups with respect to operative time (estimate: 16.71; 95% confidence interval [CI]: -6.35, 39.78; p = 0.12), estimated blood loss (estimate: 3.12; 95% CI: -67.03, 73.27; p = 0.9), and postoperative Clavien-Dindo ≥2 complications (odds ratio [OR]: 1.66; 95% CI: 0.34, 8.15; p = 0.5). On final pathology, 55 (15%) and 20 (12%) men in, respectively, the daVinci and the HUGO RAS group had positive surgical margins (PSMs; p = 0.5). On multivariable analyses, we did not find evidence of an association between a robotic system and PSMs (OR: 1.08; 95% CI: 0.56, 2.07; p = 0.8). Similarly, the odds of recovering continence did not differ between daVinci and HUGO RAS cases after both 1 mo (OR: 0.78; 95% CI: 0.45, 1.38; p = 0.4) and 3 mo (OR: 1.17; 95% CI: 0.49, 2.79; p = 0.7). CONCLUSIONS: Among patients receiving RARP with daVinci or HUGO RAS surgical platforms, we did not find differences in surgical and functional outcomes between the robots. This may be a result of a standardized surgical technique that allowed surgeons to transfer their skills between robotic systems. Awaiting future investigations with longer follow-up, these results have important implications for patients, surgeons, and health care policymakers. PATIENT SUMMARY: We compared surgical and functional outcomes of patients receiving robot-assisted radical prostatectomy with daVinci versus HUGO robot-assisted surgery (RAS) robots. The two platforms were able to achieve similar outcomes, suggesting that the introduction of HUGO RAS is safe and allows for optimal outcomes after radical prostatectomy.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Masculino , Humanos , Feminino , Procedimentos Cirúrgicos Robóticos/métodos , Próstata , Prostatectomia/métodos , Excisão de Linfonodo
12.
J Robot Surg ; 17(4): 1401-1409, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36689078

RESUMO

RAPN training usually takes place in-vivo and methods vary across countries/institutions. No common system exists to objectively assess trainee capacity to perform RAPN at predetermined performance levels prior to in-vivo practice. The identification of objective performance metrics for RAPN training is a crucial starting point to improve training and surgical outcomes. The authors sought to examine the reliability, construct and discriminative validity of objective intraoperative performance metrics which best characterize the optimal and suboptimal performance of a reference approach for training novice RAPN surgeons. Seven Novice and 9 Experienced RAPN surgeons video recorded one or two independently performed RAPN procedures in the human. The videos were anonymized and two experienced urology surgeons were trained to reliably score RAPN performance, using previously developed metrics. The assessors were blinded to the performing surgeon, hospital and surgeon group. They independently scored surgeon RAPN performance. Novice and Experienced group performance scores were compared for procedure steps completed and errors made. Each group was divided at the median for Total Errors score, and subgroup scores (i.e., Novice HiErrs and LoErrs, Experienced HiErrs and LoErrs) were compared. The mean inter-rater reliability (IRR) for scoring was 0.95 (range 0.84-1). Compared with Novices, Experienced RAPN surgeons made 69% fewer procedural Total Errors. This difference was accentuated when the LoErr Expert RAPN surgeon's performance was compared with the HiErrs Novice RAPN surgeon's performance with an observed 170% fewer Total Errors. GEARS showed poor reliability (Mean IRR = 0.44; range 0.0-0.8), for scoring RAPN surgical performance. The RAPN procedure metrics reliably distinguish Novice and Experienced surgeon performances. They further differentiated performance levels within a group with similar experiences. Reliable and valid metrics will underpin quality-assured novice RAPN surgical training.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Cirurgiões , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Reprodutibilidade dos Testes , Competência Clínica , Nefrectomia/educação
13.
Eur Urol Focus ; 9(2): 388-395, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36229343

RESUMO

BACKGROUND: Robot-assisted partial nephrectomy (RAPN) training usually takes place in vivo, and methods vary across countries/institutions. No common system exists to objectively assess trainee ability to perform RAPN at predetermined performance levels prior to in vivo practice. The identification of objective performance metrics for RAPN training is a crucial starting point to improve training and surgical outcomes. OBJECTIVE: We sought to identify objective performance metrics that best characterize a reference approach to RAPN, and obtain face and content validity from procedure experts through a modified Delphi meeting. DESIGN, SETTING, AND PARTICIPANTS: During a series of online meetings, a core metrics team of three RAPN experts and a senior behavioral scientist performed a detailed task deconstruction of a transperitoneal left-sided RAPN procedure. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Based on published guidelines, manufacturers' instructions, and unedited videos of RAPN, the team identified performance metrics that constitute an optimal approach for training purposes. The metrics were then subjected to an in-person modified international Delphi panel meeting with 19 expert surgeons. RESULTS AND LIMITATIONS: Eleven procedure phases, with 64 procedure steps, 43 errors, and 39 critical errors, were identified. After the modified Delphi process, the international expert panel added 13 metrics (two steps), six were deleted, and three were modified; 100% panel consensus on the resulting metrics was obtained. Limitations are that the metrics are applicable only to left-sided RAPN cases and some might have been excluded. CONCLUSIONS: Performance metrics that accurately characterize RAPN procedure were developed by a core group of experts. The metrics were then presented to and endorsed by an international panel of very experienced peers. Reliable and valid metrics underpin effective, quality-assured, structured surgical training for RAPN. PATIENT SUMMARY: We organize a meeting among robot-assisted partial nephrectomy (RAPN) experts to identify and reach consensus on objective performance metrics for RAPN training. The metrics are a crucial starting point to improve and quality assure surgical training and patients' clinical outcomes.


Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Consenso , Procedimentos Cirúrgicos Robóticos/métodos , Nefrectomia/métodos
14.
Eur Urol Focus ; 9(4): 642-644, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36690548

RESUMO

Clinical data on robot-assisted radical prostatectomy (RARP) performed with the new Hugo robot-assisted surgery (RAS) system are scarce. We described surgical outcomes of 112 consecutive patients who underwent RARP ± extended pelvic lymph-node dissection (ePLND) at OLV Hospital (Aalst, Belgium) between February and November 2022. The median age was 65 yr (interquartile range [IQR] 60-70) and median preoperative prostate-specific antigen (PSA) was 7.9 ng/ml (5.8-10.7). Thirty-eight patients (34%) had International Society of Urological Pathology grade group ≥3 tumor on prostate biopsy. On preoperative magnetic resonance imaging, 26 (23%) patients had a suspicion of extraprostatic disease. The median operative time was 180 min (IQR 145-200) and 27 men (24%) underwent ePLND. On final pathology, 34 patients (31%) had extraprostatic disease and ten (9%) had positive surgical margins. The median number of nodes removed was 15 (IQR 9-19). Among men with data available on the first PSA after surgery, 88% (60/68) had undetectable PSA (<0.1 ng/ml). The probability of urinary continence (UC) recovery was 36% (95% confidence interval [CI] 28-47%) at 1 mo and 81% (95% CI 72-89%) at 3 mo. The median time to UC recovery was 36 d (95% CI 34-44). This is the first report of data on UC recovery and surgical pathology for patients undergoing RARP for prostate cancer performed with the Hugo RAS robotic system. Future investigations with longer follow-up are awaited. PATIENT SUMMARY: We describe surgical outcomes of patients undergoing robot-assisted surgical removal of the prostate for cancer performed with the Hugo RAS robotic system at our institution. In our experience this platform provided adequate results in terms of surgical results and early recovery of urinary continence. Studies with longer follow-up are awaited.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Masculino , Humanos , Idoso , Próstata/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Antígeno Prostático Específico , Prostatectomia/métodos
15.
Eur Urol ; 83(5): 413-421, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36737298

RESUMO

BACKGROUND: Selective clamping during robot-assisted partial nephrectomy (RAPN) requires extensive knowledge on patient-specific renal vasculature, obtained through imaging. OBJECTIVE: To validate an in-house developed perfusion zone algorithm that provides patient-specific three-dimensional (3D) renal perfusion information. DESIGN, SETTING, AND PARTICIPANTS: Between October 2020 and June 2022, 25 patients undergoing RAPN at Ghent University Hospital were included. Three-dimensional models, based on preoperative computed tomography (CT) scans, showed the clamped artery's ischemic zone, as calculated by the algorithm. SURGICAL PROCEDURE: All patients underwent selective clamping during RAPN. Indocyanine green (ICG) was administered to visualize the true ischemic zone perioperatively. Surgery was recorded for a postoperative analysis. MEASUREMENTS: The true ischemic zone of the clamped artery was compared with the ischemic zone predicted by the algorithm through two metrics: (1) total ischemic zone overlap and (2) tumor ischemic zone overlap. Six urologists assessed metric 1; metric 2 was assessed objectively by the authors. RESULTS AND LIMITATIONS: In 92% of the cases, the algorithm was sufficiently accurate to plan a selective clamping strategy. Metric 1 showed an average score of 4.28 out of 5. Metric 2 showed an average score of 4.14 out of 5. A first limitation is that ICG can be evaluated only at the kidney surface. A second limitation is that mainly patients with impaired renal function are expected to benefit from this technology, but contrast-enhanced CT is required at present. CONCLUSIONS: The proposed new tool demonstrated high accuracy when planning selective clamping for RAPN. A follow-up prospective study is needed to determine the tool's clinical added value. PATIENT SUMMARY: In partial nephrectomy, the surgeon has no information on which specific arterial branches perfuse the kidney tumor. We developed a surgeon support system that visualizes the perfusion zones of all arteries on a three-dimensional model and indicates the correct arteries to clamp. In this study, we validate this tool.


Assuntos
Neoplasias Renais , Procedimentos Cirúrgicos Robóticos , Humanos , Constrição , Nefrectomia/métodos , Rim/diagnóstico por imagem , Rim/cirurgia , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia , Neoplasias Renais/irrigação sanguínea , Procedimentos Cirúrgicos Robóticos/métodos , Perfusão , Verde de Indocianina , Algoritmos , Resultado do Tratamento , Estudos Retrospectivos
16.
Minerva Urol Nephrol ; 75(2): 223-230, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36847584

RESUMO

BACKGROUND: Patients with multiple ipsilateral renal masses have an augmented risk of metachronous contralateral lesions and are likely to undergo repeated surgeries. We report our experience with the technologies currently available and the surgical techniques to preserve healthy parenchyma while guaranteeing oncological radicality during robot-assisted partial nephrectomy (RAPN). METHODS: The data were collected at three tertiary-care centers, where 61 patients with multiple ipsilateral renal masses were treated with RAPN between 2012 and 2021. RAPN was performed with da Vinci Si or Xi surgical system using TilePro (Life360; San Francisco, CA, USA), indocyanine green fluorescence and intraoperative ultrasound. Three-dimensional reconstructions were built in some cases preoperatively. Different techniques were employed for hilum management. The primary endpoint is to report intra- and postoperative complications. Secondary endpoints were the estimated blood loss (EBL), warm ischemia time (WIT) and positive surgical margins (PSM) rate. RESULTS: Median preoperative size of the largest mass was 37.5 mm (24-51) with a median PADUA and R.E.N.A.L. score of 8 (7-9) and 7 (6-9). One hundred forty-two tumors were excised, with a mean number of 2.32. The median WIT was 17 (12-24) minutes, and the median EBL was 200 (100-400) mL. Intraoperative ultrasound was employed in 40 (67.8%) patients. The rate of early unclamping, selective clamping and zero-ischemia were respectively 13 (21.3%), 6 (9.8%) and 13 (21.3%). ICG fluorescence was employed in 21 (34.42%) patients and three-dimensional reconstructions were built in 7 (11.47%) patients. Three (4.8%) intraoperative complications occurred, all classified as grade-1 according to EAUiaiC. Postoperative complications were reported in 14 (22.9%) cases with 2 Clavien-Dindo grade >2 complications. Four (6.56%) patients had PSM. Mean period of follow-up was 21 months. CONCLUSIONS: In experienced hands, with the employment of the currently available technologies and surgical techniques, RAPN can guarantee optimal outcomes in patients with multiple ipsilateral renal masses.


Assuntos
Neoplasias Renais , Robótica , Humanos , Robótica/métodos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia , Neoplasias Renais/patologia , Resultado do Tratamento , Nefrectomia/métodos , Complicações Pós-Operatórias/etiologia
17.
J Endourol ; 37(1): 105-111, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36006369

RESUMO

Background: In robot-assisted partial nephrectomy (RAPN) renorrhaphy is used to achieve hemostatic control of the tumoral resection bed, with detrimental impact on renal function. Hemostatic agents are used to achieve rapid and optimal hemostasis. GATT-Patch is a new hemostatic sealant that has already demonstrated promising results. Objective: Compare GATT-Patch and standard renorrhaphy in terms of hemostatic capacity, ischemia time, and prevention of urinary leakage after RAPN in a porcine model. Design, Setting, and Participants: In this preclinical randomized controlled trial, four pigs underwent 32 RAPNs. After resection, GATT-Patch application and performance of classic renorrhaphy were randomized. After the procedure, the resection bed was reinspected. A necropsy study evaluated the adhesiveness of the patch, and retrograde pyelography was performed to determine the leakage burst pressure. Intervention: Application of GATT-Patch and performance of classic renorrhaphy were randomized and surgeons blinded to the hemostatic technique to be performed. Outcome Measurements and Statistical Analysis: Warm ischemia, hemostatic control, active bleeding during hemostatic control, total procedure time, bleeding at reinspection, and presence of urinary leakage on retrograde pyelography were recorded. Continuous variables were compared using the Student t-test. Categorical variables were compared using the Chi-square or Fisher's exact test. Results and Limitations: GATT-Patch reduced warm ischemia time (WIT), time to achieve hemostatic control, active bleeding time, and total procedure time, achieving hemostasis in 100% of the cases. Rebleeding at reinspection occurred in 0% of the GATT-Patch group. Renal parenchyma damage was observed in 100% of renorrhaphy cases and in 0% of GATT-Patch cases. Conclusions: GATT-Patch guaranteed optimal hemostasis and urine sealant effect after RAPN in porcine models. Compared to renorrhaphy, we observed a reduction in WIT, total procedure time, and potential reduction in healthy parenchyma loss. Patient Summary: GATT-Patch stops bleeding and provides hemostasis faster than suturing after resection of portions of the kidney in pigs. It might be tested in patients undergoing partial nephrectomy for kidney cancer.


Assuntos
Hemostáticos , Neoplasias Renais , Animais , Suínos , Hemostáticos/farmacologia , Hemostáticos/uso terapêutico , Rim/cirurgia , Nefrectomia/métodos , Neoplasias Renais/cirurgia , Hemostasia , Resultado do Tratamento
18.
J Endourol ; 37(1): 35-41, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36053673

RESUMO

Introduction and Hypothesis: Robotic sacropexy (RSC) emerged in the last years as a valid alternative to the laparoscopic technique. However, the robotic approach is still limited by platform availability and concerns about cost-effectiveness. Recently, new robotic platforms joined the market, lowering the costs and offering the possibility to expand the robotic approach. The aim of our study was to demonstrate the technical feasibility and safety of the procedure with this new platform along with the description of our surgical setting. Materials and Methods: We reported data on the first five consecutive patients who underwent RSC at Onze Lieve Vrouw Hospital (Aalst, Belgium), performed with the novel HUGO™ Robot-Assisted Surgery (RAS) System. The platform consists of four fully independent carts, an open console, and a system tower equipped for both laparoscopic and robotic surgery. We collected patients' characteristics, intraoperative data, intraoperative complications, and clashes of instruments. Results: All procedures were completed according to the same surgical setting and technique. No need for conversion to open/laparoscopic surgery and/or for additional port placement was required. No intraoperative complications, instrument clashes, or system failure that compromised the surgery's completion were recorded. Median interquartile range docking, operative, and console time were 8 (6-9), 130 (115-165), and 80 (80-115) minutes, respectively. Conclusion: This series represents the first worldwide report of a robot-assisted sacropexy executed with the novel HUGO RAS System. Awaiting future investigation, this preliminary experience provides relevant data in terms of operative room settings and perioperative outcomes that might be helpful for future adopters of this platform.


Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Laparoscopia/métodos , Complicações Intraoperatórias , Centros de Atenção Terciária , Encaminhamento e Consulta
19.
Minerva Urol Nephrol ; 75(2): 235-239, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36094389

RESUMO

Robot-assisted simple prostatectomy (RASP) has demonstrated better peri-operative outcomes as compared to open simple prostatectomy. However, RASP is still limited by platform availability and cost-effectiveness issues. The new surgical robots increasing competition may spread the robotic approach also in non-oncological fields. We reported the first RASP executed in Europe at OLV Hospital (Aalst, Belgium) performed with the novel HUGO™ Robot-Assisted Surgery (RAS) System. The platform consists of four independent carts, an open console, and a system tower equipped for both laparoscopic and robotic surgery. Our main goal was to demonstrate the technical feasibility of RASP with the novel HUGO™ RAS along with its safety in terms of perioperative outcomes and complications. We also aimed to describe our surgical setup. We collected patient's baseline characteristics, intraoperative and perioperative complications, postoperative outcomes, docking time, operative time, clashing of the instruments, or technical errors of the system. The procedure was performed in a 72-year-old male with a prostate volume of 155 g at preoperative imaging. No need for conversion to open/laparoscopic surgery and/or for additional port placement was required. No intraoperative complications, instrument clashes, or failure of the system that compromised the completion of the surgery were recorded. Docking, operative, and console times were 9, 150, and 120 minutes, respectively. The catheter was removed on the second postoperative day. No postoperative complications occurred. The postoperative uroflowmetry revealed a maximum flow of 26.2 mL/s, without postvoid residual volume. Robot-assisted simple prostatectomy with the HUGO™ RAS System is a feasible and safe procedure in terms of perioperative outcomes and complications. Our setup allowed for a rapid docking procedure and a smoothly completion of the surgery.


Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Robótica , Masculino , Humanos , Idoso , Procedimentos Cirúrgicos Robóticos/métodos , Robótica/métodos , Estudos de Viabilidade , Prostatectomia/métodos , Laparoscopia/efeitos adversos
20.
Asian J Urol ; 10(4): 475-481, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38024438

RESUMO

Objective: In the last years, robotic surgery was introduced in several different settings with good perioperative results. However, its role in the management of adrenal masses is still debated. In order to provide a contribution to this field, we described our step-by-step technique for robotic adrenalectomy (RA) and related modifications according to the type of adrenal mass treated. Methods: We retrospectively analyzed 27 consecutive patients who underwent RA at Onze-Lieve-Vrouw hospital (Aalst, Belgium) between January 2009 and October 2022. Demographic, intra- and post-operative, and pathological data were retrieved from our prospectively maintained institutional database. Continuous variables are summarized as median and interquartile range (IQR). Categorical variables are reported as frequencies (percentages). Results: Twenty-seven patients underwent RA were included in the study. Median age, body mass index, and Charlson's comorbidity index were 61 (IQR: 49-71) years, 26 (IQR: 24-29) kg/m2, and 2 (IQR: 0-3), respectively, and 16 (59.3%) patients were male. Median tumor size at computed tomography scan was 6.0 (IQR: 3.5-8.0) cm. Median operative time and blood loss were 105 (IQR: 82-120) min and 175 (IQR: 94-250) mL, respectively. No intraoperative complications were recorded. Overall postoperative complications rate was 11.1%, with a postoperative transfusion rate of 3.7%. A total of 10 (37.0%) patients harbored malignant adrenal masses. Among them, 3 (11.1%) had adrenocortical carcinoma, 6 (22.2%) secondary metastasis, and 1 (3.7%) malignant pheochromocytoma on final pathological exam. Only 1 (10.0%) patient had positive surgical margins. Conclusion: We described our step-by-step technique for RA, which can be safely performed even in case of high challenging settings as malignant tumors, pheochromocytoma, and large masses. The standardization of perioperative protocol should be encouraged to maximize the outcomes of this complex surgical procedure.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA